| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 CrAccepted-AOC | ₹9.3 Cr | L1 | Accepted-AOC Accepted being lowest and quoted amount found reasonable. |
| 2 | L2₹9.6 Cr+₹35 L (3.76%)Rejected-Finance 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹9.6 Cr+₹35 L (3.76%) | L2 | Rejected-Finance Rejected not being lowest |
| 3 | L3₹10.7 Cr+₹1.4 Cr (14.5%)Rejected-Finance | ₹10.7 Cr+₹1.4 Cr (14.5%) | L3 | Rejected-Finance Rejected not being lowest |
| 4 | L4₹11.0 Cr+₹1.7 Cr (18.2%)Rejected-Finance | ₹11.0 Cr+₹1.7 Cr (18.2%) | L4 | Rejected-Finance Rejected not being lowest |
| 5 | L5₹11.5 Cr+₹2.2 Cr (23.4%)Rejected-Finance | ₹11.5 Cr+₹2.2 Cr (23.4%) | L5 | Rejected-Finance Rejected not being lowest |
Tender Value
₹11.0 Cr
EMD Value
₹8.8 L
Closing Date
10 Jun 2020, 6:00 pmClosed
CHIEF ENGINEER
CHIEF ENGINEER (NW) KATARIBAGH, NAVAL BASE-PO KOCHI-682 004
PROVISION OF DEFICIENT ACCN AND SINGLE LIVING ACCN FOR DSC PERSONNELS AT INS ZAMORIN EZHIMALA
2020_MES_322968_1
890923
Open Tender
Civil Works
Lump-sum
545 days
Ezhimala
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,000
Yes
GE(P)Ezhimala
₹8.8 L
Yes
5 Nov 2020
7 Feb 2020
13 Jun 2020
8 Feb 2020
10 Jun 2020
4 May 2020
8 Feb 2020 - 21 Feb 2020
Amount
Total amount of Sch 'A' part-I ( Buildings/Structures)
Total amount of Sch 'A' part-II (Excavation, earthwork,Site clearance & Develoment)
Total amount of Sch 'A' part-III (Internal Electric Supply)
Total amount of Sch 'A' part-IV (Internal Water Supply)
Total amount of Sch 'A' part-V (External Water Supply)
Total amount of Sch 'A' part-VI ( External Electric Supply)
Total amount of Sch 'A' part-VII ( Compound wall /Fencing /Gate)
Total amount of Sch 'A' part-VIII(Road/path/Hardstanding)
Total amount of Sch 'A' part-IX (Sewage Disposal)
Total amount of Sch 'A' part-X (Area Drainage)
Total amount of Sch 'A' part- XI(Fire Fighting)
Total amount of Sch 'A' part- XII (Lightening Protection)
SCH. 'A' PART -XIII (MISCELLANEOUS) Note :- This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
INTERNAL ELECTRIFICATION :- Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. with and including heavy duty non metalic regid PVC concealed conduit medium duty and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with galvanised modular mild steel/pressed steel sunken boxes (with earth dolly) duly electroplated, covered with modular frame and base plate for fixing of modular switches, sockets and fan regulators etc, including on run of PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S. cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- (NOTE: (i) Switches, sockets, regulators to be measured and paid for separately.
(a) All as per item No. 14 but for One light point controlled by one 5/6 amps one way switch complete all as specified and directed.
(b) All as per item No. 14 but for One ceiling fan point controlled by one 5/6 amps one way switch and one fan regulator complete all as specified and directed.
(c) All as per item No. 14 but for One exhaust fan point controlled by one 5/6 amps one way switch and one fan regulator complete all as specified and directed.
(d) All as per item No. 14 but for One Socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin complete all as specified and directed.
(e) All as per item No. 14 but for One Socket outlet, three/five pin, 5 Amp, controlled by by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin. on the same board with other switches, sockets, fan regulators etccomplete all as specified and directed.
(f) All as per item No. 14 but for one light point conrolled by 2 Nos, 2 way switches 5/6 Amps complete all as specified and directed.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. with and including heavy duty non metalic regid PVC concealed conduit medium duty and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with galvanised modular mild steel/pressed steel sunken boxes (with earth dolly) duly electroplated, covered with modular frame and base plate for fixing of modular switches and sockets etc, including on run of PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent board:- (NOTE: Switch and socket to be measured and paid for separately)
Modular switch one way 6 A, 1 module 230 volts 50 Hz ISI Marked complete all as specified and directed. (Make : Crabtree (Athena)/Legrand (Myrius)/Anchor (Panasonic-Roma Plus)
Modular switch two way 6 A, 1 module 230 volts 50 Hz ISI Marked complete all as specified and directed. (Make : Crabtree (Athena)/Legrand (Myrius)/Anchor (Panasonic-Roma Plus)
Modular switch one way 16 A, 1 module 230 volts 50 Hz ISI Marked complete all as specified and directed. (Make : Crabtree (Athena)/Legrand (Myrius)/Anchor (Panasonic-Roma Plus)
Socket modular 6A, 2/3 pin combined, 2 module, AC, 230V, ISI Marked complete all as specified and directed. (Make : Crabtree (Athena)/Legrand (Myrius)/Anchor (Panasonic-Roma Plus)
Socket modular 16A, 2/3 pin combined, 2 module, AC, 230V, ISI Marked complete all as specified and directed. (Make : Crabtree (Athena)/Legrand (Myrius)/Anchor (Panasonic-Roma Plus)
Step type in 5 stages fan speed regulator 2 module 230 volts 50 Hz ISI Marked complete all as specified and directed. (Make : Crabtree (Athena)/Legrand (Myrius)/Anchor (Panasonic-Roma Plus). Note for Item Nos 22 to 27 : Control switches/Regulator for light/ceiling fan for living rooms shall be provided separately for each bed as per bed layout approved by User.
Ceiling rose three terminal 230 volts 50 Hz ISI Marked complete all as specified and directed.
Ceiling fan 1200mm sweep copper wound having service value > 4.5 as per IS 374.2019 (2 star) including 3 core flexible PVC insulated multistranded copper conductor cable of size 0.5 Sqmm” Note: Ceiling fan shall be fixed with suitable length of down rod as per site requirement to maintain standard height and rate shall deemed to be included in the quoted rate.
Exhaust fan 250 mm sweep 230 Volts AC 50 Hz PVC body with copper wound having Energy Efficient model including all as directed complete all as specified and directed. Make : Crompton (model Brisk air) or equivalent make in the list of manufactures.
Exhaust fan 450 mm sweep 230 Volts AC 50 Hz metal body with copper wound having Energy Efficient model two Nos ball bearing heavy duty, IP-55, 1400 RPM complete all as specified and directed at site.Make Crompton Model No Exhd450-4-1 ISI or equivalent make mentioned in the list of make.
Exhaust fan 300 mm sweep 230 Volts AC 50 Hz metal body with copper wound having Energy Efficient model 1350 RPM complete all as specified and directed at site.Make Crompton Model No DRIFT Air Plus ISI or equivalent manufacturers from list of manufacturers
LED Tube light 1X20 Watt 4' universal battern type with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and directed at site of Make/Model:- (a) Fitting: Crompton Cat Part No DIJB12LT8 ECO (b) Lamp: Crompton Cat Part No LT8-20-865-(2) ULTRON or equivalent manufacturers from list of manufacturers
LED light 1X10 Watt 2' with and including connecting 3 core 1.0 Sqmm PVC insulated multistranded copper conductor color of sleeve matching to fitting and connecting up complete all as specified and directed at site of Make/Model:- (a) Fitting: Crompton Cat Part No DMLN1LT8-8 UNILITE (b) Lamp: Crompton Cat Part No LT8-8-865-2 ULTRON or equivalent manufacturers from list of manufacturers
LED surface mounted corridor light 1X10 Watt fitting including connecting 3 core 1.0 Sqmm PVC insulated multistranded copper color of sleeve matching to fitting and connecting up to fitting complete all as specified and directed. Fitting with Lamp: Crompton Cat Part No LCRP-10-CDL or equivalent manufacturers from list of manufacturers.
Bulkhead 1X10 Watt fitting with and including connecting 3 core 1.0 Sqmm PVC insulated multistranded copper color of sleeve matching to fitting and connecting up the fitting complete all as specified and directed at site. Fitting with Lamp: Crompton Cat Part No LBHP-10-CDL STUD or equivalent manufacturers from list of manufacturers.
Building security light newgeneration energy saving and environmental friendly long life LED streetlight made of pressure die cast alluminium housing with hogh power LED as lighting source and lens embded PC cover having TOP OPENING seperade driver compartment with IP66 protection and impact resistance of IK 07 complete with and including wall mounted bracket fabricated out of 40mm GI pipe light grade bend to shape1.5 mtr long and two nos wall mounting clamps using 25x4mm thick MS strip bend to shape and welded with pipe to form solid structure and one run of 1.0 sqmm PVC insulated multistranded copper cunductor wire conecting pvc terminal to fitting complete. (Make Crompton Model No LSTS-25-CDL-M ASTRA NEO) or equivalent in Philips/Wipro or equivalent manufacturers from list of manufacturers
Sheet metal enclosures with socket and plug top and MCB single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp 230 volts for solar water heater/apparatus or equivalent manufacturers from list of manufacturers
MCCB DB VTPN 6 way double door 415 Volts with provision for MCCB as incomer and SP/TP MCBs as out going with IP 43 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 including cement spill protector. Make Legrand Cat No 507746 or equivalent manufacturers from list of manufacturers.
MCCB DB VTPN 4 way double door 415 Volts with provision for MCCB as incomer and SP/TP MCBs as out going with IP 43 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 including cement spill protector. Make Legrand Cat No 507745 or equivalent manufacturers from list of manufacturers.
MCCB 4 pole of current rating capacity 160 Amps with breaking capacity Icu AC 25kA @ 415V AC 50 Hz conforming to IS/IEC 60947-2 & EN 60947-2 of thermal magnetic release with ON-TRIP-OFF indication. Make Legrand 420057 or equivalent manufacturers from list of manufacturers.
MCCB 4 pole of current rating capacity 100 Amps with breaking capacity Icu AC 16kA @ 415V AC 50 Hz conforming to IS/IEC 60947-2 & EN 60947-2 of thermal magnetic release with ON-TRIP-OFF indication. Make Legrand Cat No 420055 or equivalent manufacturers from list of manufacturers.
MCCB 4 pole of current rating capacity 40 Amps with breaking capacity Icu AC 16kA @ 415V AC 50 Hz conforming to IS/IEC 60947-2 & EN 60947-2 of thermal magnetic release with ON-TRIP-OFF indication. Make Legrand Cat No 420002 or equivalent manufacturers from list of manufacturers.
MCB TPN 63 Amps 10kA 'C' curve Make Legrand Cat No 408683 or equivalent manufacturers from list of manufacturers.
MCB TP 63 Amps 10kA 'C' curve Make Legrand Cat No 408661 or equivalent manufacturers from list of manufacturers.
MCCB 4 pole cap 63 Amps 16kA 'C' curve. Make Legrand Cat No 420013 or equivalent manufacturers from list of manufacturers.
Sheet metal enclosure distribution board TPN DB 415 V, AC, 4 way with 200 Amps rated bus bar suitable for MCB four pole as incomer and MCB's SP/TP as outgoing having protection IP 43, double door type with arcylic cover. Make Legrand, Cat No 507680 or equivalent in Schneider/L&T
Sheet metal enclosure distribution board MCB DB SPN 12 way with metal double door 240 Volts with IP-43 protection including door earthing complete all as specified.Make Legrand Cat No 507612 or equivalent manufacturers from list of manufacturers.
Sheet metal enclosure distribution board MCB DB SPN 8 way with metal double door 240 Volts with IP-43 protection including door earthing complete all as specified.Make Legrand Cat No 507611 or equivalent manufacturers from list of manufacturers.
Sheet metal enclosure distribution board MCB DB SPN 4 way with metal double door 240 Volts with IP-43 protection including door earthing complete all as specified.Make Legrand Cat No 507610 or equivalent manufacturers from list of manufacturers.
MCB SPN 6-32 Amps 10 kA with charaterestic "B/C" Curve. Make Legrand Cat No 408609 to 408617 or equivalent manufacturers from list of manufacturers.
RCBO 32 Amps, DP, 240V, AC type, 30mA. Make Legrand Cat No 411395 or equivalent manufacturers from list of manufacturers.
MCB SP 06-32 Amps 10 kA with characteristic "B/C" curve conforming to IS/IEC 60898. Make Legrand Cat No 408587 to 408595 or equivalent manufacturers from list of manufacturers.
MCB TP 40 Amps 10 kA with charaterestic "C" Curve. Make Legrand Cat No 408659or equivalent manufacturers from list of manufacturers
MCB TP 20 Amps 10 kA with charaterestic "C" Curve. Make Legrand Cat No 408656 or equivalent manufacturers from list of manufacturers
MCB TPN 40 Amps 10 kA with charaterestic "B/C" Curve. Make Legrand Cat No 408681or equivalent manufacturers from list of manufacturers
MCB TPN 20 Amps 10 kA with charaterestic "B/C" Curve. Make Legrand Cat No 408678 or equivalent manufacturers from list of manufacturers
Submain wiring with 2 runs of 2.5 Sqmm PVC insulated unsheathed copper conductor multistranded FRLS cable drawn in and including PVC conduit and its accessories laid in concealed in wall/roof/floor etc including one run of 2.5 Sqmm multi stranded copper conductor cable for earth continuity wire complete all as specified and as directed. (Note: Three runs of 2.5 sqmm wire and one run of PVC concealed conduit shall be measured as one run only
Submain wiring with 2 runs of 4 Sqmm PVC insulated unsheathed copper conductor multistranded FRLS cable drawn in and including heavy duty PVC conduit and its accessories laid in concealed in wall/roof/floor etc including one run of 4 Sqmm multi stranded copper conductor cable as earth continuity wire complete all as specified and as directed. (Note: Three runs of 4 sqmm wire and one run of PVC concealed conduit shall be measured as one run only
Submain wiring with 2 runs of 6 Sqmm PVC insulated unsheathed copper conductor multistranded FRLS cable drawn in and including heavy duty PVC conduit and its accessories laid in concealed in wall/roof/floor etc including one run of 6 Sqmm multi stranded copper conductor cable for earth condinuity wire complete all as specified and as directed. (Note: Three runs of 6 sqmm wire and one run of PVC concealed conduit shall be measured as one run only
Submain wiring with 4 runs of 6 Sqmm PVC insulated unsheathed copper conductor multistranded cable drawn in including heavy duty PVC conduit and its accessories laid in concealed in wall/roof/floor etc including two run of 6 Sqmm multi stranded copper conductor cable for earth condinuity wire (Note: Four runs of PVC cable 6 sqmm and 02 run of 6 sqmm earth condinuity conductor cable and PVC conduit will be measured as one unit length only)
INTERNAL WATER SUPPLY:- Stop cock angular 15/20mm bore with wall flange complete of make Jaguar Cat part No CQT-23059or equivalent manufacturers from list of manufacturers.
Bib cock with wall flange complete of make Jaguar Cat part No CQT-23047 or equivalent manufacturers from list of manufacturers
Pillar cock with wall flange complete of make Jaguar Cat part No CQT-23021B or equivalent manufacturers from list of manufacturers
Health faucet/ hand shower with 8 mm dia, wall hook and easy flexible tube in crome finish1.5m long with nuts of make Jaguar cat part No ALD573 and SHA571 or equivalent manufacturers from list of manufacturers
Over head shower rose 100mm dia round shape single flow ABS body chrome plated wirh grey face plate and Rubi/ cleaning system alongwith shower arm casted120mmlongheavy body round shape for wall mounted shower with wall flange complete of make Jaguar cat part No OHS1989 and SHA-487 or equivalent manufacturers from list of manufacturers
Stop cock long body combination of exposed part kit of consealed stop cock with fitting sleave, operating knob, adjustable wall flange and regular body concealed stop cock suitable for 15mm pipe line with protection cap of make Jaguar cat part No CQT-23082K and ALD083 or equivalent manufacturers from list of manufacturers
EXTERNAL WATER SUPPLY:- Rotational mounted polyethylene water storage tank of 10000 ltr capacity (cylinder vertical with closed top) hoisted and fixed in position including foundation all as specified and as directed.
Cutting existing CI tubing 80/100 mm dia for alterations / additions,including CI specials like 80 x 80 x 80 mm CI Tee, flanged socket 80mm including necessary excavation and making good the surface all as specified. ( Each cut measured )
25mm dia Gate valve including fittings etc complete all as specified and directed.
Non return valve 50mm dia including fittings etc complete all as specified and directed.
Monoblock pumpset, 3 phase, 415V, 30M Head, 250 LPM complete all including MCB, DOL starter, PCC foudation etc (One working + One stand by) Note:- The rate quoted by contractor shall include control MCB, DOL starter, PCC foundation etc complete all as specified and directed.
Provision of masonry valve chamber of 0.6 x 0.6 x 0.6M internal size including 100 mm thick PCC (1:5:10) type E2 foundation, brick working CM (1:6) plastering internal suffaces completely and external surfaces upto 150 mm belowground level, 15 mm thick in CM (1:4) 100MM THICK (1:3:6) TYPE C1 coping 80x50x6 mm angle iron, 6 mm thick MS plate cover complete with'handle'locking arrangement inclouding painting steel and iron surfaces with two coats of synthetic enamel paint of tint as directed over a coat red oxide complete all as shown on drawing No CE DD /TD/119 sheet1 / 1 Note: The quoted rate inclusive of MS cover and locking arrrangements as per the drawings.
EXTERNAL ELECTRIC SUPPLY:- XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts (E) grade with stranded aluminium conductor of size 4 core 10 sqmm complete all as specified and directed.
XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts (E) grade with stranded aluminium conductor of size 4 core 25 sqmm complete all as specified and directed.
XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts (E) grade with stranded aluminium conductor of size 3.5 core 35 sqmm complete all as specified and directed.
XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts (E) grade with stranded aluminium conductor of size 3.5 core 185 sqmm complete all as specified and directed.
Supply install test and commissioning of LT panel board CPRI approved with CRCA Sheet steel 3 mm thick outdoor type cubical comparmentalised, having busbar capacity 400A, ammeter with CT's, voltmeter, indicating lamps with and following breakers as incoming and Outgoings Incoming 4 pole MCCB 250A, 415V, 50Hz with breaking capacity 36 KA, O/C and E/F protection - 01 No. Outgoing 4 pole MCCB 200A, 415V, 50Hz with breaking capacity 36 KA, O/C and E/F protection - 01 No (Internal DB) 4 pole MCCB 100A, 415V, 50Hz with breaking capacity 25KA, O/C and E/F protection - 01 No (FF).
Supply install test and commissioning of LT panel board CPRI approved with CRCA Sheet steel 3 mm thick outdoor type cubical comparmentalised, having busbar capacity 400A, change over switch 4 pole 63 A in open execution all as specified and as directed. (Main panel) Incoming 4 pole MCCB 200A, 415V, 50Hz with breaking capacity 25KA, O/C and E/F protection - 01 No Outgoing MCCB FP 100A, 415V, 50Hz with breaking capacity 25KA-03 Nos (01 Buiolding + 1 Spare), MCCB FP 63A, 415V, 50Hz with breaking capacity 25KA, (01- Kitchen, 01- DG Panel)
Supply install test and commissioning of out door floor mounting type LT panel board made out of thermo plastic poly carbonate suitable for 415V 3 phase 4 wire 50Hz non metallic kiosk with provision of switch gear and control gear enclosed in a modular/combinable panel enclosure with IP 65 protection ( DG panel) Incoming MCCB 100A FP 415V, 50Hz with breaking capacity 25 KA, O/C and E/F protection - 01 No. Outgoing MCB TPN 32A, 10 kA-03 Nos (01 -FF pump, 01 -spare) MCB TPN 20A, 10 kA-02 Nos (01 -Lift, 01 -water pump) MCB SPN 16A, 10 kA-02 Nos (01 -street light, 01 -spare) MCB SPN 32A, 10 kA-02 Nos (01 -Common light, 01 -spare) Busbar TP & N 200 Amps, Aluminium bus bar E 91 grade 1100 V , grade duly covered with heat shrinkable, sleeves colour coded duly fixed on moduled brackets-01 Set. Timer switch, single phase 230 V, 16 A -1 No
Steel tubular swaged poles Type 410SP-31 (9.0 meter long) Swan Neck Type complete with CI base plate and finial tapper plug, bolts, nuts and washers and single swan neck, including 3 coat of bitumen paint internally complete and externally for the portion embedded in concrete and two coats of aluminium paint over a coat of red oxide primer to the balance portion of external surface and all as specified and directed. Note : Excavation and PCC shall be measured and paid seperately under relevent item of schedule "A" foundation and coping.
LED street light fitting 120 W die cast aluminium housing 7700 lumen light output, 5KV surge protection, power factor 0.95 THD less than 10%, IP65 protection and heat resisitant toughened glass with frame including all accessories and suitable bracket made out of GI pipe medium grade of dia 40 mm and length 1.6m bend in shape fixed on street light poles including mounting clamps and connecting wih flexible copper wires etc and tesing on completion. all as specified and directed. Make:CG model No LSTP-120-CDLor equivalent manufacturers from list of manufacturers.
Terminal box with MCB SP 6 amps and 4nos busbar with connection to sintex box of size 300x200x105 mm to street light fittings with 3 core 2.5 sqmm stranded copper wire 8.5 RMX 3 run including complete all as specified and as directed,
Modification of existing LT panel by Supply, installation and commissioning of LT panel board fabricated with CRCA Sheet steel 3 mm thick cubical outdoor type, comparmentalised, having busbar capacity as existing, ammeter with CT's, voltmeter, indicating lamps with and including 4 pole MCCB 315A,36 KA - 1 No complete all as matching to the existing LT Panel.
Doom post top lantern LED light 12W with all accessories
Earthing complete with galvanised steel earth plate electrode of size 600mm x600mmx6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including galvanised strip 32 x 6mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 140mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.
All as per 97 above but 4mm dia GI wire as earth lead
Modification of existing LT panel by providing of MCCB FP 200 A, 35 KA, 415 V with sheet metal enclosure made of 3mm CRCA sheet with angle iron frame 50x50x6mm suitable height and foundation etc complete at sub/stn 18.
Modification of existing DG panel by providing of MCCB, FP 100 A , 25 Ka 415 V with sheet metal enclosure made of 3mm thick CRCA sheet with angle iron 50x50x6mm suitable height and foundation etc complete at sub/stn 18.
Riddled soil as earth cushioning to UG cable by using IS sieve to separate the composite particle/roots etc and refilling/spread in trenches as cushioning and rammed down to form a solid bed all as specified and as directe. Note:-Punned thickness shall be measured and paid seperately
Miscellaneous Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. of dia 40mm all as specified and as directed.
Modular TV socket as following: TV socket 1 module Make :Legrand Cat Part no 675546 -01 Nos (b) Modular with plate for TV socket 1 No Make :Legrand Cat Part no 674517 (c ) Plastic flush boxes for 1 module jack Make :Legrand Cat Part no 673302 -01 Nos all as specified and as directed.
COOLING APPLIANCES :-Supply and installation of water cooler Electric driven (single phase), SS body having approx flow rate 125 Ltrs/Hr, with storage capacity 85 Ltrs (Normal-40 Ltrs/Cold-40Ltrs/Hot-5 Ltrs) with electronic water purification system RO & UV and normal,hot and cold water outlet complete. Make : OZONE (Model-ERWINA 120 NHC SSS (RO+UV) or equivalent make of BEST WATER DOCTOR /Cross fields water purifier
Supply and installation of Refrigerator electric driven (single phase), 190/192 Ltrs capacity, 5 star rated single door . Make: Samsung/Voltas/Whirl pool/LG or equivalent manufacturers from list of manufacturers
Supply and installation of Deep freezer metal top electric driven (single phase), 320 Ltrs capacity double door Make Samsung/Voltas/Whirl pool/LG or equivalent manufacturers from list of manufacturers
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 100V to 290V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA . Make V Guard (Model-VGMW 200) or equivalent manufacturers from list of manufacturers
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 100V to 290V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA . Make V Guard (Model-VGSD 100) or equivalent manufacturers from list of manufacturers.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 100V to 290V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 500VA . Make V Guard (Model-VGSD 50) or equivalent manufacturers from list of manufacturers.
HOT WATER SUPPLY :--Supply, Install, Testing and Commissioning of 'Solar Hot Water Sytem' (Flat Plate Collector) based on indirect transfer of heat of capacity 100 LPD with electrical backup.
Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore all as specified and as directed.
Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore all as specified and as directed.
15 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specfied and as directed.
20 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specfied and as directed.
25 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specfied and as directed.
15mm dia chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specfied and as directed.
Rotational mounted polyethylene water storage tank of 250 ltr capacity (cylinder vertical with closed top) hoisted and fixed in positionall as specfied and as directed.
Site Clearence :- Picking and stacking of stone boulders spread over area stacking neatly for calculating meassurements all as specified and as directed
FIRE FIGHTING :- Fire fighting Terrace pump electrically driven working on 440V, 3phase, 50Hz, horizontal end suction, centrifugal type confirming to IS:12469-1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation 0% to 150% of rated discharge capacity 900 LPM @ 30M head complete all as specified and directed. (01 as Main pump & 01 as standby)
Fire Fighting Motor control panel outdoor type made from 3 mm thick CRCA sheet, suitable for working 02 Nos terrace pump (1W+1S) appx capacity 15 HP on Auto mode complete with MCCB as Incomer, Bus bar, Motor starter, Mulifunction meter etc including internal wiring from automatic pressure switch, wiring from Panel to Motor complete all as specified and directed and OEM requirements.
MS pipe IS - 1239 marked (heavy duty) exposed in multi storied building including all fittings like coupling, bends, elbows, tees etc. and suitable fixing arrangement for pipe support such as MS round, angles, channels, plate including cutting to size welding and making good walls, ceiling and floors, welded or screwed joints as required, cutting holes and chases in walls complete including painting the whole surfaces of MS pipe with synthetic enamel paint as per colour code over two coats of zinc chrome primer all as specified and as directed. (a) 150mm dia
All as per item No.110 above but 100 mm dia pipe
All as per item No.110 above but 80 mm dia pipe
Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete all as specified and directed.
Fire Hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white, double door with glass front lock and key arrangement,with and including the following items as specified and as directed. a) First aid hose reel wall mounted swinging type fitted with 20mm dia 30.0 M long high pressure branded rubber hose with 6mm dia gun metal shut off nozzle and 25mm dia inlet valve confirming to IS 884-1969-1No b) Cotton syntetic fiber circular woven jacketed rubberised fibre reinforced rubber line fire hose 63mm dia 15M long ( bursting pressure 35.7 kg / cm sq.) IS 636 type A with gun metal female cuppling (IS 903 - 1973)- 2 Nos. c) Landing valve hydrant type A, confirming to IS 5290-1993 with 63mm dia gun metal instanous single headed out let complet with whole accessaries for connecting hose pipe- 1Nos d) standard gun metal branch pipe with gun metal nozzle 15mm bore outlet- 1 set
Fire Alarm Hooter, intelligent, addressable, (sound output of minimum 90 dB upto a distance of 10 feet) with strobe light of minimum 75 cd intensity with power supply arrangement complete as required and suitable for wall/ceiling mounting complete all as specified and directed.
4 core 1.5 sqmm stranded copper conductor, PVC insulated PVC sheathed, aluminium myler tape shielded FRLS armoured cable buried in ground or laid in existing pipe complete all as specified and directed.
Wall mounted LED emergency Exit siguage luminaire lit up using regular mains supply comes with a unique rechargeable Ni-cd battery capable of emergency back up upto 05 hours complete all as specified and directed. Make: Cat No LSSR5W of CG or equivalent make listed in list of manufactures
Manual push button to initiate audio alarm with a breakable glass cover/resettable, intelligent addressable type complete all as specified and directed.
FACP of micro processor based 2 wire fault tolerant loop, required loop for minimum 200 addressable detectors and 200 addressable modules ( each loop accessing minimum 99 detectors and 99 modules) fire alarm/detection control panel. The panel shall be able to give location of all fire /fault conditions of addressable units via the address codes. Further the panel must be able to automatically switch ON/OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, LCD unit to indicate fire fault signal with address and analog output,external/inbuilt printer to log all fire/fault events complete in all respects.The panel shall have integrated fire fighters telephone command centre and it shall annunciate 10 fire fighter telephone zones through touch/key pad.The panel shall include 10 control modules for fire fighter telephone zones.The panel shall have a built in power supply and battery charger alongwith maintenance free 24 AH, 2 x 12 Volt SMF lead acid batteries capable of running for a minimum of 8 hours with battery charger complete all as specified and directed.
Fire alarm sounders/Sirens electronic type horizontal single stage continuous nomal operation for atleast 50 minutes with sound level 65 db to 120db meassured at 1.5M with sound output variation of +5 db 500M range complete all as specified and directed.
XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts (E) grade with stranded aluminium conductor of size 2 core 1.5 sqmm complete all as specified and directed.
Sluice valve class PN 1.6 complete all as specified and directed.
Automatic air release valve 50mm dia suitable foe domestic water with 50mm gun metal stop valve complete all as specified and directed.
Fire Alarm Siren, intelligent, addressable, with electrical contactor relay and linked to the main fire alarm panel ( sound output of minimum 90 dB upto a distance of 1 km) complete as required and suitable for wall/ceiling mounting and as per specifications.
Item No. 125 Continued.. Stainless steel hair line finish Car operating panel inside car with floor destination buttons along with door open/close, emergency alarm, press and speak type intercom and attendant switch to be provided with 16 segment LED/Dot Matrix Dynamic Car Direction display and Digital position indicatiors,Stainless steel hair line finish for narrow door frames or as approved.
Item No. 125 Continued.. (c) PARAMETERS COMMON TO LIFT : - 3 phase, 415 V/220V, 50 Hz Power Supply, Acceptable Voltage Fluctuation +10 to -10% , Rate of acceleration/Deceleration 0.6-1.5 M/S2 , Jerk 0.7-1.6 (m/Sec3) , Horizontal vibration - a(xmaxPtP) & a(ymaxPtP)- Max 20mg, a(xA95) & a(yA95) - Max 15mg, Vertical vibration: - a(xmaxPtP) & a(ymaxPtP)-Max 20mg, a(xA95) & a(yA95) - Max 15 mg, Airborne noise level in Car (ISO 18738:2003)- L (Aeq) - Max 48 dB (A), L (P)- Max 57 dB(A), Airborne noise level at landing door- Door movement noise L (p_door)- Max 52 dB (A), Pass by noise- L(p_landing)- Max 48dB(A), Stopping accuracy & Leveling Accuaracy - +/- 3 mm to +/- 5mm, Direct drive doors with PMS motor and closed loop VVVF door control,Car panel and door panel thickness- At least 1.50 mm.
Item No. 125 Continued.. (d) FIXTURES/SIGNALS INSIDE CAR (Stainless steel car operating panel with following buttons and indications) : - Door open/door close buttons with symbol markings. Door hold button for service lifts,ARD operation audio/Visual indication in car,Emergency alarm button with bell symbol and the same should be at distinct distance from the call buttons. Emergency alarm button to be located along-with door open and close buttons at a height of 900 + 10 mm from floor level. Yellow pictogram to be provided, Alarm sound shall be siren type audible from at least 50 meters from the ground floor landing, Ventilation fan ON/OFF switch with auto switch off feature after 120 seconds lift at idle condition, Two position key operated attendant switch for with/without attendant operation, LED illuminated tactile braille buttons of micro motion type corresponding to the floors served. The push buttons to be of robust SS vandal resistant type, Three-way built in press and speak type with 1 master and 2 slave units in security room/control room. Additionally, wiring provision for connecting building EPABX with car phone with rechargeable batteries,16 segment, LED/Dot matrix car direction display and digital position indicators located at a conspicuous height above car door for passenger Lift (Bidder to provide inputs on car displays),
Item No. 125 Continued.. Emergency light with rechargeable sealed maintenance free battery with 30minute backup, Emergency alarm with rechargeable sealed maintenance free batteries rated for 30minute backup, Audio/visual over load warning indicator, Floor position voice announcement with back ground music.
Item No. 125 Continued.. (e) LANDING INDICATORS : - Two landing buttons with position indicator in all floor,Chime on car (f) PROVN OF HANDICAP FRIENDLY FEATURES IN PASSENGER LIFTS: - SS mirror hand rail on rear side only, Braille marking buttons on car operating panel and landing push buttons have braille inscriptions, Voice announcements to announce the floor position, Multi beam infrared protection device to reverse the closing door in case of slight obstruction in the door way. (g) SAFETY FEATURES AND OTHER INCLUSIONS : - Fire man’s switch for the lifts at ground floor level. The lifts to have fire man mode – stage 1 and fire lift to be with stage 1 and 2, Multi beam infrared protection device to reverse the closing door in case of slight obstruction in the door way, Automatic phase reversal device, Overload, non-start and overload protection two Nos earthing with earth continuity conductor complete as directed for control panel. Cost for the same shall be deemed to the quoted rate. Device, Spring buffers, Electro mechanical type safety governor for car, DO’s and Don’ts with emergency contact numbers engraved on
Item No. 125 Continued.. SS face plate displayed in the car as for safety instructions, Terminal and final limit switch provn for Over travel protection, Controller/driver/motor protection - Trip device for over current, under voltage and over voltage than the rated capacity +/- 10%, Motor over load/over torque, Instantaneous over current, Ground fault, Under voltage, Over voltage – 3 phase, Output & input phase loss, Phase reversal, Output short circuit , Over speed, Spike and surges. ARD battery operated with and including of any maintenance free batteries of suitable capacity and battery charger with optimum direction in start operation and requiring no human intervention, rescue clearing, power/system failure with latest IGBT power devices, Landing door to have 2 hour fire resistance rating. Car doors as per requirements, Intercom connection in Car and control room and also in security room., Provision of suitable cables along the travelling cable for fire detector and music inside the car, Provn of one car blower to be connected through power supply, Full height fascia plates and sill angles to be provided. Apron of min height 750 m to be provided at car side, epoxy coated MS pit ladder of height more than pit depth to be provided and securely fastened inside the pit, System memory should be retained in the event of power failure or disturbance. Lifts should not go in to correction mode or correction run to the lowest floor/highest floor to update its position and memory.
Item No. 125 Continued.. Safe landing feature:- If a car has stopped between floors due to some equipment malfunction, the controller checks the cause, and if it is considered safe to move the car, the car will move to the nearest floor at low speed and the door will open. Ascending over speed protection device, Unintended car movement protection device,Earth quake operation if required under lift act for Kanoor region- Seismic sensors and auto isolation arrangement for safety & Counter weight derailment device or displacement switches to be provided. Other functions – anti nuisance, car call cancellation, next landing, bye pass, self levelling, door time adjustment, independent operation and return operation. Misc - Elevator (lift) related civil work and steel work required for installation of lift, Mirror polished 20mm thick black granite facing at entrance of door and at cill at lintel level of 40 cm wide. Note:-(1) The work of lift design, supply installation testing and commissioning will be executed by the lift manufacturers as per the List of Manufacturers .The manufacturers of these lifts be refered as OEM for lifts only in this tender. (2) The OEM or the agency authorised to carry out maintenance of lifts by OEM as per Sch 'A' provisions and relevant items of BOQ will be permitted to undertake maintenance of lifts as per item Nos.133 to 135 of BOQ
COMPREHENSIVE MAINTENANCE OF LIFT:- Comprehensive maintenance of electrically operated gearless passenger lift through OEM for 544 Kg capacity lift- to serve (G+4) building all as mentioned in relavent items of this BOQ complete all as specified and as directed for First year after expiry of defects liability period.
All as per item No. 133 here in before but for Second year after expiry of defects liability period.
All as per item No.133 here in before but for Third year after expiry of defects liability period. Note :-One final Bill for comprehensive maintenance of lift at completion of works under item No. 133 to 135.
A2Z ENGINEERS AND PILE FOUNDATIONS
Modern Engineering Co
M/s Kishan Gopal Agarwal
K THOMAS AND COMPANY
JAIN BUILDER
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .