GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-47(P)/2019-20 PROVN OF CERTAIN SANCTIONED WORKS IN SECTOR B UNDER AGE B/R-I OF GE (NORTH) AMBALA CANTT
2019_MES_307379_1
GE(N)Amb-47(P)/2019-20
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹60,000
Yes
8 Aug 2020
11 Jun 2020
13 Jul 2020
11 Jun 2020
11 Jul 2020
27 Jun 2020
12 Jun 2020 - 26 Jun 2020
60 days
Amount
B/R Schedule
Roughening surfaces of old concrete floor by picking sweeping clean and washing down with water to remove all dust and brushing neat cement slurry with 3 kg of cement per sqm complete all as specified and as directed by the Engr-in-charge.
M & L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tiles exc 0.18 but not exc 0.38 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 15mm cement screed bed in CM (1:4) complete all as specified and as directed by the Engr-in-charge.
M&L for ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) cut from tiles exc 0.18 but not exc 0.38 Sqm in vertical surfaces such as skirting,dados and riser to steps etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 10mm thick rendering in CM (1:4) complete all as specified and as directed by the Engr-in-charge.
M&L for glazed ceramic coloured tiles in vertical surfaces such as skirting,dados and riser to steps etc size 350mmx250mmx7mm/ 450mmx350mmx7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 10mm cement screed bed in CM (1:4) complete all as specified and as directed by the Engr-in-charge.
M&L for Double charged vitrified tiles joint free 10 mm thick (square/ rectangular) area of each tiles exc 0.36 Sqm but not exc 1 sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 15mm cement screed bed in CM (1:4) complete all as specified and as directed by the Engr-in-charge.
M&L for Double charged vitrified tiles joint free 10 mm thick (square/ rectangular) cut from area of each tiles exc 0.36 Sqm but not exc 1 sqm in skirting etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 10mm cement rendering in CM (1:4) complete all as specified and as directed by the Engr-in-charge.
M&L for machine cut kota stone slab flooring 18-20 mm thick set jointed and pointed in neat cement slurry with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 15 mm thick screed bed in CM (1:4) complete all as specified and as directed by the Engr-in-charge.
M&L Kota stone slab 18 to 20 mm thick in, riser to steps ,skirting dado and pillers laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing , notching edge,over 10 mm thick rendering in CM (1:4) complete all as specified and as directed by the Engr-in-charge..
M&L for green marble slab 18 to 20 mm thick bedded jointed and pointed in grey cement slurry and cutting polishing , rounded edge etc ,including over 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engr-in-charge.
Demolition of cement concrete in ground floor and pavings not exc. 15cm thickness (below or above GL) complete all as specified and as directed by the Engr-in-charge.
M&L for 25 mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in Sub base of floor complete all as specified and as directed by the Engr-in-charge.
M&L for 50 mm thick PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in plinth protection finished surfaces even and smooth with out using extra cement complete all as specified and as directed by the Engr-in-charge.
Demolition of reinforced cement concrete in (other then ground floor) roofs , beams staircase , landing , chajja and similar suspended works reinforcement cut as required to facilitate demolation complete all as specified and as directed by the Engr-in-charge.
M&L for pre cast reinforced cement concrete type B-1(1:2:4) using 20 mm graded stone aggregate as in landing cover slabs for man holes , landings, balconies canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engr-in-charge.
M&L for pre cast reinforced cement concrete type B-1(1:2:4) using 20 mm graded stone aggregate as in chajjas and the like complete all as specified and as directed by the Engr-in-charge.
Formwok to chullah hoods, chajjas trought and the similar items complete all as specified and as directed by the Engr-in-charge.
M&L for mild steel TMT bar 10 mm dia and over cut to lenth bent to shape required including cranking bending spirally for hopping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0,.9mm dia or screwing with clip etc complete all as specified and as directed by the Engr-in-charge.
-ditto- all as per item No 1.18 here in above but 6 to 8mm dia complete all as specified and as directed by the Engr-in-charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting n. exc 10 cm girth complete all as specified and as directed by the Engr-in-charge.
Demolition of brick work built in cement mortar or cement lime mortar and arches pillar etc but excluding ashlar fasing dressed stone work and pre cast concrete articles complete all as specified and as directed by the Engr-in-charge.
M & L for brickwork with Sub class'B' bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed by the Engr-in-charge.
All as per item No 1.23 as above but except bricks complete all as specified and as directed by the Engr-in-charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half bricks thick walls built in CM 1:4 complete all as spicified and as directed by the Engr-in-charge.
Taking down cement plaster including raking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed by the Engr-in-charge.
M&L 10 mm thick cement plaster in CM 1:3 on concrete surfaces finished even and smooth with out using extra cement on ceiling complete all as specified and as directed by the Engr-in-charge.
M&L 15 mm thick cement plaster on fair faces of bricks or concrete walls in CM 1:6 finished even and smooth with out using extra cement on brick work or concrete surfaces complete all as specified and as directed by the Engr-in-charge.
M&L 15 mm thick cement plaster on other then fair faces of brick works in CM 1:4 finished even and smooth with out using extra cement on brick work or concrete surfaces complete all as specified and as directed by the Engr-in-charge.
M& L washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 ement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified complete all as specified and as directed by the Engr-in-charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engr-in-charge.
M&L for preparation of old surfaces on ceiling and applying one coats of white wash complete all as specified and as directed by the Engr-in-charge.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by the Engr-in-charge.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed by the Engr-in-charge..
M&L for preparing old plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed by the Engr-in-charge.
M&L for preparing newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by the Engr-in-charge.
Complete removal of existing treatment and preparation of old plaster surfaces of wall and applying two coat of distemper oil emulsion complete all as specified and as directed by the Engr-in-charge..
Preparation of old/new plastered /unplastered/Washed stone grit plaster on surfaces on walls , chajjas, balcony, facias etc. and applying two coats of exterior emulsion paint over a coat alkali resistant primer, complete all as specified and as directed by the Engr-in-charge. Make: Apex of Asian or its equivalent in Berger/ Jenson Nicholson
M&L for 2 to 3 mm thick wall care putty on new or old plastered surfaces of wall complete all as specified and as directed by the Engr-in-charge.
S & F in repair Stainless steel decorative curtain rod 25mm dia fixed with decorative brackets ,stop roller and finials at the end etc complete all as specified and as directed by the Engr-in-charge.
S&F in repair for chromium plated toilet paper holder complete fixed to wall complete all as specified and as directed by the Engineer-in-Charge. Make : Parryware/Hidware/Prayag or equivalent in makes of Appx 'F' as approved by BOO to be detailed by GE.
Taking down chowkats or frames with shutters area n exe. 1.5 sqm each complete all as specified and as directed by the Engr-in-charge.
Taking down chowkats or frames with shutters area exe. 1.5 Sqm and n.exe 4 sqm each complete all as specified and as directed by the Engr-in-charge.
S&F factory made uPVC white colour Sliding window three track made of extruded profiles with wall thickness of 2.3mm ( +/- 0.2mm). Window profile with hollow section with multi colour chamber, Frame (88mm x 52mm), sliding sash (42mm x 67mm), Sliding mesh sash (42mm x 57mm), Sliding interlock (one vertical length in each shutters) (45.5mm x28mm), Glazing bead (24.5mm x 16mm) will be mitred cut and fusion welded at all corners, including railing of holes for fixing hardware, EPDM gasket. 1.2mm+/-0.2mm thick galvanized steel frame (30mm x18mm), sliding mesh sash (26mm x10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm linf fasteners, Hardware (Touch lock of zinc alloyed (white powder coated), steel roller system, Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and required accessories. ( Note : The unit rate quoted by the the contractor excludes cost of glass and includes all other accessories.) Net opening will be measured for payment purpose.) (A) Area not exceeding 2 .00 Sqm Each
S & F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by the Engr-in-charge.
M&L for 12mm thick prelaminated particle board, , exterier grade (grade-1) confirming IS 14587, fixed with screws for prelaminated both sides with decorative choice laminations complete all as specified and as directed by the Engr-in-charge. complete all as specified and as directed by the Engr-in-charge.
M&L for preparation of old wooden surfaces of any description not other wise decribed over 10 cm width or girth by scrubbing down, removing loose dirt or dust and applying two coats of synthetic enamel paint over prepared old wooden surfaces complete all as specified and as directed by the Engr-in-charge.
M&L for preparation of old surfaces of steel any description over 10 cm width or girth by scrubbing down, removing loose dirt or dust and applying two coats of synthetic enamel paint over prepared old surfaces of steel complete all as specified and as directed by the Engr-in-charge.
M & L for hacking out old broken glass not exc 1.5 sq m (any thickness, size, quality or description) from metal frame including punching or drilling out glazing pins/springs clips and providing and fixing new ones complete all as specified and as directed by the Engineer-in-Charge
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sqm in each pane complete all as specified and as directed by the Engr-in-charge.
S&F in repair for aluminium section of any size as directed for frame / shutter for door, window, ventilator, and all necessary aluminum hinges complete all as specified and as directed by the Engineer-in-Charge.
S&F machine floor closer, floor spring hydaulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, govering pivot, other parts made of mild steel heavy duty complete all as specified and as directed by the Engr-in-charge.
Taking up or down steel tubing and connections 15 mm bore complete all as specified and as directed by the Engr-in-charge.
Taking up or down steel tubing and connections 20 mm bore complete all as specified and as directed by the Engr-in-charge.
S & F GI tubing in 15mm bore med grade with all fittings and fixed complete walls and ceilings or laid in floors complete all as specified and as directed by the Engr-in-charge.
S & F GI tubing in 20mm bore med grade with all fittings and fixed complete walls and ceilings or laid in floors complete all as specified and as directed by the Engr-in-charge.
Cutting in to existing manholes for connecting new drain, making good to pipe 100 mm dia and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and as directed by the Engr-in-charge..
S & F in repair for 15mm bore stop valves, fancy type chromium plated with long shank and cup (consealed) type complete all as specified and as directed by the Engr-in-charge. Make : Jaquar/ Hindware /CERA/ Parryware / MARC
S&F in repair for 15 mm dia angular stop valves of chromium plated with long shank and cup cocealed type screwed down high pressure with crutch or butterfly handle complete all as specified and as directed by the Engineer-in-Charge. Make : Cat part No. ARI 39053 ofJaquar or equivalent in Hindware /CERA/ Parryware / MARC
S&F in repair for chromium plated hand shower ( health faucut) with 8 mm dia 1 mtr long flexible tube and wall hook complete fixed to wall complete all as specified and as directed by the Engineer-in-Charge. Make : Cat part No. OHs-1709 or equivalent in Hindware /CERA/ Parryware / MARC
S&F in repair CP Single towel rack 600 mm long between flanges including brackets complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : AQN-7781 or equivalent in makes of Appx 'F' as approved by BOO to be detailed by GE.
S & F in repair for 15mm bore stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed complete all as specified and as directed by the Engr-in-charge.
S&F in repair for bib tap 15mm dia chromium plated fency type with crutch or butterfly handle screwed down for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge. Make :Jaquar Cat Part No ARI-39037 or equivalent in Hindware /CERA/ Parryware / MARC
S&F in repair CP Single towel rail 20 mm dia D type 600 mm long between flanges including brackets complete all as specified and as directed by the Engineer-in-Charge. Make :Jaquar Cat Part No AQN-7711 or equivalent in Hindware /CERA/ Parryware / MARC
S&F in repair glass sheet assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair 20 mm bore stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed complete all as specified and as directed by the Engr-in-charge.
S & F in repair PVC connections 45 cm Long incl 15mm bore fly nuts on both ends complete all as specified and as directed by the Engr-in-charge.
S&F in repair Vitreous China urinals, Half stall (back to corner wall type), complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) including PTMT urinal spreader for fixing with 15mm dia pipe (min wt 60 gms) complete all as specified and directed Make :Jaquar Cat Part No VRS-WHT-0705 or equivalent in Hindware /CERA/ Parryware / MARC
S&F in repair viterous china white table top wash hand basin with chromium plated waste coupling, waste pipe, PVC connection and all connected fittings complete all as specified and as approved by Engineer-in-Charge. Make - Jaquar Cat Part No FLS-WHT-0539 or equivalent in Hindware /CERA/ Parryware / MARC
S&F in repair brass CP WHB mixer for mixing hot & cold water for 15mm bore dia, pipes, screwed down for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge. Note : for Wash hand basin and wall mixer including all connecting fittings except PVC connection) Make : Jaquar Cat Part No ARI-39001B or equivalent in Hindware /CERA/ Parryware / MARC
S&F in repair 100 mm PVC floor trap with CP grating incl jointing to waste pipe incl fixed in cement concrete type B-1 (1;2:4) complete all as specified and as directed by the Engr-in-charge.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. including cleaning or refixing or removal to Store (measured overall and fixed along the centre line over fittings and accessories) complete all as specified and as directed by the Engr-in-charge.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including clamps in repairs complete all as specified and as directed by the Engr-in-charge.
S&F 110 mm bore PVC (SWR) bends/shoes any radius in repairs complete all as specified and as directed by the Engr-in-charge.
Dismantling of drain pipes rain water pipe jointed in cement mortar and taking out of trenches floor and wall of any size and descsription complete all as specified and as directed by the Engr-in-charge.
S&F for 75 mm PVC (SWR) vent cowl complete all as specified and as directed by the Engr-in-charge.
S&F for 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring with cement joints laid in trench or in floor complete all as specified and as directed by the Engr-in-charge.
Dismantling OH water tank of capacity exc 250 ltrs but not exc 500 ltrs complete all as specified and as directed by the Engr-in-charge.
S&F for 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed by the Engr-in-charge.
S & F for 20 mm dia ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass and fixed complete all as specified and as directed by the Engr-in-charge.
Dismantling for bricks tiles or terracing tiles single layer in roofs complete all as specified and as directed by the Engr-in-charge.
Demolition for mud/mud phuska in roofs any thickness including plastering and leaping if any and cleaning the surfaces with wire brush complete all as specified and as directed by the Engr-in-charge.
M & L for providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in roof kerbs , mud stops or padding as in roof finish ever and fine using WPC complete all as specified and as directed by the Engr-in-charge.
M&L for cement concrete type B-1(1:2:4) using 20mm graded crushed stone aggregate as in coping,roof kerbs or mud stops. Rounded, door cill, hold fast and other like works complete all as specified and as directed by the Engr-in-charge.
ACCESSIBLE ROOF TREATMENTS :-APP TREATMENT WITH BRICK/PCC TILES :-M&L for providing and laying 3mm thick APP (atactric polypropylenepolymer) modified prefabricated five layer weight not less then 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt, make as approved consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25'C temprature and viscosity 70-160 cps over the primer coat, the layer membrane shell be laid using butane troch and sealing all joints etc after preparing the surface complete as per standred practic as per manufactures instructions . The vital physical and chemical parameters of the membrane shell be under ;- (i) Joint strength in longitudinal and transverse direction at 23'C at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150'C when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only . (vi) Brick tiles jointed and pointed in CM1:3 mixed with crude oil shell be provided ( including over a screed of cement (1:6 ) 25 mm thick ) over APP treatment complete all as specified and as directed by the Engr-in-charge. Note : The contractor will carry out ponding test after application of APP treatment before claiming payment.
S&F for 40 mm thick brick tiles laid in CM(1:6) 15 mm thick and jointed flush in CM (1:3) mixed with 5% crude oil by weight of cement complete all as specified and as directed by the Engr-in-charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by the Engr-in-charge.
M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in lintels up to 1.5 m clear span , cills, steps, seismic and other similar band ,plinth course string coureses ,lacing courses parapets and railing up to 60 cm height ,coping , kneelers , apex stone , bed plate water trought and the like including weathering , slightly rounded or chamfered angles complete all as specified and as directed by the Engr-in-charge.
M &L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and as directed by the Engr-in-charge.
M&L for Cement concrete type 1:2:4 type B-1(20mm graded stone aggregate) in surface channels and drains incl necessary formwork complete all as specified and as directed by the Engr-in-charge.
S& F CP nipple with flange fixing as in Bib taps,Stop cock, angle cock etc complete all as specified and as directed by the Engr-in-charge.
M & L for PCC 1:4:8 Type D2 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for providing 100mm thick cement concrete type B-I, 1:4:8 (40mm graded aggregate) complete all as specified and as directed by the Engr-in-charge.
Sand filling under floor or in foundation including watering and consolidation complete all as specified and as directed by the Engr-in-charge.
M&L 80 mm thickness, M-40 grade, machine pressed precast concrete interlocking paver glazed finished coloured block any shape and size conforming to IS 15658-2006, set and jointed with grey cement and pigment complete all as specified and as directed by the Engr-in-charge. Make : NTC/ Surya Kiran /A one /NITCoJ
S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering /cladding to wall fixed with self taping screws complete all as specified and as directed by the Engr-in-charge. Make : JSW/TATA/Bhushan /A one.
S&F framed work of angles or tees with web and flanges cut to shape , drilled and counter sunk for screw , including bending and welding angles as necessary , gusset plates, riveting , etc such as purlin, rafters, post etc confirming to Fe-290 Gde-E-165 complete all as specified and as directed by the Engr-in-charge.
S&F for framed work as in door of angle or other section with gusset plate , rails , braces, etc complete drilled for fixing of steel sheeting or other covering. Door etc, to be prepared hanging or sliding with and including either hooks and hinges or steel hanging door fitting and hanging also fastening and fixing complete all as specified and as directed by the Engr-in-charge.
S & F MS wire netting galvanized with 0.56mm nominal dia of wire & 1.18mm average width of aperture fixed with tinned tacks of wire staples complete all as specified and as directed by the Engr-in-charge.
Prepation of new surfaces of steel any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engr-in-charge.
Excavating in post holes (or similar holes) each not exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface, work in soft/loose soil, complete all as specified and as directed by the Engr-in-charge.
M & L for PCC 1:2:4 Type B2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., quality confirming to GDE Fe 410-S complete all as specified and as directed by the Engineer-in-Charge
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and as directed by the Engr-in-charge.
M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L for hardcore of broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface, complete all as specified and as directed by the Engr-in-charge.
M&L for Paver tiles 10mm thick of size 300x300x10mm thick mm thick set ,jointed and pointed in neat cement slurry as in floors with grey cement and no pigment including 20mm thick cement screed in CM 1:4 complete all as specified and as directed by the Engr-in-charge.
M & L for damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 complete all as specified and as directed by the Engineer-in-Charge
M & L for concrete bed to drain pipes of 100mm bore, including forming cradles in cement concrete 1:3:6 type C-2 complete all as specified and as directed by the Engineer-in-Charge
Supply & fixing vitreus China wash basin white flat back size 580x450mm (for hospital use) excluding taps, waste, chain & plug and porcelain stopper but including brackets and cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe,complete all as specified and as directed by the Engineer-in-Charge
M & L for PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing Grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed by Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) bends of any radius, complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40mm graded aggregate as in sub base of floor complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and as directed by the Engineer-in-Charge
S & F hollow PVC wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing including taking down existing boarding/ panelling complete all as specified and as directed by the Engineer-in-Charge
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed by Engineer-in-Charge.
E/M Schedule
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified and as directed by the Engr-in-charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point controlled by one switch. Note :- Note 1.All chases will be cut by chase cutter only 2.switch, socket and fan regulators to be measured and paid for separately . PVC Conduit confirming to IS 9537 part I & III for One Tube Light point controlled by one switch Make for conduit - Kaliniga Premium/ Prestoplast/ Polycab/Sudhakar. Make for Wire -Havells/Finolex/ Polycab.
One Tube light/ fan point/ batten holder point controled by one one way switch,complete all as specified and as directed by the Engr-in-charge.
One 3 pin 5 Amps socket point controlled by one switch on same board,complete all as specified and as directed by the Engr-in-charge.
One 3 pin 5 Amps socket point controlled by one switch on independent board,complete all as specified and as directed by the Engr-in-charge.
Description All as per item No. 2 here-in-before but with 2.5 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 1.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed by the Engr-in-charge.
Supply and fixing modular switch 16 Amps one way one module 230 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and as directed by the Engr-in-charge. Make::Legrand (Arteor)/ Schenider (Livia) / Hager (Insista) / Panasonic / Crabtree (Havells)
Supply and fixing modular socket 2/3 pin, 6/16 amp,one way 2 module, 230volts complete all as specified and directed by Engineer - in -Charge.. Make:- Legrand (Arteor)/ Schenider (Livia) / Hager (Insista) / Panasonic / Crabtree (Havells)
Takingdown unserviceable submain wiring of any description and M&L for submain wiring alongwith earth wire with 2 x 6.0 Sqmm + 1 x 6.0 Sqmm FRLS-H PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Conduit and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Two runs of 6.0 Sqmm, one run of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length Make for Wire -Havells/Finolex/ Polycab. & Make for conduit - Kaliniga Premium/ Prestoplast/ Polycab/Sudhakar.
Supply and fixing modular switch 6 Amps,1 way 1 module flush type, single pole, 230 volt , AC supply, ISI Marked, complete all as specified and as directed by the Engr-in-charge. Make:Legrand (Arteor)/ Schenider (Livia) / Hager (Insista) / Panasonic / Crabtree (Havells).
Supply and fixing modular socket outlet 2/3 pin 6 amps,one way two module 230 volt. ISI Marked complete all as specified and directed. Make:Legrand (Arteor)/ Schenider (Livia) / Hager (Insista) / Panasonic / Crabtree (Havells)
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed by Engineer - in -Charge... Make:-Anchor / SSK/CONA /Fine.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,including LED Bulb, pin type, 9 watt complete all as specified and as directed by the Engr-in-charge. Make:--Anchor / SSK/CONA /Fine
Supply and fixing fan regulator modular 120 watt, 2 module 230 Volts, 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and directed by Engineer - in -Charge... Make:- -Legrand (Arteor)/ Schenider (Livia) / Hager (Insista) / Panasonic / Crabtree (Havells)
Supply and fix in replacement Batten suitable for LED tube light fitting 1x18 / 20 Watt AC 220-240 Volts, 50 Hz Including tube of 18/20 watt connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete. Make:Philips /WIPRO / Havells/ Osram.
Supply and fixing LED security light 40/45 watt 230 volts 50 Hz including bracket made up of 1.60m long GI pipe, 25mm dia light grade, bent to required length and fixed to wall with two clamps made of 40x6 mm mild steel flat iron 15cm long, 4 Nos 8mm dia bolts with nuts and connecting with 3 core copper conductor flexible cable from terminal box to the ceiling rose or connector of the light point complete all as specified and as directed by the Engr-in-charge. Make ::Philips /WIPRO / Havells/ Osram.
S & F in replacement ultra slim decorative recess mounted LED 36 Watt square 580mmx580mm celling cut out light fitting,height 30mm high efficency diffuser watt 240 volts, 6000K, 50HZ,AC supply,complete all accessiories internally per wired including connecting with 3 core copper conductor flexible cable of size 23/0.0076 from celling rose to connector of the light all as specified. Make : Philips / WIPRO/ Havells/ Osram.
Supply and fixing, testing and commissioning the RCBO for three protection over load protection, Earth leakage protection, and short circuit protection confirming to IEC-61009, 300mA, 2 pole, 230 volts AC 50 Hz, 40 Amps complete all as specified and as directed by the Engr-in-charge. Make - Hager / Legrand/Schnieder/ L&T/ Seimens/ ABB.
supply and fix over and Low voltage release 1 module, 230 volts AC, suitable for single phase adjustabe from 170 volts to 230 volts complete all as specified and as directed by the Engr-in-charge. Make - Make - Hager / Legrand/Schnieder / Siemens/ ABB / L&T.
Supply and fixing, testing and commissioning of MCB SP 6 -40 Amp 240 Volt 10 KA capacity having C-curve characteristics conneted with suitable lugs complete all as specified and as directed by the Engr-in-charge. Make - Hager / Legrand/Schnieder / Siemens/ ABB / L&T.
Supply and fixing, testing and commissioning of MCB SPN 40 Amps 240 Volt 10 KA capacity having C-curve characteristics conneted with suitable lugs all as directed' Make - Hager / Legrand/Schnieder / Siemens/ ABB / L&T.
Supply , insatallation, testing of SPN distibution board 8 way,double door , IP 43 , as per IS 8623 including 100 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles. Make - Hager / Legrand/Schnieder / Siemens/ ABB /L&T.
Supply , insatallation, testing of SPN distibution board12 way,double door , IP 43 , as per IS 8623 including 100 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles. Make - Hager / Legrand/Schnieder / Siemens/ ABB /L&T.
Supply and fixing sheet metal enclosures MCB DB TPN, 4 Ways 8+12 Module way,double door, 415 volts, with and including 200 amps rated bus bar, vertical type IP 43 & Ip 54, Including MCCB TPN 100 Amps as incomer and MCB's as out going with suitable size of MS cabinet 2mm thick and making all type of connections with suitable size of gland for incomer cable complete , concealed on the wall surface, making good the disturbed portion with adjoining surfaces to match with existing finish and taking down the existing DB's and MCB's any type complete all as specified and as directed by the Engr-in-charge. Make - Hager / Legrand/Schnieder / Siemens/ ABB / L&T.
Supply, laid, connecting and testing of LT cable in replacement XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade heavy duty with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and as directed by the Engr-in-charge. Note:-- Connection should be done by contractor and rates including in qoated rates. MAKE - POLY CAB/GLOSTER/HAVELLS/ Finolex.
Excavation in trenches n exc 1.5 m wide and not exc 1.5m in depth for foundation etc or for shafts, well cessplits,manholes etc and getting out in soft /loose soil complete all as specified and as directed by the Engr-in-charge.
Returning filling in including spreding leveling watering and well ramming in layers not exc 25 cm each in soft/loose soil complete all as specified and as directed by the Engr-in-charge.
Removing excavated materials to a distance not exc 50 m and depositing where directed at level n exc 1.5 above the starting points complete all as specified and as directed by the Engr-in-charge.
M & L filling spreading sand (dry) un-washed free from shop particles around cable as cushiong complete all as specified and as directed by the Engr-in-charge. Note : Punned thickness of sand layer shall be paid to contractor.
Supply and laying un-reinforced precast concrete cable cover,class LV type 1, Flat ,size 250 mm x150 mm x40 mm complete all as specified and as directed by the Engr-in-charge.
Supplying and fix in replacement light grade GI tubing of size 40 MM dia for cable protection and fixed with clamp to pole and wall complete all as specified . Make:- JINDAL/TATA/Zeinth.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to galvanised iron wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed including taking down unserviceable earthing. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Taking down ceiling fan,sealing cableend, dismantling blades and removing fan including painting of ceiling fans with syenthyic paint by spraying incl filling cavaties with filler , on coat after cleaning all dust etc.
M&L for fixing the ceiling fan and connecting up including provision of flexible cable23/.0076 from ceiling rose or connector to fan.
Swami Enterprises
M/s Vridhi Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .