Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹8.0 L+₹35,250 (4.61%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹8.4 L+₹75,424 (9.87%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹10.0 L+₹2.4 L (31.2%)Rejected-AOC B 497 S F MEERA BAGH PASCHIM VIHAR NEW DELHI 110063 | WEST DELHI | DELHI | 110063 | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | Rejected-Technical | - | Rejected-Technical VERIFIED AND No remark in WLR CEBZ |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
31 Aug 2021, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PATTY REPAIR/ REWIRING OF INTERNAL ELECTRIC SUPPLY OF BUILDING INCLUDING SUB MAIN, DB AND ALLIED MAINT WORKS IN TECHNICAL AND RESIDENTIAL AREA AT DEAL UNDER GE (I) RND DEHRADUN
2021_MES_464371_1
GE(I)RND/9054/E8/21-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEHRADUN
Class E Category b (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2012) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
GE I R N D DEHRADUN
₹30,000
21 Sept 2021
2 Aug 2021
2 Sept 2021
2 Aug 2021
31 Aug 2021
9 Aug 2021
2 Aug 2021 - 9 Aug 2021
Amount
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch.
All as per Srl item No 2 above for point wiring for one light point controlled by two Nos two way switch omplete all as specified and directed.
All as per Srl item No 2 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches omplete all as specified and directed.
All as per Srl item No 2 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.omplete all as specified and directed.
All as per item No 2 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Make of cable and conduit: Havells/ Plaza/ Grandlay .
All as per item No 2 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Make of cable and conduit: Havells/ Plaza/ Grandlay .
All as per Srl item No 2 above but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent omplete all as specified and directed. Note for item 2 to 15 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs . (ii) Rate for modular metal flush boxes ,inner and outer plate with frames are deemed to be included in the quoted rate by contractor for above items. (iii) Fittings like Modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iv) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade (v) Make of cable : Finolex /Havells/ Poly cab as approved by GE. (vi) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE.
S&F Modular switch piano single pole one way 6 amp complete. Make -Legrand / Anchor Penta / Crabtree/MK/HPL as approved.
S&F Modular switch piano single pole one way 16 amp complete. Make - Legrand / Anchor Penta / Crabtree/MK/HPL as approved.
S&F Modular switch , 6 amp, single pole, two way complete. Make - Legrand / Anchor Penta / Crabtree/MK/HPL as approved.
S&F Modular bell push, 6 amp 240 volts complete. Make - Legrand / Anchor Penta / Crabtree/MK/HPL as approved.
S&F door bell, AC, 240 volts, single pole complete. Make - Legrand / Anchor Penta / Crabtree/MK/HPL as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete. Make -Legrand / Anchor Penta / Crabtree/MK/HPL as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete. Make -Legrand / Anchor Penta / Crabtree/MK/HPLas approved.
S&F ceiling rose 3 plates polycarbonate, isolated body complete. Make - Legrand / Anchor Penta / Crabtree/MK/HPL as approved.
S&F Angle holder, insulated polycabonate body with back plate suitable for batten fittings complete with One number LED lamp 9/10 Watt. Make of holder - Legrand / Anchor Penta / Crabtree/MK/HPL and Make of LED - Havells / Philips/ C&S as approved.
S&F modular fan step regulator 120 W 2 module complete. Make: Legrand / Anchor Penta / Standard/Crabtree as approved.
S&F in replacement of UNSV of Recess mounted 30/36 watts, 6500 k,4'x1' LED ceiling light fittings with slim line extruded aluminium / CRCA body, opal acrylic diffuser, electrinic driver etc and all accessories pre wired including connecting to mains complete all as specified and directed. Make: PLUTONEO4X1PLR36WLED857S of Havells or euivalent in Philips/C&S/ Crompton & Greaves.
S&F in replacement of UNSV fluorescent tube light fitting batten with universal batten fitting suitable for single T8 LED lamps complete all as specified and directed. Make: IGP161LT8-16 of C&G or euivalent in Philips/ Havells/CG
S&F in replacement of UNSV fluorescent tube light fitting batten with universal batten fitting suitable for twin T8 LED lamps complete all as specified and directed. Make: IGP162LT8-16 of C&G or euivalent in Philips/Havells/CG
S&F in replacement of UNSV fluorescent tube light with LED tube light 16 Watt T8 double sided connection with built-in driver, THD not more than 10% all as per C&G cat ref no LGT8-16-865-2 or equivalent in philips/Havells as approved.
S&F in replacement of UNSV LED mirror light fitting, 10 watts, 1000 lumens 6500K comprises of aluminium extruded channel, frosted diffuser, integrated electronic driver, IP 20 protection and all accessories pre- wired including connecting to mains complete all as directed. Make- LDL-10-CDL of C&G or equivalent in Havells/Phillips
S&F in replacement of UNSV bulkhead fitting with integrated LED bulk head fitting 600 lumens, 6000 K comprises of pressure die cast housing, acrylic diffuser and frame IP 65 protection, IK-07 etc including connection complete all as directed.Make- LBHP-10-CDL of C&G or equivalent in Havells/Phillips as approved.
S&F in replacement of UNSN Decorative, Wall mounting champagne gold finish fixture with plastic body along with 9 W LED lamp B22 base as per Havells cat ref no. LHFOECE1TZ1O014 or equivalent in Philips/C&S as approved.
Supplying, fixing & testing in replacement UNSV recess mounting in built ,36 Watts,2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- C&G Cat Pt No LCTLRNE-36-FO-CDL or equivalent in Phillips/Havells as approved.
Supplying & fixing, testing in replacement UNSV of surface mounted in built , LED 18 watts, 1'x1' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opel acrylic diffuser, electronic driver etc and all accessories pre-wired including connecting to source complete all as specified and directed. Make- Crompton cat pt No- LCTLSNE-18-FO-CDL or equivalent model of Havells / Philips as approved .
Supplying, fixing & testing in replacement UNSV of Highbay LED light fitting 150W with tapered fin design and excellent thermal management along with IP 65 protection complete all as specified & directed. Make- Cat Pt No SAUCERPLUSHBP150WLED85790DTOLTG of Havells or equivalent in Philips/ C&G as approved by GE
Fixing only fluorescent tube light 36 watt, complete and connecting the same to ceiling rose with using PVC sheathed and insulated three core copper conductor cable of size 0.50 Sqmm, including all accessories for fixing arrangement for fixing the light fitting to walls / ceiling surface complete all as specified & directed . NOTE:- Old fluorescent tube light fittings retrived under item No.01 and other item here in above shall be reused.
Dismantling and taking out existing unsv roadway light fitting of any type and in any position on walls/ poles and Supply , fixing and testing in 15 watt LED roadway street light made up of pressure die cast aluminium housing complete with polycarbonate cover with high impact resistance 15 W- 1500 lumen with efficiency of 100 lumens/ watts at system level, ingress protection of IP- 66, PF-0.9 & with input resistance,ie IK 07 surge protection upto 4 KV, compiled with IS 10322 CCT is greater than 5000K complete with all accessories duly pre-wired, including supply and fixing the bracket of 40 mm dia 60 cm long GI pipe light grade ,bent to shape including MS FI clampsof 20/25 x3 mm, nut and bolt and connected with flexible cable 3 core copper conductor 0.50 sqmm upto ceiling rose, mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. Make: Cat pt No. ENDURAPEARLSL15WLED757SASYTOPCMP of Havells or equivalent of C&G/Phillips/C&S as approved
S&F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp as required. Make of MCB SP 16/20 Amp- Cat Pt No. 811126/27 of IndoAsian orequivalent in Legrand/Seimens/Schneider Make of SPN DB with MCB 20Amp - CAt PT No 811956 of Indo Asian or equivalent in Legrand/Schneider as approved.
S&F in replacement UNSV of triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp, 415 Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp as required. Make of MCB SP 16/20 Amp- Cat Pt No. 811126/27 of IndoAsian or equivalent in Legrand/Seimens/Schneider Make of TPN DB with MCB 63Amp - CAt PT No 811962 of Indo Asian or equivalent in Legrand/Schneider as approved.
Taking down carefully energy meter any type, any capacity after disconnecting and refixing / connecting the same after complete of rewiring of Bldg/Qtr complete, all as specified and as directed by Engr-in-Charge.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.50 Sqmm as earth continuity conductor complete all as specified and directed.
Notes for item No. 41 & 42: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
M&L in replacement UNSV of sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed.
M&L in replacement UNSV of sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed.
Notes for Item 43 to 44 here in above : (i) Four run of single core PVC cable with two run of earth conductor and one run of conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
S&F in replecement of UNSV vertical type load line distribution board ,double door, 12way, AC 3 Phase 415 volt with TPN bus bar 250 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefitted masking sheeet,reversible door for IP 43-"IK 09 with metal door with provision for DPX3 160 MCCB as incomer and SP/TP MCB's as out going complete all as specified and directed by Engr-in-Charge. Make of VTPN DB:-IndoAsian cat Part No-811896 or equivalent make in Havells/L& T. Make of MCCB:- IndoAsian Cat pt No. 830295 or equivalent make in Havells/L& T
All as per item No 40 above but 8way complete all as specified and directed by Engr-in-Charge. Make of VTPN DB:-IndoAsian cat Part No-811895 or equivalent make in Havells/L& T. Make of MCCB:- IndoAsian Cat pt No. 830295 or equivalent make in Havells/L& T
All as per item No 50 above but 4way complete all as specified and directed by Engr-in-Charge.Make of VTPN DB:-IndoAsian cat Part No-811893 or equivalent make in Havells/L& T. Make of MCCB:- IndoAsian Cat pt No. 830295 or equivalent make in Havells/L& T
S&F in replacement of UNSV MCB distribution board SPN, 240 volts, 4 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Legrand Cat Pt No. 4025 05 or equivalent in Havells/L&T/Schneider/ IndoAsian as approved
All as per item No 53 above but SPN, 240 volts, 8 ways. Make - Legrand cat ref no 4025 07 or equivalent in Havells/L&T/Schneider/ IndoAsian as approved.
All as per item No 53 above but SPN, 240 volts, 12 ways. Make - Legrand cat ref no 4025 08 or equivalent in Havells/L&T/Schneider as approved.
Note for Item No.45 to 50(i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing (iii) Rate for Incomer MCCB is deemed to be included under above item.
Supply and fixed in replacement of UNSV MCCB 4 pole,160 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian cat part No. 830295 or equivalent in seimens / Schinder as approved by GE.
Supply and fixed in replacement of UNSV MCCB 4 pole,200 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian cat part No. 830295 or equivalent in seimens / Schinder as approved by GE.
All as per item No 52 above but, MCCB 4 pole ,100 Amps Complete all as specified and directed. Make- IndoAsian cat part No. 830272 or equivalent in seimens / Schinder/ IndoAsian as approved by GE .
All as per item No 52 above but MCCB 4 pole,63 Amps Complete all as specified and directed. Make- IndoAsian cat part No. 830270 or equivalent in seimens / Schinder/ IndoAsian as approved by GE.
Supply and fixed in replacement of UNSV MCB 3 pole, 50/ 63 Amps 415 volts, 50 Hz 'C' Curve having breaking capacity 10 KA , with thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian cat part No.811197/98 or equivalent in seimens / Schinder as approved by GE.
S & F in replacement of unserviceable MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 6 to 32 amps complete all as specified and directed.Make - IndoAsian cat ref no 811144/46/48/49/50/51 or equivalent in Hager or Schneider as approved.
S & F in replacement of unserviceable MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811122/24/26/27/28/29 or equivalent in Hager or Schneider as approved.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.
S&F in replacement of UNSV rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surfaces of following sizes:-
20 mm dia
25 mm dia
S&F in replacement of UNSV modular switch socket combination universal type 6/16 Ampswith box (2 hole complete with suitable connection with 2x2.5sqmm and 1x1.5sqmm single core cable length upto 01 mtr Make Legrand/Anchor Penta/Crabtree as approved.
S&F in replacement of UNSV modular switch socket combination universal type 6Amps with box (2 hole complete with suitable connection with 2x2.5sqmm and 1x1.5sqmm single core cable length upto 01 mtr Make Legrand/Anchor Penta/Crabtree as approved.
Fixing only recess mounted 30/36 watts, 6500 k,4'x1' LED ceiling light fittings make neccessary space to fix the same light fiiting on ceiling by dismanlting wall and ceiling boards (fibre pulp, insulation, etc) or insulation board/slabs/blankets any thickness including grid work/aluminium frame work, cover fillets and M&L for anodised aluminium snap grid frame work for false ceiling with grid size of 605mm x 605 mm and exposed metal frame ceiling with 8.00 mm thick fully Perforated calcium silicate board including insula-tion and accoustic purpose 605 mm x 605 mm in size, fixed with staple in ceiling to above mentioned frame work complete all as specified & directed. Note:- recess mounted 30/36 watts, 6500 k,4'x1' LED ceiling light fittings shall be measured and paid for separately under appropriate item of Sch ‘A’.
Repairing of tube light fittings upto 40 watt including replacement of UNSV of minor items like starter (Make - Philips or Wipro or Havells), bipin holder etc wherever required for satisfactory functioning complete. (Note:- Ballasts/drivers wherever found defective shall be measured and paid under relevant item of the schedule).
S&F in replacement of UNSV electronic ballast suitable for 1x36 / 2x36W watt tube light fitting having power factor not less than 0.94 and THD not more than 30% all as per Philips Sumo cat ref no. EB-FU 136 TL-D 240 V or equivalent in Wipro as approved.
S&F in replacement of UNSN electronic Driver suitable for 1x18 watt LED tube light fitting having power factor not less than 0.94 and THD not more than 30%. Make:Bajaj/Havells/Philips as approved.
S&Fin replacement of UNSN electronic Driver suitable for 1x34 to 42 Watt watt LED 2'x2' light fitting having power factor not less than 0.94 and THD not more than 30%. Make:Bajaj/Havells/Philips as approved.
S&F replacement of UNSV galvanized pressed steel terminal boxes concealed in wall of thickness 1.12 mm covered with phenolic laminated white sheet cover 3 mm thick in renewal of wooden/rusted boards of size 200 mm x 250 mm x 60 mm deep complete.
S & F in replacement of UNSV switch piano single pole flush type 5 amps, 230 volts complete,all as specified and as directed by Engr-in-Charge.
S&F in replacement of UNSVsocket out let 3 pin 5 Amps flush type complete, all as specified and directed by Engr-in-Charge.
S&F in replacement of UNSV switch piano flush type single pole way15 Amps complete, all as specified and as directed by Engr-in-Charge.
S&F in replacement of UNSV socket outlet 2 in 1 3 pin 5/15 Amps flush type complete all as specified and as directed by Engr-in-Charge
S&F in replacement of UNSN phenolic laminated white sheet cover 3.0 mm thick, cut into required size suitable for fixing on existing boards / terminal boxes for mounting switches, sockets, regulators as required.
JS CONSTRUCTION COMPANY
Deven Associates
SARVJEET ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .