Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹51.8 L+₹1.8 L (3.70%)Rejected-AOC | L2 | Rejected-AOC R |
Tender Value
₹47.9 L
EMD Value
₹95,800
Closing Date
25 Dec 2023, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
PROVN OF CERTAIN SPECIAL REPAIR WORKS AT IMA DEHRADUN
2023_MES_625150_2
GE/IMA/T-57 of 2023-2024 9360/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹95,800
Yes
31 Jan 2024
28 Nov 2023
27 Dec 2023
29 Nov 2023
25 Dec 2023
5 Dec 2023
Amount
Dismantling AC corrugated, semicorrugated sheet including ridge in roof covering, complete all as specified.
S&F pre-painted galvalume aluminium zinc coating GI based Plain steeel sheet 0.50mm thick an colour having tensile strength of 550 Mpa and 150 GSM as in roof covering/cladding to wall fixed with self tapping screws complete all as specified. Make:- Tata Blue Scope/ JSW Coloron+/ Charminar
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steeel sheet 0.50mm thick an colour having tensile strength of 550 Mpa and 150 GSM as in roof covering/cladding to wall fixed with self tapping screws all as specified. Make:- Tata Blue Scope/ JSW steel Coloron+/ Charminar
M & L for Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with 0.80 mm thick class VIII complete all as specified.
S&F of Structural steel, rolled section as in main and cross beams, hips and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe-410 W (Gde-E-250)all as specified and directed by Engineer-in-Charge. Make:- Tata/ JSW steel/ Jindal Steel
Preparation old steel surfaces exc. 10 Cm width or girth and applying One coat of synthetic enemelled paint including all preparation complete all as specified and directed.
Preparation new steel surfaces exc. 10 Cm width or girth and applying two coats of synthetic enemelled paint over one coat red oxide primer complete all as specified and directed.
Taking down cement plaster on brick or stone walling built in cement mortar including raking out joints hacking for key scrubbing down with water etc including removal outside the IMA premises complete as specified.
M&L for 15 mm thick ready mix (internal/external/ceiling) plaster on brick or concrete surfaces including providing & mixing water proofing compound as per manufacturers specification, surface finished even & fair complete all as specified and directed Make : ACC (Suraksha) /Ultratech(Readyplast)/Birla (Aerocom)/ unicrete.
M & L for two coats of cement based paint on newly plastered surface over a coat of chalk whiting including all preparation complete all as spd and directed.
M & L for preparation of old decorated surfaces (plastered/ un-plastered) of walls including removing all vegetation etc and applying one coat cement based paint on walls complete all as specified and directed.
Supply and Instalation Split Air Conditioner comprising following specifications: a) BEE star rating : 4 star b) PM 2.5 filter c) Hot and Cold type d) Energy saving with human sensor e) Double swing automatic 3D Airflow f) Silicon coated PCB for long life g) High Voltage Protection upto 700V h) 5 speed fan control i) Self Diagnosis j) 10 year warranty on inverter and compressor and 5 year warranty on inverter PCB. k) 3 metre piping and insulation kit l) Anti corrosion copper Heat Exchanger m) Tonnage : 2 TR n) Rated ISEER : Min 4.4 o) Moisture Removal : Min 2.5 Litre/ hour p) Ambient Operating Temperature range : Cooling (18 degree celcius to 55 degree celcius) Heating ( -15 degree celcius to 24 degree celcius) q) Refrigerant type: Non CFC R32 r) Compressor type : Advanced Hyper Tropical Twin Rotary type s) Evaporator and Condenser Coil Material type : Copper t) Make : Voltas/ LG/ Lloyd
Supply and Fix water cooler with normal cooling capacity 40 ltrs per hrs and storage capacity of 80 Litres. The key features of Water Coolers should be as follows : i) Gross Volume : 80 L ii) Product colour : Steel Grey iii) No. of faucets : 02 iv) Tank Capacity : 80 L v) Body type : SS vi) Energy Efficient Compressor vii) Tropicalized Machine viii) Eco friendly Refrigerant ix) Min 40 % Electricity Savings x) Safety Compliant xi) IN SITU PUH Insulation xii) Longer cooling retention xiii) Compact Design xiv) Anti corrosive Precoated Body xv) Soft Aesthetic Design Make : Voltas / Samsung / Bluestar
Supply & Fix Refrigerator comprising following specifications: a) BEE Star ratings : Min 4 star b) Premium refrigerators with auto-defrost function. c) Capacity : 580 litres d) Manufacturer warranty : 1 year on product, 20 years on compressor e) Digital Inverter Compressor : Automatic Adjustment Of Speed In Response To Cooling Demand, Quieter Operation And Uses Less Power. Digital Inverter Compressor : greater energy efficiency, less noise and a long-lasting performance. Consumes 50% less power, backed up by 20 year warranty f) Interior Description : Fresh Food Capacity : Min 381L | Freezer Capacity : Min 199L | Total No Of Compartments : 2 | Drawers : 2 EA | Shelves : 3 EA | Shelf Type : Toughened Glass Shelves | Anti-Bacterial Gasket | Bottle Storage Capacity : 6 Water & Ice Dispenser : Non Plumbing water and ice dispenser for cold water. g) Additional Features : Twin Cooling Plus | Powercool | Powerfreeze | Built in Design | Easy Access Control| Precise Cooling | Fingerprint Resistant Included in the box : 1 Refrigerator unit, User Manual, Warranty Card, Ice Tray, Egg Tray , etc. Make : Voltas/ LG/ Samsung
S & F sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with and including one single pole MCB 20 Amps. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs and taking down old unsv Sheet Metal Enclosure complete all as directed. Make:- Havells/ Indo Asian/ Achor/ HPL
Material and labour for point wiring for 15 Amps Socket with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 4 sq mm nominal cross sectional area drawn in and including PVC casing & caping/conduit with all fitting and fixing accessories and 4 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes 1.6 mm thick, 60 mm deep of required size factory made for mounting switch, regulators etc with and including 3 mm thick hylam sheet (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete for the following. Make of wire: Havells, Polycab, Anchor, SCI. Make of casing caping: Finolex, Jindal, Modi, Asian, AKG Note: (i) The quoted rates shall be deemed to be inclusive for fixing the casings caping to surface with using PVC rawl plugs etc. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Supply and fix desert cooler electric driven (single phase) durable plastic body having nominal air flow capacity of Minimum 6000 CuM per hour complete all as directed. Make:- Usha/ Symphony/ Bajaj/ Havells
M&L for plaster of paris moulding/ cornices upto 75mm wide and 50 mm thick as per approved pattern finished smooth and applying two coats of plastic emulsion paint over a coat of primer complete all as directed.
M&L for surface preparartion and then applying one coat of primer, one coat texture finish, again a coat of primer followed by two top coats all as specified and directed by the manufacturer's firm. Make: Asian Paints/ Berger/ Nerolac Note: 1. Company warranty for 06 years to be submitted by the vendor and work to be executed through authorised applicator only. 2. Payment wrt this item will be made only after the submission of completion certificate from manufacturing firm company
M & L for scrapping and Prepration of wall surface and applying 1mm to thick wall care putty followed by a coat of primer and two coats of acrylic emulsion distemper complete all as specified and directed.
M&L for repairing in floor non-skid 6 to 7 mm thick tilling ( skirting and floor) match the existing floors complete all as spfd and directed.
M&L for removal of existing teatment & wall paneling with paint/polish remover and clean the surface by sanding with sand paper and bring the surface in original face over and including prepare the surface with lacker and sealer including lal dana polish with PU thinner with pigment of required shade and finally finish the surface of PU polish / shinner complete all as per manufacturer's instruction and directed by Engr in Charge.
S & F MS angle/ TEE/ Hollow/ tubular section as Steel work in frame work including special shaped washer etc. complete using welding, also fastening and fixing complete all as directed by Engineer - in- charge confirmin g to Fe 410. Make:- Tata Steel,JSW Steel, Jindal Steel
M&L for Anodised aluminium frame Powder Coating as per Item No. 10087 of SSR part-II 2020 (minimum thickness of powder coating 50 micronfor doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. complete all as specified.Make:- Trisul Ind. Meerut,Chandni Ind. Gaziabad,Deco Grill.
S&F for Exibition panel of PVC board of thickness 17-18mm thick density min 500 to be fixed to MS frame work all as directed by Engr in charge . Note :- Contractor are requested to visit the site and office of AGE B/R-II Before quoting rate.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.
Taking down old U/S main switches, Sheatmetal enclosures DB including MCCBs, MCBs etc including making good to the disturbed surface of wall all as directed.
Taking down old unsv T/L, Lamp,Security light of any size and capacity all as directed.
Taking down existing ceiling fan of any capacity and make serviceable by replacing unsv parts and preparation of old painted surface body and blades of ceiling fan of any capacity ,cleaning foreign material ,filling cavaties atc and painting with one coat of synthetic enammeled paint by spray painting and marking MES No. with paint and kept in safe custody and refixing at site after compltion of bldg work.
Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed.
Material and labour for Modular point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in nincluding non rigid PVC Conduit concealed in wall with all fitting not less than 25 mm dia and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including modular metal flush box of required size factory made for mounting Modular switch, regulators etc with and including Modular cover and frame , ISI marked, for the following. Make of wire: Finolex, Havells, Polycab, Anchor,SCI Note: (i) The quoted rates shall be deemed to be inclusive for making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. (ii) Point wiring & earth wire shall be connected to each & every sunken box.
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 31 above but with stranded copper conductor 2.5 Sq mm (nominal area), two single core, PVC insulated cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
Supply and fix modular switch 1 way 6A, 1 Module. Make:- Legrand/ Anchor/ Havells (Crabtree)
Supply and fix modular switch 1 way 16A, 1 Module with indicator lamp. Make:- Legrand/ Anchor/ Havells (Crabtree)
Supply and fix modular socket 6A, 2/3 pin combined 2 Module. Make:- Legrand/ Anchor/ Havells (Crabtree)
Supply and fix modular socket 6A/16A, 2/3 pin combined 2 Module. Make:- Legrand/ Anchor/ Havells (Crabtree)
Supply and fix modular fan regulators step type 2 module 120W . Make:- Legrand/ Anchor/ Havells (Crabtree)
Material and labour for ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed. Make: Anchor, Penta PC SSK, Havells (Reo)
Supply of 10±2 W white body suspended LED Track Light with Aluminium extruded powder coated housing and plastic moulded gear box having 36 deg beam angle, CCT 4000k, CRI 80, PF≥0.95,Clear diffuser with high efficiency Lens optics , COB type , 50000 burning hours with a surge protection of 2.5Kv, input voltage range of 100V - 270V, driver type internal and IP20 Protected. Make:- Havells/ Crompton/ Philips/ Wipro
Supply and fixing of 2mtr length extruded powder coated suspended aluminium track system alongwith End caps & End feed complete all as specified.
Supply and fix of Connector for Track complete all as specified.
Supply and fix of 2m Long Suspension wire for hanging track complete all as specified.
Supply of 1m long surface mounted track for mounting track light on
Supply of 10±2W Suspended Cylindrical shape COB LED Luminaire with High efficiency reflector optics, thermal management, CCT 4000k, CRI 80, PF≥0.90,Clear diffuser with high efficiency Lens optics , COB type , 50000 burning hours with a surge protection of 3Kv, input voltage range of 140V - 280V, driver type internal and IP20 Protected. Make:- Havells/ Crompton/ Philips/ Wipro
S & F sub main wiring with 2 run PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in non-metallic PVC rigid conduit not less than 25 mm dia and including one run PVC insulated unsheathed cable with multi stranded copper conductor as a earth continuity and connected upto DB of following sizes complete all as specified and directed. Note:Two/Four run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. Make: Finolex, Havells, Polycab, Anchor,SCI
2 x 4 + 1 x 4 Sqmm ( For AC Sub main and submain for track Track )
4 x 16 + 1 x 10 Sqmm ( For Main Panel to MCCB DB )
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm thick GI wire by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to main switch board,including all necessary excavation & earth work in hard dense soill including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternate layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed.(one earthing for each main Panel )
S & F MCB SP /SPN complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. All the above-mentioned speification/ technical documents from OEM shall be provided at the time of bidding of MCB SP 240 volts, 50 Hz capacity 6-32 Amps capaity. Make: Legrand, L&T, ABB, Schneider
S & F Distribution boards epoxy powder coated TP & N (VTPN MCCB DB) fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with 250 Amps fully insulated copper Bus Bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 DB,S protection,415 volt ,suitable for fixing FP MCCB 100/125 Amps as incomer and 24 SP MCBs or 4/8/ 12 TP MCBs (or any combination of SP/TP MCBs) outgoings of 8 Way VTPN DB ( FP MCCB +12 MCB ,C). Make :legrand Cat No. 507745 equvilent in L&T, ABB, Schneider capacity and making good the distrubed surface complete all as directed. Note: Suitable MCCB and outgoing MCBs will be measured separately under relavant items of this schedule). Make: Legrand, L&T, ABB, Schneider
S & F MCCB ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 16 KA with thermal-magnetic release and adjustable overload setting . The MCCB shall have a Mechanical life = 40000 operations & Electrical life = 8000 operations 125 Amps capacity complete all as directed. Make: Legrand, L&T, ABB, Schneider
M/s Anamika Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .