Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAdmitted-Finance | ₹39.4 L | L1 | Admitted-Finance |
| 2 | L2₹41.9 L+₹2.5 L (6.32%)Admitted-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹41.9 L+₹2.5 L (6.32%) | L2 | Admitted-Finance |
| 3 | L3₹42.7 L+₹3.3 L (8.41%)Admitted-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹42.7 L+₹3.3 L (8.41%) | L3 | Admitted-Finance |
| 4 | L4₹46.4 L+₹7.0 L (17.8%)Admitted-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹46.4 L+₹7.0 L (17.8%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Unenlisted bidder and lacks with regard to work experience of similar nature of work and other requisite documents not as per Para 1.4 and 1.5 of MoC 2020. |
| Sl No | Description | Qty | Unit | M/S Sonu Traders L2 | sanjeev enterprises L3 | Esha Engineers L4 | M/S LADPURIA ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for servicing /preventive maintenance of DG set up to the time of 6 Month of capacity 15 KVA to 30KVA at site comprising of the following drain out used engine oil by opening the oil chamber ,cleaning the chamber throughly, pouring the new engine oil,Pouring the new radiator Coolant, refixing the chamber cover with new gasket , replacement of Diesel Filter ,Oil Filter, Air Filter, cleaning the diesel tank, clean radiator fins , check rubber seal and hose pipes replace if found defective , check speed governer for proper functioning and lubricating linkages,checks functioning of engine protection unit , Check and repair of any leakage etc.and replacement of small minor items such as nut, bolts, washers, etc are included in quoted rates of sch A' . The above checks are strictly followed in the duration of two month interval. Various checks to be followed are:- (a) Checking of engine oil level. (b) Checking of oil bath cleaner oil level. (c) Drain sediments from fuel tank. (d) Checking of pre-cleaner dust pan (e) Checking of air cleaner restriction. (f) Checking of coolant level (g) Record oil pressure (h) Checking/tightening of all nuts-bolts of engine and alternator (j) Checking of AVM pads (k) Checking of diaphragm coupling (l) Checking of tappet clearance (m) clean fuel tank breather (n) Clean crank case breather (o) Checking of air piping (p) cleaning of oil bath air cleaner tray screen (q) Check/adjust belts (r) checking battery voltage, water level and apply jelly on terminals (s) Checking fan hub/air blower hub and water pump (t) Cleaning turbo-charger (u) Tighten manifold nuts of cops screws (v) Cleaning of electrical connections with CTC solutions (w) Checking of safety controls (x) Cleaning of engine. (y) Replacement of complete engine oil with new one Note : (i) Preventive maintenance ( Checking ) should be done on every two Months. (ii) Spare Parts,Filters,Engine oil, Coolent which ever is used shall be measured and Paid Separately. | 4 | Each job | 3,500 ₹14,000 | 1,000 ₹4,000 Lowest | 1,500 ₹6,000 | 3,500 ₹14,000 |
| 2.00 | FUEL FILTER for 10KVA To 30KVA | 8 | Each | 400 ₹3,200 Lowest | 400 ₹3,200 Lowest | 500 ₹4,000 | 1,000 ₹8,000 |
| 3.00 | OIL FILTER for 10KVA To 30KVA | 4 | Each | 400 ₹1,600 Lowest | 500 ₹2,000 | 500 ₹2,000 | 1,000 ₹4,000 |
| 4.00 | AIR FILTER for 10KVA To 30KVA | 4 | Each | 500 ₹2,000 Lowest | 650 ₹2,600 | 600 ₹2,400 | 1,000 ₹4,000 |
| 5.00 | All as per Srl item No.1.00 here-in-above but carried out against 50KVA to 82.5KVA capacity DG Set complete all as specified and directed. | 11 | Each job | 4,500 ₹49,500 | 1,500 ₹16,500 | 800 ₹8,800 Lowest | 3,500 ₹38,500 |
| 6.00 | FUEL FILTER for 50KVA To 82.5KVA | 22 | Each | 500 ₹11,000 | 400 ₹8,800 Lowest | 450 ₹9,900 | 1,500 ₹33,000 |
| 7.00 | OIL FILTER for 50KVA To 82.5KVA | 11 | Each | 500 ₹5,500 Lowest | 500 ₹5,500 Lowest | 500 ₹5,500 Lowest | 1,500 ₹16,500 |
| 8.00 | AIR FILTER for 50KVA To 82.5KVA (INNER & OUTER) | 11 | Each Set | 800 ₹8,800 Lowest | 1,500 ₹16,500 | 800 ₹8,800 Lowest | 1,500 ₹16,500 |
| 9.00 | All as per Srl item No.1.00 here-in-above but carried out against 100KVA to 125KVA capacity DG Set complete all as specified and directed. | 8 | Each job | 5,000 ₹40,000 | 1,600 ₹12,800 Lowest | 1,800 ₹14,400 | 4,000 ₹32,000 |
| 10.00 | FUEL FILTER for 100KVA To 125 KVA | 16 | Each | 650 ₹10,400 | 450 ₹7,200 Lowest | 500 ₹8,000 | 2,500 ₹40,000 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
18 Aug 2026, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
REPAIR/MAINT/SERVICING OF AMF PANEL, DG SETS, CHANGEOVER SWITCHES, EQUIPMENT EARTHING AND OTHER CONNECTED ALLIED ITEMS AT AF STN AMBALA UNDER GE (AF) AMBALA
2026_MES_779984_1
GE AF/AMB-T-25/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹99,000
Yes
3 Sept 2026
21 Jul 2026
20 Aug 2026
21 Jul 2026
18 Aug 2026
4 Aug 2026
22 Jul 2026 - 28 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for servicing /preventive maintenance of DG set up to the time of 6 Month of capacity 15 KVA to 30KVA at site comprising of the following drain out used engine oil by opening the oil chamber ,cleaning the chamber throughly, pouring the new engine oil,Pouring the new radiator Coolant, refixing the chamber cover with new gasket , replacement of Diesel Filter ,Oil Filter, Air Filter, cleaning the diesel tank, clean radiator fins , check rubber seal and hose pipes replace if found defective , check speed governer for proper functioning and lubricating linkages,checks functioning of engine protection unit , Check and repair of any leakage etc.and replacement of small minor items such as nut, bolts, washers, etc are included in quoted rates of sch A' . The above checks are strictly followed in the duration of two month interval. Various checks to be followed are:- (a) Checking of engine oil level. (b) Checking of oil bath cleaner oil level. (c) Drain sediments from fuel tank. (d) Checking of pre-cleaner dust pan (e) Checking of air cleaner restriction. (f) Checking of coolant level (g) Record oil pressure (h) Checking/tightening of all nuts-bolts of engine and alternator (j) Checking of AVM pads (k) Checking of diaphragm coupling (l) Checking of tappet clearance (m) clean fuel tank breather (n) Clean crank case breather (o) Checking of air piping (p) cleaning of oil bath air cleaner tray screen (q) Check/adjust belts (r) checking battery voltage, water level and apply jelly on terminals (s) Checking fan hub/air blower hub and water pump (t) Cleaning turbo-charger (u) Tighten manifold nuts of cops screws (v) Cleaning of electrical connections with CTC solutions (w) Checking of safety controls (x) Cleaning of engine. (y) Replacement of complete engine oil with new one Note : (i) Preventive maintenance ( Checking ) should be done on every two Months. (ii) Spare Parts,Filters,Engine oil, Coolent which ever is used shall be measured and Paid Separately. | 4 | Each job | - | - |
| 2 | FUEL FILTER for 10KVA To 30KVA | 8 | Each | - | - |
| 3 | OIL FILTER for 10KVA To 30KVA | 4 | Each | 1 | ₹4 |
| 4 | AIR FILTER for 10KVA To 30KVA | 4 | Each | 1 | ₹4 |
| 5 | All as per Srl item No.1.00 here-in-above but carried out against 50KVA to 82.5KVA capacity DG Set complete all as specified and directed. | 11 | Each job | 10 | ₹110 |
| 6 | FUEL FILTER for 50KVA To 82.5KVA | 22 | Each | 1 | ₹22 |
| 7 | OIL FILTER for 50KVA To 82.5KVA | 11 | Each | 1 | ₹11 |
| 8 | AIR FILTER for 50KVA To 82.5KVA (INNER & OUTER) | 11 | Each Set | 1 | ₹11 |
| 9 | All as per Srl item No.1.00 here-in-above but carried out against 100KVA to 125KVA capacity DG Set complete all as specified and directed. | 8 | Each job | - | - |
| 10 | FUEL FILTER for 100KVA To 125 KVA | 16 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
25TenderPages.pdf
Tender Documents • 0.78 MB
BOQ_873652.xls
BOQ • 0.47 MB
25Amendmentdate.pdf
PDF • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .