| 1 | L1₹36.3 LAccepted-AOC | ₹36.3 L | L1 | Accepted-AOC AOC accepted. |
| 2 | L2₹37.1 L+₹84,952 (2.34%)Rejected-AOC FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | ₹37.1 L+₹84,952 (2.34%) | L2 | Rejected-AOC AOC Rejected. |
| 3 | L3₹38.0 L+₹1.7 L (4.65%)Rejected-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | ₹38.0 L+₹1.7 L (4.65%) | L3 | Rejected-AOC AOC Rejected. |
| 4 | L4₹39.5 L+₹3.2 L (8.86%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹39.5 L+₹3.2 L (8.86%) | L4 | Rejected-AOC AOC Rejected. |
| 5 | L5₹40.1 L+₹3.8 L (10.5%)Rejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹40.1 L+₹3.8 L (10.5%) | L5 | Rejected-AOC AOC Rejected. |
Tender Value
Refer Docs
EMD Value
₹94,600
Closing Date
21 Jun 2021, 6:00 pmClosed
GE DEHRADUN
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Manning and operation of Polo Pump House, Cheerbagh Pump House and certain repair/ replacement of E/M water supply installation under AGE E/M-I of GE Dehradun .
2021_MES_438007_2
8284/A/E8
Open Tender
Civil Works
Item Rate
334 days
GE DEHRADUN
Class D Cat d (v)
7 documents required · 7 mandatory
₹500
GE DEHRADUN
₹94,600
Yes
24 Aug 2021
7 Jun 2021
23 Jun 2021
7 Jun 2021
21 Jun 2021
7 Jun 2021
Amount
Manning & Operation including maintenance of Polo Pump House with trained man power consisting of Centrifugal Pump Set - 03 Nos, Submersible pump set 02 Nos including One bore well, Chlorine Plant, DG Set, Valves and its accessories, electrical panels, starters etc on the following requirements :- (a) The pump house will be operated with one operator (Skilled) in each shift for three shifts in a day including Sunday & holidays. (b) Proper recording of all operating parameters in the prescribed log book/Register will be done all as directed. (c) The work includes operation of centrifugal Motor/Pump sets, Submersible Pump Set, Chloronome Plant, DG Sets, routine maintenance of machinery, distribution of water as directed, cleaning of area etc as per direction of Engineer-in-charge. (d) Successful operation of the plant at the entire satisfaction of GE is sole responsibility of contractor. (e) Operator will be responsible for timely collection of Disinfectant chemical, POL, Engine oil from MES store yard as and when required. (Total No of units=01 installationx334 daysx03 shifts=1002)
Manning & Operation of sluice valves at water supply installations, over head water tanks including water supply net work with one experienced valve man in one shift including sundays and holidays as directed by Engineer-in-Charge at Beacher Road area. Note:- The valve man will operate the valves of OHT/installations and the valve's of the distributions network of the particular area at the timings of the water supply as directed by Engineer-in-charge. (Total No of units=01 installationx334 daysx01 shifts=334)
Operation and Maintenance of Cheerbagh Tubewell and 331 Med pump house with trained man power consisting of Tube well , chlorine plant / chemical dosing plant, DG set, valves and its accessories on the following requirements:- (a) The Tube well and pump house shall be operated with one No operator (skilled) in each shift for two shifts in a day including holidays and sundays. (b) Proper recording of all operating parameters in the prescribed log book/ register shall be done all as directed. (c) The work includes operation of Tube well, chloronome plant, DG set, routine maintenance of machinery, distribution of water as directed, cleaning of area etc as per direction of EIC. (d) Successful operation of the plant to the entire satisfaction of GE is sole responsibility of contractor. (e) Operator will be responsible for timely collection of chlorine gas cylinder, POL, Engine oil from MES store yard as and when required. (f) The work includes cleaning of pump house area, maintaining of pump house premises as per direction of EIC. (g) ) In case of power break down the contractor will liaise MRS to restore the power supply for running of plants. (Total No of units=01 installationx334 daysx02 shifts=668)
Providing manpower one pipe filter skilled to attend external water supply day to day complaints received at following complaints cells including sunday & Holidays. (a) Beacher Road complaint cell -01 No pipe fitter (skilled) for one shift. Timing 0900hrs to 1700hrs (Total No of units=01 installationx334 daysx01 shift=334)
Notes for item 01 to 04:- (i) The Contractor shall be liable to pay wages not less than minimum wages as notified by Government of India/ concerned State Government /Local Body, whichever is higher and applicable rates for contribution of employer towards EPF, contribution to ESIC, contribution of Bonus and LWC under labour laws. (ii) The prevailing rate/wage/contribution shall be as applicable on the bid submission end date.
(a) The installations includes operation of centrifugal pump sets, motor, Chlorine Plant, DG Sets and other machines/ equipments, valves etc as mentioned above and installed at site, routine maintenance of machinery, distribution of water for the period / shifts as specifid in the Items as per direction of Engineer-in-Charge. (b) The contractor shall employ ITI qualified Electrician with 5 years experience to operate the respective installations. Valveman having adequate experience to operate the above said system shall be deployed under respective item. (c) The operators deployed shall be well conversant with operation of installations and plant and shall be responsible for any normal maintenance of existing installations including DG sets. (d) Operators shall be responsible for proper recording of all operating parameters and test results in the prescribed log sheet /register all as directed by Engr-in-Charge.
(e) In case of absence of an operator during a shift, payment of that shift shall not be made. (f) In addition to deduction of payment as above a panelty of Rs. 1500/- per shift shall be levied for absent period. (g) The rates quoted by the contractor shall include employment of a reliever as per labour law and nothing extra shall be paid on this account . (h) Contractor will be responsible for timely collection of chemicals, POL, Engine Oil from MES Store Yard as and when required. (j) The rate also include regular greasing and oiling of pump sets, motors gland packing for pump sets. However, other repairs/maint store required shall be measured and paid separately. The contractor shall be responsible for the complete security of the plant including necessary watch and ward, maintenance of garden lawn etc.
Supply & fixing of lead acid battery 12 Volts, 180 AH including 02 duly initial charging of the battery and fixing to its position complete all as specified and directed. Make : EXIDE/CHAMPION/AMARON
Supply only Calcium Hypo Chlorite having 65%-70% Chlorine Content (Calcium based granular disinfectant) for general water treatment & swimming pool water treatment, in factory sealed container/drum (45 kg packing), complete all as specified and directed. Calcium Hypochlorite detailed specifications : (a) Chemical analysis & physical observations : Description : Whitish granules Granular size (Mesh passing through - 100 BSS): 1.1(+ 0.1)% Water/moisture : < 5.00% Mercury & other Heavy Metal contaminants : BDL. (b) Strength in terms of quantity of chlorination chemical required to obtain free chlorine of 1 ppm per lakh liters of water: Requirement must be 140-200 gm per one lakh liter of water to achieve 1 ppm Average at injection point (site & raw water quality variations may apply additionally). Make: Royal Seema/Grasim/Delibac.
S&F in replacement water pressure gauge glycerin filled of size 100 mm 0-7 kg/cm2 complete all as specified & Directed.
M&L for chequer LT rubber insulation matting sheet suitable for 11000 volts 3 mtr x 1 mtr x 10mm thick as per standard specification all as directed.
M&L MS Chequered plate 7 mm thck. in size including cutting fabricated cold or hot welding at site drilling holes nuts - bolt and washers etc including angle iron 65 mm x 65 mm x 6 mm thick for mounting of MS sheet cover dully painted with black bituminous paint over one coat of red oxide primer and as directed. including breaking of existing duct for grouting of angle iron, and making good Pcc of the existing duct , at water supply installation all as specifid and directed.
Taking up or down MS pipe of flanged ends joint type from trenches including dismentling & removing for disposal for the pipes of 200 mm bore complete all as specified and directed.
Material and labour MS ERW steel pipe 5.0 mm thick of 300mm dia including necessary welding works Make : Jindal/TATA/Prakash
Material and labour MS flange min 8 mm thick of 300mm dia duly drilled holes including welding in plain end of MS pipe with one rubber gasket .
Material and labour for nut bolt and washers of any size as required and directed by Engr- in - charge.
Material and labour for PCC 1:3:6 type CI, using 20mm graded stone aggregate anchor blocks under line at the bends, slopes, pipe supports and at the dead ends to resist static/dynamic thrust loads developes during the running of water main line, including necessary form work and fair finishing to exposed surfaces without using extra cement complete all as specified
Dismantling existing foundation and Material and labour for PCC 1:2:4, Type B2, using 20mm grade stone aggregate for foundations of pumping sets, motors etc complete including disconncting and opening, taking out to existing motor/ pumping sets and breaking/ demolition of old foundation of any size all as directed at site, specification complete, making good to all adjacent disturbed area as aper existing specification, supply and fixing of foundation bolts of high tensile strength with nuts, washers complete 4 sets and re-fixing of existing pump sets/motors at their original location, re-connecting and testing, including necessary form work and fair fixishing to exposed surfaces without using extra cement complete all as specified
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using using galvanised iron strip 25x4mm as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed.
S&F LED decorative post top lantern for Garden light 40 watt5700K IP 65 protection resistance to impact and corrosion glare, free and better uniformity milky version as per Crompton cat part No LPTO40CDL/M/ Bajaj model No. BGCl40W-LED-WH and Havells -LHEVBHP7PN6K040 including taking down old unserviceable post of lantern complete with fixing arrangement and connecting testing complete as directed.
Material and Labour greased graphite gland packing of verious size (6mm , 8mm, 10 mm, 12mm), as required at site complete all as specified & directed. Make :- Champion
Disconnecting and taking out defective battery lead and supplying, fixing, connecting and testing battery lead (Heavy duty) PVC insulated with multi strand copper conductor single core of size 25 Sqmm for 2 metre length including one side fixed with brass/ copper eye hole lugs clamp and other side fixed with brass battery terminal of heavy duty complete all as specified and directed.
Supply and fixing 25 Sqmm, 3 Core, flate PVC insulated, submersible cable, PVC sheathed with multi-stranded copper conductors, conforming to IS : 694- 1990 of 1100 Volt grade, all as specified and directed by Engineer-in-Charge. (Make Finolex / Havells / Incab / Nicco/ National/ Plaza/ Polycab )
M&L for dismantling electrically and taking down unserviceable fully automatic starter any type dry/ ATS type, from base frame and transporting to workshop for cleaning and refixing the serviceable parts back after repair and replacement of U/s parts for the 50.0 HP to 80.0 HP capacity size. (Note: Spare parts required for replacement shall be measured & paid for separately under respective item).
Supply only following spares of fully automatic starter:-
Fixed power copper contacts suitable for 75 HP/100 HP star delta starter.
Moving power copper contacts suitable for 75 HP/ 100 HP star delta starter.
Auxiliary switch type -01 with 1 No-1 NC suitable for 60/80 HP star delta starter.
RZ timer with coil & time delay range 3-12 seconds suitable for 60/80 HP starter.
Mini motor Protection relay protections for Thermal overload, Earth fault, Locked rotor, single phasing, current unbalance, phase sequence reversal and under current. Make L&T
S&F cast iron 'D' joint set complete of two flanged collar one no sleeve two nos rubber 'O' ring and nut bolts washers of suitable size for 150 mm bore CI/DI/HDPE pipe complete including necessary cutting, grinding work to fix in pipe as directed. (Note:- Earth work required to clear the pipe shall be measured and paid separately)
Taking down centrifugal pump from base frame including disconnection from coupling, make Kirloskar of discharge capacity 180 cum/hr at 70 mtr head installed at pump house and supply and fixing Centrifugal pump split casing type discharge 180 cum/hr at 70 mtr head complete with CI impellars ,SS shaft ,sleeves ,bushings ,bearing ,bearing housing ,neck ring ,center ring ,key for shaft ,key for coupling ,gland packing or any other spare of standard assembly set of OEM,incl necessary welding machine grinding work required at the time of refitting of assembly with existing induction motor, any nut bolt washer required and refixing of the same by reassembling on base plate with proper alignment with motor and testing on full discharge complete all as specified and directed .Note:- (i) The item rate shall be deemed to be inclusive of required spares, any machining work
Material and labour for MS work for pump set foundation , any type of structural steel sections, nut- bolt, washers, sheets, back plate, xpm mesh, wire mesh, bending, cutting in shape, welding, drilling holes, flanges including painting with two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Supply only in replacement 480 mm long telescopic pole extended up to 900 mm made of aluminum tubing with butterfly net as per sample
M&L for excavation in trenches in any type of soil not exceeding 1.5 Meter wide and not exceeding 1.5 Meter deep including cutting in slopes etc for laying of pipe line including getting out, complete all as specified and directed.
M&L for returning, filling in, including spreading, leveling, watering and well ramming in layers in soft / loose soil not exceeding 25 cm in each layer complete all as specified and directed by Engineer-in-Charge.
M&L for removal of excavated material (Soil) to a distance up to 50 Meter from starting point and depositing where directed at level not exceeding 1.5 Meter above as directed by Engineer-in-Charge.
Supply & fix in repair high density polythene pipe (HDPE) of 150 MM dia presure rarting 10 kg/sqcm ISI marked laid in trenches complete with all fittings required at site. Note : (i) Cost of the all jointing material & fittings such as Tee, Bend, Socket etc are included in the cost of item rate. Make : Polytuf/ Supreme/ Jindal/ Bharat Polymers/ Jack pipes.
Dismantling unserviceable LT Panel and Supply, installation, testing and commissioning in replacement of LT panel board, CPRI approved, cubical type 440 Volts 3 phase 4 wire indoor type front and back operated with adequate air ventilation at both sides & back, fabricated out of 3.15 thick CRCA sheet, water proof dust & vermin proof, pre fabricated hinges for rear & front door with locking arrangement complete with inter connection with copper wire / strip, tapping bonding to earth & all frames, inner & outer door shall be coated by polyster powder paint of shade RAL 7032 siemens grey, stand of distribution board shall be coated by primer & black bituminous paint, cable trays, cable lugs, cable glands, nut, bolt, washer etc of required size, provision for taking out cable duly marked / rivetted letters of appropriate size for each feeder cable & reconnection with duly insulated cable terminals with heat shirnkable sleeve with 1.1 KV grade danger notice board etc. including supply and fixing of the following Switch gears / ACB/ MCCBs /change over switch/ Fittings & Fixtures. The size of panel board shall be as per manufacturer's recommendation to accomodate following Switch gears / ACB/ MCCBs / Fittings & fixtures:- Make of Panel : L&T/Shalabh India Ltd/Universal switchgear control/IT Gurgaon/HPL/C&S/Havells. Note : Drg of panel shall be approved by GE before procurement of panel.
(i) Bus bar chamber consisting four Nos copper busbar of capacity 800 Amp & 600 Amp for neutral duly insulated with heat shrinkable sleeve 1.1 kv grade with RYBN mounted on heavy duly epoxy insulator in separate compartment. (ii) LED indicating lamp (RYB) for incoming and outgoing feeder controlled with 2 Amp MCB single pole 'C' curve. (iii) Panel board internal wiring with suitable PVC insulated multistranded copper conductor flexiable cable heavy duty 1.5 time of MCCB rating upto 100 Amps and solid connection with suitable size strip for MCCB's rating above 100 Amps.
(v) INCOMINGS (a) MCCB 415 Volts, 500 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 35 KA (Ics=100%Icu)- 1 Nos. Make C&S/L&T/Legrand. (b) Change over switch 400 Amps cat No. 1HCNFE0200 Make : Havells/ L&T/ Legrand.
(vi) OUTGOINGS (a) MCCB 415 Volts, 400 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 35 KA (Ics=100%Icu)- 1 Nos. Make C&S/L&T/Legrand. (b) MCCB 415 Volts, 250 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release, (Service Breaking Capacity 25 KA (Ics=100%Icu)-02 Nos. Make C&S/L&T/Legrand . (c) MCCB 415 Volts, 200 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 25 KA (Ics=100%Icu)- 1 No. Make C&S/L&T/Legrand.
(d) MCCB 415 Volts, 63 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 16 KA (Ics=100%Icu)-1 No. Make C&S/L&T/Legrand. (e) Star delta Starter suitable for 150 HP motor -01 Nos with Mini motor protection relay protections for Thermal overload, Earth fault, Locked rotor, single phasing , current unbalance, phase sequence reversal and under current. Make : L & T/ Legrand. (f) Star delta Starter suitable for 100 HP motor -01 Nos with Mini motor protection relay protections for Thermal overload, Earth fault, Locked rotor, single phasing , current unbalance, phase sequence reversal and under current. Make : L & T/ Legrand. (g) Star delta Starter suitable for 50 HP motor -01 Nos with Mini motor protection relay protections for Thermal overload, Earth fault, Locked rotor, single phasing , current unbalance, phase sequence reversal and under current. Make : L & T/ Legrand.
All as per item No 31 here in above but including supply and fixing of the following switches gears/ ACB/ MCCBs/ Fittings & Fixtures.
(i) Bus bar chamber consisting four Nos copper busbar of capacity 200 Amp & 200 Amp for neutral duly insulated with heat shrinkable sleeve 1.1 kv grade with RYBN mounted on heavy duly epoxy insulator in separate compartment. (ii) LED indicating lamp (RYB) for incoming and outgoing feeder controlled with 2 Amp MCB single pole 'C' curve. (iii) Panel board internal wiring with suitable PVC insulated multistranded copper conductor flexiable cable heavy duty 1.5 time of MCCB rating upto 100 Amps and solid connection with suitable size strip for MCCB's rating above 100 Amps.
(iv) INCOMINGS (a) MCCB 415 Volts, 200 Amp, rating 4 Pole (triple pole and neutral), adjustable Thermal Magnetic release (Service Breaking Capacity 35 KA (Ics=100%Icu)- 1 Nos. Make C&S/L&T/Legrand.
(e) Star delta Starter suitable for 75 HP motor -01 Nos with Mini motor Protection relay protections for Thermal overload, Earth fault, Locked rotor, single phasing, current unbalance, phase sequence reversal and under current. Make L&T/Legrand (f) Automatic/ manual change over switch 200 Amp four pole, AC-31A 50Hz 415 Volt item code IHYFCDO200. Make : Havells or equivalent make of L & T/ Legrand. (g) Taking out existing SCADA system from old panel and refixing the same in the new panel with making necessary fixing arrangements and testing complete all as specified and directed by Engr -in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft soil.
M&L for 75 mm thick cement concrete 1:4:8 type D2 (40 mm graded stone aggregate) in sub base to floors finished fair and even complete all as specified and directed.
M&L for 40 mm thick cement concrete 1:2:4 type B2 (40 mm graded stone aggregate) in sub base to floors finished fair and even complete all as specified and directed.
M & L 60mm thick precast concrete rubber moulded coloured machine pressed interlocking paver block any shape and size confirming to IS 15658-2006 of, M-35 Grade laid over and including sand bedding 20 mm thick complete all as specified and directed Make : usha/Tulip/NTC.
Dismantling/taking out defective sluice valve from the existing pipe lines by opening/cutting corroded Nuts/bolts, removing of packing etc. complete and Supply and fixing CI sluice valve both end flanged dully drilled for both ends with stainless steel spindle, hand wheel and nuts, stuffing box etc. Type PN-1.6, ISI marked of following sizes :- Make: Kirloskar/Zoloto/Kartar
(a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
Disconnecting the existing non functional submersible pump set from electric supply from panel, dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity & in any position, alongwith existing column pipe 100mm dia and existing submersible cable of any size from the bore well ( up to 450 feet depth of pump set from GL) and staking the pump and column pipes near by the bore well for inspection complete all as specified and directed by Engineer-in-Charge. NOTE : (i) Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. (ii) Number of column pipe may vary from 30 to 40, The existing pipes & flanged joints shall be checked for its serviceability & unserviceable joints alongwith flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new flange joint, the cost of same shall be deemed to be included in the quoted rate for above item. However cleaning of pipes and new MS flanges if any required shall be measured & paid separately.
Dismantling and strip opening of submersible pump & motor of any description and in any position for servicing /overhauling mechanically and electrically, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, welding , etc of broken steel sections of pump, reassembling the Pump & motor, ensuring proper alignment of pump and motor, connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for 40 to 75 HP capacity, 3 phase, 415 volts, 50 HZ, AC supply pumps & motors of make KSB/SU/CALAMA/KIRLOSKAR.
Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under these items. (ii) Burnt out windings of motor shall be replaced, measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) (a) The rates for above items are deemed to include transportation to & fro of pumps/ motors to workshop for necessary repairs. (b) The rate quoted for the item shall include re-metaling of Pump shaft, polishing and grinding and making standard size to match with Bush/Neck-ring/ sleeve etc (iv) Lifting of pump and motor from bore well and lowering of pump and motor after repairs shall be measured and paid separately under appropriate item of Schedule `A' (v) The quoted rate shall be deemed to include replacement of small/ minor parts i.e. washers, keys for coupling, cable packing ring etc.
Supply only the following items / spare parts suitable for AC submersible pump set of 75 HP capacity dismantled under Sch ‘A’ item No. 38 above all as specified and directed by the Engineer-in-Charge.
GM bush bearing.
Neoprene rubber bush for stage bowl.
Stain less steel sleeve.
S/S stud with nut for stage bowl
Impeller Key
GM impeller
Motor pump coupling made out of stain less steel with key.
Stage bowl
Anti magnetic stainless steel pump shaft with key Make :- DD/ KSB or equivalent approved
Strainer stainless steel
Supply only the following items / spare parts suitable for Motor of AC submersible 75 HP capacity dismantled under Sch ‘A’ item No. 38 above all as specified and directed by the Engineer-in-Charge.
S/S upper sleeve.
S/S lower bush.
upper bush rubber.
Lower bush rubber.
GM thrust bearing.
GM thrust plate.
Taking out & removing old burnt out windings of the submersible electric motors 75 HP, Three phase, 415 Volts, 50 Hz, AC supply capacity and rewinding of submersible electric motors with existing size PVC insulated, copper conductor wire (Make : Finolex / Atlas) as approved by the Engineer-in-Charge including cleaning the slots with carbon- tetra-chloride solution before rewinding ,transportation to site complete all as specified and directed by Engineer-in-Charge.
Lowering down of the submersible pump set of any description and any capacity & in any position, in bore well alongwith column pipe 100mm dia and submersible cable of any size (approximately 450 feet depth of pump set from GL) complete all as specified and directed by Engineer-in-Charge including making necessary electric connections & testing the pump set after lowering.
Supply and fixing straight through joint complete with jointing materials suitable for three core stranded copper conductor cable PVC insulated and sheathed flat submersible cable 1100 Volt grade of size 25 to 35 Sqmm, all as specified and directed by Engineer-in-Charge.(Make 3M / Denson/Raychem )
M & L for scrubbing out rusted MS column pipe of 100 mm bore with wire brush to remove rust, dirt etc. preparing the surface and applying a coat of anti corrosive bituminous paint complete all as specified and directed. (length of pipes shall be 3.00 meter ).
Material and labour for replacement of rubber gasket of size 100mm joints in flanged end cast iron / MS column pipes and fittings complete with and including minimum 4 mm thick rubber/fibre gasket and necessary nuts/bolts/washers all as specified and directed.
S&F GM Ball Valve 20 mm dia screwed both ends for iron pipes ISI Marked Make :Prayag/ SANT/LEADER
S&F GM Ball Valve 15 mm dia screwed both ends for iron pipes ISI Marked Make :Prayag/ SANT/LEADER
HIND CONSTRUCTIONS
M/s SCHOLASTIC ENTERPRISES
Friends fire Engineers
Ansh Enterprises
VIJAY ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .