Executive Engineer
Executive Engineer Mechanical Division
Annual maintenance incidental repair of Air Conditioning machine installed in the North Tripura District hospital Dharmanagar during the year 202526
2026_CEPWD_74060_1
43_EE_DNIeT_MECH_AGT_202627
Open Tender
Electrical Works
365 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹6,724
23 Jun 2026
23 Jun 2026
3 Jul 2026
23 Jun 2026
3 Jul 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | General Servicing of 1.5/2.0 TR capacity AC machines (indoor & Outdoor unit) half yearly as per direction of the Engineer-in-charge. | 51 | Nos | - | - |
| 2 | Leak testing & leak repairing of condensing & evaporator unit by flushing nitrogen for performance and pressure testing etc for 1.5/2.0 TR capacities split type AC's and repair with brazing as per direction of the Engineer-in-Charge. | 8 | Nos | - | - |
| 3 | Providing & Charging of Non CFC Refrigerant gas to Split AC as per the direction of the Engineer-in-charge. | 16 | Nos | - | - |
| 4 | Providing & Fitting fixing of Compressor for 1.5 TR Capacity AC Machine as per the direction of the Engineer-in-charge. | 1 | Nos | - | - |
| 5 | Providing & Fitting fixing of new Compressor for 2.0 TR Capacity AC machine as per the direction of the Engineer-in-charge. | 1 | Nos | - | - |
| 6 | Repairing of indoor PCB Circuit as per the direction of the Engineer-in-charge. | 5 | Nos | - | - |
| 7 | Providing & Fitting fixing of new PCB Circuit (same brand with the machine to be repaired ) as per the direction of the Engineer-in-charge. | 3 | Nos | - | - |
| 8 | Providing & Fitting fixing of new PCB Circuit for 1.5/2.0 TR inverter AC (same brand with the machine to be repaired ) as per the direction of the Engineer-in-charge. | 1 | Nos | - | - |
| 9 | Fitting, fixing of blower motor of AC's after rewinding in/c necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer in charge. | 2 | Nos | - | - |
| 10 | Fitting, fixing of scroll motor of indoor unit of AC systems as per direction of the Engineer in charge. | 2 | Nos | - | - |