Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-Finance | ₹1.0 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹1.1 Cr+₹4.9 L (4.72%)Rejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹1.1 Cr+₹4.9 L (4.72%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.2 Cr+₹17.4 L (16.7%)Rejected-Finance | ₹1.2 Cr+₹17.4 L (16.7%) | L3 | Rejected-Finance L3 |
| 4 | L4₹1.3 Cr+₹25.9 L (24.9%)Rejected-Finance 78 JESSORE ROAD PURBACHAL MORE BARASAT NORTH 24 PGS | BARASAT | NORTH 24 PARGANAS | WEST BENGAL | 700124 | ₹1.3 Cr+₹25.9 L (24.9%) | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technical Reason |
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
2 Jun 2020, 5:00 pmClosed
SE SEC
OFFICE OF THE SUPERINTENDING ENGINEER SOUTHERN ELECTRICAL CIRCLE PWD KOL59
Construction of four storied Academic building at the premises of Road and Building Research Institute, Pailan - SITC of Sub Station, LT Panel, Fittings and Fixtures, LC installation and Compound Lighting.
2020_WBPWD_282305_1
WBPWD/SE/SEC/NIT-29/2019-2020 2nd call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
PAILAN
Please refer Tender documents.
8 documents required · 8 mandatory
₹2.5 L
OFFICE OF THE SE SEC
31 Jul 2020
28 Apr 2020
4 Jun 2020
29 Apr 2020
2 Jun 2020
1 May 2020
30 Apr 2020
Amount
PART A - SUB STATION WORK SUB-HEAD 1--SITC OF 11 KV VCB PANEL & 11/0.415 KV TRANSFORMERS & MAIN PANEL Supply & Delivery of Cast Resin Dry Type 11KV/415V 500 KVA, 3 Phase,50Hz, Dyn11,copper wound, Class F insulation associated with winding temperature indicator/controller,having cable end box in the HV & LV sides and all accessories and conforming to IS 11171-1985 & IS - 2026 with latest modification (if any) & CBIP Specification and as per detail specification attached ( uploaded in the specification section) [ Make: ABB/Voltamp ( Vadodara)/CGL ].
Installation & commissioning of 11KV/415V 500 KVA distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc.
Supply & Delivery Indoor-type, floor mounted,metal clad, single tier, fully compartmentalized,free standing, 11 kV VCB Panel with 3 Nos VCBs (1 Incomer + 2 Outgoing), totally enclosed and fully interlocked , horizontal drawout, horizontal / vertical isolation type breaker as per IS 13188, as ammended upto date and as per detail specification attached ( uploaded in the specification section) , suitable for use on 11 KV, 3 Phase,50 Hz AC supply to energise 2 X 500 KVA Dry Type Transformers. [ Make : ABB / Siemens / CGL].
Installation & commissioning of the above 11 kV VCB Panel with P.T & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement.
Making testing arrangement and submitting the test report for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments by authorized firm of Directorate of Electricity & commissioning the installation after obtaining the Approval of Directorate of Electricity.The scope shall be also included the necessary approval from Authority also.
Supply & fixing 75x45 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
SITC of floor mounted Indoor type extensible cubical MV switchboard,fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel,front and back openable, hinged, single shuttered, with incoming ACBs & Outgoing MCBS and all accessories as per size, design & drawing to be approved by EIC and conforming to IS with latest modification and as per detail specification attached ( uploaded in the specification section) [LT MAIN PANEL IN THE SUBSTATION]
SUB HEAD II - HT/ LT CABLING IN SUBSTATION Supplying of 11KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable conforming to IS 7098, of earthed system of following size.[ From Supplier HT Gear to Consumer HT Gear and to Transformer]. [ Make : Nicco / Gloster/Polycab/Havells/RR Kable/Crystal ] 3 Core x 300 Sq.mm
Making heatshrinkable joints indoor type to the ends of the following XLPE HT cable at the transformer end as well as at the VCB ends supplying with necy. jointing kits, sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EIC
Laying of 1 No. 11KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable confirming to IS 7098, of earthed system of following size in the existing Masonary Open Duct as required.
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size.[ Make Nicco / Gloster/ Finolex/Crystal/Polycab/RR Kable]
Laying of 1.1KV Grade XLPE Aluminium conductor, PVC sheathed, armoured cable of following size in the existing Masonary Open Duct as required. a) 4Core x 400 sq.mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below including finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
Supply & Drawing 1.1 KV Grade 7 Core 1.5 sq.mm PVC Armoured Copper Cable from Transformer WT relay to VCB WT relay for Power & Control Supply as per direction of EIC
Supply & Drawing 1.1 KV Grade 2 Core 2.5 sq.mm PVC Armoured Copper Cable as per direction of EIC
SUB HEAD III - EARTHING S& laying 240 sq. mm. single core multistrand PVC insulated flexible Cu wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer point as required (for Transformer /Generator neutral earthing) including Socketing both sides by Cu Socket.
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 65 mm x 8 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Insulating the 65 x 8 mm M.S. flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC (for transformer neutral earth bus bar).
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
SUB HEAD - IV ( SAFETY EQUIPMENT ) Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required. a) High Voltage - size 250mm x 200mm
b) Medium Voltage - size 200mm x 150mm
Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222-2002 and cylinders fully charged of following capacity(4.5 Kg ) [Make - Fire Shield/ Ceasefire]
Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield/ Ceasefire]
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.)
Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre).
Providing of rubber mat 2 mtrs Length x 1 m. wide and 12mm thick to withstand 15 KV dielectric strength as per IS 15652-2006.
Providing of rubber mat 2 mtrs Length x 1 m. wide and 6mm thick to with stand 3.3 KV dielectric strength as per IS 15652-2006.
SUB-HEAD VI--DISTRIBUTION WIRING for SUB STATION Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/Siemens/ABB ) 4Way
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+10 Way[ Legrand /Siemens/ABB ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/Siemens/ABB ] 32 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand /Siemens/ABB ] 6-32 SP
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size.[ Make Nicco / Gloster/ Finolex/Crystal/Polycab/RR Kable] 4Core 25 Sq. mm [ MAIN LT PANEL TO SUBSTATION TPNDB]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish including removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below including finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials b) 4Core 25 Sq. mm
Distn. wiring in 3X22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ RR Kabel] in 19 mm bore, 3 mm thick polythen pipe with all accessories embedded in wall (through rigid PVC pipe on ceiling) to light / fan / call bell points as per GS with following average run [ As per approved list of Material ] Ave run 10 Mtr
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ RR Kabel] in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point as per GS.[ As per approved list of Material ] On Board
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.[ As per approved list of Material ] 19 mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ RR Kabel] of the following sizes in the prelaid polythene pipe as per GS.[ As per approved list of Material ] 2x(2.5 sqmm)+1x(1.5 sqmm)[ for 16 A Power plug ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc including supplying sockets, tapes. [ 9 / F 5 ] 2x(2.5 sqmm)+1x(1.5 sqmm)
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 150 x 100 x 65
Supply & Fixing 240 V, 16A, plug socket with separate 16 A Piano key type switch on sheet metal switch board embedded in wall as per GS
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Supply of 240 V 1200 mm (48") sweep A.C. ceiling fan without regulator having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete in all respect. [Make: Crompton HS+ or HB+ / Orient Energy star / USHA Striker ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification as per GS.
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC Heavy Duty) 12"( 300mm ) Speed 920 RPM
Fixing only exhaust fan after making holes in wall as per GS (12")
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS (12")
Supply & Fixing Timer for controlling of exhaust fan fixed on wall in MS Box with top cover (L&T Micon225/equivalent Legrand).
S&D of 240V LED luminaire complete with all accessories as follows:- a) Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 1xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 1x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
b) Twin industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 2xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 2x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
c) Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp incl. S&F EI conduit “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting by S&F 2x24/0.20 mm flexible copper wire of 1.10 mtr. length and mending good damages to original finish and painting etc.
SUPPLY & LAYING OF CABLES Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/ Finolex/Crystal/Polycab/RR Kable] a)4 Core 400 Sq. mm
b) 4 Core 240 Sq. mm
c)4 Core 120 Sq. mm
d) 4 Core 95 Sq. mm
Laying of one Cables in existing covered masonery trench incl. taking out RC covers, setting them in order as and mending good the damages to GS.
Laying of one cable on wall/surface including S & F MS clams, making hole etc. as necy., mending good damages and painting
Laying of one Cables through prelaid UPVC / G.I. protection pipe as to GS.
Laying of one no. cable in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of two cables in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
Laying of three cables in an underground trench in single tier formation (horizontal) the trench size : 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricks per mtr. as separator between the cables including filling the space between the bricks and cables and also the trench with shifted soil, levelling up and restoring surface duly rammed
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. a)4 Core 400 Sq. mm
b) 4 Core 240 Sq. mm
c)4 Core 120 Sq. mm
d) 4 Core 95 Sq. mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required a)100mm dia
b) 150mm dia
[FEEDER PILLER BOX] SITC of Double door outdoor type Distribution Feeder Pillar box conforming to Indian Standard IS : 5039-1969 with latest amendments,suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. as per detailed specification ( uploaded in the specification section).
PART B - LT Panel, Fittings & Fixtures SITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker and as per detail specification attached ( uploaded in the specification section). The complete panel is to be installed on suitable brick padestal including net cement finish as per direction of the EIC. [LT MAIN PANEL AT BUILDING]
SITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker and as per detail specification attached ( uploaded in the specification section). The complete panel is to be installed on suitable brick padestal including net cement finish as per direction of the EIC. [DG PANEL ]
FAN, FITTINGS & FIXTURES Supply of 240 V 1200 mm (48") sweep A.C. ceiling fan without regulator having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete in all respect. [Make: Crompton HS+ or HB+ / Orient Energy star / USHA Striker ]
Supply of 240V, 16" (400 mm) Sweep, A.C. wall mounting bracket/cabin Fan with all accessories complete in all respect. [Make: Crompton -WM Wind Flow / Orient -wall-47-high speed]
Fixing of Ceiling Fan/Wall fan as per pwd schedule and as per direction of the EIC.
Supply of Exhaust fans complete with all accessories including Al. louver shutter having the following Model / Cat No. ( Make -EPC Heavy Duty) 12"( 300mm ) Speed 920 RPM
Fixing only exhaust fan & louver shutter after making holes in wall as per GS 12" (300MM)
Supply of 240 V 20" (500mm) sweep Pedestal Fan complete with all accessories such as P2 type capacitor, Regulator, Cord with 3-pin Top (Make - Orient - Farrrata FT-01/ Crompton - PF Windstar Farrata 20/ Equivalent EPC Make)
Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 1xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 1x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
Twin industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 2xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 2x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
Supply of recess mounted 2' x 2' LED luminaries . Philips : Smart Glow-Model RC 383B LED 36S-6500 PSU OD WH PIR/ Equivalent product of Crompton/ Wipro/ Jaquar having similar specification in all respect
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp incl. S&F EI conduit “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting by S&F 2x24/0.20 mm flexible copper wire of 1.10 mtr. length and mending good damages to original finish and painting etc.
Fixing of 2'x2' LED recess luminaries after making houshing in ceiling by Co's own tool & Tackles.
S&F of 10W LED Bulkhead Philips Model Endural LED/ Equivalent product of Crompton/ Wipro / Jaquar having similar specification in all respect
S&F of LED integral flood light Philips Model BVP122 LED 115 CW HE S4/ Equivalent product of Crompton/ Wipro / Jaquar having similar specification in all respect
PART C - LC INSTALLATION & COMPOUND LIGHTING a) SITC OF Lightning conductor S & Fixing of Lighting Conducter Air terminals made of 15 mm dia 1500 mm long GI pipe ( ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick G I base plate at bottom incl necessary holes etc duly grouted on parapet etc in CC morter (4:2:1)
Cutting cornices/steps etc including cutting recess in buildings etc & supply & fixing 15 mm bore ( ISI Medium) GI pipe protection as below and mending good damages to the building works. i)Length upto 0.5 Mtr
ii)Length above 0.5 Mtr
Making soldered joints between conducters, conducters & air terminals for 4 SWG GI ( Hot Dip) wire incl supply of jointing materials and painting with 2 (two) coats bituminous paint.
Making soldered joints between conducters and down pipes / other metalic objects for 4 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats bituminous paint.
Hiring charges for scaffolding arrangement including dismantling at the end of work & carriage, for L C installation per storey of building per vertical run.
S & Fixing of GI ( Hot Dip) strips 20mm x 3mm thick for horizontal run on the parapet / roof / wall with GI saddles 1100 mm apart incl mending good the damages to building work
S & Fixing of GI (Hot Dip) strips 20 mm x 3mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl good damages to building work
S & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip with 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded wire & 4 SWG GI (Hot Dip) wire of vertical conductor & Conductor from earth electrode complete with S & F thimbles, GI bolts, nuts,check-nuts, spring washers etc as required.
Earthing installation with 50mm dia (ISI-Medium) G.I. pipe x 3.04 Mtrs. Long incl. bolt, double nuts & washers for Soft Soil incl. excavation of soil as to GS.
b)Compound Lighting arrangement : Supply & Delivery of Hot Dip Galvanised (as per IS:2629 / IS 2633 / IS 4759 and with its latest amendment ) Octagonal Pole made of HT steel ( sheet thickness -3mm ) conforming to grade S355 of BSEN 10025 alongwith welded base plate of required size conforming to IS: 226 / 2062 with integrated Control box with required sizes studs for termination of 2 core 10 /4 Core 16 sq mm Al (Armoured ) cable incld S&F 1 No 6 Amp SP MCB ( C-Series ) for each out going circuit to the fittings with proper pad locking arrangement for the following pole -- 7 Mtr Long [ Top Dia ( A / F ) - 70 mm, Bottom Dia ( A / F ) -135 mm ] Base Plate Size : 225 mm x 225mm x 16 mm. ( Make : Bajaj, Philips, Valmont, CG, Transrail, Bansal ).
Errection of the following Octagonal pole by designing and Casting RCC ( M 20 ) foundation of suitable size as specified below considering the safe soil bearing capacity at site as T/sq m, including excavation of earth, providing, cutting, bending and placing in position reinforcement as per drawing and providing pipe for cable entry and exit as required and providing and fixing of 4 Nos foundation bolts ( J Type ) as specified below and as per drawing on ground surface including back filling and cleaning extra earth -7 Mtr Long [ Founation size - 500 mm X 500 mm X 1200 mm, J Bolt Size - M 20 X 600 ]
SITC of single dip galvanized steel overhang bracket ( Swan Neck Type/As per direction of the EIC ) at the top of the pole having 1.5 M length complete with all fixing arrangements as required including painting Single Arm
SITC of road lighting luminaire ( IP 65 ) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system suitable for use with 230Volt 50Hz AC supply etc as required. ( Make - Philips Model No. BRP340 LED 138 CW HO SLC S1 PSU GR/equivalent product of Crompton/Wipro having similar specification in all respect )
Supply & fixing of Timer control panel on wall comprising of :- i) 230V, 40A DP AC Mini power contactor - 1 nos ( NO + NC ), ii)Digital Timer 24 hours capacity, 230V, AC supply. iii ) 230V, 25A DP MCB, 10KA bracking "C" type. iv) 230V AC toggle switch.-1No. v) 230V, 40A, 3 way terminal. vi) 40A, 8way nutral bar, to be mount on DIN rail with necy. interconnection with 1.5 sqmm cu flexible wire ( Finolex / Havells/Polycab/RR Kable) including ferrule marking & socketing within the 12 way SPNDB MCB enclosure box. (Make - Legrand )
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size.[ Make Nicco / Gloster/Polycab/Havells/RR Kable/Crystal] i)2 Core6 Sq. mm
Laying of one No. cable above in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Laying of one No. cable above on wall/surface incl. S & F MS saddles, making holes etc. as necy. mending good damages and painting
Laying of one No. cable above through existing RCC/Hume/ GI Pipe/open masonary trench
Laying of one No. cable above after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth of 75 mm and mending good the damages to original finish incl. removing the rubbish
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 Core6 Sq. mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc.and making connection to switch, BDB and BBC etc. 2 Core6 Sq. mm
S & L of 1.1 KV grade 3 X 1.5 Sq mm FR single core multi stranded copper wire for connection from loop box to fittings through 13 mm dia polythene pipe.
Finishing of the PVC insulated wire(3 X 1.5sqmm) ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
S & F of medium gauge G.I pipe (ISI medium) having the following diameter [40 mm Diameter] for protection of cable with necessary fitting and jointing materials as required.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below (ISI medium G.I pipe)
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size 4 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
RASH ELECTRICAL WORKS
JADOB ELECTRIC CO.
S. G. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .