Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.5 LAccepted-AOC | 1 | Accepted-AOC Lowest Bidder | |
| 2 | 2₹19.5 L+₹25,441 (1.32%)Rejected-Finance | 2 | Rejected-Finance Not Lowest Bidder | |
| 3 | 3₹20.6 L+₹1.4 L (7.03%)Rejected-Finance H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | 3 | Rejected-Finance Not Lowest Bidder | |
| 4 | 4₹20.6 L+₹1.4 L (7.32%)Rejected-Finance | 4 | Rejected-Finance Not Lowest Bidder | |
| 5 | 5₹21.5 L+₹2.3 L (11.9%)Rejected-Finance | 5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
4 Mar 2020, 6:00 pmClosed
Garrison Engineer Kota
Opp Circuit House, Station Road, Kota - 324001
SPECIAL REPAIR TO BLOCK NOS P-221 (04 QTRS) AND P-306 (04 QTRS) IN GTC LINE AT MILITARY STATION KOTA
2020_MES_322349_1
8419/E8
Open Tender
Civil Works
Item Rate
243 days
Kota
Class D Category a(i)
8 documents required · 8 mandatory
₹500
GE Kota
₹58,000
Yes
18 Mar 2020
7 Feb 2020
6 Mar 2020
7 Feb 2020
4 Mar 2020
21 Feb 2020
8 Feb 2020 - 14 Feb 2020
Amount
Demolition/Dismantling of existing normal roof treatment comprising of PCC padding with or without wire mesh from RCC roof slab, complete all as specified and directed.
M&L brushing neat cement slurry with 3.00 kg cement per Sqm, complete all as specified and directed.
M&L for PCC 1:2:4 mix type B-0 (Using 12.5 mm graded stone agg) for roof padding, leveling course to receive floor finishes etc, complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of RCC roof slab in CM 1:4 duly mixed with liquid water proofing compound, finishing surfaces even and smooth without using extra cement, complete all as specified and directed.
Supply only liquid water proofing compound Dr Fixit LW+ or equivalent as approved by the GE, complete all as specified and directed.
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish, reinforced with non-woven polyester mat with a thermo fusable finish, laid over compatible bitumen primer @ 0.40 Kg/Sqm, torching overlaps with propane or butane gas torch, with an overlap of 75mm at the sides and 100mm at the ends and sealing, complete all as per manufacturer’s instructions, specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm.
Item 6.00 Contd……. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen. (v) Cost of these factors shall be deemed included in the unit rates.
M&L for cleaning of walls and floor of sunken portions including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish, reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer @ of 0.40 Kg/Sqm, torching overlaps with propane or butane gas torch, with an overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer @ 1.20 Kg/Sqm, complete all as per manufacturer’s instructions, specified and directed. Note: (i) The waterproofing treatment shall be got carried out through the manufacturer or their authorized applicators only.
M&L for providing 40 mm bore GI medium grade pipe as spout in sunken floor including cutting holes in brick walls, built in cement mortar and making good the dismantled portion in PCC 1:2:4 type B-1 with using 20 mm graded stone aggregate and finishing the same to match with external surface, complete all as specified and directed.
Taking down cement plaster of any description and thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for 15 mm thick rendering on other than fair faces of brick/concrete surfaces in two layers, consisting of 10 mm thick in CM 1:6 and over that 5 mm thick in Cm 1:4 using water proofing compound as per manufacturer's instructions, finishing surfaces even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Supply only approved integral water proofing compound (Powder), complete all as specified and directed.
M&L for applying two coats of cement based paint on newly previously untreated plastered or unplastered surfaces of walls including preparation of surfaces, complete all as specified and directed.
M&L for preparing new previously untreated plastered surfaces of walls and applying 1 to 1.50 mm thick layer of wall care putty and over it applying two coats of modified exterior acrylic emulsion paint over a coat of primer, complete all as specified and directed. (Make: Asian paints - Apex Ultima, ICI Dulux - Weather Shield Max, Berger - Weather Coat Long Life, Acro Paints - Acroguard 3X)
Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15 cm thickness (below or above GL), complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise provided for, complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 75 mm thick as in sub base, finishing the surface even & rough to receive topping layer, complete all as specified and directed.
M&L for 25 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in flooring finished even and fair without using extra cement complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 17 to 22 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, laid over and including 20 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for jointfree non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4, complete all as specified and directed.
M&L for machine cut kota stone slab as in skirting, dado, risers etc, 17 to 22 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, laid over and including 10 mm thick CM 1:4 backing, complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors etc, laid, bedded and pointed in any mortar, complete all as specified and directed.
M&L polished baroda green slabs, 18-20 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of marble stone including grinding and polishing complete, laid over and including 15 mm thick screed in CM 1:6, complete all as specified and directed.
M&L for preparing previously untreated plastered surfaces of walls and applying 1 to 1.5 mm thick Wall care putty as per manufacturer's instructions and over it applying two coats of distemper oil emulsion over a coat of primer, complete all as specified and directed.
Taking up or down 15 mm dia steel tubing and connection including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down 20 mm dia steel tubing and connection including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down 25 mm dia steel tubing and connection including cleaning for refixing or removal to store, complete all as specified and directed.
S&F 15 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors complete all as specified and directed.
S&F 20 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors complete all as specified and directed.
S&F 25 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors complete all as specified and directed.
Refixing old steel tubing (With and including new GI fittings) in new or old position (Wall, Ceiling, floor etc) of 15 mm dia pipe complete all as specified and directed.
Refixing old steel tubing (With and including new GI fittings) in new or old position (Wall, Ceiling, floor etc) of 20 mm dia pipe complete all as specified and directed.
Refixing old steel tubing (With and including new GI fittings) in new or old position (Wall, Ceiling, floor etc) of 20 mm dia pipe complete all as specified and directed.
S&F 500 Ltrs capacity rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position incl Dismantaling existing water tank of any type, complete all as specified and directed.
S&F 20 mm dia ball brass valve, high pressure with polythene float and fly nut, screwed down for iron pipe, complete all as specified and directed.
S&F 20 mm dia stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, medium weight, cold rolled and fixed with screws all as specified and directed.
S&F Wire netting of galvanised steel wire 2.00 mm dia fixed with tinned tacks of wire staples, size of mesh 20 mm, complete all as specified and directed.
S&F 100 mm Hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest incl providing lime concrete bedding and connecting to flusing cistern complete all as specified and directed.
S&F PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action top push type with inlet ball valve and float including taking down existing, complete all as specified and directed.
S&F in repair swivel shower rose of CP brass, 75 mm dia, for fixing with 15 mm pipe with shower arm 15 mm size, 195 mm long with bend of 45 degree with flange of CP brass, complete all as specified and directed.
S&F 'D' type towel rail 60 cm long, stainless steel, fancy type, 20 mm dia complete fixed with steel screws complete all as specified and directed.
S&F in repairs stainless steel utensil plate rack of size 900x1000x200 mm, made of 0.60 mm thick stainless steel sheet and fixed in position, design and pattern as approved by the GE, complete all as specified and directed.
S&F in repair sink with draining board made of stainless steel 1mm thick with plugs, washers and waste coupling, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets of suitable angle iron, 32 mm dia superior quality PVC waste pipe and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S&F in repair vitreous china wash hand basin flat back 550 x 400 mm excluding tap but including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, PVC waste pipe with connector, brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed.
S&F pillar taps, cast copper alloy, with capston heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers, complete all as specified and directed.
S&F in repair 15 mm bore bib taps, screwed down, high pressure with crutch or capstan head, chromium plated brass, fancy type, screwed for iron pipe or for unions, complete all as specified and directed.
S&F in repairs stop valves, fancy type, chromium plated brass with long shank and cup (Concealed type), screwed down, high pressure, both ends screwed to iron pipe or for union, dia of pipe 15 mm, complete all as specified and directed.
S&F in repair angle valve, fancy type, chromium plated brass, screwed down, high pressure, screwed one end to iron pipe or union of dia 15 mm, complete all as specified and directed.
S&F in repair bib taps with aerator, cast copper alloy, fancy type, chromium plated, long body with capstan head, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket, complete all as specified and directed. (Make Essco, Cat part No. 512)
S&F in repair stainless steel tubular curtain rods, 25 mm dia, with fixing brackets and one pair of decorative end caps etc, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames glazed with putty or fixed with beads complete all as specified and directed.
M&L for 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
Dismantling cast iron or reinforced concrete concrete drain pipes 75 mm bore, jointed in CM and taking out from trenches if required, complete all as specified and directed.
Dismantling cast iron or reinforced concrete concrete drain pipes 100 mm bore, jointed in CM and taking out from trenches if required, complete all as specified and directed.
S&F 75 mm dia cast iron soil, waste & vent pipes, with or without ears, in any length, with cement joints, laid in trenches or under floors complete all as specified and directed.
S&F 100 mm dia cast iron soil, waste & vent pipes, with or without ears, in any length, with cement joints, laid in trenches or under floors complete all as specified and directed.
S&F 75 mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F 100 mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F 75 mm bore CI branch pieces, single (equal or unequal) ordinary or inverted or with parallel branches, with oval access door, complete all as specified and directed.
S&F 100 mm bore CI branch pieces, single (equal or unequal) ordinary or inverted or with parallel branches, with oval access door, complete all as specified and directed.
S&F stack clamps made out of 50x5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, bore of pipe 100 mm, complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm and not exc 2 Sqm each complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed.
S&F mild steel framed work as in grills, grating etc. with end of bars shouldered and/or riveted, or forged into spikes: framed guard bars: barred iron doors: ladders: frame balusters: walk ways: railing: frame work of water tanks and similar works conforming to Fe-290 Grade-E-165, complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of zinc chromate primer complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars including one shop coat of zinc chromate primer complete all as specified and directed.
S&F steel windows or ventilators with top hung shutters including box type friction hinges, steel handle and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of zinc chromate primer complete all as specified and directed.
S&F in repair 125 mm long MS handle of standard pattern for steel window including necessary nut, bolt and washer, compete all as specified and directed.
S&F in repair 300 mm long MS peg stay of standard pattern for steel windows including necessary nut, bolts and washers, complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and directed.
M&L for 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
M&L for preparing new steel surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chromate primer, complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Taking down chowkhat or frames not exc 1.50 Sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhat or frames exc 1.50 Sqm and not exc 4.00 Sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed.
M&L for 25 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and directed.
S&F 35mm thick factory made IInd Class Hard wood (Hollock) panelled door shutters single panel with lock rail and panel of 9mm B.W.P. marine grade plywood bonded with high quality liquid phenol formaldehyde synthetic resin adhesive conforming to IS-710 or 12mm thick particle board veneered with commercial veneering on both faces. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
S&F 35mm thick factory made IInd Class Hard wood (Hollock) glazed and skeleton, open rebated, prepared to receive glass, gauge etc, without sash bars, edges of framin plain, chamfered and rounded, fitted with cut and mitered beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
M&L mild steel door frames made of angle iron with and including hold fasts and FI thresh hold etc, and fixed to openings, conforming to Fe-290 Gde E-165, complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing, complete all as specified and directed.
S&F 150 mm size aluminium anodised barrel tower bolts of extruded section, fixed to door shutters with screws, complete all as specified and directed.
S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as specified and directed.
S&F aluminium handles, cast type, anodised 125 mm size, fixed to shutters with screws, complete all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flap (when open) 40 mm all as specified and directed.
S&F 300 mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor, overall length of cover plate 140 mm, complete all as specified and directed.
S&F 18/19 mm thick block boards, grade 1 quality, exterior grade, commercial type, fixed with screws to timber frame work, complete all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces, exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M & L for preparation of old painted surfaces of wood or wood based materials of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work/concrete surfaces in CM 1:6 finishing surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for 10 mm thick rendering on fair faces of brick work/concrete surfaces of ceiling in CM 1:4 finishing surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of old previously treated plastered/unplastered surfaces of walls and applying two coats of distemper oil emulsion, complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of newly palstered surface, complete all as specified and directed.
M&L for preparation of old previously treated plastered/unplastered surfaces of ceiling and applying one coat of white wash, complete all as specified and directed.
Demolition of brick work/stone boulder masonry, built in CM incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
M&L walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6, complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 100 mm thick as in sub base, finishing the surface fair & even, complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size made with grey cement and pigment, confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, laid over and including 25 mm thick sand cushion, complete all as specified and directed.
Cutting holes into or through brick/stone masonry walls exceeding half brick but not exceeding one brick thick, built in cement mortor and making good in cement mortor (1:3) or cement concrete (1:2:4) type B1 as required, complete all as specified and directed.
S&F glass shelf assembly of 6 mm thick glass, 12 cm wide and 60 cm long and CP guards of approved quality and fixed to wall with PVC rawl plugs and stainless steel screws, complete all as specified and directed.
S&F soap dish made of stainless steel, fixed to wall with PVC rawl plugs and stainless steel screws, complete all as specified and directed.
Demolition and breaking up drain pipes and fittings, salt glazed ware, AC, PVC or RCC, internal dia of pipe 150 mm, complete all as specified and directed.
M&L for 150 mm dia salt glazed stoneware drain pipes, laid in trenches and jointed in cement sand slurry in 1:1, complete all as specified and directed.
S&F in repairs PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and laid in trenches/floor, complete all as specified and directed.
M&L PCC 1:4:8, type D-2 using 40 mm graded stone aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of 150 mm dia pipe, after they are laid and tested, complete all as specified and directed.
M/L for 50mm thick rough dressed stone slabs for manhole covers n.exc 2 mtr in length, punched dressed on face and along exposed edges, self faced on other side and sets and pointed in cement mortar 1:4 complete all as specified and directed.
M&L Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 40mm graded stone aggregate), 75 mm thick as in plinth protection/Path/PCC paving etc including finishing the surface even & smooth without using extra cement, with and including all necessary formwork to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three parts of fine sand by weight), complete all as specified & directed.
M&L for providing water proofing treatment to RCC roof/chajja surface, edges, soffits etc in following stages: - i) Preparation of surfaces by cleaning of dust, washing with water etc and filling cracks with approved crack filler compound. ii) Applying 5 mm thick rendering in CM 1:3 and finishing the surfaces even and smooth without using extra cement. iii) Applying three coats of heavy duty elastic & resilient acrylic polymer, reinforced with micro fibers & fungicidal @ 0.50 liters per Sqm in each coat and dried for 6-8 hours after each coat with and including woven glass fiber mesh 2.5mm x 2.5mm put between first and second coat.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surface, complete all as specified and directed.
Disconnecting and taking down carefully ceiling fan/exhaust fan and refixing after cleaning, oiling/greasing and connecting with suitable size copper conductor cable, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface including making good disturbed surface all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps.
One 5 Pin, 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch.
One 5 Pin, 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 Amp switch.
One light point controlled by two, two way 5/6 Amp switches.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including making good disturbed surface, complete all as directed and specified.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
Supply and fixing switch socket combination, 5/6 and 15/16 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing switch socket combination, 5/6 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing socket outlet, 5/6 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed.
S&F switch bell push, 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
S&F bell electronic, ding dong type, 230 volts, single pole, ISI marked, complete all as specified & directed.
S&F LED Tube light fittings, batten type with bipin holders, powder coated steel with retrofit 20 watt LED tube, internally prewired, complete all as specified and directed.
S&F PVC/polycarbonate lamp holder, angular/batten type with back plate, complete all as specified & directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed. (Make - Legrand/L&T/Siemens)
S&F MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed. (Make - Legrand/L&T/Siemens)
S&F MCB, 63 Amps, Triple Pole & Neutral, 415 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed. (Make - Legrand/L&T/Siemens)
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 415 Volts TPN with 6 ways, Double door, complete all as specified and directed. (Make - Legrand/L&T/Siemens)
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 8 ways, Double door, complete all as specified and directed. (Make - Legrand/L&T/Siemens) Note for item Nos 134 & 135 - (1) The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 6 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor complete all as specified & as directed. NOTE:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit. Cutting chases in walls shall not be measured and paid separately.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth lead strip of size 25mm x 4 mm by means of bolts, buts, check nuts and washers of galvanized iron on steel including 40 mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI strip of size 25 mm x 3 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 5 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire/strip and earth strip upto 7.5 m. Any variation below or above shall be measured and paid for separately under relevant item of this Sch ‘A’.
S&F LED street light fitting, 36 watt, pressure die cast aluminium housing with IP 66 deg of protection, complete with 1.20 m long street light bracket made of 40 mm bore GI light grade tubing including necessary clamps, nuts, bolts, washers etc, complete all as specified and directed. Make: C&S Cat Ref No. LTESSE36WLED or equivalent in Philips/Surya/Bajaj.
S&F Exhaust fan of size 300mm sweep, 1400 RPM, metal body, complete with condenser and mounting from and regulator including providing/cutting the round hole of required size in the wall finishing the same supply and grouting the ragged bolt in wall, fixing the frame and exhaust fan including supply and fixing the louver shutter with frame on the exhaust side (outer surface of the wall) and connecting PVC insulated twisted twin core 23/0.0076 copper conductor flexible PVC insulated cable of required length from connector/ceiling rose to fan motor and engraving and painting with black synthetic enamelled paint MES number upto 2.5 cm high including testing and commisioning, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 175x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 200x150 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 250x200 mm and 50 mm deep, complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cables/pipes and foundation etc, complete all as specified and directed.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.
Removing excavated soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.
S&F LT 1100 volts grade UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 4 core 16 Sqmm, laid in trenches/ducts, fixed on wall/inside panel or drawn through pipe, complete all as specified and directed.
M&L dry clean Sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. (Depth of sand shall be measured after punning).
M&L for pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), class 10, laid dry and flat adjoining each other over sand cushion in trenches as protection to UG cable, complete all as specified and directed.
M&L 40 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
SINGH ENTERPRISES
Aditya Enterprises
L P Singh and Co.
Ganesh Contruction
S.S Enterprises
ANNAPURNA ENTERPRISES
TARKESHWAR DASS CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .