Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC H NO 963 10 STREET NO 5 DEEP NAGAR CIVIL LINES LUDHIANA 141001 PUNJAB | LUDHIANA | LUDHIANA | PUNJAB | 141001 | L1 | Accepted-AOC Accepted. | |
| 2 | L2₹9.4 L+₹1.5 L (19.2%)Rejected-Finance | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹9.4 L+₹1.5 L (19.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹9.5 L+₹1.6 L (19.7%)Rejected-Finance 0 3 SHASTRI STREET FEROZEPUR CITY PB PIN 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L4 | Rejected-Finance Other than lowest. |
Tender Value
₹10.1 L
EMD Value
₹20,200
Closing Date
8 Jun 2020, 6:00 pmClosed
GE Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana 141001
Special repair to bldg No. T-318 (OTM Accn) at Dholewal Mil Complex under GE Ludhiana
2020_MES_342050_1
GE/LDH-07/2020-21
Open Tender
Civil Works
Item Rate
120 days
Dholewal under GE Ludhiana
Refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹20,200
Yes
5 Aug 2020
1 May 2020
9 Jun 2020
1 May 2020
8 Jun 2020
9 May 2020
2 May 2020 - 8 May 2020
Amount
Sch 'A' Sec-I
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on brick or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified & directed by Engineer-in-charge
M & L, machine cut Kota stone slab flooring 20-25mm thick over and including 20 mm thick screed base in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing cutting and mirror type polishing complete all as specified and directed by Engineer-in-Charge.
Ditto as in item no. 3 but in skirting / dado/ vertical surfaces laid over 10mm thick cement screed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L, 25mm thick cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in floors finished even and fair complete all as specified and directed by Engineer-in-Charge.
M&L, 50mm thick cement concrete (1:3:6) type B-1 using 20mm crushed stone aggregate as in plinth protection finished even and fair complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each and removing from site all as specified & directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.00 Sqm each and removing from site all as specified & directed.
S&F, steel windows/ ventilator with side hung shutters incl box type hinge . With glazing bars and steel peg stay . Each window shutter is to be fitted with 1 steel handle 100 mm long casted out of MS Z section and two number of mild steel barrel tower bolts 150mm long on suitable size MS flat complete all as specified and directed by Engineer-in-Charge
S&F, steel windows/ ventilator with side hung shutters incl box type hinge . Without glazing bars and steel peg stay . Each window shutter is to be fitted with 1 steel handle 100 mm long casted out of MS Z section and two number of mild steel barrel tower bolts 150mm long on suitable size MS flat complete all as specified and directed by Engineer-in-Charge
M&L, mild steel work conforming to Fe-410 or Fe-310 quality-A as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, framed work of water tanks, door chowkats and similar works complete all as specified & directed by Engineer-in- charge.
Supply & fixing, galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanused wire staples all as specified &directed by Engineer-in- charge.
Supply and fixing, pressed steel frame size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. duly treated with one shop coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply & fixing, 35mm thick factory made plain framed panelled shutters (any no of panels) of 2nd class hard wood with lock rail and panel inserts of 9mm thick BWP commercial ply. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified & directed.
S&F, factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated and prepared to receive glass, gauge etc., without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. sizes of members as specified in clause 8.24 (a) of MES Schedule (Part-I), and fitted to chowkhats complete all as specified & directed by Engineer-in- charge.
Supply & fixing, helical door spring mild steel 300mm ordinary rat tail rod pattern mild steel frame including roller and roller plate and welding to frame as required complete complete all as specified and directed by Engineer-in-Charge.
M&L, preparing wooden or wood based surfaces (new) of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing, aluminium anodised barrel tower bolt of extruded section 150mm long all as specified & directed by Engineer-in- charge.
Supply and fixing, 250mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified & directed by Engineer-in-charge.
S&F, aluminium handles anodised cast type 125mm long all as specified & directed by Engineer-in-charge.
S&F, second class hardwood small fittings such as brackets of any type latch and hinge blocks, shaped door and window stops and the like including all necessary labours articles n exc 200cucm complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets any thickness including cover fillets complete all as specified and directed by Engineer-in-Charge.
Dismantling timber scantling framed work 40 sqcm and over in section in any position complete all as specified & directed by Engineer-in- charge.
S&F, GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screw 450mm centre to centre / intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section ( not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified & directed by Engineer-in- charge.
Supply & fixing, 4mm thick E-board; multipurpose, decorative type for false ceiling all as specified & directed by Engineer-in- charge.Make: Everest/ Charminar/ Lake & Hill.
S&F, hangers of 6mm dia GI (upto 1200mm length) adjusting level fixed roof slab by means of ceiling cleats made out of 40mm x 3mm GI flat 60mm long and expansion hold fastners 12.5mm dia, 40mm long complete all as specified & directed by Engineer-in- charge.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets and ridges in roof covering all as specified & directed by Engineer-in- charge.
S&F, pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified & directed by Engineer-in- charge.
S&F, pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified & directed by Engineer-in- charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified & directed by Engineer-in- charge.
M & L, mild steel conforming to Fe 290 Gde E-165 quality -A as in wind tie in roof covering complete all as specified & directed by Engineer-in- charge.
M & L, roof trusses framed, framed purlins, crane gantries, rails and fastenings (beams, tee, angle, channel or flat sections) including distance pieces conforming to Fe 410-W Gde E-250 quality -A complete all as specified & directed by Engineer-in- charge.
M&L, preparing steel and iron surfaces (new) of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer complete all as specified and directed by Engineer-in-Charge.
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer-in-Charge.
M&L, for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
All as per item No.35 above but except bricks. (Old serviceable bricks retrieved from demolition of brick work shall be re-used after cleaning).
M&L, rendering 15mm thick on brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified & directed by Engineer-in- charge.
M&L, rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified & directed by Engineer-in- charge.
M&L, preparing newly plastered or pointed surface of wall and applying three coats of white wash complete all as specified & directed by Engineer-in-charge
M&L, preparing old plastered or pointed surface of wall and applying two coats of white wash complete all as specified & directed by Engineer-in-charge.
M&L, preparing newly plastered or pointed surface of wall and applying two coats of cement base paint over a coat of white wash complete all asspecified & directed by Engineer-in-charge.
M&L, preparing old plastered or pointed surface of wall and applying one coat of cement base paint complete all asspecified & directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified and directed by Engineer-in-Charge.
M&L, cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed plates, coping, water trough, filling of chowkhats, roof kerbs or mud stops rounded or chamferred on edges complete all asspecified & directed by Engineer-in-charge.
Supply & fixing in repair curtain rod made out of 25mm dia (outer dia) pipe having thickness 0.63mm,PVC coated and colour / Pattern over all dia 28 to 29mm complete all as specified and directed by Engineer-in-Charge.
Supply & fixing, plastic finial of 28 to 29mm bore decorated type of any colour /Patern best quality to suit the curtain rod and fixed at the end of curtain rod with suitable adhesive complete all as specified and directed by Engineer-in-Charge.Make: Aerolux/MEC or VISTA
Supply & fixing, mild steel prepainting bracket to hold the curtain rod and fixed to wall (concrete /brick masonary) with the help of 2 Nos 50mm long steel screws and rawl plug included drilling with electric drill and making good the distrubed surfaces complete all as specified and directed by Engineer-in-Charge.
M&L, 100mm thick PCC (1:4:8) Type D-2 using 40mm graded stone aggregate as in floor, etc. finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L, 80mm thick machine pressed precast concrete interlocking paving blocks (any shape and size as ordered) conforming to IS 15658-2006 out of M-40 grade concrete casted with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in- charge.
Sch 'A' Sec-II
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sketch fitting, sockets, regulator etc and making good disturbed surfaces of walls and floors etc to match with the existing complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan, any sweep and size, sealing cable, dismantling fan blades, re-assembling the ceiling fan anf re-fixing in original position and making connections using new PVC insulated copper conductor cable of size 23/.0076 sqmm from ceiling rose to connector/ fan including supply and replacement of split pins complete all as specified and directed by Engineer-in-Charge.
M&L, Painting to ceiling fan of any make/ model/ sweep by removing old paint and filling cavaties with filler and applying one coat of super enamelled paint of colour as per existing using spray gun and writing MES numbers with black paint complete all as specified and directed by Engineer-in-Charge.
M&L point wiring complete with 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including concealed heavy duty PVC conduit including cutting chases in walls and making good the disturbed surface with all jointing accessories including provision of 3mm thick bakelite sheet top cover on new sunken boxes fixed with new screws & washers including 1.5 Sqmm FRLS, PVC insulated unsheathed stranded copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point/ bell point controlled by one switch or one fan point controlled by one switch through regulator complete all as specified and directed by Engineer-in-Charge.
All as per item No.53 above but for one 5 pin 5/6 Amps socket outlet on independent board.
All as described in Srl item No.53 above but for one 5 pin 5/6 Amps socket outlet on same board with other switch.
All as per item No. 53 here-in-before but with FRLS cable of cross sectional area 2.5 Sqmm for one socket outlet 15/16 Amps independent including 4 Sqmm FRLS, PVC insulated unsheathed solid conductor wire as earth continuity to common earth all as specified & directed.
S&F, in replacement 20 Watt LED decorative ultra slim linear LED light fittings fixture with co extruded polycarbonate body, environmental enegy efficient including connection from celing rose to connector complete with all acessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.Make Crompton Greaves cat part No LDL-20-WW or equivalent Bajaj / Philliips / Havells
M&L, submain wiring with three single core FRLS PVC insulated unsheathed multistranded copper conductor 2 runs cables of size 6 Sqmm FRLS PVC insulated copper conductor one run green insulation copper conductor cable as earth continuity drawn in and including medium grade PVC rigid non metelic conduit not less than 25mm dia with necessary conduit fittings concaeled in wall including cutting chases and making good the disturbed surface to match the existing surface including taking down existing submain wiring complete all as specified and directed by Engineer-in- charge. Make: Havells / Polycab / Finolex / Plaza, Note: 2 runs of 6 sqmm , 1 run of 6 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length
M&L, submain wiring with three single core FRLS PVC insulated unsheathed multistranded copper conductor 2 runs cables of size 4 Sqmm FRLS PVC insulated copper conductor one run green insulation copper conductor cable as earth continuity drawn in and including medium grade PVC rigid non metelic conduit not less than 25mm dia with necessary conduit fittings concaeled in wall including cutting chases and making good the disturbed surface to match the existing surface including taking down existing submain wiring complete all as specified and directed by Engineer-in- charge. Make: Havells /Polycab / Finolex / Plaza, Note: 2 runs of 4 sqmm , 1 run of 4 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length
Supply & fixing in replacement factory made sheet metal distribution boards, TPN, 4 way, double door; protection class IP-43 suitable for housing MCB/ isolators, conforming to IS-13032, IS-8623, BS-5484 with 200 Amps rated bus bar suitable for working on 240 volts AC supply and making niche, replacement to match with existing surface etc complete all as specified and directed by Engineer-in-Charge. Make: Legrand/Havells/L&T/Hagger
Supply & fixing in replacement MCB TPN 415 volt, 40 Amp with rupturing capacity 16 KA, 'c' series 50 Hz complete all as specified and directed by Engineer-in-Charge.Make: Standard /Havells/ Indo Asian / BCH / C&S
Supply & fixing in replacement MCB TPN 415 volt, 6-32 Amp , 16KA,'c' series complete all as specified and directed by Engineer-in-Charge.Make: Standard /Havells/ Indo Asian / BCH / C&S
S&F in replacement factory made sheet metal enclosure for distribution boards, SPN, 8 way; double door with 200 Amps rated bus bar suitable for housing MCBs and isolator and working on 240 volts AC supply including making good to match with existing surfaces complete all as specified & directed by Engineer-in- charge.Make: Hagger/L&T/Legrand / Indo Asian
Supply & fixing in replacement MCB SPN 240 volt, 6-32 Amp, 50 HZ, 10 KA rupturing capacity 'C' series all as specified & directed by Engineer-in- charge. Make: Standard /Havells/ Indo Asian / BCH / C&S
Supply & fixing in replacement MCB single pole 240 volt, 6 to 32 Amp, 50 HZ, 10 KA rupturing capacity 'C' series all as specified & directed by Engineer-in- charge. Make: Standard /Havells/ Indo Asian / BCH / C&S
Supply and fixing, ceiling rose surface bakelite 65x 50mm with two or three terminal, polycarbonate /pvc/ isolated body all as specified and directed by engineer in charge.
Supply and fixing, switch piano flush type single pole one way 5 Amps, 230 volts all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply and fixing, socket outlet 3 pin,5 Amp flush type all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply and fixing, switch socket combination two in one 5 Amp flush type all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply and fixing, switch socket combination two in one 3 pin 16 Amp flush type all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply & fixing, speed regulator for ceiling fan 1200mm/ 1400mm flush stapped type 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply & fixing, study lamp suitable with tiltting angle and suitable LED bulb 10W complete all as specified and directed by Engineer-in-Charge.Make: Havells/ CG / Bajaj / Philips
Supply & fixing, wall mounted fan, 230 volts single phase sweep 400 mm complete all as specified and directed by Engineer-in-Charge. Make: Havells / CG / Bajaj
Excavation in trenches soft/loose soil n. exc 1.5 metre wide for taking out/ laying unseviceable of LT cable, pipe line etc. and not exceeding 1.5 metre deep and getting out in soft/ loose soil complete all as specified & directed by Engineer-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified & directed by Engineer-in-charge.
Removal of excavated surplus spoil to a distance n.exc 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified & directed by Engineer-in-charge.
M & L, sand cushioning for under ground cable 23cm thick (one layer of 8cm thickness before laying the cable and other layer of 15cm thickness after laying the cable) all as specified and directed by Engineer-in-Charge. Note: Thickness of 18cm after punning shall be considered for payment.
M & L, brick protection with old size sub class 'B' bricks laid flat across the route of underground cable all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 25 sqmm 3.5 core laid in trenches/ ducts/ along poles/ through pipes including taking out existing cable complete all as specified & directed by Engineer-in- charge. Make: Havells / Polycab / CCI
Supply and fixing in replacement LED security light fitting LED 30 watt Epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 protection including with bracket bend to shape/size as require and fixing with two nos MS clamps for suitable size complete all as specified and directed by Engineer-in- charge. Make: Havells /CG/ Bajaj / Phillips
M&L, Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end connecions to main switch board and protected by galvanised iron light grade 40mm dia pipe, 20mm dia pipe for water with funnel, wire mesh, PCC chamber in cement concrete (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC cover (1:2:4) type B-1 using 20mm graded stone aggregate and 8mm dia TMT bar @ 10cm c/c both way including MS frame using MS angle of size 45mmx4mmx5mm complete all as specified and shown in electrical plate No-3 in MES Schedule (Part-I).Notes - (i) Outer edge of earth pit will be 1.5 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slantling position.(Earth wire and protection pipe upto 7.50m length is included in the unit rate)
JAY ANN CONSTRUCTION COMPANY
AGNIHOTRI CONSTRUCTIONS
Marwaha Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .