Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹229.5 Cr
EMD Value
₹2.3 Cr
Closing Date
2 Dec 2026, 4:00 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Mr Ajay Kumar
Executive Engineer
Basudeopur, Munger Near I.T.C Company
DAYASHANKAR PRASAD
CHIEF ENGINEER (DESIGN)
Surveying, Collection of Hydrogeological data, Design, Detailed Engineering, Construction, Supply, Installation & Commissioning of Surface Water based Multi-Village Piped Water Supply Scheme having 22 MLD WTP & Intake Well at Kharagpur Lake, Master ESRs (3 Nos), Zonal ESRs (17 Nos), UGRs & Pump Houses (06 Nos), Raw Water Pipeline, Clear Water Trunk & Distribution Network, Electro-Mechanical Works with SCADA System, and Allied Works with minimum 6 months of Trail Run and thereafter Comprehensive Operation & Maintenance (Excluding Electricity Payment) for next 60 Months in 14 Panchayat of H. Kharagpur and Tetiya Bamber Block (Named H. Kharagpur-Tetiya Bamber MVS) in areas having ground water Quality issues (Fluoride/Iron/Arsenic Contamination) under P.H. Division Munger for year 2026-27.
142997
NIT-11/MUNG/PHED/2026-27
Open Tender
CIVIL
Munger
• Name of Bidder
• PAN No.
• GST No.
• E-Mail Id
• Mobile No.
• Business Address
CIVIL
ITEM RATE
L1
1
24 documents required · 24 mandatory
₹10,000
Processing Fee: 11800
₹2.3 Cr
Office of the Executive Engineer, P.H. Division, Munger
6 Nov 2026
6 Nov 2026
2 Dec 2026
6 Nov 2026
2 Dec 2026
6 Nov 2026
9 Nov 2026
180 days
TENDER NIT No.- 11/MUNG/PHED/2026-27
BILL OF QUANTITY (BOQ)
Name of The Work :- Surveying, Collection of Hydrogeological data, Design, Detailed Engineering, Construction, Supply, Installation & Commissioning of Surface Water based Multi-Village Piped Water Supply Scheme having 22 MLD WTP & Intake Well at Kharagpur Lake, Master ESRs (3 Nos), Zonal ESRs (17 Nos), UGRs (06 Nos) & Pump Houses, Raw Water Pipeline, Clear Water Trunk & Distribution Network, Electro-Mechanical Works with SCADA System, and Allied Works with minimum 6 months of Trail Run and thereafter Comprehensive Operation & Maintenance (Excluding Electricity Payment) for next 60 Months in 14 Panchayat of H. Kharagpur and Tetiya Bamber Block (Named H. Kharagpur-Tetiya Bamber MVS) in areas having ground water Quality issues (Fluoride Contamination) under P.H. Division Munger for year 2026-27.
Date of Tender :- 26.10.2026
Estimated Cost (Including GST and O&M for 5 years ) :- Rs.2,295,267,971.00
Earnest Money :- Rs.22,952,680.00
Time of Completion (In Months) :- 24 Months
Cost of BSEDC Bid processing fee:- As Applicable (To be Online Paid)
Cost of BOQ :- Rs.10,000.00 (To be Online Paid)
Name and Address of the Bidder
Sl. No. Work Description Unit Qty. Rate in Rs. Rate in Word Amount in Rs
SECTION-1: RAW WATER SOURCE DEVELOPMENT AND TRANSMISSION
1 Designing constructing and commissioning Raw Intake well of required dia including deep cutting edge /curb (length of curb is over and above well depth and shall be plugged properly at bottom with provision of RCC Watta at periphery. The scope includes the construction of a coffer dam or temporary island enclosure to provide a dry and accessible working area by excluding water during the foundation and sub-structure construction. Alternatively, suitable barge/pontoon-based or any other approved method may be adopted depending on site conditions to facilitate safe and efficient foundation work. Well shall be constructed in min RCC Grade M30. Intake well shall be constructed by open excavation or sinking well method in all type of soil and strata with in tilted and shift under specified to lerance limit with neat well steining and smooth firm RCC raft for bottom platform Required Jetting, blasting, kenteledge etc. shall be inclusive in rate, each including providing & fixing suitable valve with sluice gate and road etc. complete. provision of vertical access (MS Ladder with safety Lines to be provided for regular maintenance and inspection works. Constructing pump house over intake well of required dia and required height above floor level suitable arrangement like machine foundation and maintenance ramps and spill channels for mounting Pumping machinery or any suitable machinery at plinth level platform for installation of electrical panel and other working facilities, providing all structural work of channel joints, doors, rolling shutters, windows etc. for ventilation and the item includes gentry girders with end carriage arrangement (EOT Crane) & access as per contractor's own design as per requirement. comp. The super structural work in brick masonry or RCC M30, including internal and external plastering in cement mortar (1:4/1:6) for intake well walls, gallery, and pump floor surfaces, followed by application of approved waterproofing treatment where required, and finished with two coats of epoxy-based or weather-resistant paint as per specifications. Well, steining shall be done as required inside the well. Rate inclusive of necessary diversion of course. (Design shall be approved by consultants appointed by Department). Approach road having appropriate length and appropriate inner clear width required as per site conditions & as per contractor's own design etc. complete of required size. Approach Bridge shall be constructed framed structure shall be constructed on piles with bracing beams arrangement, deck slab. All sub structure shall be of R.C.C. M-300 for Piles/ Column outside Water & M-300 for Piles/ Column in side Water with CRS steel reinforcement, Beams & Deck slab and Super structure shall be in Structural steel.
It shall be sufficient strong enough to take the load of M.S. pipe with water load, Trolley with dead weight of Pump, Pipes & painting with anti-corrosive paint and provided pipe roller support,bank protection of river Any Item remains to be mention above but required for the work shall be deemed to have been included. The above structure shall be provided with lighting protection devices. Necessary lighting/ electrification arrangement shall be made for whole structure. The bidder has to submit detailed Topographical, hydrological & geo technical survey of the site based on this survey.
For 22 MLD Intake Structure Job 1.00 Rs.63,414,709.12 Rs.63,414,709.12
2 Supply, Installation, Testing and Commissioning of following pumping sets suitable for duty as specified
2A Intermediate Raw water lifting pumps :
Duty: to deliver raw water to pre-settling tanks entry point having discharge not less than 600 cum per hour (167 LPS) against a head of 40m as per design - 3 nos (2 no. working + 1 standby) including 2 sets of vacuum pumps matching with the system, common suction manifold of diameter not less than 1500 mm of suitable length to accommodate water of minimum 3 minutes pump running time, sluice valves with actuators for valves, non-return valves, common delivery manifold, sluice, non-return valves, anti-surge pressure valves all complete. This item includes provision for 2 nos Vacuum pumps as necessary for smooth operation of raw water pumping sets including provision for adjustment of fluctuations in river water level all complete by variable frequency measures/ any other suitable arrangements. Job 1.00 Rs.2,770,000.43 Rs.2,770,000.43
2B Pre-settled Water lifting pumps
Duty : To deliver pre-settled water to Cascade aerator of Treatment plant , to be located in the raw water pump house adjacent to Pre-setting tank having discharge not less than 600 cum per hour (210 LSP) against a head of 20 M as per design - 3 nos ( 2 working + 1 stand by) common suction manifold of diameter not less than 1500mm of suitable length to accommodate water of minimum 3 minutes pump running time, sluice valves with actuators , non-return valves, common delivery manifold, sluice, non-return valves, anti-surge pressure valves all complete. Job 1.00 Rs.2,400,176.69 Rs.2,400,176.69
3 Approach Road: Development of all weather road of carriage width not less than 3.75m, and shoulder of 1.20m width from river bank to the point of PST including cost of earth and filling up to 1mt above highest water level, WBM work and carpeting all complete. PM 1600.00 Rs.6,211.61 Rs.9,938,568.27 0
SECTION-2: CONSTRUCTION OF WATER TREATMENT PLANT AND PRE-SETTLING TANK
1 Design, construction, (including topographical survey, geotechnical investigation and other surveys as required) for 22 MLD capacity of WTP based on 22/16 hrs. operation including inlet chamber, pre settling tank, pump house,aeration fountain / cascade, inlet channels including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and automated flow measuring arrangement, clariflocculator with conventional filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby, store house cum electrical and mechnical workshop sludge handling unit and recycling of collected water from sludge, clear water reservoir of specified capacity, clear water pumping station including specified number and capacity of pumps, motors, panels, starters, cables, transformers, panel room, etc. complete, external and internal electrification, laboratory building with all specified lab equipment, admin building, Quarter (One no.), sanitary block with necessary water supply and drainage arrangement, campus roads, landscaping, horticulture and other campus development works, rain water harvesting etc. all required works complete as per the direction of Engineer-in-Charge. Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. The design shall conform to IS / CPHEEO Manual. Job 1.00 Rs.74,176,480.00 Rs.74,176,480.00
SECTION-3 : CONSTRUCTION OF STORAGE FACILITY
1 Preparing structural design of RCC Under Ground / Partially under ground / above high ground level Reservoir of required capacity as per relevant I.S. standards and constructing the same, including excavation in all types of soil strata (including rock) including shoring strutting if required, for loose soil / to protect from collapse, casting 100 mm thick P.C.C. levelling course in M-15, Refilling the pit with proper soil and disposing of the surplus stuff at all lead. Including cement plaster in CM 1:2 with approved water proofing compound to all over inside container (i.e. walls, base, top slab/dome bottom etc. all). Including all types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design. Providing and fixing accessories, CI Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail. RCC chambers for valves. Providing and applying three coats of cement paint / snowcem to the out side face of structure. It also includes satisfactory water tightness test as per relevant I.S. code and painting name of scheme and capacity on the tank as per direction of engineer in charge. List of Indian Standards for Design of GSR / SUMP:- The structural design of GSR shall be in accordance with provisions relevant I.S standards - (1) I.S. 3370 part I & II 2009 or Its latest revision, (1.1) I.S. 3370 part III & IV 1965 or Its latest revision, (2) I.S. 456 – 2000 or Its latest revision., (3) I.S. 1893 – 2000 – 1984 or Its latest revision., (4) I.S. 875, Part – 1 to 3, 1987 or Its latest revision., General Specifications:- (1) Water depth in container shall be adopted as per data of tender. Capacity shall be calculated excluding free board of the reservoir. If water depth is not specified, the suitable water depth / acceptable to field engineer in accordance with hydraulic, (2) Shape of container (in plan) specified by in data shall be adopted in absence circular shall be adopted., (3) Size shall be fixed as per availability of space (land area) at site / acceptable engineer in charge., (4) Effect of overlapping of pressure bulbs on soil due near by structure and proposed sump should be considered, (5) Care shall be taken that no damage should occur to nearby existing structure. Compensation shall be paid for the same by agency, (6) The minimum concrete grade for RCC shall be M-30.,
(7) HYSD Fe 415 / 500 grade reinforcing bars confirming to I.S. 1786 / 1139 shall be considered in design. CRS / TMT bars shall be provided. In saline atmosphere corrosion resistance stainless steel / HCR rebar shall be provided. Any other steel can be used with approval of C.E./ in situation of non availability in market without extra cost. (8) Minimum size (or thickness) of various components shall be provided as per tender criteria / specifications in absence as per I.S./ Std. practice. Minimum dimensions specified for various components in tender data / specifications shall be provided without fail., (9) The safe bearing capacity (SBC) shall be referred from SBC test report. In absence of report it shall be referred from data sheet. If poor soil is found / water table is met with during excavation SBC shall be scientifically ascertained and design shall be revise. No extra shall be paid for increase in quantity., (10) DI pipes and special shall only be used if type is not specified in tender., (11) The rate shall include cost of dewatering during excavation making all arrangement when water table meets within depth., (12) The structure shall be designed properly to resist uplift due to ground water table specified in data or actual ground water table meets with during excavation. If GWT / Uplift is mentioned in tender and during excavation it dose not meet 7.5% rate shall be reduced., (13) SS pipes railing shall be provided over sump perifery when sump height is ≥ 1.5 meter above ground level., (14.a) RCC staircase/RCC Steps should be provided from GL to sump top slab based on the height of the GSR above/below the ground., (14.b) RCC Staircase with SS railing to be provided inside reservoir container. BB Masonry staircabin with MS safety door having locking arrangement to be provided for GSR, Sump and HGLR of capacity more than 7.5 Lakhs liter with top slab. If dome is constructed as top slab then provide minimum opening of 900 mm x 2000 mm with curbing and SS railing around. (15) Appearance of structure should be aesthetically good looking acceptable to authority., (16) Any change in size, shape, depth below GL, height above GL, water depth, F.B., size of member etc can be permitted in exceptional case due to site condition or hydraulic design requirement by C.E. No extra shall be paid for change., (17) Any change in data, dimensions, shape, water depth, reduction in size if permitted by competent authority and if it reduces quantity then payment shall be reduced prorate., (18) When capacity of GSR / Sump is > 20 lakh litres two or suitable compartments acceptable to executive engineer shall be designed and provided.,
(19) Agency shall engage qualified (at least graduate) consulting engineer for designing the structure and he / she shall visit the site for guidance of work., (20) 75% part rate shall be payable for concrete, reinforcement and plastering items of container until satisfactory hydraulic testing for water tightness is performed as per tender condition. Till the work shall be treated as incomplete.
At Treatment plant site of effective storage capacity of 4000 Cum Job 1.00 Rs.39,375,000.00 Rs.39,375,000.00
2 Design, detail engineering, soil investigation work, preparation of working drawing, Construction of RCC Master Elevated Service Reservoir a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.
p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
2.1 At Treatment plant site of storage capacity of 3800KL staging Height -25M Job 1.00 Rs.41,810,640.00 Rs.41,810,640.00
2.2 At IPS-1 site of storage capacity of 2250 KL stagin g Height -25M Job 1.00 Rs.24,756,300.00 Rs.24,756,300.00
2.3 At IPS-2 site of storage capacity of 850 KL staging Height -25M Job 1.00 Rs.12,307,660.00 Rs.12,307,660.00
3 Design, detail engineering, soil investigation work, preparation of working drawing, Construction of RCC Zonal Elevated Service Reservoirs at various locations under the command area of the project, of effective storage capacity as listed below,
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.
p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. Work Includes feeding of treated water from ESR to Existing 358 WLS & 39 Proposed WLS Schemes in command area.
3.1 200 KL capacity 18 M Staging in Ramankabad East Panchayat Each 1.00 Rs.3,878,000.00 Rs.3,878,000.00
3.2 400 KL capacity 18 M Staging in Manjhgain Panchayat Each 1.00 Rs.6,984,000.00 Rs.6,984,000.00
3.3 500 KL capacity 18 M Staging in Dariyapur-1 Panchayat Each 1.00 Rs.8,230,000.00 Rs.8,230,000.00
3.4 500 KL capacity 18 M Staging in Murade Panchayat Each 1.00 Rs.8,230,000.00 Rs.8,230,000.00
3.5 500 KL capacity 18 M Staging in Bhuna Panchayat Each 1.00 Rs.8,230,000.00 Rs.8,230,000.00
3.6 500 KL capacity 18 M Staging in Kesauli Panchayat Each 1.00 Rs.8,230,000.00 Rs.8,230,000.00
3.7 150 KL Capacity intermediate ESR, 18 M staging in Kesauli Panchayat Each 1.00 Rs.3,361,500.00 Rs.3,361,500.00
3.8 500 KL capacity 18 M Staging in Nonaji Panchayat Each 1.00 Rs.8,230,000.00 Rs.8,230,000.00
3.9 500 KL capacity 18 M Staging in Dhauri Panchayat Each 1.00 Rs.8,230,000.00 Rs.8,230,000.00
3.10 600 KL capacity 18 M Staging in Dariyapur-2 Panchayat Each 1.00 Rs.9,018,000.00 Rs.9,018,000.00
3.11 600 KL capacity 18 M Staging in Banhara Panchayat Each 1.00 Rs.9,018,000.00 Rs.9,018,000.00
3.12 150 KL Capacity intermediate ESR, 18 M staging in Banhara Panchayat Each 1.00 Rs.3,361,500.00 Rs.3,361,500.00
3.13 600KL capacity 18 M Staging in Ramankabad west Panchayat Each 1.00 Rs.9,018,000.00 Rs.9,018,000.00
3.14 700 KL capacity 18 M Staging in Gangta Panchayat Each 1.00 Rs.9,996,000.00 Rs.9,996,000.00
3.15 700 KL capacity 18 M Staging in Bangama Panchayat Each 1.00 Rs.9,996,000.00 Rs.9,996,000.00
3.16 150 KL Capacity intermediate ESR, 18 M staging in Bangama Panchayat, Each 1.00 Rs.3,361,500.00 Rs.3,361,500.00
3.17 800 KL capacity 18 M Staging in Tetia Panchayat - 1 No. Each 1.00 Rs.10,928,000.00 Rs.10,928,000.00
4 Preparing structural design of Zonal RCC Under Ground / Partially under ground / above high ground level Reservoir of following capacity as per relevant I.S. standards and constructing the same, including excavation in all types of soil strata (including rock) including shoring strutting if required, for loose soil / to protect from collapse, casting 100 mm thick P.C.C. levelling course in M-15, Refilling the pit with proper soil and disposing of the surplus stuff at all lead. Including cement plaster in CM 1:2 with approved water proofing compound to all over inside container (i.e. walls, base, top slab/dome bottom etc. all). Including all types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design. Providing and fixing accessories, CI Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail. RCC chambers for valves. Providing and applying three coats of cement paint / snowcem to the out side face of structure. It also includes satisfactory water tightness test as per relevant I.S. code and painting name of scheme and capacity on the tank as per direction of engineer in charge. List of Indian Standards for Design of GSR / SUMP:- The structural design of GSR shall be in accordance with provisions relevant I.S standards - (1) I.S. 3370 part I & II 2009 or Its latest revision, (1.1) I.S. 3370 part III & IV 1965 or Its latest revision, (2) I.S. 456 – 2000 or Its latest revision., (3) I.S. 1893 – 2000 – 1984 or Its latest revision., (4) I.S. 875, Part – 1 to 3, 1987 or Its latest revision., General Specifications:- (1) Water depth in container shall be adopted as per data of tender. Capacity shall be calculated excluding free board of the reservoir. If water depth is not specified, the suitable water depth / acceptable to field engineer in accordance with hydraulic, (2) Shape of container (in plan) specified by in data shall be adopted in absence circular shall be adopted., (3) Size shall be fixed as per availability of space (land area) at site / acceptable engineer in charge., (4) Effect of overlapping of pressure bulbs on soil due near by structure and proposed sump should be considered, (5) Care shall be taken that no damage should occur to nearby existing structure. Compensation shall be paid for the same by agency, (6) The minimum concrete grade for RCC shall be M-30., (7) HYSD Fe 415 / 500 grade reinforcing bars confirming to I.S. 1786 / 1139 shall be considered in design. CRS / TMT bars shall be provided. In saline atmosphere corrosion resistance stainless steel / HCR rebar shall be provided. Any other steel can be used with approval of C.E./ in situation of non availability in market without extra cost. (8) Minimum size (or thickness) of various components shall be provided as per tender criteria / specifications in absence as per I.S./ Std. practice. Minimum dimensions specified for various components in tender data / specifications shall be provided without fail., (9) The safe bearing capacity (SBC) shall be
referred from SBC test report. In absence of report it shall be referred from data sheet. If poor soil is found / water table is met with during excavation SBC shall be scientifically ascertained and design shall be revise. No extra shall be paid for increase in quantity., (10) DI pipes and special shall only be used if type is not specified in tender., (11) The rate shall include cost of dewatering during excavation making all arrangement when water table meets within depth., (12) The structure shall be designed properly to resist uplift due to ground water table specified in data or actual ground water table meets with during excavation. If GWT / Uplift is mentioned in tender and during excavation it dose not meet 7.5% rate shall be reduced., (13) SS pipes railing shall be provided over sump perifery when sump height is ≥ 1.5 meter above ground level., (14.a) RCC staircase/RCC Steps should be provided from GL to sump top slab based on the height of the GSR above/below the ground., (14.b) RCC Staircase with SS railing to be provided inside reservoir container. BB Masonry staircabin with MS safety door having locking arrangement to be provided for GSR, Sump and HGLR of capacity more than 7.5 Lakhs liter with top slab. If dome is constructed as top slab then provide minimum opening of 900 mm x 2000 mm with curbing and SS railing around. (15) Appearance of structure should be aesthetically good looking acceptable to authority., (16) Any change in size, shape, depth below GL, height above GL, water depth, F.B., size of member etc can be permitted in exceptional case due to site condition or hydraulic design requirement by C.E. No extra shall be paid for change., (17) Any change in data, dimensions, shape, water depth, reduction in size if permitted by competent authority and if it reduces quantity then payment shall be reduced prorate., (18) When capacity of GSR / Sump is > 20 lakh litres two or suitable compartments acceptable to executive engineer shall be designed and provided., (19) Agency shall engage qualified (at least graduate) consulting engineer for designing the structure and he / she shall visit the site for guidance of work., (20) 75% part rate shall be payable for concrete, reinforcement and plastering items of container until satisfactory hydraulic testing for water tightness is performed as per tender condition. Till the work shall be treated as incomplete.
4.1 At IPS-1 site at Panchayat Banhara of effective storage capacity of 2500 Cum Each 1.00 Rs.11,350,000.00 Rs.11,350,000.00
4.2 At IPS-2 site at Panchat Gangta of effective storage capacity of 1000 Cum Each 1.00 Rs.8,694,000.00 Rs.8,694,000.00
4.3 At Zonal IPS at Bangama panchayat of effective storage capacity of 200 Cum Each 1.00 Rs.1,116,000.00 Rs.1,116,000.00
4.4 At Zonal IPS at Banhara panchayat of effective storage capacity of 200 Cum Each 1.00 Rs.1,116,000.00 Rs.1,116,000.00
4.5 At Zonal IPS at Kesauli panchayat of effective storage capacity of 200 Cum Each 1.00 Rs.1,116,000.00 Rs.1,116,000.00
5 Clear water pumping sets:
5.1 Clear water pumping sets for Master ESR:
Design, detail engineering, procurement, supply, installation, testing and commissioning of Clear Water Pumping sets, preferably, horizontal centrifugal type, having rated discharge of 600 cum per hour capable of filling Master elevated service reservoir including motor having 25% margin over rated BHP, base plate, coupling, pipelines, common suction and delivery manifold, Non-return valves, sluice valves, instrumentation, MCC panels all complete, to be housed in clear water pump house. No of pumping sets = 3 ( 2 working and 1 stand- by). Job 1.00 Rs.2,770,000.43 Rs.2,770,000.43
5.2 Clear water pumping sets for Master ESR at intermediate pumping stations :
Design, detail engineering, procurement, supply, installation, testing and commissioning of Clear Water Pumping sets, preferably, horizontal centrifugal type, having rated discharge of 250 cum per hour capable of filling Master elevated service reservoir including motor having 25% margin over rated BHP, base plate, coupling, pipelines, common suction and delivery manifold, Non-return valves, sluice valves, instrumentation, MCC panels all complete, to be housed in clear water pump house. No of pumping sets = 3 ( 2 working and 1 stand by).At IPS-1 Job 1.00 Rs.915,355.68 Rs.915,355.68
5.3 Design, detail engineering, procurement, supply, installation, testing and commissioning of Clear Water Pumping sets, preferably, horizontal centrifugal type, having rated discharge of 90 cum per hour capable of filling Master elevated service reservoir including motor having 25% margin over rated BHP, base plate, coupling, pipelines, common suction and delivery manifold, Non-return valves, sluice valves, instrumentation, MCC panels all complete, to be housed in clear water pump house. No of pumping sets = 3 ( 2 working and 1 stand by).at IPS-2. Job 1.00 Rs.677,414.50 Rs.677,414.50
5.4 Design, detail engineering, procurement, supply, installation, testing and commissioning of Clear Water Pumping sets, preferably, horizontal centrifugal type, having rated discharge of 6.94 LPS (7.5 HP) capable of filling Zonal elevated service reservoir including motor having 25% margin over rated BHP, base plate, coupling, pipelines, common suction and delivery manifold, Non-return valves, sluice valves, instrumentation, MCC panels all complete, to be housed in clear water pump house. No of pumping sets = 2(1 working and 1 stand by).at Zonal IPS at Three locations. Nos 6.00 Rs.51,389.83 Rs.308,338.98
SECTION-4: MS PIPE, D.I PIPE & HDPE PIPE NETWORK.
A Raw Water Conveying Main Mipe.
1 Raw water conveying pipes: Pre-settled water conveying pipes- 700 mm dia MS pipe including laying , jointing, wrapping, coating and providing anchor block, thrust block, air valves, sluice valves, non-return valves all complete.
700 mm Dia, 10mm thk MS Pipe including corrosion Protection coatings. PM 5500.00 Rs.17,156.78 Rs.94,362,290.00
2 Providing and making inner cement mortar lining to M.S. Pipes with mechanical devices in cement mortar 1:1 proportion , including cost of all materials, labour, special sand required, machinery, power generation, all equipments, including carrying out "C" value performance test of pipeline, including field joints at site complete as per technical specification and direction of Engineer in In charge. . Sqm 12096.70 Rs.288.98 Rs.3,495,704.37
3 Providing and applying DFBE ( Dual Layer Fusion Bonded Epoxy) Coating to the external surface of M.S. Pipes conforming to Canadian Standard CSA Z 245.20-10, consisting of 1st layer of (FBE) Fusion Bonded Epoxy powder and 2nd layer also of FBE powder as Abrasion Resistant Overcoat (ARO) including preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2 including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Minimum thickness of coating shall be 600 micron. Sqm 27517.67 Rs.808.47 Rs.22,247,210.61
B Clear Water Rising Main
1 Surveying, leveling, designing of Clear water conveying main feeders considering filling time of each Zonal ESRs to be less than 4 hours simultaneously/ in segment -wise with a free fall head of not less than 2mt by using software -simulated program with C value = 100, preparation of route drawing showing road crossings, position of ESRs , terminals points of each pipe up to location to be confirmed by E-in-C within the command area of the project, procurement of Ductile Iron pipe K9 category , supply , unloading at locations of laying, supply of fittings and fixtures including isolating sluice valves, air valves, scour valves, laying, jointing, testing of pipelines, construction of valve chambers, and commissioning of the network to the satisfaction of E-in- C all complete. 0
250 mm diameter DI K-9 Pipe PM 9295 Rs.5,281.70 Rs.49,093,371.76 0
300 mm diameter DI K-9 Pipe PM 15717 Rs.6,251.01 Rs.98,247,105.31 0
350 mm diameter DI K-9 Pipe PM 5264 Rs.7,568.01 Rs.39,837,998.32 0
400 mm diameter DI K-9 Pipe PM 7749 Rs.9,234.80 Rs.71,560,496.20 0
500 mm diameter DI K-9 Pipe PM 8796 Rs.12,677.97 Rs.111,515,413.56 0
600 mm diameter DI K-9 Pipe PM 12272 Rs.14,990.62 Rs.183,964,898.46 0
700 mm diameter DI K-9 Pipe PM 5236 Rs.20,071.08 Rs.105,092,174.88
C Distribution Main (Zonal ESR TO WLS Water Tank) 0
1 Survey, Design, Providing, laying, Jointing & field testing of High Density Polythenepipes, (HDPE) conforming to IS 4984/14151/12786/13488 with necessary jointing material line mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with jacks/hydraulic jacks/ But fusion machine, (50mm & above fusion jointed & below 50mm mechanical jointed). It includes fittings i.e gate valves, sluice valves and other required materials to complete the connection to existing WLS Schemes. 0
63 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.1) PM 44322 Rs.795.47 Rs.35,256,732.70 0
75 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.2) PM 28315 Rs.901.88 Rs.25,536,777.50 0
90 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.3) PM 87200 Rs.1,069.40 Rs.93,252,028.80 0
110 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.4) PM 55710 Rs.1,344.39 Rs.74,896,167.46 0
125 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.5) PM 31335 Rs.1,551.95 Rs.48,630,440.99 0
140 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.6) PM 29783 Rs.1,805.87 Rs.53,784,238.12 0
160 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.7) PM 23098 Rs.2,187.27 Rs.50,521,645.61 0
200 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.8) PM 22960 Rs.3,166.07 Rs.72,692,921.28 0
250 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.9) PM 15980 Rs.3,649.67 Rs.58,321,732.99 0
315 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.10) PM 10987 Rs.5,432.36 Rs.59,685,356.90 0
2 Providing house connection for new and left out house hold in existing schemes including supplying all materials, labours, tools and making ferrule connection with 20 mm dia with all fittings etc all complete. Nos. 13100 Rs.2,739.36 Rs.35,885,616.00 0
3 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.
300 mm Dia 8 mm thick casing pipe. Rmt 220 Rs.5,505.08 Rs.1,211,117.60
400 mm Dia 8 mm thick casing pipe . Rmt 180 Rs.6,938.98 Rs.1,249,016.40
600 mm Dia 10 mm thick casing pipe . Rmt 20 Rs.14,684.75 Rs.293,695.00
700 mm Dia 10 mm thick casing pipe . Rmt 40 Rs.17,156.78 Rs.686,271.20
4 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : For Sluice Valve
5 Constructing masonry Chamber 120x120x100 cm( Depth Upto pipe invert level) inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S ( non modular) bricks of class designation 100 A. Nos. 153.00 Rs.19,810.42 Rs.3,030,994.16 0
6 Reparing of Existing House service connection including excavation, supply of required MDPE pipes, taps, etc complete for proper completion of work. Nos. 2400.00 Rs.801.79 Rs.1,924,296.00
7 Repairing of Existing House Connection in case leakage at Ferrule including excavation, supply of required MDPE pipes, taps, etc complete for proper completion of work. Nos. 3450.00 Rs.1,667.85 Rs.5,754,082.50
8 Strengthening, repairing, painting, replacing of required steel and GI sheets(including supply of steel and sheets) for pump house and Existing steel staging of 8m height making the structure in good working condition and repairing of tank if required etc complete for proper completion of the work. Nos. 74.00 Rs.170,683.00 Rs.12,630,542.00
SECTION-5: DEVELOPMENT WORK 0
1 Development of land by raising with locally available sandy soil unto Finished ground level which is to be determined at least 500 mm above Finished GL. Cum 9000.00 Rs.482.67 Rs.4,343,987.72 0
2 Design , detail engineering, preparation of drawings, construction of Boundary wall along the property line of height not less than 1500 mm above finished ground level. (WTP Area, Intermediate Pumping Station & ESR. PM 3600.00 Rs.14,730.62 Rs.53,030,229.84 0
3 Design , detail engineering, preparation of drawings, construction of RCC two-storied twin type Staff quarters having 200 sqmt plinth area per floor and Admin Building 320 Sqmt. Etc. all complete as per directions of Engineer-in-charge. Job 1.00 Rs.20,050,915.88 Rs.20,050,915.88 0
4 Providing & Fixing Iron gates for compound wall of required size & specification as per the drawings to be submitted with 2 No of R.C.C. column size 0.45 x 0.45 m ( including reinforcement) with 15 mm thick cement plaster to all exposed surface including excavation in all strata, P.C.C., form work for R.C.C. work , painting to all Iron exposed surfaces( incl. brusing , cleaning & priming coat ) and cleaning the site etc. the site etc. complete. ( WTP Location -1 Nos., IPS Location - 5 Nos, Zonal ESR Locatoion - 17 Nos.) Each 21.00 Rs.68,580.14 Rs.1,440,182.94 0
SECTION-6 :ELECTRICAL WORK
1 Power connection, External and Internal illumination
Design, detail engineering, procurement, supply, fitting, fixing of electrical works for internal and external lighting in the treatment plant complex, zonal ESRs , including supply of MS Electric poles, all cables, transformers, MCC panels and other accessories as required all complete including external and internal illumination as per IE rules as necessary as well as getting power connection from BSEB for the WTP complex and all the electrical works from the sub-station point onwards etc all complete. Job 1.00 Rs.20,692,916.00 Rs.20,692,916.00
2 Extra for additional route length of HT transmission line from BSES sub Station to WTP area. KM 1.00 Rs.1,878,954.00 Rs.1,878,954.00
3 Electrical back-up facility
Provision for 300 KVA Diesel generator Nos. 2.00 Rs.2,460,216.00 Rs.4,920,432.00
4 Solar Panel :
Provision for Solar lights for external and emergency internal illumination in Water Treatment Plant complex, Zonal ESRs, compound lighting, staff quarters, compound lighting etc as per approval LS 10.00 Rs.957,348.00 Rs.9,573,480.00
5 Automation and SCADA facility
Design, supply, installation, testing, and commissioning of instrumentation equipments for raw water and clear water pumping stations. The scope includes the supply and installation of all necessary instrumentation devices such as pressure gauges and pressure transmitters on delivery and header pipes, ultrasonic level transmitters for level measurement of all ESRs & WLS Tanks, level switches, float and board type level indicators, full bore electromagnetic flow meters, PLC panels, and Fully automated SCADA system. The work also includes laying of all required instrumentation cables, termination, and associated accessories, along with all allied instrumentation works, complete with necessary hardware and supports. All works shall be executed as per approved design and drawings, relevant standard specifications, and as directed by the Engineer-in-Charge. job 1.00 Rs.36,111,210.02 Rs.36,111,210.02
The SCADA system shall integrate the field-level instrumentation and control equipment at all project locations through PLCs, RTUs, or equivalent controllers. Communication between remote facilities and the central control room may be established through suitable media such as optical fiber, Ethernet, radio, or cellular communication, depending on site conditions and network availability. The proposed architecture shall generally comprise: Field instrumentation: Flow meters, level transmitters, pressure transmitters, water quality analyzers, and equipment status signals. Local control panels: PLC/RTU panels, motor control interfaces, signal conditioning, and local operator controls. Communication network: Industrial communication equipment and protocols suitable for reliable data exchange between remote stations and the central control room. Central SCADA system: Supervisory software, operator workstations, data logging, alarm management, trends, and reporting. Power backup and protection: Suitable UPS, surge protection, earthing, and electrical protection for critical control and communication equipment.
Total of Design & Built cost (Part-A) Rs.1,995,715,746.38
SECTION – 7 : OPERATION AND MAINTENANCE
Operation and maintenance :
Deployment of manpower, supply of all chemicals, checking of status of supply in the command area, repairing of leakages, supply of fuel for generator, maintaining log book, submission of daily / weekly / monthly and yearly report of both RAW and Treated water quality , getting endorsed / tested by state laboratories once in every month, replacing the damaged parts of any machinery / the machinery as a whole, annual / bi-annual maintenance of all built-up / installed structures / units under the scheme , including round-the clock watch & ward and painting work on yealy basis for 60 calendar months (5 Years) from the date of completion of trial run. Note- Electricity Bill to be paid by the department
O & M cost for the first 12 calendar months Job 1.00 Rs.59,910,444.96 Rs.59,910,444.96
O & M cost for the second 12 calendar months Job 1.00 Rs.59,910,444.96 Rs.59,910,444.96
O & M cost for the third 12 calendar months Job 1.00 Rs.59,910,444.96 Rs.59,910,444.96
O & M cost for the fourth 12 calendar months Job 1.00 Rs.59,910,444.96 Rs.59,910,444.96
O & M cost for the fifth 12 calendar months Job 1.00 Rs.59,910,444.96 Rs.59,910,444.96
Total cost of O & M for 5 Years (Part-B) Rs.299,552,224.78
Total Cost of (A+B) Rs.2,295,267,971.16
Executive Engineer
P.H.Division Munger
TECHNICAL BID SHEET/ NIT NO.-11/MUNG/PHED/2026-27
Name of Work Surveying, Collection of Hydrogeological data, Design, Detailed Engineering, Construction, Supply, Installation & Commissioning of Surface Water based Multi-Village Piped Water Supply Scheme having 22 MLD WTP & Intake Well at Kharagpur Lake, Master ESRs (3 Nos), Zonal ESRs (17 Nos), UGRs & Pump Houses (06 Nos), Raw Water Pipeline, Clear Water Trunk & Distribution Network, Electro-Mechanical Works with SCADA System, and Allied Works with minimum 6 months of Trail Run and thereafter Comprehensive Operation & Maintenance (Excluding Electricity Payment) for next 60 Months in 14 Panchayat of H. Kharagpur and Tetiya Bamber Block (Named H. Kharagpur-Tetiya Bamber MVS) in areas having ground water Quality issues (Fluoride Contamination) under P.H. Division Munger for year 2026-27. Cost of Work as per BOQ(Rs in Lakhs) 22952.67971 Time of Completion in months 24 ALL COLOURED CELL TO BE FILLED ACCORDINGLY
Sactioned Amount As per Technical Approval Date of Tender 26.10.2026
Sl No. Items Requirement Requirement Cl. No.
Name of the Contractor
Address of the Contractor
1 Bid Validity Bids shall remain valid for a period not less than 180 days after the deadline date. A Bid valid for a shorter period shall be rejected by the Employer as non-responsive 180 Days 15.1 Bid validity periods In days
2 Bid Security (A) Online Mode EMD Amount. Amount To be entered (Rs in Lakhs)
(B) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given (If issued from any bank outside state will be converted to any bank within the state before executing the agreement. Amount To be entered (Rs in Lakhs)
Bid Security Amount - (Rs. In Lakhs) Bid Security Amount - Rs.
3 (i) Legal Status of Bidder. 4.3(a)
(ii) Place of Registration.
(iii) Principal place of Business
(iv) Power of attorney of signatory Bid Attached or Not 4.2(iv)
4 Total value of civil engineering construction work performed in last five years. 1. Annual Financial Turn Over in any one year during the the last five years to be not less than 50% of the estimated cost of works under the contract (Rs in Lakhs) 4.5A (a)
2021-22 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.47
2022-23 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.36
2023-24 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.26
2024-25 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.17
2025-26 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.08
5A Work Experience of Similar nature Satisfactory Completed as a Prime Contractor (or as nominated sub-contractor where the sub-contractor involved execution of all main items of work described in the bid documents provided further that all other qualifications criteria are satisfied) at least one similar work of value not less than 10% ( Ten Percent) (To be indexed at the rate of 8% for a year.) Value of the estimated cost of works for which the bid has been invited. Which includes Conventional Water Treatment Plant , Pump house , UGR , ESR , and Pipe Line Works. 4.5A (b) Amount To be entered (Rs in Lakhs)
6 Executed in any one year, the minimum quantities of the following item of work as indicated ,during last five years.
Items Unit Quantity executed 4.5A(c)
Conventional Water Treatment Plant MlD 11 MLD Value to be entered in unit Nos
Pipeline of Different Diameter DI Pipe HDPE Pipe Meter Meter 34915 Meter 174845 Meter Value to be entered in unit Nos
Elevated Service Reservoir (ESR) with Cumulative Capacity KL 7,475.0 KL Value to be entered in unit Nos
6.1 Operation and maintenance job comprising of Cumulative Projects works including Conventional Water treatment Plant of Cumulative capacity 11 MLD , Elevated service Reservoir, Underground Service Reservoir, and allied works done in last 5 years . Operation and Maintenance job Works Year 1 4.5A(c) Value to be entered in unit Nos
Bidding Capacity: More than the total Bid value of present work = A*N*3-B=Rs. ____.Where A = Maxm. Value of work executed in any one yr during last 5 yrs. N= Nos of years for completion of works. B=Value of existing commitments & ongoing works to be completed in period 4.7 Value to be entered in unit Nos
7 (a) Existing commitments and ongoing works Amount To be entered (Rs in Lakhs)
(b) Work for which Bid already submitted Amount To be entered (Rs in Lakhs)
8 Availability of key items of Contractor's Equipment Type of Equipment/Maximum age No. Required Nos. Max. Age 4.5(B) (a) Nos./ Max. Age
Concrete Mixer 3 5
Rotary Drilling / Reverse Rotary / DTH Rig Machine 2 5
Truck / Tractor with trailer 3 5
Hydraulic Excavator 2 5
9 Key Personnel Personnel/Qualification/Contract Package Size (work > Rs. 50 Crore) 4.5(B) (b) Name of the Personnel and Experince in years
Project Manager/ B.E. Civil + 10 Years Experience (5 years Manager in PHED Works or retaired EE & Above PHED) 2 no.
Site Engineer / B.E. Civil + 7 Years Experience (3 years Manager in PHED Works or retaired AE & Above PHED) 5 no.
Site superviser / B.E. Civil or Mech. + 05 yrs experiance or Diploma in Civil + 07 Years Experience or retaired JE & Above PHED) 12 no.
Surveyer B.E Civil + 03 Years Exp. Or Dip. Civil. + 5 Years Exp. 3 no.
10 Evidence of accesses to Financial Resources Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (Not more than 3 months old). (Rs in Lakhs). 4.2 (i) Amount To be entered (Rs in Lakhs)
11 Proposed methodology and programme of construction. Justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion as per milestones. (Attached or not)
12 Litigation History Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not)
13 Affidavit Regarding statements made in the required attachments are true and correct.
14 Undertaking Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. 25 % of B.O.Q.Amount
17 Character Certificate
18 Time of Completion 24 Months To be entered in months
QUALIFICATION INFORMATION
The information to be filled in by the Bidder in the following pages will be used for purposes of post qualification as provided for in Clause 4 of the Instructions to Bidders. This information will not be incorporated in the Contract.
NAME OF THE CONTRACTOR
1 For Individual Bidders
1.1 Constitution or legal status of Bidder (Attach copy)
Place of registration :
Principal place of business :
Power of attorney of signatory of Bid (Attach)
1.2 Total value of Civil Engineering construction work performed in the last five years** (in Rs. Million)
1.3.1 Work performed as prime contractor, work performed in the past as a nominated sub- contractor will also be considered provided the sub-contract involved execution of all main items of work described in the bid document, provided further that all oth
NAME OF THE CONTRACTOR
Project Name Name of the Employer* Description of work Contract No. Value of Contract (Rs. In Crore) Date of issue of work order Stipulated period of completion Actual date of completion* Remarks explaining reasons for delay & work completed)
* Attach certificate(s) from the Engineer(s)-in-Charge
** Immediately preceding the financial year in which bids are received.
Attach certificate from Chartered Accountant.
1.3.2 Quantities of work executed as prime contractor, work performed in the past as a nominated sub-contractor will also be considered provided the sub-contract involved execution of all main items of work described in the bid document, provided further that all other qualification criteria are satisfied (in the same name and style) in the last five years.
NAME OF THE CONTRACTOR
Year Name of the work Name of the Employer* Quantity of work performed
Remarks* (indicate contract Ref)
1.4 Information on Bid Capacity (works for which bids have been submitted and works which are yet to be completed) as on the date of this bid.
(A) Existing commitments and on-going works:
NAME OF THE CONTRACTOR
Description of works Place & State Contract No. Name & Address of Employer Value of Contract (Rs Cr) Stipulated Period of Completion Value of works* remaining to be completed (Rs Cr) Anticipated date of completion
* Attach certificate(s) from the Engineer(s)-in-Charge
The item of work for which data is requested should tally with that specified in ITB clause 4.5A ©
** Immediately preceding the financial year in which bids are received.
# Delete, if prequalification has been carried out.
(B) Works for which bids already submitted :
Description of works Place & State Name & Address of Employer Estimated value of works (Rs Cr) Stipulated period of completion Date when decision is expected Remarks, if any
1.5 Availability of key items of Contractor’s Equipment essential for carrying out the Works [Ref. Clause 4.5(B)(a)]. The Bidder should list all the information requested below. Refer also to Sub Clause 4.3 (d) of the Instruction to Bidders.
NAME OF THE CONTRACTOR
Description of works Requirement Availability proposals Remarks (from whom to be purchased)
No. Capacity Owned/Leased to be procured Nos./Capacity Age/ Condition
1.6 Qualifications and experience of key personnel required for administration and execution of the Contract [Ref. Clause 4.5(B)(b)]. Attach biographical data. Refer also to Sub Clause 4.3 (e) of instructions to Bidders and Sub Clause 9.1 of the Condition
NAME OF THE CONTRACTOR
Position Name Qualification Year of Experience (General) Years of experience in the proposed position
1.7 Proposed sub-contracts and firms involved. [Refer ITB Clause 4.3(k)]
NAME OF THE CONTRACTOR
Sanction of the works Value of Sub-contract Sub-contractor (Name & Address) Experience in similar work
Attach copies of certificates on possession of valid license for executing water supply/ sanitary work/ building electrification works [Reference Clause 4.5(d) & Clause 4.5(e)]
*1.8 Financial reports for the last five years: balance sheets, profit and loss statements, auditors' reports (in case of companies/corporation), etc. List them below and attach copies.
1.9 Evidence of access to financial resources to meet the qualification requirements: cash in hand, lines of credit, etc. List them below and attach copies of support documents.
1.10 Name, address and telephone, telex and fax numbers of the Bidders' bankers who may provide references if contacted by the Employer.
1.11Information on litigation history in which the Bidder is involved.
NAME OF THE CONTRACTOR
Other Party(ies) Employer Cause of Dispute Amount involved Remarks showing Present Status
1.12 Statement of compliance under the requirements of Sub Clause 3.2 of the instructions to Bidders. (Name of Consultant engaged for project preparation is ** ........................ …………….............................)
Proposed work method and schedule. The Bidder should attach descriptions, drawings and charts as necessary to comply with the requirements of the Bidding documents. [Refer ITB Clause 4.1 & 4.3(1)]
1.15 Quality Assurance Programme
2 Additional Requirements
2.1 Bidders should provide any additional information required to fulfill the requirements of Clause 4 of the Instructions to the Bidders, if applicable.
(ii) Undertaking
*** (iii) Update of original prequalification application
*** (iv) Copy of original prequalification application
*** (v) Copy of prequalification letter
* Delete, if prequalification has been carried out.
** Fill the Name of Consultant.
*** Delete, if prequalification has not been carried out.
Check List for Submission Of Tender
Evaluation will be done as per the information provided in the document attached with tender. Bidder may disqualified, if documents are not attached properly.
Name of the Bidder
Sl. No. Checklist Items (Attach Documents in Edit Attachment Folder) Document attached
1 BIDSECURITY PHOTO COPY
3 LAST 5 YEARS ANNUAL TURN OVER
4 EXPERIENCE Of SIMILAR NATURE Of W0RKS
5 QUANTITY OF WORK OF SIMILAR NATURE EXECUTED DURING LAST 5 YEARS)
6 BALANCE VALUE OF ON GOING WORKS
7 EXISTING COMMITMENTS
8 BANKER'S CERTIFICATE FOR ACCESS OF FINACIAL RESOURCES
11 LITIGATION HISTORY
12 PLANT and MACHINARIES
13 KEY PERSONNEL
14 Registration
15 Power of Attoney
16 Legal Status Of Bidder
17 PROGRAMME Of CONSTRUCTION
18 NOC FOR DEBAR
19 LABOUR LICENCE
21 ANY OF LAST THREE YEAR INCOME TAX RETURN
22 GST CERTIFICATE
23 Character Certificate
24 Any other Documens required as per NIT/ Standard Bidding Documents Required
IF YOU HAVE NOT BEEN DEBARED WRITE "NOT APPLICABLE" IN YOUR LETTER HEAD SCAN AND UPLOAD IN THE IN NOC FOR DEBAR LINK
Note:-Attachment should be self attested and should be attached as per above instruction, otherwise it may be rejected.
I, the undersigned, do hereby certify that all the statements made in the required attachments are true and correct.
Signature & Seal of the Bidder
TENDER NIT No.- 11/MUNG/PHED/2026-27
Name of The Work :- Surveying, Collection of Hydrogeological data, Design, Detailed Engineering, Construction, Supply, Installation & Commissioning of Surface Water based Multi-Village Piped Water Supply Scheme having 22 MLD WTP & Intake Well at Kharagpur Lake, Master ESRs (3 Nos), Zonal ESRs (17 Nos), UGRs & Pump Houses (06 Nos), Raw Water Pipeline, Clear Water Trunk & Distribution Network, Electro-Mechanical Works with SCADA System, and Allied Works with minimum 6 months of Trail Run and thereafter Comprehensive Operation & Maintenance (Excluding Electricity Payment) for next 60 Months in 14 Panchayat of H. Kharagpur and Tetiya Bamber Block (Named H. Kharagpur-Tetiya Bamber MVS) in areas having ground water Quality issues (Fluoride Contamination) under P.H. Division Munger for year 2026-27.
Date of Tender :- 26.10.2026
Estimated Cost (Including GST and O&M for 5 years ) :- Rs.2,295,267,971.00
Earnest Money :- Rs.22,952,680.00
Time of Completion (In Months) :- 24 Months
Cost of BSEDC Bid processing fee:- As Applicable (To be Online Paid)
Cost of BOQ :- Rs.10,000.00 (To be Online Paid)
Name and Address of the Bidder
Sl. No. Work Description Unit Qty. Rate in Rs. Rate in Word Amount in Rs
SECTION-1: RAW WATER SOURCE DEVELOPMENT AND TRANSMISSION
1 Designing constructing and commissioning Raw Intake well of required dia including deep cutting edge /curb (length of curb is over and above well depth and shall be plugged properly at bottom with provision of RCC Watta at periphery. The scope includes the construction of a coffer dam or temporary island enclosure to provide a dry and accessible working area by excluding water during the foundation and sub-structure construction. Alternatively, suitable barge/pontoon-based or any other approved method may be adopted depending on site conditions to facilitate safe and efficient foundation work. Well shall be constructed in min RCC Grade M30. Intake well shall be constructed by open excavation or sinking well method in all type of soil and strata with in tilted and shift under specified to lerance limit with neat well steining and smooth firm RCC raft for bottom platform Required Jetting, blasting, kenteledge etc. shall be inclusive in rate, each including providing & fixing suitable valve with sluice gate and road etc. complete. provision of vertical access (MS Ladder with safety Lines to be provided for regular maintenance and inspection works. Constructing pump house over intake well of required dia and required height above floor level suitable arrangement like machine foundation and maintenance ramps and spill channels for mounting Pumping machinery or any suitable machinery at plinth level platform for installation of electrical panel and other working facilities, providing all structural work of channel joints, doors, rolling shutters, windows etc. for ventilation and the item includes gentry girders with end carriage arrangement (EOT Crane) & access as per contractor's own design as per requirement. comp. The super structural work in brick masonry or RCC M30, including internal and external plastering in cement mortar (1:4/1:6) for intake well walls, gallery, and pump floor surfaces, followed by application of approved waterproofing treatment where required, and finished with two coats of epoxy-based or weather-resistant paint as per specifications. Well, steining shall be done as required inside the well. Rate inclusive of necessary diversion of course. (Design shall be approved by consultants appointed by Department). Approach road having appropriate length and appropriate inner clear width required as per site conditions & as per contractor's own design etc. complete of required size. Approach Bridge shall be constructed framed structure shall be constructed on piles with bracing beams arrangement, deck slab. All sub structure shall be of R.C.C. M-300 for Piles/ Column outside Water & M-300 for Piles/ Column in side Water with CRS steel reinforcement, Beams & Deck slab and Super structure shall be in Structural steel.
It shall be sufficient strong enough to take the load of M.S. pipe with water load, Trolley with dead weight of Pump, Pipes & painting with anti-corrosive paint and provided pipe roller support,bank protection of river Any Item remains to be mention above but required for the work shall be deemed to have been included. The above structure shall be provided with lighting protection devices. Necessary lighting/ electrification arrangement shall be made for whole structure. The bidder has to submit detailed Topographical, hydrological & geo technical survey of the site based on this survey.
For 22 MLD Intake Structure Job 1.00 Rs.0.00
2 Supply, Installation, Testing and Commissioning of following pumping sets suitable for duty as specified
2A Intermediate Raw water lifting pumps :
Duty: to deliver raw water to pre-settling tanks entry point having discharge not less than 600 cum per hour (167 LPS) against a head of 40m as per design - 3 nos (2 no. working + 1 standby) including 2 sets of vacuum pumps matching with the system, common suction manifold of diameter not less than 1500 mm of suitable length to accommodate water of minimum 3 minutes pump running time, sluice valves with actuators for valves, non-return valves, common delivery manifold, sluice, non-return valves, anti-surge pressure valves all complete. This item includes provision for 2 nos Vacuum pumps as necessary for smooth operation of raw water pumping sets including provision for adjustment of fluctuations in river water level all complete by variable frequency measures/ any other suitable arrangements. Job 1.00 Rs.0.00
2B Pre-settled Water lifting pumps
Duty : To deliver pre-settled water to Cascade aerator of Treatment plant , to be located in the raw water pump house adjacent to Pre-setting tank having discharge not less than 600 cum per hour (210 LSP) against a head of 20 M as per design - 3 nos ( 2 working + 1 stand by) common suction manifold of diameter not less than 1500mm of suitable length to accommodate water of minimum 3 minutes pump running time, sluice valves with actuators , non-return valves, common delivery manifold, sluice, non-return valves, anti-surge pressure valves all complete. Job 1.00 Rs.0.00
3 Approach Road: Development of all weather road of carriage width not less than 3.75m, and shoulder of 1.20m width from river bank to the point of PST including cost of earth and filling up to 1mt above highest water level, WBM work and carpeting all complete. PM 1600.00 Rs.0.00
SECTION-2: CONSTRUCTION OF WATER TREATMENT PLANT AND PRE-SETTLING TANK
1 Design, construction, (including topographical survey, geotechnical investigation and other surveys as required) for 22 MLD capacity of WTP based on 22/16 hrs. operation including inlet chamber, pre settling tank, pump house,aeration fountain / cascade, inlet channels including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and automated flow measuring arrangement, clariflocculator with conventional filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby, store house cum electrical and mechnical workshop sludge handling unit and recycling of collected water from sludge, clear water reservoir of specified capacity, clear water pumping station including specified number and capacity of pumps, motors, panels, starters, cables, transformers, panel room, etc. complete, external and internal electrification, laboratory building with all specified lab equipment, admin building, Quarter (One no.), sanitary block with necessary water supply and drainage arrangement, campus roads, landscaping, horticulture and other campus development works, rain water harvesting etc. all required works complete as per the direction of Engineer-in-Charge. Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. The design shall conform to IS / CPHEEO Manual. Job 1.00 Rs.0.00
SECTION-3 : CONSTRUCTION OF STORAGE FACILITY
1 Preparing structural design of RCC Under Ground / Partially under ground / above high ground level Reservoir of required capacity as per relevant I.S. standards and constructing the same, including excavation in all types of soil strata (including rock) including shoring strutting if required, for loose soil / to protect from collapse, casting 100 mm thick P.C.C. levelling course in M-15, Refilling the pit with proper soil and disposing of the surplus stuff at all lead. Including cement plaster in CM 1:2 with approved water proofing compound to all over inside container (i.e. walls, base, top slab/dome bottom etc. all). Including all types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design. Providing and fixing accessories, CI Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail. RCC chambers for valves. Providing and applying three coats of cement paint / snowcem to the out side face of structure. It also includes satisfactory water tightness test as per relevant I.S. code and painting name of scheme and capacity on the tank as per direction of engineer in charge. List of Indian Standards for Design of GSR / SUMP:- The structural design of GSR shall be in accordance with provisions relevant I.S standards - (1) I.S. 3370 part I & II 2009 or Its latest revision, (1.1) I.S. 3370 part III & IV 1965 or Its latest revision, (2) I.S. 456 – 2000 or Its latest revision., (3) I.S. 1893 – 2000 – 1984 or Its latest revision., (4) I.S. 875, Part – 1 to 3, 1987 or Its latest revision., General Specifications:- (1) Water depth in container shall be adopted as per data of tender. Capacity shall be calculated excluding free board of the reservoir. If water depth is not specified, the suitable water depth / acceptable to field engineer in accordance with hydraulic, (2) Shape of container (in plan) specified by in data shall be adopted in absence circular shall be adopted., (3) Size shall be fixed as per availability of space (land area) at site / acceptable engineer in charge., (4) Effect of overlapping of pressure bulbs on soil due near by structure and proposed sump should be considered, (5) Care shall be taken that no damage should occur to nearby existing structure. Compensation shall be paid for the same by agency, (6) The minimum concrete grade for RCC shall be M-30.,
(7) HYSD Fe 415 / 500 grade reinforcing bars confirming to I.S. 1786 / 1139 shall be considered in design. CRS / TMT bars shall be provided. In saline atmosphere corrosion resistance stainless steel / HCR rebar shall be provided. Any other steel can be used with approval of C.E./ in situation of non availability in market without extra cost. (8) Minimum size (or thickness) of various components shall be provided as per tender criteria / specifications in absence as per I.S./ Std. practice. Minimum dimensions specified for various components in tender data / specifications shall be provided without fail., (9) The safe bearing capacity (SBC) shall be referred from SBC test report. In absence of report it shall be referred from data sheet. If poor soil is found / water table is met with during excavation SBC shall be scientifically ascertained and design shall be revise. No extra shall be paid for increase in quantity., (10) DI pipes and special shall only be used if type is not specified in tender., (11) The rate shall include cost of dewatering during excavation making all arrangement when water table meets within depth., (12) The structure shall be designed properly to resist uplift due to ground water table specified in data or actual ground water table meets with during excavation. If GWT / Uplift is mentioned in tender and during excavation it dose not meet 7.5% rate shall be reduced., (13) SS pipes railing shall be provided over sump perifery when sump height is ≥ 1.5 meter above ground level., (14.a) RCC staircase/RCC Steps should be provided from GL to sump top slab based on the height of the GSR above/below the ground., (14.b) RCC Staircase with SS railing to be provided inside reservoir container. BB Masonry staircabin with MS safety door having locking arrangement to be provided for GSR, Sump and HGLR of capacity more than 7.5 Lakhs liter with top slab. If dome is constructed as top slab then provide minimum opening of 900 mm x 2000 mm with curbing and SS railing around. (15) Appearance of structure should be aesthetically good looking acceptable to authority., (16) Any change in size, shape, depth below GL, height above GL, water depth, F.B., size of member etc can be permitted in exceptional case due to site condition or hydraulic design requirement by C.E. No extra shall be paid for change., (17) Any change in data, dimensions, shape, water depth, reduction in size if permitted by competent authority and if it reduces quantity then payment shall be reduced prorate., (18) When capacity of GSR / Sump is > 20 lakh litres two or suitable compartments acceptable to executive engineer shall be designed and provided.,
(19) Agency shall engage qualified (at least graduate) consulting engineer for designing the structure and he / she shall visit the site for guidance of work., (20) 75% part rate shall be payable for concrete, reinforcement and plastering items of container until satisfactory hydraulic testing for water tightness is performed as per tender condition. Till the work shall be treated as incomplete.
At Treatment plant site of effective storage capacity of 4000 Cum Job 1.00 Rs.0.00
2 Design, detail engineering, soil investigation work, preparation of working drawing, Construction of RCC Master Elevated Service Reservoir a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.
p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
2.1 At Treatment plant site of storage capacity of 3800KL staging Height -25M Job 1.00 Rs.0.00
2.2 At IPS-1 site of storage capacity of 2250 KL stagin g Height -25M Job 1.00 Rs.0.00
2.3 At IPS-2 site of storage capacity of 850 KL staging Height -25M Job 1.00 Rs.0.00
3 Design, detail engineering, soil investigation work, preparation of working drawing, Construction of RCC Zonal Elevated Service Reservoirs at various locations under the command area of the project, of effective storage capacity as listed below,
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.
p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. Work Includes feeding of treated water from ESR to Existing 358 WLS & 39 Proposed WLS Schemes in command area.
3.1 200 KL capacity 18 M Staging in Ramankabad East Panchayat Each 1.00 Rs.0.00
3.2 400 KL capacity 18 M Staging in Manjhgain Panchayat Each 1.00 Rs.0.00
3.3 500 KL capacity 18 M Staging in Dariyapur-1 Panchayat Each 1.00 Rs.0.00
3.4 500 KL capacity 18 M Staging in Murade Panchayat Each 1.00 Rs.0.00
3.5 500 KL capacity 18 M Staging in Bhuna Panchayat Each 1.00 Rs.0.00
3.6 500 KL capacity 18 M Staging in Kesauli Panchayat Each 1.00 Rs.0.00
3.7 150 KL Capacity intermediate ESR, 18 M staging in Kesauli Panchayat Each 1.00 Rs.0.00
3.8 500 KL capacity 18 M Staging in Nonaji Panchayat Each 1.00 Rs.0.00
3.9 500 KL capacity 18 M Staging in Dhauri Panchayat Each 1.00 Rs.0.00
3.10 600 KL capacity 18 M Staging in Dariyapur-2 Panchayat Each 1.00 Rs.0.00
3.11 600 KL capacity 18 M Staging in Banhara Panchayat Each 1.00 Rs.0.00
3.12 150 KL Capacity intermediate ESR, 18 M staging in Banhara Panchayat Each 1.00 Rs.0.00
3.13 600KL capacity 18 M Staging in Ramankabad west Panchayat Each 1.00 Rs.0.00
3.14 700 KL capacity 18 M Staging in Gangta Panchayat Each 1.00 Rs.0.00
3.15 700 KL capacity 18 M Staging in Bangama Panchayat Each 1.00 Rs.0.00
3.16 150 KL Capacity intermediate ESR, 18 M staging in Bangama Panchayat, Each 1.00 Rs.0.00
3.17 800 KL capacity 18 M Staging in Tetia Panchayat - 1 No. Each 1.00 Rs.0.00
4 Preparing structural design of Zonal RCC Under Ground / Partially under ground / above high ground level Reservoir of following capacity as per relevant I.S. standards and constructing the same, including excavation in all types of soil strata (including rock) including shoring strutting if required, for loose soil / to protect from collapse, casting 100 mm thick P.C.C. levelling course in M-15, Refilling the pit with proper soil and disposing of the surplus stuff at all lead. Including cement plaster in CM 1:2 with approved water proofing compound to all over inside container (i.e. walls, base, top slab/dome bottom etc. all). Including all types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design. Providing and fixing accessories, CI Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail. RCC chambers for valves. Providing and applying three coats of cement paint / snowcem to the out side face of structure. It also includes satisfactory water tightness test as per relevant I.S. code and painting name of scheme and capacity on the tank as per direction of engineer in charge. List of Indian Standards for Design of GSR / SUMP:- The structural design of GSR shall be in accordance with provisions relevant I.S standards - (1) I.S. 3370 part I & II 2009 or Its latest revision, (1.1) I.S. 3370 part III & IV 1965 or Its latest revision, (2) I.S. 456 – 2000 or Its latest revision., (3) I.S. 1893 – 2000 – 1984 or Its latest revision., (4) I.S. 875, Part – 1 to 3, 1987 or Its latest revision., General Specifications:- (1) Water depth in container shall be adopted as per data of tender. Capacity shall be calculated excluding free board of the reservoir. If water depth is not specified, the suitable water depth / acceptable to field engineer in accordance with hydraulic, (2) Shape of container (in plan) specified by in data shall be adopted in absence circular shall be adopted., (3) Size shall be fixed as per availability of space (land area) at site / acceptable engineer in charge., (4) Effect of overlapping of pressure bulbs on soil due near by structure and proposed sump should be considered, (5) Care shall be taken that no damage should occur to nearby existing structure. Compensation shall be paid for the same by agency, (6) The minimum concrete grade for RCC shall be M-30., (7) HYSD Fe 415 / 500 grade reinforcing bars confirming to I.S. 1786 / 1139 shall be considered in design. CRS / TMT bars shall be provided. In saline atmosphere corrosion resistance stainless steel / HCR rebar shall be provided. Any other steel can be used with approval of C.E./ in situation of non availability in market without extra cost. (8) Minimum size (or thickness) of various components shall be provided as per tender criteria / specifications in absence as per I.S./ Std. practice. Minimum dimensions specified for various components in tender data / specifications shall be provided without fail., (9) The safe bearing capacity (SBC) shall be
referred from SBC test report. In absence of report it shall be referred from data sheet. If poor soil is found / water table is met with during excavation SBC shall be scientifically ascertained and design shall be revise. No extra shall be paid for increase in quantity., (10) DI pipes and special shall only be used if type is not specified in tender., (11) The rate shall include cost of dewatering during excavation making all arrangement when water table meets within depth., (12) The structure shall be designed properly to resist uplift due to ground water table specified in data or actual ground water table meets with during excavation. If GWT / Uplift is mentioned in tender and during excavation it dose not meet 7.5% rate shall be reduced., (13) SS pipes railing shall be provided over sump perifery when sump height is ≥ 1.5 meter above ground level., (14.a) RCC staircase/RCC Steps should be provided from GL to sump top slab based on the height of the GSR above/below the ground., (14.b) RCC Staircase with SS railing to be provided inside reservoir container. BB Masonry staircabin with MS safety door having locking arrangement to be provided for GSR, Sump and HGLR of capacity more than 7.5 Lakhs liter with top slab. If dome is constructed as top slab then provide minimum opening of 900 mm x 2000 mm with curbing and SS railing around. (15) Appearance of structure should be aesthetically good looking acceptable to authority., (16) Any change in size, shape, depth below GL, height above GL, water depth, F.B., size of member etc can be permitted in exceptional case due to site condition or hydraulic design requirement by C.E. No extra shall be paid for change., (17) Any change in data, dimensions, shape, water depth, reduction in size if permitted by competent authority and if it reduces quantity then payment shall be reduced prorate., (18) When capacity of GSR / Sump is > 20 lakh litres two or suitable compartments acceptable to executive engineer shall be designed and provided., (19) Agency shall engage qualified (at least graduate) consulting engineer for designing the structure and he / she shall visit the site for guidance of work., (20) 75% part rate shall be payable for concrete, reinforcement and plastering items of container until satisfactory hydraulic testing for water tightness is performed as per tender condition. Till the work shall be treated as incomplete.
4.1 At IPS-1 site at Panchayat Banhara of effective storage capacity of 2500 Cum Each 1.00 Rs.0.00
4.2 At IPS-2 site at Panchat Gangta of effective storage capacity of 1000 Cum Each 1.00 Rs.0.00
4.3 At Zonal IPS at Bangama panchayat of effective storage capacity of 200 Cum Each 1.00 Rs.0.00
4.4 At Zonal IPS at Banhara panchayat of effective storage capacity of 200 Cum Each 1.00 Rs.0.00
4.5 At Zonal IPS at Kesauli panchayat of effective storage capacity of 200 Cum Each 1.00 Rs.0.00
5 Clear water pumping sets:
5.1 Clear water pumping sets for Master ESR:
Design, detail engineering, procurement, supply, installation, testing and commissioning of Clear Water Pumping sets, preferably, horizontal centrifugal type, having rated discharge of 600 cum per hour capable of filling Master elevated service reservoir including motor having 25% margin over rated BHP, base plate, coupling, pipelines, common suction and delivery manifold, Non-return valves, sluice valves, instrumentation, MCC panels all complete, to be housed in clear water pump house. No of pumping sets = 3 ( 2 working and 1 stand- by). Job 1.00 Rs.0.00
5.2 Clear water pumping sets for Master ESR at intermediate pumping stations :
Design, detail engineering, procurement, supply, installation, testing and commissioning of Clear Water Pumping sets, preferably, horizontal centrifugal type, having rated discharge of 250 cum per hour capable of filling Master elevated service reservoir including motor having 25% margin over rated BHP, base plate, coupling, pipelines, common suction and delivery manifold, Non-return valves, sluice valves, instrumentation, MCC panels all complete, to be housed in clear water pump house. No of pumping sets = 3 ( 2 working and 1 stand by).At IPS-1 Job 1.00 Rs.0.00
5.3 Design, detail engineering, procurement, supply, installation, testing and commissioning of Clear Water Pumping sets, preferably, horizontal centrifugal type, having rated discharge of 90 cum per hour capable of filling Master elevated service reservoir including motor having 25% margin over rated BHP, base plate, coupling, pipelines, common suction and delivery manifold, Non-return valves, sluice valves, instrumentation, MCC panels all complete, to be housed in clear water pump house. No of pumping sets = 3 ( 2 working and 1 stand by).at IPS-2. Job 1.00 Rs.0.00
5.4 Design, detail engineering, procurement, supply, installation, testing and commissioning of Clear Water Pumping sets, preferably, horizontal centrifugal type, having rated discharge of 6.94 LPS (7.5 HP) capable of filling Zonal elevated service reservoir including motor having 25% margin over rated BHP, base plate, coupling, pipelines, common suction and delivery manifold, Non-return valves, sluice valves, instrumentation, MCC panels all complete, to be housed in clear water pump house. No of pumping sets = 2(1 working and 1 stand by).at Zonal IPS at Three locations. Nos 6.00 Rs.0.00
SECTION-4: MS PIPE, D.I PIPE & HDPE PIPE NETWORK.
A Raw Water Conveying Main Mipe.
1 Raw water conveying pipes: Pre-settled water conveying pipes- 700 mm dia MS pipe including laying , jointing, wrapping, coating and providing anchor block, thrust block, air valves, sluice valves, non-return valves all complete.
700 mm Dia, 10mm thk MS Pipe including corrosion Protection coatings. PM 5500.00 Rs.0.00
2 Providing and making inner cement mortar lining to M.S. Pipes with mechanical devices in cement mortar 1:1 proportion , including cost of all materials, labour, special sand required, machinery, power generation, all equipments, including carrying out "C" value performance test of pipeline, including field joints at site complete as per technical specification and direction of Engineer in In charge. . Sqm 12096.70 Rs.0.00
3 Providing and applying DFBE ( Dual Layer Fusion Bonded Epoxy) Coating to the external surface of M.S. Pipes conforming to Canadian Standard CSA Z 245.20-10, consisting of 1st layer of (FBE) Fusion Bonded Epoxy powder and 2nd layer also of FBE powder as Abrasion Resistant Overcoat (ARO) including preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2 including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Minimum thickness of coating shall be 600 micron. Sqm 27517.67 Rs.0.00
B Clear Water Rising Main
1 Surveying, leveling, designing of Clear water conveying main feeders considering filling time of each Zonal ESRs to be less than 4 hours simultaneously/ in segment -wise with a free fall head of not less than 2mt by using software -simulated program with C value = 100, preparation of route drawing showing road crossings, position of ESRs , terminals points of each pipe up to location to be confirmed by E-in-C within the command area of the project, procurement of Ductile Iron pipe K9 category , supply , unloading at locations of laying, supply of fittings and fixtures including isolating sluice valves, air valves, scour valves, laying, jointing, testing of pipelines, construction of valve chambers, and commissioning of the network to the satisfaction of E-in- C all complete.
250 mm diameter DI K-9 Pipe PM 9295 Rs.0.00
300 mm diameter DI K-9 Pipe PM 15717 Rs.0.00
350 mm diameter DI K-9 Pipe PM 5264 Rs.0.00
400 mm diameter DI K-9 Pipe PM 7749 Rs.0.00
500 mm diameter DI K-9 Pipe PM 8796 Rs.0.00
600 mm diameter DI K-9 Pipe PM 12272 Rs.0.00
700 mm diameter DI K-9 Pipe PM 5236 Rs.0.00
C Distribution Main (Zonal ESR TO WLS Water Tank)
1 Survey, Design, Providing, laying, Jointing & field testing of High Density Polythenepipes, (HDPE) conforming to IS 4984/14151/12786/13488 with necessary jointing material line mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with jacks/hydraulic jacks/ But fusion machine, (50mm & above fusion jointed & below 50mm mechanical jointed). It includes fittings i.e gate valves, sluice valves and other required materials to complete the connection to existing WLS Schemes.
63 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.1) PM 44322 Rs.0.00
75 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.2) PM 28315 Rs.0.00
90 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.3) PM 87200 Rs.0.00
110 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.4) PM 55710 Rs.0.00
125 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.5) PM 31335 Rs.0.00
140 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.6) PM 29783 Rs.0.00
160 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.7) PM 23098 Rs.0.00
200 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.8) PM 22960 Rs.0.00
250 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.9) PM 15980 Rs.0.00
315 mm diameter HDPE Pipe, PE-100, PN-10 (Sub Estimate No-4.10) PM 10987 Rs.0.00
2 Providing house connection for new and left out house hold in existing schemes including supplying all materials, labours, tools and making ferrule connection with 20 mm dia with all fittings etc all complete. Nos. 13100 Rs.0.00
3 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.
300 mm Dia 8 mm thick casing pipe. Rmt 220 Rs.0.00
400 mm Dia 8 mm thick casing pipe . Rmt 180 Rs.0.00
600 mm Dia 10 mm thick casing pipe . Rmt 20 Rs.0.00
700 mm Dia 10 mm thick casing pipe . Rmt 40 Rs.0.00
4 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : For Sluice Valve
100 mm Dia. Nos. 51 Rs.0.00
150 mm Dia. Nos. 42 Rs.0.00
200 mm Dia. Nos. 26 Rs.0.00
250 mm Dia. Nos. 17 Rs.0.00
300 mm Dia. Nos. 11 Rs.0.00
400 mm Dia. Nos 6.00 Rs.0.00
5 Constructing masonry Chamber 120x120x100 cm( Depth Upto pipe invert level) inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S ( non modular) bricks of class designation 100 A. Nos. 153.00 Rs.0.00
6 Reparing of Existing House service connection including excavation, supply of required MDPE pipes, taps, etc complete for proper completion of work. Nos. 2400.00 Rs.0.00
7 Repairing of Existing House Connection in case leakage at Ferrule including excavation, supply of required MDPE pipes, taps, etc complete for proper completion of work. Nos. 3450.00 Rs.0.00
8 Strengthening, repairing, painting, replacing of required steel and GI sheets(including supply of steel and sheets) for pump house and Existing steel staging of 8m height making the structure in good working condition and repairing of tank if required etc complete for proper completion of the work. Nos. 74.00 Rs.0.00
SECTION-5: DEVELOPMENT WORK
1 Development of land by raising with locally available sandy soil unto Finished ground level which is to be determined at least 500 mm above Finished GL. Cum 9000.00 Rs.0.00
2 Design , detail engineering, preparation of drawings, construction of Boundary wall along the property line of height not less than 1500 mm above finished ground level. (WTP Area, Intermediate Pumping Station & ESR. PM 3600.00 Rs.0.00
3 Design , detail engineering, preparation of drawings, construction of RCC two-storied twin type Staff quarters having 200 sqmt plinth area per floor and Admin Building 320 Sqmt. Etc. all complete as per directions of Engineer-in-charge. Job 1.00 Rs.0.00
4 Providing & Fixing Iron gates for compound wall of required size & specification as per the drawings to be submitted with 2 No of R.C.C. column size 0.45 x 0.45 m ( including reinforcement) with 15 mm thick cement plaster to all exposed surface including excavation in all strata, P.C.C., form work for R.C.C. work , painting to all Iron exposed surfaces( incl. brusing , cleaning & priming coat ) and cleaning the site etc. the site etc. complete. ( WTP Location -1 Nos., IPS Location - 5 Nos, Zonal ESR Locatoion - 17 Nos.) Each 21.00 Rs.0.00
SECTION-6 :ELECTRICAL WORK
1 Power connection, External and Internal illumination
Design, detail engineering, procurement, supply, fitting, fixing of electrical works for internal and external lighting in the treatment plant complex, zonal ESRs , including supply of MS Electric poles, all cables, transformers, MCC panels and other accessories as required all complete including external and internal illumination as per IE rules as necessary as well as getting power connection from BSEB for the WTP complex and all the electrical works from the sub-station point onwards etc all complete. Job 1.00 Rs.0.00
2 Extra for additional route length of HT transmission line from BSES sub Station to WTP area. KM 1.00 Rs.0.00
3 Electrical back-up facility
Provision for 300 KVA Diesel generator Nos. 2.00 Rs.0.00
4 Solar Panel :
Provision for Solar lights for external and emergency internal illumination in Water Treatment Plant complex, Zonal ESRs, compound lighting, staff quarters, compound lighting etc as per approval LS 10.00 Rs.0.00
5 Automation and SCADA facility
Design, supply, installation, testing, and commissioning of instrumentation equipments for raw water and clear water pumping stations. The scope includes the supply and installation of all necessary instrumentation devices such as pressure gauges and pressure transmitters on delivery and header pipes, ultrasonic level transmitters for level measurement of all ESRs & WLS Tanks, level switches, float and board type level indicators, full bore electromagnetic flow meters, PLC panels, and Fully automated SCADA system. The work also includes laying of all required instrumentation cables, termination, and associated accessories, along with all allied instrumentation works, complete with necessary hardware and supports. All works shall be executed as per approved design and drawings, relevant standard specifications, and as directed by the Engineer-in-Charge. job 1.00 Rs.0.00
The SCADA system shall integrate the field-level instrumentation and control equipment at all project locations through PLCs, RTUs, or equivalent controllers. Communication between remote facilities and the central control room may be established through suitable media such as optical fiber, Ethernet, radio, or cellular communication, depending on site conditions and network availability. The proposed architecture shall generally comprise: Field instrumentation: Flow meters, level transmitters, pressure transmitters, water quality analyzers, and equipment status signals. Local control panels: PLC/RTU panels, motor control interfaces, signal conditioning, and local operator controls. Communication network: Industrial communication equipment and protocols suitable for reliable data exchange between remote stations and the central control room. Central SCADA system: Supervisory software, operator workstations, data logging, alarm management, trends, and reporting. Power backup and protection: Suitable UPS, surge protection, earthing, and electrical protection for critical control and communication equipment.
Total of Design & Built cost (Part-A) Rs.0.00
SECTION – 7 : OPERATION AND MAINTENANCE
Operation and maintenance :
Deployment of manpower, supply of all chemicals, checking of status of supply in the command area, repairing of leakages, supply of fuel for generator, maintaining log book, submission of daily / weekly / monthly and yearly report of both RAW and Treated water quality , getting endorsed / tested by state laboratories once in every month, replacing the damaged parts of any machinery / the machinery as a whole, annual / bi-annual maintenance of all built-up / installed structures / units under the scheme , including round-the clock watch & ward and painting work on yealy basis for 60 calendar months (5 Years) from the date of completion of trial run. Note- Electricity Bill to be paid by the department
O & M cost for the first 12 calendar months Job 1.00 Rs.0.00
O & M cost for the second 12 calendar months Job 1.00 Rs.0.00
O & M cost for the third 12 calendar months Job 1.00 Rs.0.00
O & M cost for the fourth 12 calendar months Job 1.00 Rs.0.00
O & M cost for the fifth 12 calendar months Job 1.00 Rs.0.00
Total cost of O & M for 5 Years (Part-B) Rs.0.00
Total Cost of (A+B) Rs.0.00
Note:- Bidders are required make the entries in the coloured cells only..
Executive Engineer
P.H.Division Munger
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-11_2026-27.pdf
NIT • 2.44 MB
Newspaper cutting NIT-11_2026-27.pdf
NIT • 1.26 MB
SBD NIT-11_2026-27.pdf
NIT • 1.75 MB
BOQ MVS KHARAGPUR (2).xlsx
NIT • 0.26 MB
TECHNICAL Bid mvs ok.xls
NIT • 0.15 MB
Corrigendum nit.11_2026-27.pdf
NIT • 0.35 MB
Financial bid NIT-11_2026-27.xlsx
NIT • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .