Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.8 CrAdmitted-Finance | +15.50% | ₹12.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹13.0 CrAdmitted-Finance | +17.20% | ₹13.0 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical 12TH FLOOR A II 1202 CORPORATE PARK SECTOR 142 NOIDA GAUTAM BUDDH NAGAR GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 UDYAM DL 08 0001156 07AADCH3587R1ZT B 09AADCH3587R1ZP R MII STATUS AS VERIFIED | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | - | - | - | Rejected-Technical NOT RECOMMENDED |
Tender Value
₹11.1 Cr
EMD Value
₹23 L
Closing Date
11 Mar 2026, 5:00 pmClosed
General Manager (Commercial)
Bridge and Roof Co. (India) Ltd Kankaria Centre (4TH/5th Floor) 2/1 Russel Street Kolkata 700 071
AIRPORT AND IT SYSTEM WORKS IN CONNECTION WITH DEVELOPMENT OF KESHOD AIRPORT, KESHOD (GUJARAT)
2026_BandR_900331_1
B AND R/HO/51287/AIRPORT - IT SYSTEM/NIT/SC/01
Open Tender
Information Technology
180 days
KESHOD AIRPORT
PLEASE REFER TO TENDER DOCUMENT FOR DETAILS
10 documents required · 10 mandatory
₹30,680
Bridge and Roof Co.India Ltd
₹23 L
31 Mar 2026
25 Feb 2026
12 Mar 2026
25 Feb 2026
11 Mar 2026
25 Feb 2026
DEVELOPMENT OF KESHOD AIRPORT, KESHOD, GUJARAT ( AIRPORT AND IT SYSTEM )
Tender Description
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Please Enable Macros to View BoQ information
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R/HO/51287/AIRPORT - IT SYSTEM/NIT/SC/01 Dated 25.02.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Router (minimum throughput of 1 GBPS or more) in HA Mode. The Router should be modular in architecture with multi-core Processor. Router should have 2 nos. of 10/100/1000 Base T ports & 2 nos 1G/10G SFP based ports from day one. Router should have 1X RJ-45 OR 1 X USB console port. Should have all the features as per tender specifications.
Internet Firewall (minimum threat prevention throughput of 10 GBPS in HA Mode. The appliance based security platform should be capable of providing minimum threat prevention throughput of 10 GBPS on real world/ Ent Mix/App Mix traffic after enabling IPS, User ID, Anti Virus, logging and Application Visibility Security Services in a single appliance from day one. The appliance should have minimum 4 X 1G TX, 8X10 G SFP+ ports,OOB,Console, 2X HA and USB from day 1. The trans receiver has to be proposed as per solution. The appliance should have reduntant internal power supply and Fan. Should have all the features as per tender specifications.
Core Cum Distribution Switch in HA Mode. Switch should be with minimum 48 no. of 10 Gig SFP+ ports (as per requirement) and 4 nos. of 100 Gig QSFP ports from day 1. Switch should support for Active Active High availability or Virtual Chassis / Stacking. Switch should have hot swappable 1:1 redundant internal power supply.Switching system shall have minimum 32k MAC Addresses and 1K active VLANs.Switch should support minimum 1500 ACLs, minimum 4k Multicast routes,minimum 20k Unicast Routes for IPv4 and 10k Unicast Routes for IPv6. Switch should have minimum 16GB RAM, 16 GB flash & 32MB packet buffer. Should have all the features as per tender specifications.
Access Switch 48 Port PoE+ . Each proposed Switch should be 1 RU & must have 48 nos 10/100/1000 Base T ports and 4 nos. SFP+ uplinks ports available from day 1 with PoE+ capability and minimum 760W or better PoE Power .Switch should have slot/ports for stacking with stacking ports and cables and should provide 80 Gbps or better stacking solution.Switch should have minimum 1GB DRAM, minimum 2 GB internal / external flash & minimum 6MB packet buffer Shall have minimum 16K MAC Addresses and 512 active VLANs. Should have all the features as per tender specifications.
Access Switch 48 Port non PoE . Each proposed Switch should be 1RU & must have 48 ports with 10/100/1000 Base- T and 4 SFP+ uplinks ports available from day 1.Switch should be populated with 2 single mode 10G SFP+ Modules from day 1. Each proposed switch must support stacking for up top 8 switches and should provide 80 Gbps or better stacking solution. Switch should have minimum 1GB DRAM, minimum 2 GB flash & minimum 6MB packet buffer . Should have all the features as per tender specifications.
24 Port PoE Access Switch : Each proposed Switch should be 1RU & must have 24 nos. 10/100/1000 Base-T ports & 4 nos. SFP+ uplinks ports available from day 1. Switch should be with PoE+ capability and should have minimum 370W or above PoE Power .Switch should be populated with 2 single mode 10G SFP+ Modules from day 1. Each proposed switch must support stacking for up top 8 switches and should provide 80 Gbps or better stacking solution. Switch should have minimum 1GB DRAM, minimum 2 GB flash & minimum 6MB packet buffer . Should have all the features as per tender specifications.
24 Port NON PoE Access Switch: Each proposed Switch should be 1RU & must have 24 nos. 10/100/1000 Base-T ports and 2 SFP+ uplinks ports available from day 1 .Switch should have slot/ports for stacking with stacking ports and should provide 80 Gbps or better stacking solution. Switch should have minimum 1GB DRAM, minimum 2 GB internal / external flash & minimum 6MB packet buffer . Shall have minimum 16K MAC Addresses and 512 active VLANs.Should have all the features as per tender specifications.
8 Port POE Switch: Each proposed Switch should be 1RU & must have 8 nos. 10/100/1000 Base-T ports & 2 nos. SFP+ uplinks ports available from day 1. Should have all the features as per tender specifications.
WIRELESS LAN CONTROLLER / MANAGER in HA Mode: Solution must be compliant with IEEE CAPWAP/LWAPP/HTTPS/VxLAN/IPSEC/EoGRE or equivalent standard. Device should be scalable to minimum 250 AP in same hardware and minimum 5000 clients. Device must have atleast 2x 10G SFP+ and 2x1/2.5 G Copper interfaces. Must support coverage hole detection and correction that can be adjusted on a per WLAN basis.Controller should have rogue AP detection, classification and automatic containment feature.Must support 802.11e and WMM. Should have all the features as per tender specifications.
ACCESS POINT (INDOOR) Access Points proposed should have minimum 4x4 MIMO radios on both 2.4 GHz and 5 GHz antennas for transmission & receiving with minimum 3 GBPS or higher aggregate data rate. It should support MU-MIMO and OFDMA for increased and efficient connectivity from Day 1. Must support up to 21dbm of transmit power in both 2.4Ghz and 5Ghz radios.Must have minimum 16 SSIDs. Must be Wi Fi 6 Certified. Should have all the features as per tender specifications.
AAA Server. Proposed AAA solution should be an Appliance based solution.Proposed solution must support integration and security for both wired and wireless infrastructure. It should be ready to handle 500 concurrent User and Devices from day1 Profiling, Posture Assessment, Guest Access, MAB, Radius, TACACS+ and scalable for up to 5000 users and 5000 Devices. Devices are mixture of guest users, Organization staff, machine endpoints. AAA should support BYOD with Self-service authorization and device provisioning via open network.
Supply , Installation, Testing & Commissioning of 40G QSFP-LR - 10km MODULES Support 40 Gbps up to 10KM on SMF / up to 150 M on MMF.
10G SFP+ MODULES,Connector types LC,10G Base-LR / 10G Base-SR,Support 10 Gbps up to 10 KM on SMF / up to 300 M on MMF,Should be from same OEM of switches.
Supply , Installation, Testing & Commissioning of 1G SFP- LR Single Mode 10KM .
Stacking cable with Pair Module, Minimum 48 Gbps of stacking bandwidth with dedicated stacking ports and cables with minimum 8 switch in stack,Should be from same OEM of switches.
6/12 CORE Optical Fibre Cable (SM/MM): 6/12-core OFC, Unitube /Multi tube, 9/125µm, OS2 TYPE, Corrugated Steel tape Armoured (STA) , Polyethelene (HDPE Outer) , LSZH, ROHS Compliant, Telcordia GR-20, Performance warranty of 20 years or more. Should have all thge features as per tender specs.
12 Core Fibre LIU Loaded with pigtail: 12F for 12 Core, 1U LC Style, Loaded with SM Pigtail and Splice tray & Couplers & Splice Protectors.Metal/Alloy housing.Telcordia GR-20, Pigtail should comply G.657.A1 (Bend Insensitive), LSZH & RoHS Compliant. ANSI/TIA-568-C.3. Should have all thge features as per tender specs.
LC-LC SM Patch Cord: As per tender specs, site requirement and latest industry standards.
Cat 6A , U/UTP Cable Box -305 Mtrs, 4-pair, Cat 6A UTP Cable,LSZH, Channel performance up to 500 MHz or more, ETL 4 connector performance channel test report as per ISO/IE C 11801,23 AWG bare solid copper. Meets EIA/TIA 568-C.2/ANSI/TIA 568,2-D RoHS Compliant/EN50575 . Cable Skew: ≤45 nsec/100 meters Characteristic Impendence: 100±6 U@ 1¬500 MHz, D C Resistance Max: 9.5 Ohms/100m, IEC 60332-3/60332-1, IEC 61034- 2, IEC 60754-2, ISO/IEC 11801/EN 50173,Operational Temp: -20°C to 60°C.
Cat 6A UTP Information Outlet with Faceplate & Gang Box: Cat 6A UTP Jack P CB based Information Outlet (I/O) RJ45, TIA-568 C.2 / TIA-568 2.0.Contact Resistance: maximum 100milli ohms; Insulating resistance minimum 500 milli ohms; Current Rating : 1.5 A (max) .Meets and exceeds ISO/IEC 11801/EN50173 ,EIA/TIA 568-C.2/ TIA-568 2.D, ROHS compliant. Faceplate & Gang Box Should have all features as per tender specification.
Category 6A 24 Port Loaded Jack(Patch) Panel:Cat 6A U/UTP, 24-port loaded Modular, Loaded with 24 nos. UTP ports for PCB based IO Jacks, 1U size., ISO/IEC 11801/EN50173, EIA/TIA 568-C-2/ TIA-568 2.D, UL Listed, RoHS. Current Rating" 1.5A @20°C or 68°F.
Category 6A 48 Port Loaded Jack(Patch) Panel:Cat 6A U/UTP, 48-port loaded Modular, Loaded with 48 nos. UTP ports for PCB based IO Jacks, 1U size., ISO/IEC 11801/EN50173, EIA/TIA 568-C-2/ TIA-568 2.D, UL Listed, RoHS. Current Rating" 1.5A @20°C or 68°F.
Category 6A 8 Port Loaded Jack(Patch) Panel:Cat 6A U/UTP,8-port loaded Modular, Loaded with 8 nos. UTP ports for PCB based IO Jacks, 1U size., ISO/IEC 11801/EN50173, EIA/TIA 568-C-2/ TIA-568 2.D, UL Listed, RoHS. Current Rating" 1.5A @20°C or 68°F.
Category 6A UTP Patch cord 1 Meter: 3 Feet Cat 6A U/UTP Patch Cable, TIA- 568C/ TIA-568 2.D Category- 6A, UL-listed/ETL, RoHS.Solid copper.Plug Insertion Life Min. 750 times. LSZH, IEC 60332-3/ IEC 60332-3-22, IEC 60754-2/ IEC 60754, IEC 61034-2/ IEC 61034, ISO/IEC 11801/EN50173, Operational Temp: -20° to 60° Celsius.
Category 6A UTP Patch cord 2 Meter: 7 Feet Cat 6A U/UTP Patch Cable, TIA- 568C/ TIA-568 2.D Category- 6A, UL-listed/ETL, RoHS.Solid copper.Plug Insertion Life Min. 750 times. LSZH, IEC 60332-3/ IEC 60332-3-22, IEC 60754-2/ IEC 60754, IEC 61034-2/ IEC 61034, ISO/IEC 11801/EN50173, Operational Temp: -20° to 60° Celsius.
Category 6A UTP Patch cord 5 Meter: 5 meter Cat 6A U/UTP Patch Cable, TIA- 568C/ TIA-568 2.D Category- 6A, UL-listed/ETL, RoHS.Patch cords shall be of solid copper cable with UL/ETL Listed.Plug Insertion Life Min. 750 times. Patch cords sheath shall be LSZH as per IEC 60332-3/ IEC 60332-3-22, IEC 60754-2/ IEC 60754, IEC 61034-2/ IEC 61034, Operational Temp: -20° to 60° Celsius.
Wall Mount 9U/12U/15U Rack, Should be 9U/12U/15U Height Rack and have 19” mounting bracket in front & rear and wall mountable with side panels, Front Glass Door with lock. Depth:600 mm.Fans 90 CFM 230 VAC with 2 cooling fans on top.PDU Horizontal 5 Amp with 6 sockets,1U Wire Manager; Mounting Hardware.
Floor Mount Network 32U/42U Rack:Modularity and Scalability, conforms to DIN 41494, Load rating go 850 Kgs, Aluminium and CRCA construction , depth: min. 800mm. Door Steel 800W, 42 U, Perforated with Hex Perforation.Castor Ft Brake 100Kg.Fan housing Unit with 4 Fans 90CF M 230VAC.PDU 5x15AMP with 10 Socket, Earthing Kit. Loaded with Cable Manager and other accessories required for Network Rack.
Wall Mount 6U Outdoor /Weather proof Rack: Should be 9U Height Rack and have 19” mounting bracket with IP66 rating Depth: min. 600 mm, Weather proof,PDU Horizontal 5 Amp with 6 sockets, 1U Wire Manager; Mounting Hardware.
IP PTZ DAY/NIGHT COLOUR MEGA PIXEL ONVIF OUTDOOR CAMERA; Image Device: ~ 1/3” or better CCD/CMOS sensor,Focal length (For Outdoor Camera): ~ 4.3 mm to 129 mm or better, Optical zoom (For Outdoor Camera): 30 x or better,Number of Pixels: 1920 x 1080 ,Resolution: 1080p HD @25 FPS or better,Minimum Illumination : B/W: 0.1 Lux or better; Colour: 0.6 Lux or better,Pan Travel: 360° Continuous,Tilt Travel: 0 - 90° ,SD Card: 32 GB,Power supply (Outdoor): Power Supply should be of the same OEM of Camera as per OEM’s design, however generally AC 230 V @ 50Hz input,Housing (Outdoor): IP 66 rated, Built in Heater and Blower and shall be of same make as of camera. IK10 certified for vandal proof rating,. Mount: Surface/Ceiling/pipe/corner/parapet/ pendant with wall mount bracket/In Ceiling as required.The camera OEM housing and mount should be: Of the same make as that of camera and suitable for the model number offered as specified by the manufacturer and should be an integrated unit , CE certified/ UL listed/BIS . Should have all the features as mentioned in tender.
IP PTZ DAY/NIGHT COLOUR MEGA PIXEL ONVIF INDOOR CAMERA; Image Device: ~ 1/3” or better CCD/CMOS sensor ,Focal length (For Indoor Camera): ~ 4.7 mm to 94 mm or better,Optical zoom (For Indoor Camera): 20 x or better, Number of Pixels: 1920 x 1080 ,Resolution: 1080p HD @25 FPS or better ,Minimum Illumination : B/W: 0.1 Lux or better; Colour: 0.6 Lux or better ,Pan Travel: 360° Continuous ,Tilt Travel: 0 - 90°,,SD Card: 32 GB. Power supply (Indoor type): Shall have the ability to be powered by PoE+ 802.3 as well as DC/AC power adapter ,Housing (Indoor): IP 54, shall be of same make as of camera,The camera OEM housing and mount should be: Of the same make as that of camera and suitable for the model number offered as specified by the manufacturer and should be an integrated unit ; CE certified/ UL listed/BIS . Should have all the features as mentioned in tender.
IP DAY/NIGHT FIXED COLOUR MEGA PIXEL ONVIF BOX OUTDOOR CAMERA;Image Device: ~ 1/3” CMOS sensor;Lens:OEM varifocal lens, Auto iris, f ~ 10 mm to 40 mm (+/- 10% for Outdoor Camera) or better;Number of Pixels : 1920 X 1080;Resolution: 1080p HD @25 FPS or better;Minimum Illumination : B/W: 0.1 Lux or better; Colour: 0.6 Lux or better;Outdoor cameras: With IR sensor;Video Stream: Dual H.264 or Better video stream for independent viewing and recording;Wide Dynamic Range (WDR): 70 dB or better;SD Card: 32 GB;Power supply (Outdoor): Power Supply should be of the same OEM of Camera as per OEM’s design, however generally AC 230 V @ 50Hz input;Housing (Outdoor): IP 66 rated, Built in Heater and Blower and shall be of same make as of camera;Mount: Surface/Ceiling/pipe/corner/parapet/pendant with wall mount bracket/In Ceiling as required ,Of the same make as that of camera and suitable for the model number offered as specified by the manufacturer and should be an integrated unit ,CE certified/ UL listed/BIS;complete with all accessories. Should have all the features as mentioned in tender. CE certified/ UL listed/BIS . Should have all the features as mentioned in tender.
IP DAY/NIGHT FIXED COLOUR MEGA PIXEL ONVIF DOME CAMERA;Image Device: ~ 1/3” CMOS sensor;Lens : OEM Varifocal lens, Auto Iris, lens f ~ 3 mm to 9 mm (+/- 25% for Indoor Camera);Number of Pixels : 1920 X 1080; Resolution: 1080p HD @25 FPS or better; Minimum Illumination : B/W: 0.1 Lux or better; Colour: 0.6 Lux or better;Video Stream: Dual H.264 or Better video stream for independent viewing and recording ;Wide Dynamic Range (WDR): 70 dB or better ;SD Card: 32 GB;Power supply (Indoor type): Shall have the ability to be powered by PoE 802.3 as well as normal DC/AC power ;Housing (Indoor): IP 54, and shall be of same make as of camera;Mount: Surface/ Ceiling/ pipe/ corner/ parapet/ pendant with wall mount bracket/In Ceiling as required;The camera mount should be Of the same make as that of camera and suitablefor the model number offered as specified by the manufacturer and should be an integrated unit. CE certified/ UL listed/BIS;complete with all accessories. . Should have all the features as mentioned in tender. CE certified/ UL listed/BIS. Should have all the features as mentioned in tender.
Network Attached Storage (NAS) for Terminal & ATC (300TB HDD) : SAS/SATA Disk (In Raid 6 Configuration), suitable power socket, DC power converters, connectors, cables etc. Network Attached Storage (NAS) shall be supplied for the complete storage for all cameras for 24x7 in real time mode for a period of 30 days and additional 25% vacant space in NAS. NAS Storage System with RAID 6 configuration shall be used to record video streams based on the configuration assigned by administrator. A. Workstations & Servers within the LAN should be able to access the recorded video streams. The Storage device shall support simultaneous play back and recording at full duplex operation. Controller: Dual Active-Active Controllers in failover mode with no single point of failure Onboard Cache: 16 GB per Controller (Mirrored) .Storage Disk:i. 10K/ 7.2K rpm SAS/NL-SAS/SATA disk for 30 days .Host Interface: At least four Gigabit Ethernet (IP) ports and four FC ports.HDD type support: SAS, SSD, NL-SAS/ SATA .Inbuilt RAID Support : RAID-Double Disk failure support/ RAID-6. Network Transport Protocols: TCP/IP .Server/ Storage should support Protocol (As per solution): CIFS, NFS, iSCSI, FCP, HTTP/HTTPS, FTP, NTP, SNMP, SMTP, DHCP and DNS. Power Supply : Hot pluggable Redundant Power Supply. Scalability: The offered storage shall be scalable to add additional 50% usable capacity at site within the same storage .Data storage should be at a central location in the airport. Should have all the features as mentioned in tender.
Rack Mountable Camera server for both Terminal & ATC in N+1 configuration including operating system and anti virus complete with all accessories as per specification. Each server can accommodate up to 100 license . CPU: 64-bit high performance, Minimum Two Processor of 8 Core each or higher Intel/AMD CPU operating at 2.1 GHz or more with a minimum of 11 MB L3 cache or higher .Memory: 16 GB DDR RAM Upgradable to 64 GB, Hard Drives: SAS 10K rpm or higher hot swappable Hard Disk in RAID 5 or 6 configuration having usable space of 500 GB or more.Power supply : Redundant Power Supply.Network Adapter(NIC): Dual 10Gbps ports.Operating System: Licensed MS Windows Server or Linux (Latest version) . Should have all the features as mentioned in tender.
VMS License complete for both Terminal & ATC . VMS Software for Camera Server, NVR/NAS, Work-Station loaded in all the Servers to be provided with Camera licenses suitable for all ONVIF Cameras with full functionality, 3 concurrent client user licenses, Virtual Matrix capability, 100% Failover Recording, complete as per specifications with media (2 Nos. software CD/media at each site) and license as applicable.Should have all the features as mentioned in tender.
Supply of VMS -Camera connection license
Rack Mountable video analytic server with N+1 including operating system and anti virus.CPU: 64-bit high performance, Minimum Two Processor of 8 Core each or higher Intel/AMD CPU operating at 2.1 GHz or more with a minimum of 11 MB L3 cache or higher .Memory: 16 GB DDR RAM Upgradable to 64 GB, Hard Drives: SAS 10K rpm or higher hot swappable Hard Disk in RAID 5 or 6 configuration having usable space of 500 GB or more.Power supply : Redundant Power Supply.Network Adapter(NIC): Dual 10Gbps ports.Operating System: Licensed MS Windows Server or Linux (Latest version). Should have all the features as mentioned in tender.
Supply of Video Analytics Software License with required number of server as per specifications.
Supply of Video analytics license for Fixed Cameras for terminal building to meet tecnical & functional requirement as per tender specifications.
VMS Client/workstations :PC TYPE with viewing Licesense Minimum 7th Generation Core i7 Intel /AMD Processor or higher operating at 3 GHz or more with 8 MB Cache or higher , 16 GB DDR 3 or higher, 500 GB SATA/ SAS or more, 4 GB NVidia Ge Force DVI or better duaL port Graphics card .RAID: supported.Network Adapter(NIC): Two numbers of 10Gbps ports.Operating System: Licensed MS Windows or Linux (Latest version). Should have all the features as mentioned in tender.
55" Displays (for Client PC Type A) complete with wall/ceiling/floor mounting arrangement,Monitor Type: Industrial/ Professional suitable for 24x7 operation,Back Light: LED,Aspect Ratio: 16:9,Resolution: Full HD, 1920 X 1080 pixels or better,Brightness: 450 cd/m2 or better,Contrast Ratio (Native): 2400:1 without IPS/ 1100:1 along with IPS. Viewing angle: 178⁰.Video Input Ports: Digital Ports: HDMI/ DVI-D;/USB Port. Should have all the features as mentioned in tender.
3x2 (6 LEDS) 55" thin bezzel LED Video wall displays (For client PC Type B) .3 x 2 (6 LED Panels) Thin bezel Industrial Video Wall Displays with Video-wall Controller for Common Control Client Workstation complete with wall/ceiling/floor mount & mounting fixtures as per specifications. Video wall shall be Hardware/Software clustered displays with Client Workstation. 55" or more LED/LED backlit LCD Thin Bezel Monitor with mounting accessories for display of video images of all cameras in Common Control Room. Contrast Ration 2400:1 without IPS; 1100:1along-with IPS. Brightness 450 cd/m² or more. Resolution 1920X1080 or higher pixels. Viewing angle:178°.Thin Bezel design: Screen-to-screen distance between two neighboring displays shall not be more than 0.50 mm (left – right sides combine, top & bottom sides combine).
Supply of Speed Dome Controller Joystick, complete as per specifications & approved make
Supply, Installation, Testing and Commissioning of 4 PORT INDUSTRIAL GRADE SWITCH as per specifications.
GI Pole of SS304 having 4" dia, up to 5 Mtrs. height from ground level with accessories shall be supplied and installed for mounting of camera.The pole shall be grouted with SS base plate of min. size 300 mm x 300 mm x 6 mm under the ground embedded in concrete complete as per site requirement. The pole shall have weatherproof junction box where all the cables shall be terminated.The supply and installation of pole also covers civil and mechanical works including painting.
GI Pole of SS304 having 4" dia, up to 3 Mtrs. height from ground level with accessories shall be supplied and installed for mounting of camera.The pole shall be grouted with SS base plate of min. size 300 mm x 300 mm x 6 mm under the ground embedded in concrete complete as per site requirement. The pole shall have weatherproof junction box where all the cables shall be terminated.The supply and installation of pole also covers civil and mechanical works including painting.
IP PTZ DAY/NIGHT COLOUR MEGA PIXEL ONVIF OUTDOOR CAMERA FOR ISOLATION BAY WITH WI FI; 04 nos PTZ Cameras at Isolation Bay with feed to AHCR and SOCC rooms with WIRELESS configuration. Image Device: ~ 1/3” or better CCD/CMOS sensor,Optical zoom 40 x or better,Number of Pixels: 1920 x 1080 ,Resolution: 1080p HD @50 FPS or better, Minimum Illumination : B/W: 0.1 Lux or better; Colour: 0.6 Lux or better,Pan Travel: 360° Continuous,Tilt Travel: 0 - 90°, Auto Flip ,SD Card:Slot 1, up to 256 GB,Power supply (Outdoor): Power Supply should be of the same OEM of Camera OR OEM recommended,Housing: Minimum IP 66 & IK 10 rated, Built in Heater /Blower . Standard: CE certified/ UL listed/BIS. Protocols supported - IPv4, IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP,RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, FTP, SMTP, ICMP, IGMP, SNMPv1/ v2c/ v3(MIB-2), ARP, DNS, DDNS, QoS, PIM-SM, UPnP, Bonjour.Housing - Minimum IP66 & IK-10. Should have inbuilt heater / Blower, complete as per specification. Should have all the features as mentioned in tender. CE certified/ UL listed/BIS . Should have all the features as mentioned in tender.
Wireless link to connect the Cameras with SOCC: Supply, Installation, Testing and Commissioning of Unlicensed 6 GHz Wireless Radio Unit – C6x Lite Edition (LE) or equivalent, suitable for Point-to-Point (PTP) and Point-to-Multipoint (PTMP) applications. The radio shall operate in the 5150–6425 MHz frequency band with support for 20/40/80 MHz channel bandwidths, delivering up to 1.0 Gbps IP throughput in PTP mode and 750 Mbps IP throughput in PTMP mode. The unit shall support 2×2 MIMO, MU-MIMO, advanced OFDMA-based scheduling, adaptive modulation from BPSK to 1024-QAM, and maximum RF output power of 27 dBm. It shall feature an integrated radio with modular N5-X twist-on antennas (12–30 dBi) and native 8 dBi support. The device shall be IP67-rated, rugged outdoor-grade, with die-cast aluminum enclosure, operating temperature range of -40 °C to +55 °C, and passive 24 V PoE power input with maximum power consumption of 20 W. It shall support Gigabit Ethernet, secure management via HTTPS, SNMP, Syslog, Mimosa Cloud/MMP, AES security, VLAN and QoS features, and comply with FCC, CE, ETSI and RoHS standards.
1.5x1 mtr or higher True Colour LED Display Board ,Pixel Pitch:5mm, For 5mm pixel pitch it shall be 40000 dot/m2.Pixel Configuration: For 1.5X1 m2 Board: SMD LED with 3 IN 1 (RGB)LED make:Avago, Cree, Nischia, Osram [RoHS compliant and Lead (Pb) Free],Brightness:≥ 4000 cd/ m2.Contrast Ratio: 3000:1.Optimal viewing distance: 10 – 50 MTRS.Optimal Viewing Angle: 100° (H), 40° (V),Grey Scale/Colours: 256/16 Million Colours,Processing: 16 bit/color,Interface: TCP/IP LAN RJ45,Weather Protection: IP65 (Front),IP54 (Rear),Max. Power Consumption: ≤ 1000W/m2.Construction material: Stainless Steel Cabinet SS grade 304. Should have all the features as mentioned in tender & as per BCAS guidelines.
FIDS LED DISPLAY MONITORS 55" with Cabinet ,Back Light: LED,Aspect Ratio: 16:9,Resolution: Full HD or better.Brightness:700 cd/m2 or better.Contrast (Native) Ratio: 2400:1 without IPS; 1100:1 along with IPS.Viewing angle: (Horizontal/vertical): 176° or more.. Displays shall be CE, FCC certified, UL Listed. Intelligent Controller Processor: Intel/AMD 1.5 GHz or better, FSB 400 MHz,RAM: 2 GB or more,Flash Hard Disk: 32 GB or more,Keyboard and mouse connectivity,LAN/Network: Integrated 10/100/1000 Base T NIC with RJ 45 connector,Wi-Fi connectivity supporting 802.11 a/b g/n. Display Monitor shall be provided with cabinet suitable for industrial / professional 24 X7 use with arrangement for wall & ceiling mount installation with provision for Swivel movement. Should have all the features as mentioned in tender & as per BCAS guidelines.
FIDS LED DISPLAY MONITORS 42" with Cabinet ,Back Light: LED,Aspect Ratio: 16:9,Resolution: Full HD or better.Brightness:450 cd/m2 or better.Contrast (Native) Ratio: 2400:1 without IPS; 1100:1 along with IPS.Viewing angle: (Horizontal/vertical): 176° or more.Display Monitor for outdoor side installation no external cabinet to be installed over composite monitor. It shall be OEM Cabinet and inherent part of Monitor & protect from dust, sunlight, etc. Displays shall be CE, FCC certified, UL Listed. Intelligent Controller Processor: Intel/AMD 1.5 GHz or better, FSB 400 MHz,RAM: 2 GB or more,Flash Hard Disk: 32 GB or more,Keyboard and mouse connectivity,LAN/Network: Integrated 10/100/1000 Base T NIC with RJ 45 connector,Wi-Fi connectivity supporting 802.11 a/b g/n Display Monitor shall be provided with cabinet suitable for industrial/ professional 24 X7 use with arrangement for wall & ceiling mount installation with provision for Swivel movement.Should have all the features as mentioned in tender & as per BCAS guidelines.
FID System shall be provided with configured to operate in Automatic Failover configuration without any need of any manual intervention. During change over there shall be no loss of database transaction.System shall allow manual & automatic change over from main server to the standby server and vice versa.System shall have facility to recover inconsistent system/FIDS database from the other healthy & active server.FIDS shall be provided with client-server architecture with latest version of UNIX or LINUX or Microsoft Window Server as operating system of Server/Cluster server, and Windows or Linux as operating system of client terminals. TECHNICAL SPECIFICATIONS of Server, CPU: 64-bit high performance, 6/8 Core Intel/AMD CPU operating at 2 GHz or more with 12 MB Cache or more.Memory: 8 GB of DDR RAM or more/better expandable up to 32 GB,Chassis: Rack Mount type,SAS 10K/SATA 7200 rpm hot-swappable Hard Disk in RAID 5 or better configuration having usable space of 320 GB or more.Hot Swappable redundant power supply.NIC - Dual Integrated 10/100/1000 Mbps ports.OS: UNIX/LINUX/Microsoft Windows Server licensed (Latest version).Licensed Antivirus with update subscription valid till warranty and AMC period. Should have all the features as mentioned in tender & as per BCAS guidelines.
FIDS Application software & RDBMS shall be installed on FIDS Server. FIDS shall be scalable and expandable pre-wired (hardware & software) to add standard client PC/Laptop .FIDS Application software & RDBMS shall be supplied with all the required licenses.FIDS Application Software & RDBMS should have all the features as mentioned in tender & as per BCAS guidelines.
Automatic Flight Announcement System (AFAS) – To provide & integration with Airport Public Address System for Zonal Announcements of information, through Automatic Flight Announcement Software module and necessary hardware interfaces.This software module shall scan the flight information database for valid announcements, construct announcements, convert announcement text into voice format/audio signals and send to the appropriate zone of the PA system for announcing. It shall translate the flight information in to voice format for automatic announcement on the existing PA system of the Airport.To construct voice for announcement, the system shall have the following technology.Text-to-speech engine to automatically synthesize flight information into a voice for announcement. The text to speech engine shall have:The voice broadcast shall provision for male and female voice;The System shall be built around proven technology such as IVR technology.Multilingual announcement shall be possible i.e. Hindi, English and one of the Indian Language as per the requirement of the airport. Should have all the features as mentioned in tender & as per BCAS guidelines. Interactive Voice Response System (IVRS), if required – To cater to Automatic Flight Status enquiries through Telephone (PSTN) and Mobile Phones.
CLIENT TERMINAL ,Client Terminals shall be used to access FIDS Application Software User Interface for viewing and updating the Flight Information Database,CPU: Intel i7/AMD or better CPU operating at 2.4 GHz or more with 8MB Cache or more,RAM: 8GB or more,Motherboard Chipset: OEM Motherboard,SAS/SATA 7200 rpm Hard Disk having usable space of 500 GB or more,NIC – Gigabit Ethernet port,At least 2 x PCI express I/O slots,USB 2.0 or higher port: At least 4 USB ports (2 in the front).DVD RW Drive,USB optical Mouse with scroll and Keyboard,23”/21” LCD/LED or better monitor,OS: UNIX/LINUX/Windows Licensed, latest version,Licensed Antivirus valid for client version for Warranty & AMC Period. Should have all the features as mentioned in tender & as per BCAS guidelines.
NETWORK TIME PROTOCOL (NTP) SERVER, GPS/GLONASS satellite supported L1/L2/L5 Frequency band, Rack Mount Type, NTP SERVER to maintain and display IP based NTP time across the network containing L2/L3 switches shall be supplied by the bidder. NTP server shall act as a master clock with accuracy better than 50 ms in the network to which other clients shall interconnect over the network using NTP client software on Windows or Linux OS and synchronize periodically. It shall provide diagnostic and status ports/ indications for automatic/ manual intervention.The GPS NTP Server shall be equipped with two independent network interfaces (10/100/1000 Mbps Ports).NTP Server shall support all the required networking protocols. Should have all the features as mentioned in tender & as per BCAS guidelines.
FID Control Kiosk for Departure / Arrival/ Security Hall. Kiosk shall have provision to accommodate upto one 21” to 23" touch screen, one metallic keyboard with track pad, Kiosk shall have sufficient space to accommodate the CPU, UPS & PDU (power distribution unit for powering all equipment with two spare 6A Power ports) and shall be accessible through rear door. The entire design shall be modular; consisting of interchangeable and replaceable parts. Touch / Non touch screen shall have separate door for the accessibility/maintenance and all locks shall feature 2-point locking arrangement. Design shall be extremely rugged to ensure a minimum life of 10 years for structural stability, moving and non-moving parts.Should have all the features as mentioned in tender & as per BCAS guidelines.
Supply , Installation, Testing & Commissioning of SS Pole for Mounting of displays. The pole diameter shall be of approx 04 inches dual pole as per specification & list of make
IPABX server as per specification & list of approved makes
IP phone complete as per specification & list of approved makes
Analog Telephone complete as per specification & list of approved makes
Digital Phone as per specification
MDF / IDF boxes
Cabling for Analog phones
TCP / IP PA CONTROLLER with redundancy (1Main +1Redundant). The system controller shall dynamically assign network audio channels for audio routing between system devices across multiple subnets.The system controller shall be certified for EN 54-16/ ISO 7240-16, marked for CE and be compliant with the RoHS directive.It shall support >100 simultaneous High-Definition audio channels (24-bit, 48 kHz) for music routing and making calls, with encryption and authentication to protect against eavesdropping and hacking. It shall be capable of receiving Dante/Omneo/OCA/Ravenna enabled and AES67 audio streams.The System controller shall provide an interface for control date and multi channel digital audio over OMNEO using an integrated 5 port ethernet switch for redundant network connections, supporting RSTP and loop through cabling. The System controller shall have dual power supply inputs and power supplies. Should have all the features as per specifications.
TCP / IP Class D Multichannel Power Amplifiers (Min 250watt, Max 500watt or more) with DSP with automatic single / multichannel channel backup switching. The 4 or more -channel amplifier shall be DSP enabled Class D and fully and natively IP networked based, not requiring external converters capable of receiving Dante/ Omneo/ OCA/Ravenna/ or equivalent enable and AES67 audio streams.All amplifier channels support two independent loudspeaker groups, A & B, enabling redundant loudspeaker wiring topologies. The output power of each amplifier channel adapts to the connected loudspeaker load, only limited by the total power budget of the whole amplifier.This flexibility and the integration of a spare amplifier channel, makes it possible to utilize the available power effectively and use less amplifiers for the same loudspeaker load, compared to using traditional amplifiers. Should have all the features as per specifications.
6W ceiling mount IS/EN 54-24 certified speaker having the following specification: Type: Flush mount metal Ceiling Speaker. Rated Power: 6Watts, Power Tapping: 6/3/1.5W frequency range : 190 Hz to 18KHz or better Sound pressure level (SPL) : 98 dB @6W (1Khz at 1 m) or better Opening Angle 1 KHz / 4 KHz (-6 dB): 150/50 or better. Should have all the features as mentioned in tender & as per BCAS guidelines.
Active Line Array speaker : Active line array with built in DSP, DSP 32bit floating point, 900 Mflops ADC/ DAC 24bits S-D, 128 x oversampling ADC-DAC, network interface, with software configurable vertical coverage, with ambience noise sensing microphone, thermal overload protection, with RJ-45, ethernet 100 Mbps interface, 24bit word length. a. Type : Active line array b. Sampling Rate : 48 kHz c. Maximum throw: 20m,30m & 50m depending on the length of the array. d. Dynamic range > 105dB e. Sound pressure level (SPL) : 90 dB SPL or better. Should have all the features as mentioned in tender & as per BCAS guidelines.
60W Passive line array speaker Maximum Power - 90/100Watt Power Tapping: 60/30/15W Sound pressure level (SPL) : 108dB or better, 110@60 W (1 kHz at 1 m), Rated impedance 167 ohm Effective frequency range (-10 dB)- 190 Hz - 18 kHz Opening angle 1 kHz / 4 kHz (-6 dB) :horizontal 210° / 132° vertical 50° / 20°. Should have all the features as mentioned in tender & as per BCAS guidelines.
6W Wall Mount Speaker: Type: wall mount metal grille speaker Rated Power: 6W, Power Tapping: 6/3/1.5/0.75W frequency range : 300 Hz to 15KHz or better Sound pressure level (SPL) : 98-102dB@6 W (1 kHz at 1 m)or better Opening Angle 1 kHz / 4 kHz (-6 dB): horizontal 140° or better, vertical 140° or better. Should have all the features as mentioned in tender & as per BCAS guidelines.
NOISE SENSING MICROPHONES . These noise sensing microphones shall be Omni directional microphones with a support construction including mounting rod and junction box suitable for mounting on the flush/ceiling/wall to the approval of architect.Should have all the features as per specifications.
CONTROLLER FOR NOISE SENSING MICROPHONES.
10W HORN LOUDSPEAKER WITH IP 65 PROTECTION: Horn Loudspeaker with excellent speech reproduction and sound distribution, IP 65 protection.Speaker shall comply emergency fire evacuation system as per IS/ BS code.Should have all the features as mentioned in tender & as per BCAS guidelines.
LOUDSPEAKER CABLES: Speaker Cable (without conduit ) :2 C x 2.5 sq.mm fire survival armoured cable (600/1000V) with class-2 Copper conductor having halogen free ceramified silicon insulation as per BS EN 50363 and low smoke zero halogen (LSZH) inner & outer sheath. Should comply with EN 61034-2 & EN 60754-1. The cable should meet fire performance circuit integrity test as per BS EN 50200:PH-120& BS 6387 CWZ. Cable shall be Fire Survival with 2 hour rated, LPCB/TUV Certified OR Speaker Cable (in conduit ) 2 C x 2.5 sq.mm fire survival cable (600/1000V) with class-2 Copper conductor having halogen free ceramified silicon insulation as per BS EN 50363 and low smoke zero halogen (LSZH) inner & outer sheath. Should comply with EN 61034-2 & EN 60754-1. The cable should meet fire performance circuit integrity test as per BS EN 50200:PH-120& BS 6387 CWZ..Cable shall be Fire Survival with 2 hour rated, LPCB/TUV Certified .
Microphone Cable (in conduit ):Supply, Installation, Testing and Commissioning of 3Cx1.5 Sqmm Fire Survival Circuit integrity UnArmoured screened Cable of 300/500V rated, Cable shall be Fire Survival with 2 hour rated, LPCB/TUV Certified as per tender specs.
CONTROL PC(WORKSTATION ): Control Software along with PC(workstation) of minimum configuration used to control, program and Monitor the complete Digital Public Address System.: CPU: Intel Core i7 or better ,8 GB RAM or higher, 500 GB SATA HDD or higher, , Network Interface Card- Dual integrated 10/100/1000 MBPS ports, Sound card & Speakers, Including all licenses of Windows, antivirus etc. valid till warranty & AICMC period.
AMPLIFIER RACK (42U, 19") : . All the control equipment and the power amplifiers shall be mounted in these standard 19" racks. The racks shall be located not less than 750 mm clear from the wall of the equipment room and shall have Cooling Fan, Mains panel On/OFF with required MCB and interconnectivity. If two or more racks are required, the racks shall be mounted side by side and bolted together.
Supply, Installation, Testing and Commissioning of Volume Controller.Should have all the features as mentioned in tender & as per BCAS guidelines.
Supply , Installation, Testing & Commissioning of 6 Mtrs. GI Pole (Class B) of 65 mm dia for mounting of Car call Horn speakers including all accessories as per specifications.
Supply , Installation, Testing & Commissioning of Floor stand SS mounts for Installation of beam stearing programmable speakers as per specification & list of make
FIRE ALARM CONTROL PANEL
Supply, Installation, Testing and Commissioning Of 2 loop Fire Alarm Control Panel shall be Modular Microprocessor IP based expandable fully intelligent Addressable Control Unit which shall control all intelligent addressable detectors, manual call stations Control / Monitor module etc. connected to it.The Fire Alarm Panel itself shall have all loop cards in it. No isolated mother board or transponder is allowed. Each loop shall be able to access a minimum of 120 addressable detectors / devices in any combination per loop,Short circuiting, loose wiring or missing units shall also be reported at the panel with pin point or segment-wise location. In such cases, the system through the use of Fault Isolators shall be able to isolate that segment between the two Fault Isolators,The panel shall have a liquid crystal display (LCD) type on it to indicate immediately all conditions. In case of testing of the system from the panel, the display shall be able to give readouts of intelligent value of all detectors being tested. The panel shall also be able to carry out continuous self monitoring when in normal condition,Number of detectors / devices per loop should not be exceeding 90 percent of the full capacity of each loop as per IS code.The panel shall have either an in-built or external printer coupled to the panel which shall log all events with time. The printer shall be suitable for printing panel’s event logs or as per the configuration to print automatically any of the events such as Fire, Fault, Alarm or Test, the unit address, time along with option for printing the Inputs, Outputs, Disablements, Network Faults etc. The system shall meet the BS/NFPA 71 & 72 standards and shall be listed with UL/EN ( latest versions).Should have all the features as per tender specifications.
Supply, Installation, Testing and Commissioning of Multicreteria detector . The detector shall have both optical and thermal sensor and shall be capable of working in combined mode (Optical + Thermal) or heat mode (only Thermal) or smoke mode with inbuilt fault isolator / isolator module (as per UL).b) The combined modes of operation both the inputs from the optical and thermal sensors are processed using special algorithms before an alarm decision are made. If thepresence of smoke is detected above a threshold value for a period of time or if heat sensor temperatures rise above certain fixed temp or rate of rise, then an alarm condition will be generated. In “heat only” mode only temperature above certain fixed level will generate an alarm conditions.The Base of the detector shall be interchangeable with other detectors and the construction shall be of polycarbonate or any approved flame-retardant material.The enclosure shall at least meet IP 54 protection grade ,It shall be able to withstand temperature variations from 0 degree Centigrade to 50 degree Centigrade. Relative humidity (non-condensing type) upto 93% shall not hamer its performance. The voltage rating shall be from as per OEM, though the voltage may be changed depending upon the working voltages of a proprietary Fire Alarm Panel.
Supply, Installation, Testing and Commissioning Of Manual Call Station shall be of Pull / Push down Resettable type units, completely encased in a cast aluminium housing or in 16-gauge MS / LEXAN / Polycarbonate, with provision for cable or conduit coupling. The Manual call station shall have the word prescribed in clear bold letters on facia window “In Case of Fire / Push In / Pull Down” as per OEM. Its casing shall be of red color: The Manual Call Box Station shall be fully addressable with its own set code and operated by digitized signals sent from the Panel. The Voltage range shall be as per OEM. It shall have protection as per IP 54 for indoors & IP 65 enclosure for outdoor applications. The operating temperature range shall be from 0-degree C to 50-degree C. Relative Humidity (non-condensing) range for performance parameters shall be between 0 to 93%.
Supply, Installation, Testing and Commissioning of The wall mounted Hooters cum Strobe and with inbuilt fault isolator / isolator module (as per UL), shall be suitable for indoor and outdoor application with adjustable sound level of 90 db to 120 db at 1M distance. Strobe shall be of red colour. It shall flash at 1Hz over the strobe’s entire operating voltage. The Hooters cum Strobe shall be addressable and loop powered. The hooter shall be with IP 54 protection category.
Supply, Installation, Testing and Commissioning Of The Network Repeater Panel shall be provided to display all system intelligent points (Devices). It shall be capable of displaying all information for all points (devices) on the network. Network repeater panel shall have with minimum 320-character LCD display (minimum) / touch screen colored display / HMI Display with touch sensor. It shall be possible to silence alarms, evacuate and reset.
Supply, Installation, Testing and Commissioning of The Input Device shall provide an addressable input for N.O. or N.C. contact devices such as manual water flow switches, pressure switches, etc. The input device shall provide a supervised initiating circuit. An open-circuit fault shall be annunciated at the Fire Alarm panel (Subsequent alarm shall be reported.) The device shall contain an LED which blinks upon being scanned by the Fire Alarm panel. Upon determination of an alarm condition, the LED shall be latched on. The module should be minimum IP 40 protection category when housed in a case or as per manufacturer design.
Supply, Installation, Testing and Commissioning Of The control module shall provide an addressable output for a separately powered alarm indicating circuit or for a control relay. The control module shall provide a supervised indicating circuit where indicated on the plans. An open circuit fault shall be annunciated at the Fire Alarm panel. The Output Device shall provide a control relay where indicated on the plans. The relay contacts shall be SPDT rated at one amps/ as per OEM, 24V DC. The device module shall contain an LED which blinks upon being scanned by the Fire Alarm panel. Upon activation of the device, the LED shall be latched on. The module should be minimum IP 40 protection category when housed in a case or as per manufacturer design.
Supply, Installation, Testing and Commissioning of Response indicator a. The response indicator shall be used to locate a fire alarm if the detector's LED cannot be seen (i.e. it is hidden by false floors, false ceilings etc.). When a detector is set off, as well as the alarm message being sent, unit response indicator is also activated and flashes red. b. Response indicator shall loop powered. Separate power supply shall not be required for response indicator. c. Remote response indicator shall be installed outside the areas normally kept closed to identify the detector response even if the room is locked. These indicators shall be able to indicate the status of the corresponding detectors in these areas.
Supply, Installation, Testing and Commissioning of Addressable Heat Detector as per tender specifications.
Supply, Installation, Testing and Commissioning of Addressable Duct Smoke Detector as per tender & BCAS specifications.
Supply, Installation, Testing and Commissioning of Addressable Motorised Auto Align Beam Detector as per tender specifications.
Supply, Installation, Testing and Commissioning of Addressable Relay Module as per tender specifications.
Supply, Installation, Testing and Commissioning of 2x1.5 sq. mm Fire Survival Armoured Copper conductor XLPE insulated cables./ FRLSH wire in MS conduit wherever required.
Supply, Installation, Testing and Commissioning of Telephone Jack as per tender specifications
Supply, Installation, Testing and Commissioning of Telephone Handset as per tender specifications
Standalone system (one client):
A full installation on one single computer machine is required. The hardware and software environment must fulfill the following definition:
Supply, installation, testing and commissioning of Workstation Tower with following Specs: Type: Workstation Tower, Processor: Intel Core i7 or higher, Memory: 16GB, Harddisk: 1 TB (for example Western Digital Green/Red) 2, Network card: Gigabit speed, Graphic Card: Onboard graphics adapter (for example Intel 4600HD), or Mid range graphics card (for example GeForce GT 730, AMD Radeon, Radeon R7 250), Graphic Card: Onboard graphics adapter (for example Intel 4600HD), or Mid-range graphics card (for example GeForce GT 730, AMD Radeon, Radeon R7 250). Recommended software environment: Windows 10 Professional (64 bit) or higher Windows Server 2012 R2 or 2016 or higher, Microsoft SQL Server 2012, SQL Server 2014, SQL Server 2016 (Express, Standard or Enterprise) or higher. Anti-virus software- shall be provided (and suitably renewed during DLP and AICMC period).
Server system (up to 10 clients) :
One client/server system for mid-sized sites with a high data transfer rate is required. The hardware and software environment must fulfill the following definitions:
Supply, installation, testing and commissioning of Workstation Tower with following Specs: Type: Server tower, Processor: Core i7 4th generation (for example Intel Core i7-4770K), Intel Xeon (for example Intel Xeon E5-1630 v3, Intel Xeon E5 1620 v2) or higher, Memory: 32GB, Hard Disc: 2 * 1 TB hard disk (for example Western Digital Red, Seagate Constellation ES.3), Network card: Gigabit speed, Onboard graphics adapter (for example Intel 4600HD), or Mid range graphics card (for example GeForce GT 730, AMD Radeon, Radeon R7 250), Recommended software environment: Windows 10 Enterprise, multilingual, 64 bit or Windows Server 2016, multilingual, 64 bit or higher, Microsoft SQL Server 2012, SQL Server 2014 or SQL Server 2016 (Standard or Enterprise) or higher, Anti-virus software- shall be provided (and suitably renewed during DLP and AICMC period). Network requirements: Local network, 1000 Mbps up/down, Latency less than 10 ms. Main Server shall be provided with redundancy
Colour Monitor 21": To display high resolution 3D graphics, all operator workstations shall have colour monitors with Full HD screens.
Colour Printers A4 : To prevent mixing of alarms with report printouts, there shall be two types of printers: Alarm printer & Report printer. If an alarm printer is off-line, alarm messages shall automatically be rated to the report printer to ensure that alarm messages are reported.
Laser Printers A3: To prevent mixing of alarms with report printouts, there shall be two types of printers: Alarm printer & Report printer. If an alarm printer is off-line, alarm messages shall automatically be rated to the report printer to ensure that alarm messages are reported.
Supply, installation, testing and commissioning of System Graphics. The operator interface software shall be graphically based and shall include features as Plant overview, User privileges, Graphics, Operating messages, Full graphics mode, Graphics generation, Navigation, Continuous update and display, Energy management, Scheduler programs, Multiple user system, Access protection, Alarm handling, Alarm generation, Acknowledgment, Alarm display, Event management, Report generation, Remote operation Via web browser, Trend data etc. Latest software from the same OEM supplier. Minimum 5 user license of the software with lifetime license shall be provided. Monitoring facilities including work stations shall be provided at five locations.
Supply, installation, testing and commissioning of DDC Controllers. The control system shall consist of a high-speed, peer-to-peer network of DDC controllers I.P. network controller (as desired) and a web-based operator interface. Each DDC Controller shall be equipped with a battery-free real-time clock. The system shall employ a modular I/O design to allow easy expansion. Input and output capacity is to be provided through plug-in modules of various types. Controller with more than 2 IO module or total IO count more than 40 on one controller with modules shall not be acceptable. Adding more IO points on one controller shall impede the distributed architecture purpose and increase the operational complexities in case of controller failure. Required number of DDC controllers shall be provided as per I/O summary and requirement (with keeping 15% extra in each DDC controller). All the controllers shall be housed in Lockable Vandal proof boxes which shall either be floor mounted or wall mounted. These shall be free standing, totally enclosed, dust and vermin proof and suitable for tropical climatic conditions. The panel shall be metal enclosed 18 SWG CRCA sheet steel cubicle with gaskets between all adjacent units and beneath all covers to render the joints dust proof. All panel enclosures used in plant room spaces and external to building shall be suitable for outdoor application (IP 54 protection).
Portable Operator Terminal (POT). POT shall be provided to allow operator readout of system variables, override control and adjustment of control parameters. The POT shall be portable and plug directly into individual controllers for power and data.
Supply, installation, Testing & Commissioning of System Integration unit consisting of microprocessor based controller units BTL & UL Listed for third party integration, for the following units: The 3rd party Integration unit shall provide the interface between Ethernet LAN and the 3rd party field control devices such as DDC or PLC or any other devices which need to be integrated. These shall also provide supervisory capability of functions over the devices connected to it. A interface is required to connect various third-party devices that supports communication protocols such as Modbus.
Supply, installation, Testing & Commissioning of following Field devices and sensors :
PVC 25 mm conduits of required dia shall be used
Communication Cable: 2 Core x 1.5 sqmm multi strand shielded twisted pair, Annealed tinned copper cable (Overall beld foil Aluminium polyester shield)
Signal Cable: 2 Core x 1.0 sqmm sqmm multi stranded, shielded, Annealed tinned copper cable
Cat6A cable : DDC communication over IP via IT networking Cat6A cable
BOOM BARRIER
Supply, Installation, Testing and Commissioning Motorised Vehicle Barrier integrated with Smart I/O Box to integrate with Tyre killer, Bollard and UVSS seemless integrated complete with Control Unit and integrated Two channel Loop Detector and Boom length up to of 3.5 Meters- 5 Meters length with 2 to 3 Sec Opening/ Closing time. IP Rating: 65,Housing: Barrier Housing Unit: Powder Coated Boom: Powder Coated White RAL 9010 with Red reflective strips. Housing Dimension : Modular Boom Specifications: The Booms shall be extruded aluminium with Rectangular or Round or octagonal shape having fixed / Telescopic arm feature to adjust the boom. Digital Inputs: Minimum 8, Digital Outputs: Minimum 4, Relay Output- at least 4. Opening & Closing Time: Upto 2-3 seconds for Boom Length up to 3.5 Meters-5 Meters Should have all the features as per tender specifications.
TYRE KILLER/ SPIKE SYSTEM
Spike System 4.5m length, Independent Drive, Flush Mount - Kit includes: Independent Flush Mount Drive Mechanism, Controller, 3 x 1.5m Flush Mount Spike Modules, excludes 7Ah battery, 2A SM charger & packaging - This is a spike kit for a 4.5 metre roadway. It incorporates an independent drive with dedicated controller. The drive is typically mounted underneath the traffic with the controller locating on a dedicated bracket inside the casing of the barrier.These spikes are designed for flush mounting. Should have all the features as per tender/BCAS guidelines.
Supply , Installation, Testing & Commissioning of ANPR Camera integrated with boom barrier with ANPR software & all the required license & as per tender & BCAS Specifications
Supply , Installation, Testing & Commissioning of Driver Image Box Camera with lens and housing & with software & integrated with Boom Barrier system through smart I/O Box. Specification of camera to be followed from technical & BCAS specifications complete with all accessories as required as per actual site condition.
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Drawings_part_02.rar
Additional Documents • 35.27 MB
Drawings_part_01.rar
Additional Documents • 17.24 MB
Safety_DLP_Env_Laws_GRIHA_Design_report.rar
Additional Documents • 25.95 MB
Tech_spec_Makelist_QA_Tests.rar
Additional Documents • 27.11 MB
eNIT_CS_Airport_IT_AAI_Keshod_R0.pdf
Tender Documents • 1.44 MB
BOQ_946330.xls
BOQ • 0.67 MB
Download all tender documents and submit your bid