Providing and Erecting to LED Flood Street Light Fittings for TRC Garden to Smashan Bhumi at Ukai
342852
E Tender Notice No.18 of 2026-27
Open
Electrical - All
Works
Tapi
9 documents required · 9 mandatory
₹900
Executive Engineer Ukai Division No.1,Ukai
₹21,000
7 Sept 2026
7 Sept 2026
7 Sept 2026
21 Sept 2026
7 Sept 2026
Name of work:- Providing and Erecting to LED Flood Street Light Fittings For TRC Garden to Smashan Bhumi at Ukai
Sr.No Qty Item Rate Rate in Words Per Amount
Replacing Old and u/s by Supplying and erecting Flexible PVC insulated
1 multi strand multi core 1.1 kv grade ISI marked copper wires of following
size to be erected as directed.
(e) 1.50 Sq.mm 3 core round PVC sheathed
Rupees FiftyEight Paise
FiftyEight Only
Replacing Old and u/s by Supplying and erecting LED street light /
Flood light fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt .
LED driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage protection.
(iii) 60 - 89 watts
Rupees Five Thousand Eighty
Paise Thirty Only
Replacing Old and u/s by providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to operate on 240 V A.C. Rupees One Hundred
3 90 system and having breaking capacity 10 KA to be erected in 123.22 TwentyThree Paise TwentyTwo Ea
existing box. confirming to IS 8828/1996 with ISI Mark (B) cat-(III) Only
Replacing Old and u/s by Providing and erecting XLPE (IS:7098)(I)-
88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV.
4 to be laid on wall with necessary clamps or in existing trench /
pipe of following size of cables
(A) 4 core 16 Sq. mm
Rupees One Hundred EightyFour
Paise EightyThree Only
Making trench in Hard Murrum / Tar Road of suitable width of
cm or required depth for laying any size of cable or locating the Rupees SeventyFour Paise
5 1350.00 fault all over the run and back filling the same and making the 74.74 Mtr
SeventyFour Only
surface as normal ground.
(B) If additional machinery like hammer driller or JCB use [Add]
Rupees Three Hundred
FiftySeven Paise FiftyFour Only
Replacing Old and u/s by Providing & laying approved make
Double walled corrugated pipes (DWC) of polyethylene(conforming
to IS 14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of cable.
below ground / road surface for enclosing cable
(A)50 mm outer dia Rupees SixtyTwo Paise
Replacing Old and u/s by Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped
8 with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
15.15 Rupees Fifteen Paise Fifteen Only Ea.
Replacing Old and u/s by Supplying and erecting approved make
Octagonal pole made from HR sheet steel. The pole should be
made as per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed with integral
Junction box consist of terminal plate of min 6mm Hylam sheet,
9 standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud
type terminal and arrangement for cable termination to be erected
With Suitable foundation (Included) as per details given by
manufacturer considering site requirement.
(D) 6 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M20 Bolts and 600mm Rupees Nine Thousand Eleven
long with necessary G.I. J Bolts .Approx Pole weight 59 kg Paise TwentyTwo Only
Providing and erecting street light pole bracket comprising main B
Class GI pipe of 4.2 cm/require outside dia. complete with suitable
B Class G.I sleeve tubing of approx. 45cms.length and suitable for
76.5 mm / 80mm. / require size pole top having sufficient fasteners
for fixing the brackets and having spread of 1 mtr. length with
10 suitable rise as per site condition & suitable welded stiffener
reducer and nipple with check nut complete painted with one coat
of Red oxide / PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms.
[A] Single Arm bracket 0.5 Mtr
Rupees Four Hundred NinetyOne
Paise EightySeven Only
Replacing Old and u/s by Supplying & erecting approved make IP
55 grade Company fabricated Timer Panel of following capacity for
switch On-Off street lights on time scheduling basis made from 16G
CRCA sheet duly epoxy power painted inside and outside with
hinged doors and locking arrangement consisting of suitable size of
11 4 Pole MCB and 4 pole contactor (cat-III)with analog time switch,
auto manual switch of same make and suitable input and output
Bakelite terminals and with door earthing approved by Engineer in
Rupees Seventeen Thousand
FiftyNine Paise NinetyOne Only
Supplying & erecting earth pit of minimum bore dia.150mm size
approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with high charge
dissipation suitable for following type of applications with chamber
and heavy duty cover. (A)(approved make OEM has to submit test
12 certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure
the value of earthing resistane mentioned in test Certificate) &
having back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar
content:- <2%(C) Back fill Compound :- Earthing compound should
be capable to retain moisture for long time Necessary test report
must be submitted by Agency.
(a) For Electrical Installation up to 440V in normal soil Rupees Four Thousand Five
8 Length of pipe - 1 Mtr 4591.46 Hundred NinetyOne Paise Ea
Back filling compound - 1 Nos Bag of 15 Kg. FourtySix Only
Providing and erecting HOT deep Galvanised iron strip/wire Rupees SeventySeven Paise
4.064mm to 1.626mm. SeventySeven Only
I/We am/are willing to carry out the work at ……………………………………………% above/below percent (shouldbe written in figured and words) of the
estimated rates mentioned above. Amount of my/our tender works out as under.
Estimated amount Estimated amount
Put to tender Rs______________ Put to tender Rs______________
Deduct : ___________ % Above RS__________ Deduct : ___________ % Above RS__________
*(Please strike out whitchever is not applicable).
Note 1 – All work shall be carried out as per public works department handbook and other specification of Division ot as directed.
Note 2 – All the columns is schedule should be filled in ink and the total of the entries in the last column should be struck by the contractor under his
Note 3 – Rates quoted include clearance of site (prior commencement of work and at its close ) in all respects and hold good for work under all
conditions, site, moisture,weather etc.
Note 4 – To be continued on additional sheets, if found necessary.
Note 5 - The rates quoted by the Contractor must be inclusive of all taxes prevailing on due date of bid submission except GST. However, any subsequent
changes in the tax structure by Government after due date of bid submission will be compensated (+/-) on availability or submission of actual
documentation. Contractor will have to intimate Engineer regarding changes occurred in the tax structure after bid submission. If the contractor fails to
provide such information and if any financial obligation may arise due to change in tax structure, same will be recovered from the contractor. GST will be
paid separately on the bills. Hence, it is the responsibility of the contractor to pay the GST to the concerned Authority.
Deputy Executive Engineer Executive Engineer
Electric Sub Division Ukai Division No.1
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD LED TRC Ukai.pdf
SCH B 9.pdf
2.0 Special condion Electric (5).pdf
Make List 9.pdf
5.0 Approved make list 2013 2014 Part 1.pdf
6.0 Approved make list 2013 2014 Part 2.pdf
E-Tender Notice No.18 of 2026-27.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .