Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.0 L+₹20,456.90 (0.74%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹43.4 L
EMD Value
₹86,860
Closing Date
31 May 2023, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-T-02/2023-24 PROVN OF PARADE CUM ENROLLING SHED AT 1ASC AF AND HARDSTANDING AT DIFFERENT LOCATIONS AT (AF) STN AMBALA UNDER GE (AF) AMBALA
2023_MES_593215_1
GE AF/AMB-T-02/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE AF AMBALA
₹86,860
Yes
6 Jul 2023
4 May 2023
2 Jun 2023
4 May 2023
31 May 2023
18 May 2023
5 May 2023 - 15 May 2023
Amount
M&L for excavation over areas not exceeding 1.5mtr deep and getting out, complete all as specified and directed.
Excavation in trenches, n.exc. 1.5mtr wide and not exceeding 1.5mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan and not exceeding 1.5mtr in depth and getting out in soft/loose soil, complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as specified and directed.
Removal of soil to a distance not exceeding 50mtr and depositing, complete all as specified and directed.
Removing excavated material not exceeding 50mtr and depositing where directed at a level n.exc 1.5mtr above the starting point as in soil, complete all as specified and directed
Returning filling in incl spreading leveling watering and well ramming in layers not exceeding 25cm in thickness, complete all as specified and directed
M&L for hardcore of broken stone or boulder of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L 100mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in sub base, complete all as specified and directed.
Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 80mm thickness, M-40 Grade, complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded machanically crushed stone aggregates) as in coping / bonding of interlocking tiles/ edging complete all as spd and as directed.
M&L for stone kerb of roughly squared stones of size 20cm*30cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush complete all as specified and directed.
M&L 150mm thick PCC (1:2:4) type B2 (using 20mm graded aggregates) as in floor, finished even and smooth without using extra cement etc. complete all as specified and directed.
M&L for cement concrete, 1:4:8 type D2 (using 40mm graded aggregates) in foundations, filling and mass concrete, complete all as specified and directed.
M&L for brick work with bricks old size , straight or curved on plan exceeding 6mtr mean radius, built in cement mortor 1:4, complete all as specified and directed.
M&L for brick work with fly ash bricks old size, straight or curved on plan exceeding 6mtr mean radius , built in cement mortor 1:4, complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4, finished even and smooth without using extra cement, complete all as specified and directed.
M&L preparing of new plastered surface of walls and applying two coats of cement base paint, over chalk whitening complete all as specified and directed.
Material and labour for 75mm thick PCC 1:3:6, type C-1 (using 20mm graded mechanically crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed. Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3mtrs length, 12mm wide. (ii) 50mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume.
M &L Excavating in post holes (or similar holes) each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm etc. complete all as specified and directed.
M&L for PCC (1:3:6 ) type B-2 as in foundations, filling and mass-concrete complete all as specified and directed.
M&L steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and directed.
M&L for painting to steel surfaces of any description, over 10cm in width or girth, not otherwise described, complete all as specified and directed.
S&F Pre painted galvalume aluminum zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality- A , complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding10cm long and 16mm dia of shank complete all as specified and directed.
Material and labour for non skid coloured ceramic tiles, joint free, 7 to 8mm thick, area of each tile exc 0.11sqm and not exc 0.18sqm, joint less, in floor, set in neat cement slurry and pointed with coloured /white cement to match the surface over 15mm thick screed bed in CM 1:4, complete all as specified and directed.
Material and labour for glazed ceramic coloured tiles of size 300x450x7mm thick on vertical surface as in skirting/dado set and jointed in neat cement slurry & pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 on brick / concrete walls complete all as specified and directed
M & L for 25mm thick cement concrete 1:2:4, type B-0 (using 12.5 mm graded aggregates) as in levelling course for laying floor finishes, complete all as specified and directed
S&F GI pipe of 1.5 feet length & 50/75mm dia with cover/lid to prevent logging of water and embeded in hardstanding having an arrangement to install pipe/bamboos within it for pitching of tent complete all as specified and directed by Engr-in-Charge.
E/M PORTION
M & L for surface point wiring complete with 1.5Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 19mm dia ISI marked and conduit accessories fixed concealed in wall with sunken type pressed steel/welded MS terminal boxes made out of 1.6mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings, switches, sockets outlets, regulators etc complete including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :-
One light/bell/fan/exhaust point controlled by one switch 6amp one way, complete all as specified and directed.
One 3 pin switch socket combination 6amp on the independent board, complete all as specified and directed.
One 3 pin switch socket combination on same board with other switches, complete all as specified and directed.
All as per srl item No. 36.00 here-in-before but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed.
M&L switch piano flush type single pole, one way 6amp, complete all as specified and directed.
M&L switch piano flush type single pole, one way 15 amp, complete all as specified and directed.
M&L socket outlet 2 in 1, 3 pin 5 A flush type, complete all as specified and directed.
M&L socket outlet 2 in 1, 3 pin 5 A and 15 A flush type, complete all as specified and directed.
S&F ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed.
Supply and fixing LED tube light fitting 1x18 watt, 230 volts in commercial channel with powder coated CRCA sheet housing with opal diffuser for LED with LED tubelight with high efficient LED in aluminium housing with clear & milky diffuser connecting with twin core twisted flexible copper conductor cable with suitable size rod complete with all accessories all as specified and directed. Note : The LED rod should Have PF >0.9 ,input voltage 90-300V, IP-65 , LM 80 stranded luminaries efficiency 100 lumen/watt, complete all as specified and directed.
S&F energy efficient LED flood light fitting, 70 W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.95, minimum 50000 burning hours, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers, with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and as directed.
S&F MCB SPN 40 Amp, with complete cover with sheet metal enclosure DB 2 Way with fixing arrangement on wall with the help of suitable fastner on wall complete all as specified and directed
Supply and fixing sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200Amp rated bus bar including making the surface good complete all as specified and directed.
S&F in MCBs SPN B curve 40Amp 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed.
S&F in MCBs 5 to 32 amp SP B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0mm dia upto 7.5mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil, PCC 1:3:6, type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete 1:2:4, type B1, reinforced with welded steel wire fabric or XPM,(weight not less than 4Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia, light grade,7.5mtr long for protection of earth lead upto test point etc all as specified and as directed.
Supply and fixing ceiling fan BLDC complete with electronic type regulator and accessories 230V, 1200mm sweep 5 star rated with down rod upto 4 feet length alongwtih all accessories complete all as specified and directed.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 10 Sqmm 2 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified and directed.
M&L river fine sand as in sand cushioning to under and above the under ground cable including punning down the sand complete all as specified and directed.
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed
Make bore to road/cement path/hard standing for providing GI pipe 50 to 80mm both end socketed for passing armoured cable including making good the disturbed surface complete all as specified and directed.
Supply and fix GI tubing 40mm bore ligth grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position complete all as specified and directed.
Supply & fixing Thermoplastic cable junction box with 02 Nos PVC gland, weather proof with IP 65/67 protection for outdoor installation (with knock outs for cable entry of size 355 x 255 x122 mm hinged type with 2 Nos Aluminium bus bar of size 25mmX6mm and 4 Nos terminals with nut and bolt mounted on bus bars and MCB 10 Amp rating 01 Nos and include connection with existing cable and duly fixed with MS clamp made out of FI 40 x 3 mm thick with nut & bolt complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregates) as in bocks to hold GI extension pipe for Air termination rod complete including necessary use and waste of form work required, complete all as specified and directed.
M & L for Taking out of street light pole and leveling of ground after removal of light including filling of ditches and removing of debris from the site and refixing the same pole and refixijng street light, complete all as specified and directed.
Swami Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .