Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC NO 28 KUMHARON KI BASTI DHOONDHA BARMER RAJASTHAN 344035 | BARMER | RAJASTHAN | 344035 | ₹33.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹34.0 LRejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 UDYAM GJ 05 0006749 24AACFK2418A1Z4 B R MSME STATUS AS VERIFIED | BHAVNAGAR | GUJARAT | 364001 | ₹34.0 L | L2 | Rejected-Finance Not Lowest Bidder, Hence rejected |
| 3 | L3₹35.7 LRejected-Finance PACHPADRA ROAD OPP MILK DAIRY BALOTRA TEHSIL PACHPADRA DISTT BALOTRA RAJ | GANGANAGAR | RAJASTHAN | 335001 | ₹35.7 L | L3 | Rejected-Finance Not Lowest Bidder, Hence rejected |
| 4 | L4₹35.9 LRejected-Finance | ₹35.9 L | L4 | Rejected-Finance Not Lowest Bidder, Hence rejected |
| 5 | L5₹36.5 LRejected-Finance 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | ₹36.5 L | L5 | Rejected-Finance Not Lowest Bidder, Hence rejected |
| Sl No | Description | Qty | Unit | KRISHNA CONSTRUCTION COMPANY L2 | L C ASSOCIATES L4 | Mahaveer Traders L5 | M/S BHERA RAM & SONS L3 | DEVARAM CONSTRUCTION COMPANY L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing and testing desert cooler electric driven (single phase), with over all dimension 690mm x 620mm x 890mm having tank capacity 50 Ltrs with fan of size 500mm, grass padded walls with motor arrangement for air circulation , motor should be ISI marked with variable speed ( High 1400 RPM, Med 1300 RPM, Low 1250 RPM ) efficiancy of fan motor should be 40% with PF>0.85 totally enclosed, water pump of haed 5ft , having nominal air flow capacity of 4000 CuM per hour including plug top , necessary accessories (or nearest size) complete all as specified and as directed
Note:- Rate of taking down Old BER Desert Cooler from existing site to MES Store Yard shall be included in quoted rate | 53 | EACH | 11,000 ₹5.8 L | 11,500 ₹6.1 L | 15,000 ₹8.0 L | 11,550 ₹6.1 L | 11,000 ₹5.8 L |
| 2.00 | S & F Exhaust fan heavy duty size sweep 300 mm sweep, 230 v, 50 Hz , complete with metalic louvers including making holes and making good the disturbed surface and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed .
Note:- Rate of taking down Old BER Exhaust fan from existing site to MES Store Yard shall be included in quoted rate | 26 | EACH | 3,000 ₹78,000 | 3,100 ₹80,600 | 3,000 ₹78,000 | 3,150 ₹81,900 | 2,800 ₹72,800 |
| 3.00 | Supply and fixing Single phase ceiling fan 1200 mm permanent magnet brushless DC Motor 230 v 50 Hz single phase 26-35 watt rated pf 0.98 360 rpm air delivery 220m3, 5 star with rated service value min 6m2/min/watt with 5 Year Warranty, no of blades three type of blade leaf min 1.05 mm thick aluminium sheet remote control radio frequency 5 speed +off timer option speed regulation class of insulation two nos bearings including connecting wire, remote with cell complete with all as required and directed.
Note:- Rate of taking down Old BER Ceiling fan from existing site to MES Store Yard shall be included in quoted rate | 48 | EACH | 2,500 ₹1.2 L | 2,600 ₹1.2 L | 2,500 ₹1.2 L | 2,625 ₹1.3 L | 2,450 ₹1.2 L |
| 4.00 | Supplying and fixing,testing the water heater storage type 25 litres, BEE Five star rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall incl all accessories , Hot and Cold pipe, plug top and making good the disturbed surface, complete all as required and as directed .
Note:- Rate of taking down Old BER Geyser from existing site to MES Store Yard included in quoted rate | 29 | EACH | 10,000 ₹2.9 L | 10,500 ₹3.0 L | 10,000 ₹2.9 L | 10,500 ₹3.0 L | 9,900 ₹2.9 L |
| 5.00 | Supply ,fixing and installation inverter split AC units indoor/outdoor copper condenser , digital display, heavy duty compressor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed | 4 | EACH | 60,000 ₹2.4 L | 62,000 ₹2.5 L | 60,000 ₹2.4 L | 63,000 ₹2.5 L | 59,000 ₹2.4 L |
| 6.00 | Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed. | 4 | EACH | 6,000 ₹24,000 | 6,500 ₹26,000 | 6,000 ₹24,000 | 6,300 ₹25,200 | 5,900 ₹23,600 |
| 7.00 | S & F copper pipe size 1/4'' size including connected two copper pipe by brazing complete all as specified and directed. | 20 | Ft | 200 ₹4,000 | 210 ₹4,200 | 200 ₹4,000 | 210 ₹4,200 | 190 ₹3,800 |
| 8.00 | S & F copper pipe size 1/2'' size including connected two copper pipe by braging complete all as specified and directed. | 20 | Ft | 200 ₹4,000 | 210 ₹4,200 | 200 ₹4,000 | 210 ₹4,200 | 190 ₹3,800 |
| 9.00 | S&F of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed. | 4 | EACH | 800 ₹3,200 | 850 ₹3,400 | 800 ₹3,200 | 840 ₹3,360 | 750 ₹3,000 |
| 10.00 | S & F in of PVC insulated 3 core copper PVC insulated FRLSH cable of size 4.0 Sqmm, flexible cables, 1100 Volts and confirming to IS: 694 complete all as specified and directed | 20 | RUNNING METRE | 150 ₹3,000 | 160 ₹3,200 | 150 ₹3,000 | 157.5 ₹3,150 | 140 ₹2,800 |
Updated dates
Tender Value
₹33.3 L
EMD Value
₹66,600
Closing Date
15 Jan 2026, 6:00 pmClosed
Shri Ayan Saha, IDSE, EE
GE(AF) Phalodi PIN-342301
SPL REPAIR/REPLACEMENT OF E/M HEATING AND COOLING ITEMS AGAINST BER ITEM, PROVN OF SPLIT AC, INTERLOCKING TILES FLOORING, STAINLESS STEEL UTENSIL RACK, FLAME PROOF LIGHT, FIXTURE AND LIGHTING ARRESTER, STEEL LADDER, THREE PHASE AT PHALODI
2025_MES_744376_1
8760/A/E8
Open Tender
Civil Works
180 days
Air Force Station Phalodi
as per tender documents.
7 documents required · 7 mandatory
₹500
GE(AF) Phalodi
₹66,600
Yes
5 Feb 2026
12 Dec 2025
22 Jan 2026
12 Dec 2025
15 Jan 2026
1 Jan 2026
M&L for providing 100mm thick, PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base of floors and pavings etc. complete all as specified and directed.
Supply ,fixing and installation inverter split AC units indoor/outdoor copper condenser , digital display, heavy duty compressor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
S & F copper pipe size 1/4'' size including connected two copper pipe by brazing complete all as specified and directed.
S & F copper pipe size 1/2'' size including connected two copper pipe by braging complete all as specified and directed.
S&F of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed.
S & F in of PVC insulated 3 core copper PVC insulated FRLSH cable of size 4.0 Sqmm, flexible cables, 1100 Volts and confirming to IS: 694 complete all as specified and directed
Supply and fix Air conditioner wall mounted metal bracket heavey duty for outdoor unit of split AC's 1.5/2.0 TR capacity complete all as specified and directed.
M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through in PVC casing caping on wall/roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor shall be measured and paid as one unit length.
M&L for Sub main wiring with 4 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including steel conduit caping with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Four runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC casing caping shall be measured and paid as one unit length.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) 4 pole TPN 40 to 63 amp in the DB complete with connection testing and commissioning.complete all as specified and directed.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 8 way, 230 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc complete all as specified and directed.
Supply ,fixing and installation single phase dual AC controller timer 110 volt with digital display complete all as specified and directed
M&L for Sub main wiring with 2 runs of 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 20mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof or concealed type on wall and one run of 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of PVC conduit of 20mm dia shall be measured and paid as one unit length.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron strip complete all as specified and directed.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
M&L GI tubing light grade 40 mm dia for encasing strip for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or as mounting bracket bend to shape with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works complete all as specified & as directed.
M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x 6 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 20X3 mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40 mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) The unit rate includes for protection pipe and GI strip 20 x 3 mm from top of earth plate up to 7.5 meter above ground level.
S&F Copper strip 20 x 3mm with saddels and fixing screws for roof conductors and down conductors avobe ground ,Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or fixed to wall on insulators or any other indicated situation for loop earthing etc as required 20X3.15mm copper strip complete all as specified and as directed.
Supply and fixing earth value /Type indicator metal sheet post made of MS and sheet ,post height 1.0 Mtr, sheet size (1500 mm X 600 mm X 3 mm) pole including two coat of synthetic enamel(yellow/Red/Black) paint & fixied on PCC (1:2:4) complete all as specified and directed.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces for One light/ Fan Point controlled by one switch complete all as specified & as directed.
All as per item No. 26.00 above but for one 3 pin socket out let 5 Amp on same board complete all as specified and directed.
All as per item No. 26.00 above but for one 3 pin socket out let 5 Amp on independent board complete all as specified and directed.
All as per srl item No. 26.00 above but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated sheathed copper conductor cable FR-LSH multi strand on independent board including provn of 1.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed
S&F switch piano flush type, 6 Amp 240 Volt, AC one way etc complete all as specified and directed.
S&F switch piano flush type, 16 Amp 240 Volt, one way etc complete all as specified and directed.
S&F one socket outlet flush type 3pin 16 Amp, 230 volts AC complete all as specified complete all as specified and directed.
S&F flush type socket outlet 5 Pin 6 Amp, 230 volts AC complete all as specified and directed.
S&F Ceiling fan regulator flush type electronic step type , 230V 450 Watt complete all as specified and as directed.
S&F ceiling rose surface polycarbonate 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F of smart bright series , LED luminaire using LED 20 Watt, 110 lumens/watt with diffuser which ensure uniform distribution and comfort, batten series features latest LEDs and delivers consistent light output, stable colour start extruded aluminium housing, energy efficient, flicker free start inbuilt driver unit, suitable for wall and ceiling mounting using brackets with and including the luminaire testing on completion as per standard specification IEC 60598-2-1/IS : 10322(parts/sec) etc complete all as specified and directed.
S&F LED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed.
M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through in PVC conduit on wall/roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor shall be measured and paid as one unit length.
S&F LT feeder pillar box factor made cubical type dust proof, out door type both side opening of size 100 x 80 x 40 cm of MS sheet 3 mm thick power coated machine pressed front opening with rubber gasket / bedding , locking arrangement with sliding bolt including aluminium bus bar of 400 amps 4 strips mounted on insulators each strip should be munted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of suitable size duly spray painted internally and externally with two coat of synthetic enamel paint over a coat of red oxide primer grouted in PCC 1:2:4 type ‘B’ ( using 20 mm graded stone aggregate complete incoming / outgoing cable provision. with 100A MCCB as Incoming complete all as specified and as directed
S&F sheet metal enclosure MCB distribution board triple pole & neutral 415 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F ON Load change over switch 415V in sheet metal enclosures 4 Pole of capacity 200 Amps Tto 400 Amps complete all as specified and directed.
S&F MCB TPN 63 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed
S&F MCB SPN 63 Amp C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F MCB SP 6 to 32 Amp B curves MCB repturing capacity 10 KA etc complete all as specified
and directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR as shown Complete all as specified and directed.
Supply and installed voltage stabilizer for automatic operation single phase naturaly air cooled indoor type & designed for input variation between 170 to 250 volts with output voltage stabilized at 230 volt with accuracy of +/- 2.5% & of capacity 5.0 KVA complete all as specified and directed.
Supply ,laying, jointing and testing of GI tubing medium grade 20 mm bore with all fittings laid in trenches complete all as specified and directed.
Supply ,laying, jointing and testing of GI tubing medium grade 15 mm bore with all fittings laid in trenches complete all as specified and directed.
S&F Bib taps, CP with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed of size 15mm bore complete all as specified and as directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out for laying underground cable in soft/losse soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for dry tibba sand in trenches for cushioning to under ground cable spreading, levelling, hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
Supplying and laying un reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x150mm x 40mm, laid by dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cable for protection all as specified and directed.
Excavation over area for depth exc 1.5m deep and getting out in any kind of soil complete all as specified and directed.
M&L for Cement concrete type B-2 (1:2:4) using 40 mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed.
KILOGRAM
SQUARE METRE
M&L for Sub main wiring with 2 runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 20mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof or concealed type on wall and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of PVC conduit of 20mm dia shall be measured and paid as one unit length.
M&L for Preparation of new plastered surfaces and applying two coat of cement base paint over a coat of of alkali resistant priming paint complete all as specified and directed.
M&L rendering 10mm thick in CM 1:6 on fair faces of brick or concrete surfaces finished even & smooth w/o using extra cement complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI pipe 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways ,PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work,disposal of suplus spoil to a dstance not exceeding 50mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including dismantling of old earth plate complete all as specified and directed. Note :- (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
Supply and fixed flame proof and weather proof MCB DB SPN 6 Way Enclosure Size 250x250 mm FLP distribution Panel complete , 240 VoltsIncoming : MCB 2P,32 Amp-01 No. , Outgoing : MCB 1P 10 Amp -04 NO with complete internal Busbar & wiring upto terrminal complete all as specified and directed. Note: 1. Flameproof LED light procured by the contractor shall pre tested in accordance with LM 79 by manufacturers for individual Flameproof LED products, in their own laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) or UL or third party laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL)Contractor shall submit documentary evidence obtained from manufacturer of LED light fitting that laboratory in which testing has been carried is accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) along with sample of LED fitting as directed. 2. All fitting should be Mfg date After July 2017 and their guarantee certificate submit to Engineer-in-charge before execution of work.
Surface dressing n. exc 15 cm deep and getting out in soft/loose soil/sand all as specified and directed.
Supplying and fixing,testing the water heater storage type 25 litres, BEE Five star rat
M&L for sand filling under floors including spearding and levelling in layers n exc. 25 cm thick, watering and consolidation complete all as specified and directed .
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80mm thickness, M-40 Grade of cement concrete with grey cement and pigment all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry @ 3 Kg / Sqm complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20 mm thick cement screed bed in CM 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. incl raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Supply and fixing LED light fitting 2 x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. Note: 1. Flameproof LED light procured by the contractor shall pre tested in accordance with LM 79 by manufacturers for individual Flameproof LED products, in their own laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) or UL or third party laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL)Contractor shall submit documentary evidence obtained from manufacturer of LED light fitting that laboratory in which testing has been carried is accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) along with sample of LED fitting as directed. 2. All fitting should be Mfg date After July 2017 and their guarantee certificate submit to Engineer-in-charge before execution of work.
Supply and fixing of Flame proof rotary switch ( Isolator ) rating 16 Amps. Single pole ON /OFF in aluminium alloy LM 6 Construction with one/ 2 nos, 3/4 " ET entries, certified by CMRS , Dhanbad for Group I, IIA, IIB, complete all as specified and directed. Note: 1. Flameproof LED light procured by the contractor shall pre tested in accordance with LM 79 by manufacturers for individual Flameproof LED products, in their own laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) or UL or third party laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL)Contractor shall submit documentary evidence obtained from manufacturer of LED light fitting that laboratory in which testing has been carried is accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) along with sample of LED fitting as directed. 2. All fitting should be Mfg date After July 2017 and their guarantee certificate submit to Engineer-in-charge before execution of work.
Supply and fixing LED light fitting of capacity 30 Watt flame proof weather proof , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete as specified and directed.
Supply and fix flame proof weather proof FLP Exhaust Fans 300 mm sweep, 230 V 50 Hz, 1440 RPM, with all connected accessories, fixed as per manufacturer's instruction and connecting complete all as directed.
PER 1000 NOS
M&L for cable protection cover with sub Class`B` bricks Designation 75 old size laid dry, flat perpendicular across the cable in trenches complete all as directed
M & L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 100 mm bore for crossing the pipe line complete all as specified and directed. Note :- GI pipe shall be measured and paid saperately.
M&L GI tubing light grade 100 mm dia for encasing strip for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or as mounting bracket bend to shape with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works complete all as specified & as directed.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
S & F single pointed air termination aluminium rod 12 mm dia and 300 mm long complete with all fitting arrangement all as specified and directed.
S & F Aluminium strip of size 25 x 3.15 mm fixed on wall/ roof with saddles and fixing on porcelaine insulator & screw etc for earth continuity conductors as continues earth strips from copper rod to test point terminal all as specified and directed.
M&L for test point terminal box made of gunmetal or phosphorus bronze size 75 x 75x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal heads screw including test terminal block of size 150 mm x 150 mm 100 mm made of MS sheet not less than 1.5 mm thick having hinged cover with 2 Nos locking nuts/bolts duly painted with 2 coats of red colour synthetic ename
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
tender.pdf
Tender Documents • 1.26 MB
BOQ_833504.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid