Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical technically qualified |
| 2 | Accepted-Technical C 585 BASEMENT DEFENCE COLONY NEW DELHI 110024 | NEW DELHI | NEW DELHI | DELHI | 110024 | Accepted-Technical technically qualified |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹35.1 Cr
EMD Value
₹70.1 L
Closing Date
5 May 2026, 11:00 amClosed
Alok Singh
Infra-II (Public Health)
DESIGN AND CONSTRUCTION OF 1 NO. RANNEY WELL AT MACHHROLA, 1 NO. RANNEY WELL AND 1 NO. MBS AT JAJJAL AT THE BANK OF YAMUNA RIVER AND ALL OTHER CONTINGENT WORK THERETO WITH 3-MONTHS SUCCESSFUL TRIAL RUN, AND THEREAFTER 6 YEARS DEFECT LIABILITY-CUM-MA
2026_HRY_513508_1
2026AEDBC7D9 9BC0 45B0 A946 1E7DDAD755F52247005
Open Tender
Civil Works
Works
760 days
Sonepat
2 documents required · 2 mandatory
₹20,000
₹70.1 L
Yes
16 Jun 2026
8 Apr 2026
5 May 2026
8 Apr 2026
5 May 2026
8 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | (i) Designing, P and F, commissioning and testing of vacuum- operated automatic switchover gas chlorination system with 1 Working Chlorinator plus 1 Standby Chlorinator compatible with the existing gas chlorination system with three months trial run and one year defect liability period.
(ii) Designing, P and F, commissioning and testing of Chlorine gas dry scrubber consisting of support structures, ductwork of scrubber, blower, dry scrubbing tank, dry scrubbing media, necessary piping, motors, controls, exhaust stack and essential accessories with three months trial run and one year defect liability period. PandF of Prefab Porta Cabin of size 1.83 m. X 1.83 m. and height 2.3 m. with one side slope design with 50 mm PUF wall panels with Pre painted galvanized sheet and 20/60 mm corrugated PUF roof panels with Pre painted galvanized sheet with door, windows etc. complete in all respect.
(iii) Designing, Pand F, commissioning and testing of Auto-shut off valve with three months trial run and one year defect liability period.
(iv) P and F of Dual gas cylinder duly certified and approved by BIS and by explosive department of Govt. of India, Nagpur of 100 kg capacity cylinder As per IS 3196 part –IV.
(v) Providing, fixing, installation, commissioning and testing of chlorine leak detector with alarm/hooter. (As per Technical specifications of gaseous chlorination system as per letter of EIC, PHED, Pkl. Memo No. 23070-23142-PHE/Mont. dated 28/02/2024 (copy attached).
` | - | Job | - | - |
| 2 | HT Metering Panel: Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG)
a). VCB, 11KV, 630Amp, 50KA.
b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s.
c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2.
d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays.
e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above.
f). Master trip relay -2 no’s.
g). Indicator type Annunciator panel with buzzer.
h). Digital Volt Meter- 0-11 KV.
i). Digital Amp Meter- 0-100 Amp.
j). RYB/ Trip/Closing/Spring charged indicator lamp.
k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay.
l). TNC Switch for Operation.
m). Multifunction Meter EM6400NG.
n). TCS Relay for Safe
` | - | Job | - | - |
| 3 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts
including labor, tranportaion ets up to the site. 300 mm nominal diameter | - | NO. | - | - |
| 4 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid
Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble
lugs etc for motors as per entire satisfaction of Engineer-in charge complete in all respect. Make:Finolex / Havells / RR Cables. (150 Sqmm size) | - | Metre | - | - |
| 5 | NS Item -LT CABLE ALLUMINIUM: Supply, erection, testing
and commissioning of IS marked 3.5 core Cables, Solid
Aluminum conductor up to 10sqmm and balance stranded
conductor, XLPE Insulated, cores laid up, PVC Inner
sheathed, Armoured (Aluminium wire for single core up to
70sqmm and balance Aluminium strip, Glavanised wire for
cables up to2x10sqmm, 3x10sqmm, 4x6sqmm and balance all
galvanized steel strip) extruded PVC type ST2 Outer
sheathed, 650/1100V grade as per IS7098 (Part-1) 1988 with
up to date amendments along with all accessories complete in
all respect. Make: Finolex / Havells / RR Cables. (300 Sqmm
size). | - | Metre | - | - |
| 6 | Cloud based software comprising of Middleware,
Database and Front-end web interface through suitable
Dashboards, Aggregation screens and GIS assisted drill-down
from macro to micro to be provided. Application data hosting
and maintenance for Five years included in scope. Cloud
servicesof Ministry of Electronics and Information Technology
(Meity), Government of India empaneled cloud service
providers shall be taken like Microsoft, Amazon, Google,
BSNL etc. Cloud service provider must adhere the security
standards and guidelines issued by Meity from time-to-time.
As the data belongs to the State Government of Haryana,
therefore the application and data hosted on Cloud must be
kept and stored in data centres located in India only. Any
change in application requirement or infrastructure shall be
borne by the Implementation agency. Implementation agency
shall carry out the Application Security Audit from a Certified
Auditor (CA). Application and data shall be kept confidential
and only the authorized users shall have the access to it.
Implementation Agency shall be responsible for any data theft
or data leakages.` | - | NO. | - | - |
| 7 | NS Item -`Online Chlorine Sensor : Supply, Installation,
Testing, Commissioning with five year maintenance of Online
Chlorine Sensor.
(For MBS) | - | NO. | - | - |
| 8 | NS Item -`RTU: Functional Integration at RTU-cum-Gateway
for Motorized Control Valve in Pump Control Panel
(For MBS)` | - | NO. | - | - |
| 9 | NS Item -`Electromagnetic Flowmeter: Supply, Installation,
testing, Commissioning five year maintenance,
Electromagnetic Flowmeter along with its installation complete
in all respect as per specifications.
Size as per site requirement.(IP-68), RS-485 ModBus.
Line size 400 mm, installed at pump End / Source.
(For MBS) | - | NO. | - | - |
| 10 | NS Item -`Automation Panel: `Automation Panel for
integration with VFD with Pump Control Panel, along with
Auto/Manual Selection Switch as well as On/Off push button
to be provided. Manual selection between pump 1 and pump 2
depending on which to be operated and which to be stand by
to be provided, along with all relay interlocks and provision of
operation of pumps through potential free/open collector
digital outputs of RTU-cum-Gateway device.
The panel will contain RTU-cum-Gateway with necessary I/Os
and edge controller Motorized control valve in Local / Remote
or Auto/ Manual modes of operation in tandem with Cloud
Scheduler or Level sensor-based functions.
Panel will contain SMPS with rechargeable battery
backup (min. 24 hrs.) along with facility to connect all field
instruments with 24 VDC power supply. `
(For MBS | - | NO. | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
BOQ_592328.xls
BOQ • 0.37 MB
4GAJHOZ157896.pdf
Additional Documents • 0.18 MB
timeextension.pdf
PDF • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .