| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.8 LAccepted-AOC 79 MAHENDRA BANARJEE ROAD BEHALA KOLKATA 700060 | KOLKATA | WEST BENGAL | 700060 | ₹68.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹69.2 L+₹36,572 (0.53%)Rejected-AOC 1080 JESSORE ROAD DUM DUM KOLKATA 700028 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700028 | ₹69.2 L+₹36,572 (0.53%) | L2 | Rejected-AOC Being L2 |
| 3 | L3₹70.8 L+₹2.0 L (2.96%)Rejected-AOC P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | ₹70.8 L+₹2.0 L (2.96%) | L3 | Rejected-AOC Being L3 |
| 4 | L4₹70.9 L+₹2.1 L (3.04%)Rejected-AOC PLOT NO 28 BRAHMESHWAR BAG TANKAPANI ROAD BHUBANESHWAR 751018 | KHORDHA | ODISHA | 751018 | ₹70.9 L+₹2.1 L (3.04%) | L4 | Rejected-AOC Being L4 |
| 5 | L5₹79.1 L+₹10.3 L (15.0%)Rejected-AOC 131 JANGALPUR ROAD AIRPORT GATE NO 3 3 NO MOTILAL COLONY 24 PARGANAS N KOLKATA 700081 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700081 | ₹79.1 L+₹10.3 L (15.0%) | L5 | Rejected-AOC Being L5 |
Tender Value
₹88.2 L
Closing Date
8 Nov 2021, 6:00 pmClosed
SAUBHIK PAN AGM EE
NEW OPERATIONAL BUILDING AAI NSCBI AIRPORT KOLKATA
Round the Clock Operation and Preventive Maintenance Contract of Cargo sub station.
2021_AAI_89765_1
AAI/EMD VIII/O and M CARGO/21-22
Open Tender
Electrical Works
Item Rate
730 days
NSCBI AIRPORT KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,120
Yes
Exempted
28 Mar 2022
21 Oct 2021
10 Nov 2021
22 Oct 2021
8 Nov 2021
22 Oct 2021
22 Oct 2021 - 27 Oct 2021
Amount
SH- I - Round the clock Operation & maintenance. Inspection, checking, cleaning, & monitoring 6 KV HT panels, 6 KV / 433 V, Transformers, LT panels, 2 nos. 500 KVA DG sets installed at cargo Substation i/c round the clock operation of DG sets. Carrying out all daily & weekly maintenance checks as per recommended maintenance schedule, all preventive maintenance as per specifications. All break down maintenance for all the equipments installed at Cargo Substation as when required. Providing all consumables of required quantities like cotton waste, distilled water, grease and hardware materials, control fuses, terminals blocks, ferrules, insulating tapes as per day to day maintenance requirement and all registers, log books and toos & plants etc. as per the requirement and as directed by the EIC. The minimum manpower provision as follows:- A. In general Shift Duty. (a) Electrical Engineer as per tender specification - 1 no. (b) Highly Skilled Manpower as per tender specification - 1 no. (c) Unskilled Manpower - 1 no. B. In Round the Clock Shift Duty. (a) Skilled Manpower - 2 location x 3 Shift = 6 nos. (b) Unskilled Manpower - 1 no. x 3 Shift = 3 nos. (A) Two year
SH-II : Maintenance of Battery Charger, planels & transformers. Checking & maintenance of batteries & battery charger sets installed at cargo substations for HT switchgears i/c. checking control wiring, tightening of all terminals after cleaning of terminals, providing petroleum jelly. Top up the batteries with distilled water etc. i/c. minors hardwares and spares complete as required. (a) First Year
Checking & maintenance of batteries & battery charger sets installed at cargo substations for HT switchgears i/c. checking control wiring, tightening of all terminals after cleaning of terminals, providing petroleum jelly. Top up the batteries with distilled water etc. i/c. minors hardwares and spares complete as required. (b) Second Year
Filtration & dehydration of transformer oil to improve the breakdown voltage of oil up to 50KV by oil filtration machine, carrying out BDV test of oil i/c. transportation of filtration machine to site etc. as required. (a) First Year
Filtration & dehydration of transformer oil to improve the breakdown voltage of oil up to 50KV by oil filtration machine, carrying out BDV test of oil i/c. transportation of filtration machine to site etc. as required. (b) Second Year
Maintenance of APFC panel, LT panels, AMF panels (monthly minimum one time and as and when required) installed in cargo substation of the airport area for improvement of power factor i/c. checking & tightening of the all terminals, checking, control wirings if required replace the faulty portion of control wiring. Providing necessary cleaning materials, insulating tapes, minor hardwares, wires, thimble/lugs, fennels etc. as required (capacitors and major components shall be supplied by the department). (2 nos. APFC panel, 2 no. LT Non Essential Panel, 2 No. Essential LT panel, 3 nos. AMF panels). (a) First Year
Maintenance of APFC panel, LT panels, AMF panels (monthly minimum one time and as and when required) installed in cargo substation of the airport area for improvement of power factor i/c. checking & tightening of the all terminals, checking, control wirings if required replace the faulty portion of control wiring. Providing necessary cleaning materials, insulating tapes, minor hardwares, wires, thimble/lugs, fennels etc. as required (capacitors and major components shall be supplied by the department). (2 nos. APFC panel, 2 no. LT Non Essential Panel, 2 No. Essential LT panel, 3 nos. AMF panels). (b) Second Year
Cleaning of luminaries, maintaining serviceability of emergency light in and around S/S building i/c. Up keeping of Electrical sub-station by i/c cleaning, uprooting of bushes / jungles etc. within the periphery of sub-station, as and when required as directed by Engg. I/C. (a) First Year
Cleaning of luminaries, maintaining serviceability of emergency light in and around S/S building i/c. Up keeping of Electrical sub-station by i/c cleaning, uprooting of bushes / jungles etc. within the periphery of sub-station, as and when required as directed by Engg. I/C. (b) Second Year
Topping up of transformer oil in the transformer by oil filtering machine including transportation and opening and closing nut / bolts / valves etc. as required. (a) First Year
Topping up of transformer oil in the transformer by oil filtering machine including transportation and opening and closing nut / bolts / valves etc. as required. (b) Second Year
Checking earth pit i/c. measurering the earth resistance bimonthly and repairing of earth pit wherever required by making necessary work, replacement of watering funnel, nut and bolts washers etc. and change broken cover by new cover i/c. cleaning, painting etc. as required. (a) First Year
Checking earth pit i/c. measurering the earth resistance bimonthly and repairing of earth pit wherever required by making necessary work, replacement of watering funnel, nut and bolts washers etc. and change broken cover by new cover i/c. cleaning, painting etc. as required. (b) Second Year
Overhauling & servicing of arresting leakage of transformer HT and LT side, conservator tank, Bucholz relay, top cover, all radiators, Bushing changing etc. of transformers at cargo substation with dehydration / filtration transformer oil etc. (a) Upto 500 KVA
Overhauling & servicing of arresting leakage of transformer HT and LT side, conservator tank, Bucholz relay, top cover, all radiators, Bushing changing etc. of transformers at cargo substation with dehydration / filtration transformer oil etc. (b) Above 500 KVA and up to 2000 KVA Transformer.
SH-III Maintenance of VCB / OCB & ACBs etc. Overhauling and servicing of existing LT ACB's of various makes up to 3200 Amp. Rating installed at cargo Sub-Stations at NSCBI Airport.
Overhauling and servicing of existing HT 6 KV / 11 KV OCB's / VCB's of various makes installed at cargo Sub-Stations at NSCBI Airport.
Replacement of faulty WTI & OTI of the existing transformer located at cargo Sub-Stations, NSCBI Airport.
SITC of silica gel breather as per sample in the existing transformer located at cargo Sub-Stations ,NSCBI Airport.
SH- IV - Painting etc. Cleaning the existing surface of cubicle panel at cargo substations & spray painting the same with two coats of ISI marked synthetic enamel paint of approved colour etc. as required.
Scrubbing, cleaning, the old paint from the existing surface of rolling shutters at cargo substations and painting the same with two coats of ISI marked synthetic enamel paint of approved colour etc. as required.
Scrubbing, cleaning the old paint from the existing surface of power transformer of following capacity located at cargo substations and spray painting the same transformers with two coats of ISI marked synthetic enamel paint / aluminum paint or as per existing paint of approved colour etc. as required. (a) Upto 500 KVA
Scrubbing, cleaning the old paint from the existing surface of power transformer of following capacity located at cargo substations and spray painting the same transformers with two coats of ISI marked synthetic enamel paint / aluminum paint or as per existing paint of approved colour etc. as required. (b) Above 500 KVA upto 2000 KVA Transformer.
Lettering of maximum 2" size (Alpha / numerical) on the finished painted surface of feeder pillar / panel / earth pits with synthetic enamel paint of approved colour etc. as required.
Cleaning, rubbing the old paint from the existing surface of DG set installed at cargo power houses and painting the same with heat proof spray painting with two coats of synthetic enamel paint of approved colour i/c. lettering, numbering etc. as required. Upto 500 KVA DG sets
Cleaning the surface of chequered plates at cargo sub-stations and painting with two coats of synthetic enamel black paint etc. as required.
Repairing of existing rolling shutter at cargo substations of various sizes after removing the same from existing frame and frame work, shutter rail, shaft, side guides and arrangement for inside operation etc. including all servicing, greasing, oiling, repairing of locking arrangement complete fixing as per direction of Engineer-in- charge .
ANIRBAN ENTERPRISE
Youngmen Traders
M/S DURGA SUPPLY AGENCIES
EASTERN POWER ENGINEERING
L K BUILDERS
CIS GLOBAL INFRATECH PRIVATE LIMITED
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .