Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC 1 1 AMRABATI APARTMENT MAHESHTALA MAHESHTALA KOLKATA WEST BENGAL 700141 | 24 PARAGANAS SOUTH | WEST BENGAL | 700141 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹41.9 L+₹4.1 L (10.8%)Rejected-AOC SARDARPURA 1ST B ROAD NEAR HANUMAN JI KA MANDIR JODHPUR RAJASTHAN 342 003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L2 | Rejected-AOC Not lowest |
Tender Value
Refer Docs
EMD Value
₹54,900
Closing Date
3 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jodhpur
GE (AF) Jodhpur
PROVN OF CERTAIN SANCTIONED WORKS AT AF STN JODHPUR AND SALAWAS UNDER GE AF JODHPUR
2020_MES_374523_1
8419/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹54,900
Yes
15 Oct 2020
3 Sept 2020
5 Oct 2020
3 Sept 2020
3 Oct 2020
21 Sept 2020
60 days
Amount
Supply & fixing rotational moulded polyethylene water storage tank of capacity 1000 litre (Cylindrical vertical with closed top), triple layer construction, white coloured, ISI marked, hoisted & fixed in position including 20 mm dia GI light grade overflow pipe 450 mm long and 20 mm dia GI waste pipe 600 mm long with all fittings complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 15 mm bore GI tubing medium grade with all fittings fixed to walls, ceiling or laid in floors/trenches complete all as specified and as directed.
Supply & fixing 20 mm bore GI tubing medium grade with all fittings fixed to walls, ceiling or laid in floors/trenches complete all as specified and as directed.
Supply & fixing 15 mm gun metal, globe or gate valve, with half turn lever arm/ iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-Charge
Supply & fixing 20 mm gun metal, globe or gate valve, with half turn lever arm/ iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-Charge
Supply & fixing 15 mm dia bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 20 mm dia bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe [Minimum weight for 20 mm – 210 gms] complete all as specified and as directed by Engr-in-Charge
Material & labour for squared rubble walling, Jodhpur type, brought to courses and regular coursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by the Engineer-in-Charge.
Material & labour for cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in coping, bed blocks, lintels, clls steps etc and like including necessary formwork and finishing surface fair and even without using extra cement complete all as specified and as directed by the Engr-in - Charge.
Surface excavation not exceeding 30cm deep & averaging 15 cm deep and getting out in soft / loose soil complete all as specified & directed by the Engineer-in-Charge.
Removing excavated materials (soils) to a distance exceeding 250 mtr but not exceeding 500 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed by the Engineer-in-Charge.
Material & labour for excavation in post holes (or similar holes) in soft/ loose soil each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified & directed by the Engineer-in-Charge.
Material & labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, filling in and mass concrete complete all as specified & directed by the Engineer-in-Charge.
Material & labour for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in post holes complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing mild steel work Fe-410 (Gde-E-250) quality -A in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing Pre- painted galvalume GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing Pre- painted galvalume GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 50 mm thick, PCC 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate), as in sub floors, surface finished even and smooth without using extra cement complete all as specified & directed by the Engineer-in-Charge.
Material & labour for rendering in cement mortar (1:4), 15mm thick on stone masonry or surface other than fair faces of brick work and finishing the surface even and smooth without using extra cement complete all as specified and as directed by the Engr-in - Charge.
Material & labour for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint, white or tinted over a coat of alkali resistant primer complete all as specified and as directed by Engineer-in-Charge.
Material & labour for preparation of new steel surfaces over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer primer complete all as specified & directed by the Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by the Engr-in - Charge.
Supply & fixing mild steel framed work such as grills, grating etc with ends of bar shouldered, framework of water tank/MH cover frame work and similar work confirming to Fe.290.Gde-E-165 complete all as specified & directed by the Engineer-in-Charge.
Surface excavation not exceeding 30cm deep & averaging 15 cm deep and getting out in hard/dense soil complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 100 mm thick, PCC 1:4:8, type D-2, (using 40 mm graded crushed stone aggregate), as in sub base of floor’s complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 80 mm thick Machine pressed ruberised precast conctete interlocking paver block of M-40 Grade, with 6 mm top layer of anti abrasive material, any shape and size confirming to IS 15658-2006, with grey cement and pigment complete all as specified & directed by the Engineer-in-Charge.
Material & labour for providing cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) in kerb stone setting in cement mortar 1:4, as in edging of interlocking paving block complete all as specified and as directed by the Engr-in - Charge.
Removing excavated materials (soils) to a distance exceeding 1.5 km but not exceeding 5 km and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 25mm thick sand filling under floors or in foundations including watering and consolidation complete all as specified & directed by the Engineer-in-Charge.
Excavating over areas, not exceeding 1.5 m deep and getting out in hard/dense soil complete all as specified and as directed by Engr-in-Charge.
Excavating over areas, exceeding 1.5 m deep but not exceeding 3 meter deep and getting out in hard/dense soil complete all as specified and as directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified & directed by the Engineer-in-Charge.
Demolition of stone/ boulder masonry or brick work, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & directed by the Engineer-in-Charge.
Material & labour for RCC 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified & directed by the Engineer-in-Charge.
Material & labour for RCC 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified & directed by the Engineer-in-Charge.
Material & labour for formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter, for flat rough finished surfaces of concrete complete all as specified & directed by the Engineer-in-Charge.
Material & labour for formwork to sides of pillars, posts, struts, piers,columns, and stanchions; for rough finished surfaces of concrete, circular or octagonal shape of column on plan complete all as specified & directed by the Engineer-in-Charge.
Material & labour for TMT Bars 10 mm dia & over, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified & directed by the Engineer-in-Charge.
Material & labour for TMT Bars 5mm dia and over upto and including10 mm dia, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.90 mm dia as in stirrups complete all as specified & directed by the Engineer-in-Charge.
Material & labour for rendering 10mm thick on concrete surface in cement mortar (1:4) and finishing the surface even and smooth without using extra cement complete all as specified and as directed by the Engr-in - Charge.
Material & labour for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint, white or tinted complete all as specified and as directed by Engineer-in-Charge.
Material & labour for MS Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe 410-W (GdeE- 250) quality-A complete complete all as specified and as directed.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm and dressing face beds and joints as specified to squared rubble walling, Jodhpur type, brought upto courses complete all as specified and as directed.
Material & labour for hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed
Material & labour for 100 mm thick, PCC 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate), as in floor in alternate bays complete all as specified & directed by the Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
Material & labour for forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade -B complete all as specified & directed by the Engineer-in-Charge.
Material & labour for forming Contraction (Dummy) joint 65mm deep x 10mm wide filled with sealing compound grade -B complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 100 mm thick, PCC 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate), as in floor in alternate bays including providing broom finished surface of concrete pavement while concrete is green complete all as specified & directed by the Engineer-in-Charge.
Removing demolished building material etc. to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing Collapsible steel gates, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified & directed by the Engineer-in-Charge.
Material & labour for cutting holes exceeding half brick but not exceeding one brick in stone walls built in cement mortar for inserting holdfasts & making good dismantled portion in cement mortar (1:3) or in PCC(1:2:4) Type B-1 (using 20 mmm graded stone aggregate) as required complete all as specified and as directed by Engr-in-Charge .
Material & labour for rendering in cement mortar (1:6), 15mm thick on stone masonry or surface other than fair faces of brick work and finishing the surface even and smooth without using extra cement complete all as specified and as directed by the Engr-in - Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0 sqm each and removing from site complete all as specified and as directed by Engr-in-Charge.
Taking down cement or cement lime plaster work any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 25 mm thick, PCC 1:2:4, type B-0, (using 12.5 mm graded crushed stone aggregate), as in sub base for tiles in floors complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Glazed Vitrified tiles (GVT) of size 600mm x 600mm x 10 -12 mm (Non skid/Matte) (square) coloured, as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-Charge.
Material & labour for Glazed Vetrified tiles (GVT) glossy finish, of size 600mm x 300mm x 10 -12 mm in vertical surfaces as in skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-Charge.
Supply & fixing anodised aluminium door shutters, powder coated (Thickness or powder coating not less than 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing Anodised aluminium frame for doors, windows, ventilators, coloured powder coated (Thickness or powder coating not less than 50 micron), with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engr-in-Charge.
Supply & fixing 5.5 mm thick sheet glass ordinary quality and glazing with aluminium beading, in square exceeding 0.50 sqm in each pane complete all as specified and as directed by Engr-in-Charge
Supply & fixing Aluminim anodised barrel tower bolt 125 mm long extruded section complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 200mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing cast iron body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851mm to 1000 mm in width & of weight between 61kg to 80kg complete all as specified and as directed.
Supply & fixing floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring with overall length of cover plate 140 mm, fixed in floor complete all as specified and as directed.
Material & labour for prepration of new plastered surface of walls and applying 3 mm thick white cement based wall care putty finished even and smooth with sand paper and apply two coats of oil emulsion distemper white or tinted complete all as specified & directed by the Engineer-in-Charge
Supply & fixing Anodised aluminium snap grid of size 605mm x 605 mm frame work for false ceiling complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 12 mm thick Perforated particle boards for insulation and accoustic purposes, 60x60 cm in size, fixed with screws to timber frame work or withstaples on snap grid complete all as specified & directed by the Engineer-in-Charge.
Material & labour for PCC 1:1.5:3, type A-1, (using 20 mm graded crushed stone aggregate), surface finished even and smooth without using extra cement complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing mild steel work Fe-410 (Gde-E-250) quality -B in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified & directed by the Engineer-in-Charge.
Dismantling framed truss of span not exceeding 10.00 meter complete all as specified & directed by the Engineer-in-Charge.
Fabrication, erection and fixing only mild steel work Fe-410 (Gde-E-250) quality -B in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified & directed by the Engineer-in-Charge.
Material & labour for preparation of old steel surfaces over 10cm girth or width, and applying two coats of synthetic enamel paint complete all as specified & directed by the Engineer-in-Charge.
Material & labour for preparation of new plastered surfaces of walls, and applying two coats of white wash complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 125 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing Aluminim anodised barrel tower bolt 150 mm long extruded section complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing floor 75 mm long door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and as directed.
Supply & fixing 18 mm thick solid UPVC ply of 1st quality of one side prelaminated of approved colour and one side white colour fixed with screws, solvent cement/adhesive to make cabinet and cup board shutters complete all as specified and as directed.
Supply & fixing 18 mm thick UPVC coated ply of grade 1 quality of both white colour fixed with screws, solvent cement/adhesive to make MAP cabinet with racks/CBs shutters etc complete all as specified and as directed.
Supply & fixing sliding telescopic channel high grade mild steel, bright finish or electrogalvanised as per approved sample complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing stainless steel handle of 150 mm size as per approved sample complete all as specified and directed by the Engineer-in-Charge.
Supply and installation of UPVC window fixed type with double glazed unit, all glasses toughened to achieve 60 dBA of sound reduction. The UPVC profile tested for 8000 hours against light UV material mix. The UPVC outer wall profile will be 2.5 mm thick to ensure the weld strength consedering heavy glass panels. Gasket to be black colour EPDM. All hardware spang rods to be stainless steel 304 grade. the fabricator to be certified with ISO 9001-2008 and audited by third party for quality system. Noise reduction of 60dBA will be assured from window opening complete all as specified and directed by the Engineer-in-Charge.
Supply and installation of UPVC door/window frame with double shutters with openable panels with double glazed unit, all glasses toughened to achieve 60 dBA of sound reduction. The UPVC profile tested for 8000 hours against light UV material mix. The UPVC outer wall profile will be 2.5 mm thick to ensure the weld strength consedering heavy glass panels. Gasket to be black colour EPDM. All hardware spang rods to be stainless steel 304 grade and locking arrangements. the fabricator to be certified with ISO 9001-2008 and audited by third party for quality system. Noise reduction of 60dBA will be assured from door/window opening complete all as specified and directed by the Engineer-in-Charge.
Material & labour for site clearance in soft/loose soil complete all as specified & directed by the Engineer in Charge.
Excavating over areas, not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed by Engr-in-Charge.
Excavating over areas, exceeding 1.5 m deep but not exceeding 3 meter deep and getting out in soft/loose soil complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out complete all as specified and directed by the Engineer-in-Charge.
Material & labour for pre-cast cement concrete block masonry (1:2:4), type B-1 (using 20mm crushed stone graded aggregate), with solid blocks, exceeding 10cm in width and setting in cement mortar 1:6 complete all as specified & directed by the Engineer-in-Charge.
Material & labour for pre-cast cement concrete block masonry (1:3:6), type C-1 (using 20mm crushed stone graded aggregate), with solid blocks, not exceeding 10cm in width and setting in cement mortar 1:6 complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Stone slab 25 mm to 35 mm thick dressed true and square, in one length not less than 60cm and not exceeding 120cm in copings, window cills, chajjas, sunshades, etc., punched dressed on exposed faces and self faced on the embedded unexposed beds and joints; exposed edges rounded or chamfered as directed, set, jointed and pointed in mortar in cement mortar 1:4 complete all as specified and directed by the Engineer-in-Charge.
Material & labour for cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in roof kerbs or mud stops rounded or chamfered on edges complete all as specified and as directed by the Engr-in - Charge.
Material & labour for formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc, for flat rough finished surfaces of concrete complete all as specified & directed by the Engineer-in-Charge.
Material & labour for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping), for flat rough finished surfaces of concrete complete all as specified & directed by the Engineer-in-Charge.
Material & labour for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified and directed by the Engineer-in-Charge
Material & labour for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete complete all as specified and directed by the Engineer-in-Charge
Material & labour for RCC nominal mix, 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate) as in chhajjas complete all as specified & directed by the Engineer-in-Charge.
Material & labour for RCC nominal mix, 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintel over 1.5 m span etc complete all as specified & directed by the Engineer-in-Charge.
Material & labour for RCC nominal mix, 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 75 mm thick, PCC 1:4:8, type D-2, (using 40 mm graded crushed stone aggregate), as in sub base of floors including finishing the surface even and fair complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 15 mm thick rendering in Cement Mortar 1:4 with and including water proofing compound at 3% by weight of cement on concrete surfaces while concrete surface is green on roof, finishing even and smooth without using extra cement complete all as specified & directed by the Engineer-in-Charge. Note:- Water proofing compound shall be measured and paid seperately as supply only.
Material & labour for rendering 10mm thick on concrete surfaces of walls or fair faces of brickwork in cement mortar (1:4), finished even & smooth (without using extra cement) complete all as specified and as directed by the Engr-in - Charge.
Material & labour for 15 mm thick rendering in Cement Mortar 1:4 with and including water proofing compound at 3% by weight of cement on concrete surfaces of walls or fair faces of brickwork finishing even and smooth without using extra cement complete all as specified & directed by the Engineer-in-Charge. Note:- Water proofing compound shall be measured and paid seperately as supply only.
Material & labour for rendering 5 mm thick on fair faces of concrete surfaces of ceilings, in cement mortar (1:4), finished even & smooth (without using extra cement) complete all as specified and as directed by the Engr-in - Charge.
Material & labour for rendering 15 mm thick on concrete surfaces of walls or fair faces of brickwork in cement mortar (1:4), surface finished even & fair or rough for tile finishes complete all as specified and as directed by the Engr-in - Charge.
Supply only water proofing compound complete all as specified and directed by the Engineer-in-Charge.
Material & labour for screed bed/ bedding layer of 15mm thick in cement mortar 1:4 for laying floor finishes etc, complete all as specified & directed by the Engineer-in-Charge.
Material & labour for coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by the Engr-in - Charge.
Material & labour for glazed ceramic coloured tiles of approved design pattern of size 450mm x 350mm x 7 mm thick in vertical surfaces, set and jointed in neat cement slurry & pointed in white cement mixed with pigment to match with colour of tiles, complete all as specified and as directed by Engr-in-Charge.
Material & labour for preparation of new plastered surfaces of walls, and applying three coats of white wash complete all as specified & directed by the Engineer-in-Charge.
Material & labour for preparation of new plastered surfaces of ceilings, and applying three coats of white wash complete all as specified & directed by the Engineer-in-Charge.
Material & labour for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint, over and including a coat of white cement complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing coloured powder coated (Thickness or powder coating not less than 50 micron), Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no) hinges type B-21 100mm long (2 no) suitable handle (1 no) complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and as directed.
Supply & fixing 4 mm thick sheet glass ordinary quality and glazing with oil putty or fixed with rubber gasket, in square not exceeding 0.50 sqm in each pane complete all as specified and as directed by Engr-in-Charge
Supply & fixing Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube with 75 mm long MS screws with PVC fasteners to wall including reoair to jams of wall and finishes complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed.
Supply & fixing anodised aluminium handles 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by the Engineer-in-Charge.
Material & labour for 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 125 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring with overall length of cover plate 150 mm, fixed in floor complete all as specified and as directed.
Supply & fixing Hard drawn steel wire fabric, weight not less than 4 kg /sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia in reinforcemnt complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed Complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 1.6 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as requiredcomplete all as specified & directed by the Engineer-in-Charge.
Material & labour for screed bed/ bedding layer of 20mm thick in cement mortar 1:6 for laying floor finishes etc, complete all as specified & directed by the Engineer-in-Charge.
Material & labour for screed bed/ bedding layer of 15mm thick in cement mortar 1:6 for laying floor finishes etc, complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 20-25 mm thick machine cut kota stone slab flooring with Kota stone of size 550mm X 450 mm / 550X550mm , laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and mirror polishing to he entire satisfaction of Engineer-in-Charge.
Material & labour for 20-25 mm thick machine cut kota stone slab as in steps, skirting, dado and pillar , laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and mirror polishing to he entire satisfaction of Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling /terrazo including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified & directed by Engineer-in-Charge.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified & directed by Engineer-in-Charge.
Taking down old tarfelt of exiting water proofing treatment on RCC roof surfaces including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. removing all debris from site to out side of the defence land complete all as specified & directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and removing from site complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15 mm bore pipe and connection including cleaning for re-fixing or removal to store complete all as specified & directed by the Engineer-in-Charge.
Taking up or down steel tubing of 20 mm bore pipe and connection including cleaning for re-fixing or removal to store complete all as specified & directed by the Engineer-in-Charge.
Dismantling old unserviceable water tanks of capacity exceeding 250 litres but not exceeding 500 litres and removing to store complete all as specified & directed by Engineer-in-Charge.
Material & labour for rendering in cement mortar (1:4), 15mm thick on stone masonry or surface other than fair faces of brick work and finishing the surface even and fair as in backing coat complete all as specified and as directed by the Engr-in - Charge.
Material & labour for acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors complete all as specified and directed by the Engineer in Charge.
Material & labour for 75mm thick PCC 1:3:6, type C-2, (using 40mm graded crushed stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, laid in panels not exceeding 3 meter long and joints shall be filled with mixture of bitumen and sand in 1:3 by weight complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 15 mm thick rendering in Cement Mortar 1:4 with and including water proofing compound at 3% by weight of cement on stone masonry or surface other than fair faces of brick work, finishing even and smooth without using extra cement complete all as specified & directed by the Engineer-in-Charge. Note:- WPC shall be measured and paid seperately as supply only.
Material & labour for approved colour powder coated (Thickness or powder coating not less than 50 micron) window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coating aluminium snap beading ,screws etc & including fixed in position star locks, rollers for sliding complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 4 mm thick sheet glass ordinary quality and glazing with oil putty or fixed with rubber gasket, in square exceeding 0.50 sqm in each pane complete all as specified and as directed by Engr-in-Charge
Supply and Fixing in repair IInd class hard wood beads , straight (any size) for glazed or gauzed joinery , renewed including mitres etc complete all as specified and as directed by Engineer in Charge.
Supply and Fixing aluminium door sealed strip of size not less than 30mm wide in bottom of door complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing Aluminim anodised barrel tower bolt 200 mm long extruded section complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing anodised aluminium handles 200mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by the Engineer-in-Charge.
Material & labour for preparation of old decorated surfaces on ceiling. including brooming, scraping down. Smoke spot, moss, efflorescent salts, trading oil, greasy spots and stopping nails marks by applying white cement base putty in patches as required and one coat of white wash on ceilings complete all as specified & directed by the Engineer-in-Charge.
Material & labour for prepration of new plastered surface of walls and applying two coats of white cement based wall care putty finished even and smooth with sand paper and apply two coats of oil emulsion distemper white or tinted over a coat of alkali resistant primer complete all as specified & directed by the Engineer-in-Charge
Material & labour for prepration of old plastered surface of walls and applying two coats of white cement based wall care putty finished even and smooth with sand paper and apply two coats of oil emulsion distemper white or tinted over a coat of alkali resistant primer complete all as specified & directed by the Engineer-in-Charge
Material & labour for preparation of new plastered surfaces of wall and applying two coats of exterior weather proof water based emulsion paint over a coat of primer of same make on walls complete all as specified & directed by the Engineer-in-Charge. (Make : Asian- Apex / Burger -weather coat)
Material & labour for removel of old existing treatment surfaces of walls and applying white cement based wall care putty in patches as required on walls finished even and smooth with sand paper and applying two coats of exterior weather proof water base emulsion paint over a coat of primer of same make complete all as specified & directed by the Engineer-in-Charge. (Make : Asian- Apex / Burger -weather coat )
Refixing of 15mm bore old steel tubing & connection in new or old position provided in walls, ceilings and floors etc complete all as specified and directed by the Engineer-in-Charge.
Refixing of 20mm bore old steel tubing & connection in new or old position provided in walls, ceilings and floors etc complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs of brass Chromium plated angle Stop valves of 15mm bore screwed for 15mm bore iron pipe or union complete all as specified & directed by the Engineer-in-Charge. Make - MARC/ Jaquar (ESSCO)/ Prayag
Supply & fixing in repairs 15 mm dia bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and as directed by Engr-in-Charge
Supply & fixing in repairs PVC Flexible waste pipe 32 mm dia with socket for steel sink upto floor level and length not less than 600 mm complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing rotational moulded polyethylene water storage tank of capacity 500 litre (Cylindrical vertical with closed top), triple layer construction, white coloured, ISI marked, hoisted & fixed in position including 20 mm dia GI light grade overflow pipe 450 mm long and 20 mm dia GI waste pipe 600 mm long with all fittings complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs 20 mm dia bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe [Minimum weight for 20 mm – 210 gms] complete all as specified and as directed by Engr-in-Charge.
Supply & fixing in repairs 20 mm gun metal, globe or gate valve, with half turn lever arm/ iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-Charge.
Supply & fixing 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with clamps complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing PVC (SWR) bend any radius of 110 mm bore complete all as specified & directed by the Engineer-in-Charge.
Material & labour for brushing neat cement slurry with 3.0 kg of cement per square metre complete all as specified and as directed by the Engr-in - Charge.
Material & labour for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in levelling course with water proofing compound, finished even and fair on roof/chajjas etc complete all as specified and as directed by the Engr-in - Charge.
Material & labour for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 with water proofing compound as per manufacture instruction complete all as specified and as directed by the Engr-in - Charge.
Material & labour for preparation of concrete surface for appying bituminous primer (conforming to IS : 3384-1965) @ 0.40 Kg/Sqm complete all as specified and as directed by Engineer-in-Charge.
Material & labour for applying evenly a tack coat of industrial bitumen grade of 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces (Ist coat for bonding material below membrane and IInd coat on top of membrane. Each coat will be measured seperately) complete all as specified & directed by the Engineer-in-Charge.
Material & labour for APP modified polymeric membrane, centre core of 100 micron HMHDPE, Outer film 20 micron each , thickness not less than 3.00mm , having weight minimum 3.00 kg / Sqm laid on primed surface by forced application and finally finished with aluminium paint @ 0.20 Ltr per sqm complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 10 mm thick rendering in cement mortar 1:4 with WPC @ 3% by weight of cement on concrete surfaces while concrete surface is green on roof, finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. Note:- WPC shall be measured and paid seperately as supply only.
Taking down and re-fixing old aluminium door shutters in same opening with necessary required repairs and fittings including glass rubber beading and glazing clips (Glass pan and wire gauge will be measured and paid separately), area exceeding 2.00 sqm but not exceeding 4.00 sqm each complete all as specified & directed by the Engineer-in-Charge.
Taking down and re-fixing of old aluminium window in same opening with necessary required repairs and fittings including glass rubber beading door frame and glazing clips (Glass pan and wire gauge will be measured and paid separately), area not exceeding 2.00 sqm each complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing 2nd class hardwood, clean sawn boards of planks, width not exceeding 20cm, 30 mm thick complete all as specified and as directed by Engr-in-Charge.
Material & labour for flush pointing in cement mortar 1:4 to random rubble masonry, uncoursed or brought upto courses complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches in hard/dense soil, not exceeding 1.5m wide and not exceeding 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches in soft/disintegrated rock, not exceeding 1.5m wide and not exceeding 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out complete all as specified and directed by the Engineer-in-Charge.
Material & labour for precast reinforced cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) for manholes covers set in cement mortar 1:6 including necessary formwork moulds complete all as specified and as directed by the Engr-in - Charge. Note:- Reinforcement shall be measured and paid seperatelly under respective item of BOQ
Material & labour for cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in surface channels, drains complete all as specified and as directed by Engr-in-Charge.
Material & labour for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped endsetc. complete all as specified and as directed by Engr-in-Charge.
Demolition and breaking up 150 mm bore drain pipes, soil , waste and rain water pipes etc (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, in trenches or floors, including connections and fittings, haunching and bed concrete complete all as specified and directed by the Engineer-in-Charge.
Material & labour for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of size 150 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 150mm dia salt glazed stoneware pipe grade 'A' (ISI marked) laid to slope in trenches and jointed in cement mortar 1:1 including testing complete all as specified and directed by the Engineer-in-Charge.
Material & labour for cutting into existing manholes for connecting new drains of 225mm internal dia pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( ½ round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed by the Engineer-in-Charge.
Cleaning of manhole of any description & size, not exceeding 0.75 metre in depth including lifting up and removing sludge and any other foreign material by any mechanical means and washing down with water for smooth functioning of sewage line upto the entire satisfaction of engineer in charge complete all as specified and directed. Note:- Sludge obtained from cleaning shall be removed and disposed off properly outside MD Land
Material & labour for cleaning/clearing of blocked under ground sewage lines of any bore, any description and in any position, depth not exceeding 1 metre , by taking out loose sediment sand, grit, ash, sludge, rags, fibres, vegetation etc by rodding/ any mechanical means, from one manhole to next manhole and washing throughout with fresh water including removing all sludge from the sewage lines in covered vans, trolley and disposed off properly outside the MD land upto the entire satisfaction of engineer in charge complete all as specified and directed
Material & labour for construction of new stone masonry soakage well 1.8 metres dia and 3.0 metres effective depth complete all as shown on drg No CEAA/TD/80 SHEET 1/2 & 2/2 and as specified & directed by the Engineer in Charge.
Material and Labour for provision of RCC Precast Readymade Septic Tank cylindrical in shape of 600mm diameter and 2.40 meters length for 10 users capacity , made of reinforced cement concrete consisting 3 chambers, 2 manholes with RCC manhole covers, inlet & outlet and also has provision for gas pipe with and including provision of excavation and earthwork in any type of soil, removal of surplus excavated material up to distance exceeding 50 metre but not exceeding 100 metre, bedding Concrete shall be 150mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregates), Cast Iron spun vent pipe centrifugally cast 100mm bore conforming to IS : 3989 with CI fitting/accessories , Top of CI pipe shall be provided with CI cowl jointed with cement joint, Inlet and outlet pipe shall be 150mm bore SWG grade ‘A’ up to 1 metre beyond external face of wall, including packing under, and haunching against the sides of septic tank after the same laid and tested with PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) complete all as specified and directed by the Engineer in Charge.
Material & labour for sub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 6 Sqmm 1100 volt grade and through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm,concealed in wall (including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc.) including 4 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire Complete all as specified and directed by the Engineer-in-Charge. Note :- Two runs of main wire with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Material & labour for shifting of AC any type and capacity, from one location to another location including complete wiring, replacement of copper tubing with provision of complete insulation and leakage and testing after installation complete in all respect and as directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete including one single pole 240 volt MCB, C-curve, 25 amps complete all as specified and as directed by the Engineer-in-Charge.
Material & labour for filling of refrigerant R-22/ R-410/ 407A complete all as specified & directed by the Engineer-in-Charge.
Material and Labour for point wiring on independent board with 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS) 1100 volts grade drawn through and including 20mm dia PVCcasing/caping (ISI marked) with all accessories including surface/concealed sheet steel terminal/ CI box with 3 mm thick plastic laminated sheet top cover including 1.5 Sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor to common earth and connecting to earth dolly complete all as specified and directed by the Engineer-in-Charge
Supply and fixing switch piano flush type single pole one way, 16 Amp (ISI marked) complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Socket outlet 2 in 1, 5 pin 16 Amps complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for point wiring for one light/fan/exhaust fan with 1.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS) 1100 volts grade drawn through and including 20mm dia PVCcasing/caping (ISI marked) with all accessories including surface/concealed sheet steel terminal/ CI box with 3 mm thick plastic laminated sheet top cover including 1.5 Sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor to common earth and connecting to earth dolly complete all as specified and directed by the Engineer-in-Charge
Ditto all as per Item Ser No 195 Above but for 3 pin 5 Amp socket outlet on indepedent board with other switches
Supply and fixing switch piano flush type single pole one way, 5 Amp (ISI marked) complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Socket outlet 2 in 1, 3 pin 5/15 Amps complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing ceiling rose white coloured surface bakelite 65 mm x 20mm, two to three terminals ISI (Marked) complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing Self closing taps 15 mm bore of cast iron or malleable cast iron, galvanised, screwed for iron pipe and fixed complete all as specified and as directed
Material & labour for test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw. As required with all accessories complete all as specified and directed by the Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed
Material and Labour for point wiring for one light/fan/exhaust fan controled by one switch 5 amps one way, with 1.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed single core multistranded copper conductor cable (using colour code as per IS) 1100 volts grade drawn through and including 20mm dia PVC conduit of minimum thickness 1.8 mm concealed in wall including pressed steel terminal sunken boxes with 2 mm thick plastic laminated sheet for mounting modular switches, sockets, regulator etc including 1.5 Sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor to common earth and connecting to earth dolly complete all as specified and directed by the Engineer-in-Charge
Ditto all as per Item Ser No 203.00 Above but for 5 Amp socket on same board.
Ditto all as per Item Ser No 203.00 Above but for 5 Amp socket outlet on independent board.
Ditto all as per Item Ser No. 203.00 above but with 2.5 Sqmm cable for one 15 Amps socket outlet on independent board with 1.5 Sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor complete all as specifed and directed
Supply and fixing modular switch single pole one way, 5 Amp (ISI marked) complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing modular socket outlets 6 Amps 2/3 pin 230 V AC combined 2 module complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing modular socket outlets 6/16 Amps 2/3 in one pin 230 V AC combined 2 module complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing modular switch single pole one way, 16 Amp (ISI marked) complete all as specified and directed by the Engineer-in-Charge.
Taking down MCB DB any type and any size complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing DB TPN 4 way IP-43 protection double door fixed on wall with incoming MCCB TPN 100 Amps 16 KA-01 No and outgoing MCB SP 6-32 Amps C curve type 10 numbers including necessary connections complete all as specified and as directed
Supply and fixing stepped type modular fan regulator ISI marked with 02 module complete all as specified and directed by the Engineer-in-Charge.
Taking down old tube light/sketch/bul head any type for replacement/refixing and making good the disturbed surface complete all as specified and as directed
Supply and fixing LED light fitting 1x20 Watt box type alongwith all fittings and accessaries like LED rod etc fixed to wall/ceiling with 0.5 sqmm three core copper wire complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED security 90 watt IP 65 with required size of GI pipe and necessary fittings for connections complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing air circulator fan 230 V single phase heavy duty, oscillating 450 mm sweep, suitable for wall mounting and all accessories needed for fixing complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing exhaust fan AC single phase 230/240 V of size 450 mm sweep with louver complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing ceiling fan with electronic type regulator and accessories, 230 V, 1200 mm sweep complete all as specified and directed by the Engineer-in-Charge.
Material & labour for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including earth lead of copper strip 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe up to 7.5m. Note : This Item includes the cost of GI earth lead and GI protection pipe up to 7.5metres. Beyond 7.5m copper earth lead and GI pipeshall be measured and paid for separately.
Taking down carefully Heat/Smoke Detector, response indicator, fault isolator from existing roof and keep in safe custody including connected wiring cables etc complete all as specified and directed by the Engineer-in-Charge.
Refixing the Heat/Smoke Detector, response indicator, fault isolator including refixing of wiring after completion of civil work and testing of the same in presense of User and MES Rep complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing factory made MCB DB VTPN 4 way, 240 V double door, IP-43 protection system, having 200 Amps 2 Nos bus bar for neutral and earth bus bar fixed/concealed on wall including necessary connections lugging with copper lugs pin/ring type complete all as specified and as directed
Supply & fixing MCB 6 to 32 Amps Single pole 10 KA rating, 'C' curve type complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing MCB 100 Amps four pole 10 KA rating, 'C' curve type 240/415 V, 50 Hz complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing MCB 63 Amps four pole 10 KA rating, 'C' curve type 240/415 V, 50 Hz complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing Air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing track for LED focus light, 1.0 meter long with necessary cable connections complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing LED track mounted focus light, 20 watt warm white with necessary cable connections complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing modular white cover plate with frame 12 modular complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing modular white cover plate with frame 6 modular complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing single pointed air termination aluminium rod 12 mm dia 300 mm long complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 40 mm bore GI tubing medium grade, 1.5 meter long complete all as specified and as directed.
Supply and fixing aluminium strip of size 25 mm x 3.15 mm with saddles and fixing screws etc for roof conductors above ground complete all as specified and directed by the Engineer-in-Charge
Material and labour for PCC block of size 150 mm x 150 mm x 300 mm, made ou of PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) for fixing/mounting of running earthing conductor complete all as specified and directed by the Engineer-in-Charge
Supply and fixing copper strip of size 20 mm x 3 mm complete with protection sleeve, saddles, seperator and fixing screws at sorrounding inside and outside the building complete all as specified and directed by the Engineer-in-Charge
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 95 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 70 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor complete all as specified by Engineer-in-Charge.
Removing excavated materials (soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed by the Engineer-in-Charge.
Material & labour for stone slab 40 mm to 50 mm thick rough dressed Jodhpur stone patties/ slab cover in trenches for protection of cable 25 cm to 30 cm wide and not less than 50 cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning complete all as specified and directed by the Engineer-in-Charge.
Material & labour for sand cushioning for PVC cable with screened & washed sand & punning to provide a required cover complete all as specified and directed by the Engineer-in-Charge. Note:- Punned thickness only shall be measured and paid.
Material & labour for earthing complete with galvanised steel earth electrode 60cm x 60cm x 6.3 mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 25mm x 4 mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
Material & labour for out door type LT Feeder Pillar (Kiosk) of size not less than L=60 cmx 45 cm x45 cm (H) made out 3.15 mm thick CRCA sheet (CPRI approved) with openable Front door including locking arrangement with and inluding Copper Busbar 200 amps rating with one MCCB 125 Amps 4 pole ,25 KA and fixed on angle iron frame of required size and PCC 1:4:8 in plinth complete all as specified and directed by Engr-in-Charge.
VIKAS CONSTRUCTION CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .