Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76,217Accepted-AOC | L1 | Accepted-AOC Lowest valid tender | |
| 2 | L2₹76,292.94+₹76.21 (0.10%)Rejected-AOC THAYYILTHAZHAM KONOTT P O KOZHIKODE 673 571 | KOZHIKODE | KOZHIKODE | KERALA | 673571 | L2 | Rejected-AOC Second lowest valid tender |
Tender Value
Refer Docs
EMD Value
₹2,117
Closing Date
24 Jun 2026, 6:00 pmClosed
Assistant Executive Engineer
O/o the Assistant Executive Engineer, PWD Electrical Sub Division, Kozhikode
GENERAL-District Treasury Kozhikode- Replacement of damaged electrical fittings - General Electrical Work
2026_PWD_855905_1
PWD/BLDG/TR/4094/2026
Open Tender
Electrical Works
Percentage
60 days
Kozhikode
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
₹2,117
23 Jul 2026
15 Jun 2026
27 Jun 2026
15 Jun 2026
24 Jun 2026
15 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1District Treasury Kozhikode-Replacing of damaged electrical fittings | |||||
| 1.001 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture | - | each | 1,232.46 | - |
| 1.002 | OD340866/2025-2026:Supply, Conveyance, installation, testing and commissioning of led recess mounting type LED 600*600 mm(2x2) Luminaire having light output not less than 3600 Lumens with System efficacy> 120 Lumen/Watt . Luminaire Housing Shall be made from single piece CRCA body without welding to avoid rusting and Prismatic diffuser to reduce glare. The Luminaire should be having minimum 50000 Burning hours with CRI ?80, SDCM0.95, Total harmonic distortion THD>10%,EMI/EMC Compliant and Operating voltage range 140-270V with High voltage cutoff@325 ± 15V with Auto restart feature. Luminaire and driver shall be separately BIS approved of same make . LM80,LM79 ,Type Test certificate and Bis certificate need to be submitted for approvals
make PHILIPS, TYPE: RC380B LED30S-6500 G5 L60W60 PSU OD, HSN Code 9405 /equivalent | - | each | 4,747.82 | - |
| 1.003 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator | - | each | 567.37 | - |
| 1.004 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator | - | each | 128.89 | - |
| 1.005 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket | - | each | 318.01 | - |
| 1.006 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) | - | each | 363.09 | - |
| 1.007 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm | - | metre | 110.68 | - |
| 1.008 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | - | metre | 100.61 | - |
| 1.009 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | - | metre | 135.72 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1446627.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tendernotice_2.pdf
PDF • 0.37 MB
Tendernotice_3.pdf
PDF • 0.19 MB
Tendernotice_4.pdf
PDF • 0.47 MB
sbd.pdf
Tender Documents • 1.81 MB
BOQ_1446627.xls
BOQ • 0.31 MB
materiallist.pdf
Tender Documents • 0.18 MB
nit.pdf
Tender Documents • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .