Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.3 LAccepted-AOC VILL KUTHIRAMPUR P O RAMPUR P S BHAGWANGOLA DIST MURSHIDABAD | KUTHIRAMPUR | MURSHIDABAD | WEST BENGAL | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹66.4 L+₹12.0 L (22.1%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹67.8 L+₹13.4 L (24.7%)Rejected-Finance 18 10 A C ROAD P O KHAGRA DIST MURSHIDABAD WEST BENGAL 742103 | KHAGRA | MURSHIDABAD | WEST BENGAL | 742103 | L3 | Rejected-Finance 3rd Lowest | |
| 4 | L4₹72.4 L+₹18.1 L (33.3%)Rejected-Finance | L4 | Rejected-Finance 4th Lowest | |
| 5 | Rejected-Technical VILL BHAKURI P O CHALTIA P S BERHAMPORE DIST MURSHIDABAD WEST BENGAL | BERHAMPORE | MURSHIDABAD | WEST BENGAL | - | Rejected-Technical Insufficient credential |
Tender Value
₹64.5 L
EMD Value
₹1.3 L
Closing Date
13 Sept 2021, 3:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer , DPMU, WB-ADMIP, Murshidabad
Office of the Executive Engineer, DPMU, WB-ADMIP, Agri-Engineering Building (1stfloor), Station road, Berhampore, Murshidabad, W.B. - 742101.
All in one Bid for construction of 01(One) no. Water Detention Structure (WDS) Scheme with allied structure named Palanda WDS at mouza Palanda under Sagardighi Block in the District of Murshidabad under WBADMI Project (Phase-VIII) for the F.Y.2021-20
2021_WRDD_340284_1
01/P-VIII/WBADMIP/MSD/R of 2021-22
Open Tender
CIVIL WORKS
Item Rate
120 days
Palanda, Sagardighi, WB
Please refer Tender documents.
3 documents required · 3 mandatory
₹1.3 L
Yes
7 Mar 2022
13 Aug 2021
15 Sept 2021
13 Aug 2021
13 Sept 2021
13 Aug 2021
180 days
Amount
EARTH WORK AND GRASS TURFING WITH SODS
Excavation in ordinary soil / mixed soil i.e. clay mixed with moorun, kankar, pebbles / silt dry or moist / slushy silt / sticky soil for WDS /WHS/RESERVOIR /SFMIS etc with hydraulic excavator of required bucket capacity including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirement of lines, grades and cross section and transporting to embankment! disposal site within all lifts and lead upto 1000 m including spreading, levelling disposed spoils at disposed area. (mode of measurement: pre work and post work) all complete.
Turfing with Sods Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the Engineer including preparation of ground, fetching of sods and watering as per Clause 307 of Specifications for Road & Bridge Works of MoRT & H (5th Revision).
Construction of Water Inlet & Outlet Structure ( 3 Nos.)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.
Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth.
Supply of 600 mm dia R.C.C. Hume pipe NP 3 spigot.
Laying and joining of R.C. spun pipes with matching collars of different sizes mentioned below in field trenches including and carrying the pipes and matching R.C.C. collars from stack, lowering the same within the trench, property positioning and levelling on bricks laid flat, filling the annular space between collar and the pipe joint with Jute braiding dipped in cement slurry, grouting with cement and sand mortar (1:2) mixed with approved quality water proofing compound (5% weight of cement, including cost of cement, bricks for levelling, braiding etc.) and curing all complete as per direction of the Engineer-in-Charge.
Construction of Drain (2 Nos.)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m (I.) SAIL/ TATA/RINL
Ordinary cement concrete ( mix 1:2:4 ) with graded stone chips ( 20mm nominal size ) exclusive shuttering and reinforcement if any in ground floor as per relevant I.S codes. a ) Pakur variety.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints , including throating, nosing and drip course, scaffolding/staging where necessary (ground floor),(i) With 1:6 cement mortar,(b) 20 mm. thick plaster
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.
Construction of Stair (2 Nos.)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (SAIL/ TATA/RINL).
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes,(a) Pakur Vareity.
Ordinary cement concrete ( mix 1:2:4 ) with graded stone chips ( 20mm nominal size ) exclusive shuttering and reinforcement if any in ground floor as per relevant I.S codes. a ) Pakur variety. (i) 75 mm thick.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).(ii) With 1:4 cement mortar,(a) 20 mm thick plaster.
Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc. NOTE:-Cement 0.152 cu.m per100 sq.m.
Miscellaneous
Construction of Display board as per drwaing and placeing of same at suitable location of the command area with best quality black granite with block letter incise as directed by the Engineer in charge.
Construction of vertical water gauge with M.S angle 65 x 65 x 6 mm of 3.00 mtr. Long as shown in the drawing with necessary bottom foundation for affixing of the gauge on ground .Water gauge to be painted and marked as directed by the E.I.C and to be fixed at a place inside the tank,all complete.
IKON CONSTRUCTION
PRADIP KUMAR DAS
TAIMUR SK
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .