Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Qualified |
| 2 | Accepted-Technical | Accepted-Technical Qualified |
| 3 | Accepted-Technical 140 RAJDANGA CHAKRABORTY PARA 1ST FLOOR KASBA KOLKATA 700107 | KOLKATA | KOLKATA | WEST BENGAL | 700107 | Accepted-Technical Qualified |
Tender Value
Refer Docs
Closing Date
20 Aug 2026, 2:00 pmClosed
SE, PMU, WBDWSIP, PHE DTE
Utility Building, 1st Floor, (Premises No.-09/1-0024) AA-IA, (Tank No.-3), New Town Kolkata-700 156
Smart Water Management at OHRs and Data Display for other Water Supply Locations
2026_PHED_1031568_1
IFB NO.-01/SE/PMU OF 2026-27
Open Tender
CIVIL AND ELECTRICAL WORKS
Item Rate
135 days
NEW TOWN KOLKATA
Please refer Tender documents.
6 documents required · 6 mandatory
Exempted
PMU CONFERENCE ROOM
8 Sept 2026
9 Jul 2026
22 Aug 2026
10 Jul 2026
20 Aug 2026
6 Aug 2026
15 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Haroa Zone OHR 1-21 | - | - | - | - |
| 2 | Supply, Installation, commissioning up to the running condition of PRESSURE REDUCING VALVE.DIDF Pressure reducing Valve (PRV) comprising body, cover/bonnet and internal valve in Ductile iron/ SG iron; bronze trim; elastomer diaphragm & torroidal seals; stem, spring and fasteners of stainless steel; pilot relay assembly complete with isolating cocks, pressure gauge and copper tubing. Nominal Pressure: 1.6 Mpa. Flanges: BSEN 1092, Coating: Liquid Epoxy/Powder Coating -Blue RAL 5005, Purpose: To reduce a constant or variable inlet pressure to a predetermined constant (lower) outlet pressure, at varying flows. Adjustment of the outlet pressure should be possible simply by turning the screw on the Pilot/Relay Valve. Supplying following PRV, installation with all fittings and fixtures and commissioning, all complete as per specification and direction of Engineer (Description under Item Sl no 2 is applicable for Item Sl nos 3 to 6 below). | - | - | - | - |
| 3 | 100 MM Diameter for Z-6, 20. | 2 | Each | - | - |
| 4 | 150 MM Diameter for Z-1,2,3,4,5,7,8,9,10,11,12,13,14,15,16,17. | 16 | Each | - | - |
| 5 | 200 MM Diameter for Z-18,19 | 2 | Each | - | - |
| 6 | 250 MM Diameter for Z-21 | 1 | Each | - | - |
| 7 | Supply, Installation, commissioning up to the running condition of PLUNGER VALVE FCV. Electrical Actuator Controlled DIDF Plunger Flow Control Valve (FCV) comprising body in ductile iron having annular flow cross section; Plunger in SS 304 sliding on bronze guide by means of crank / shaft in SS 431, driven by warm gear box (having mechanical position indicator). EPDM seal on body is retained by SS 304 ring. Control cylinder in-built as anti -cavitation measure. Nominal Pressure: 1.6 Mpa. DIDF Plunger Flow Control Valve comprising of body in ductile iron having annular flow cross section; Plunger in SS 304 sliding on bronze guide by means of crank / shaft in SS 431, driven by warm gear box (having mechanical position indicator). EPDM seal on body is retained by SS 304 ring. Control cylinder in-built as anti -cavitation measure. Nominal Pressure : 1.0 and 1.6 Mpa, Actuator suitable for regulating duty Flanges : BSEN 1092 -2, Table 9 (with drilling as per ls 1538 Table 6, ls 9523 Table 4 or 5, EN 1092, Table 8 or 9) Coating : Liquid Epoxy / Powder Coating -BLUE RAL 5005, Flanges : BSEN 1092 -2, Table 9 (with drilling as per lS 1538 Table 6, ls 9523 Table 4 or 5, EN 1092, Table 8 or 9) Coating : Liquid Epoxy / Powder Coating -BLUE RAL 5005 Actuator suitable for regulating duty (SCADA COMPATIBLE) for inlet pipeline.
Supplying following FCV, installation with all fittings and fixtures and commissioning inclusive of interconnection with Analog Input and Output Card, installed in the OHR RTU and integration with existing SCADA system all complete as per direction of Engineer. (Description under Item Sl no 7 is applicable for Item Sl nos 8 to 11 below) | - | - | - | - |
| 8 | 100 MM Diameter for Z-6, 20. | 2 | Each | - | - |
| 9 | 150 MM Diameter for Z-1,2,3,4,5,7,8,9,10,11,12,13,14,15,16,17. | 16 | Each | - | - |
| 10 | 200 MM Diameter for Z-18,19 | 2 | Each | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
Section-4_Letter_Of_Price_Bid.pdf
Tender Documents • 0.50 MB
TECHNICAL_FOLDER_DRAWING-DETAILS OF VALVE CHAMBER (TENDER PURPOSE).pdf
Tender Documents • 0.23 MB
TECHNICAL_FOLDER_Section-1 ITB.pdf
Tender Documents • 0.69 MB
TECHNICAL_FOLDER_Section-2 Bid Data Sheet.pdf
Tender Documents • 0.74 MB
TECHNICAL_FOLDER_Section-3 Evaluation and Qualification Criteria.pdf
Tender Documents • 0.87 MB
TECHNICAL_FOLDER_Section-4 Bidding Forms.pdf
Tender Documents • 1.36 MB
TECHNICAL_FOLDER_Section-5 Eligible Countries.pdf
Tender Documents • 0.44 MB
TECHNICAL_FOLDER_Section-6 Project Scope and Specification_Smart Water.pdf
Tender Documents • 0.80 MB
TECHNICAL_FOLDER_Section-7 General Conditions of Contract.pdf
Tender Documents • 0.75 MB
TECHNICAL_FOLDER_Section-8 Particular Conditions of Contract.pdf
Tender Documents • 0.51 MB
TECHNICAL_FOLDER_Section-9 Contract Forms.pdf
Tender Documents • 0.96 MB
BOQ_2533074.xls
BOQ • 0.29 MB
CORRIGENDUM-I.pdf
PDF • 0.44 MB
ADDENDUM-I.pdf
PDF • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .