| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.7 L+₹44,334 (1.16%)Rejected-AOC 42 B INDRA NAGAR SRINAGAR J K 190004 | SRINAGAR | SRINAGAR | J K | 190004 | L2 | Rejected-AOC Other than Lowest | |
| 3 | L3₹39.4 L+₹1.2 L (3.07%)Rejected-AOC R O ABI GUZAR THE BUND SRINAGAR 190001 J K | SRINAGAR | JAMMU AND KASHMIR | 190001 | L3 | Rejected-AOC Other than Lowest | |
| 4 | L4₹39.8 L+₹1.6 L (4.15%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest | |
| 5 | L5₹41.0 L+₹2.8 L (7.27%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest |
Tender Value
₹47.9 L
EMD Value
₹95,800
Closing Date
27 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS
GE 969 EWS C/O 56 APO
SPL REPAIR TO BLDG NO T-42 T-43 (OFFICER LIVING ACCN) AT PATTAN AND SPL REPAIR TO FITTING FIXTURE AND ALLIED ELECT INFRA TO CERTAIN BLDGS AT BARAMULLA AND PATTAN UNDER GE 969 EWS
2023_MES_616372_1
CA NO 969 WS - /2023-24
Open Tender
Civil Works
Item Rate
180 days
BARAMULLA PATTAN
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹95,800
Yes
30 Oct 2023
30 Aug 2023
29 Sept 2023
30 Aug 2023
27 Sept 2023
20 Sept 2023
Amount
Taking down carefully copper aluminum point wiring (light. Fan, socket or power complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc.
M&L for Point wiring with 1.5 Sqmm multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVC concealed conduit 20 mm dia medium grade ISI marked with all accessories such as bends, elbows reducers pressed steel/MS terminal boxes factory made 1.6 mm thick duly painted rectangular shape appropriate size (having wall thickness of conduit not less than 2.00 mm) for one light/ fan point controlled by one 5 Amps switch one way, Covered with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets regulators etc and continous PVC insulated and unsheathed 1.5 Sqmm copper conductor cable multistrand as earth wire, complete all as specified and as directed.
(a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way
(b) 3 pin 5 Amp switch socket outlet on same board
(c) 3 pin 5 Amp switch socket outlet on independent board.
All as per item No.2 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multy stranded, FRLS grade and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS grade as earth lead.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.
(a) One light point/fan point/Exhaust fan point controlled by one 5 Amps switch one way
(b)One 3 pin 5 Amp switch socket outlet on independent board.
(c) One 3 pin 5 Amp switch socket outlet on same board with accessories.
All as per Item Srl No 4 above but for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps. screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity Conductor.
S&F switch piano Flush type, single pole, one way 5 amp 240 volts, complete all as specified and directed.
S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, complete all as specified and as directed.
S&F Ceiling rose, 3 terminal /PVC/ polycarbonate, isolated body complete all as specified and as directed.
S&F in repairs MCB,DP 40 Amps 240 Volts B curve, complete all as specified and as directed.
Supply and fixing in repair LED lights fittings 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED bulb 12 Watt, 220V suitable size from ceiling rose complete all as specified and as directed.
S&F Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repairs LED lamp 10 W, complete all as specified and as directed.
Supply and fixing Buzzer, Ding Dong AC, 230 volts, single pole fitting complete all as specified and as directed.
M & L sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of casing capping shall be measured as one RM
M & L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing capping shall be measured as one RM
M & L sub main wiring with two run single core 10 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing capping shall be measured as one RM
Taking down and dismantling the ceiling fan from site and removing its allied smaller parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, split pins, screws, nuts and spring washers complete including flexible chord of 24/ 0.20mm with necessary connector (for blade/body) as required after rewinding complete all as specified and as directed. Note: Spares used and rewiding shall be measured and paid separately under relevant item.
S&F in repair 15 W LED panel round/square type, Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver including connecting cable of suitable size complete all as specified and as directed. Havelis Cat part No LHEBADP61Z1WO15 or equivalent in Bajaj or CG
S&F in repair 36/40 Watt Warm White LED ultra modern recess mounted luminaire (2'x2), environmental friendly, new generation,aesthetically designed, with high brightness complete all as specified and as directed.
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 150mm complete all as specified and as directed.
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200 mm complete all as specified and as directed.
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed.
S&F in repair exhaust fan, steel body AC single Phase 230V of size 450m sweep with blades, and frame and louvers, complete all as specified and as directed.
S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 230 volts, 6 Amps, complete all as specified and as directed.
Repair and re-fixing, re-assembling the existing ceiling fan in same original position along with cable after rectification of defects such as apply the one coat varinsh for windings, painting fan blades, changing fan bearning, rewinding of fan, write MES no on fan blades including nut, bolts and washers complete all as specified and as directed.
Supply and fix in repair sheet metal enclosures for DBs when MCBs to used single pole & neutral (SPN) double door 240 volts, 8 way incl. 200 Amp bus bar and neutral link (1SI marked) complete all as specified and as directed.
Supply and fixing in repair amp rating 240V, 10 KA 'C' Curve miniature circuit breaker MCB SP 5 to 32 Amp and current carrying Capacity in the MCB DB complete with connection testing and commissioning.
S&F in repair MCBs SPN 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards, complete all as specified and as directed.
S&F in repair electric water heater, storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre, BEE 5 star rated cornplete with all accessories such as safety valve, thermostate, NRV, connection piece etc
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor all as specified and as directed.
S&F wall mounting fans complete with all accessories required for fitting , 230 V, 400mm sweep/size (Colour : White/Light Grey/Opal White all as specified and directed
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of charcoal, salt & necessary earth work as Excavation, RF and removal etc."
Supply, Laying ,connecting/ Jointing,charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade with stranded aluminum conductor conforming to IS :7098, laid in trenches/ ducts/ fixed to wall /roofs/ poles all as specified of size 2 Core 16 sqmm including Taking out old unservicable cable from any space, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 mtr deep in depth for laying of cable and foundation of poles, stays and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, excavated soil including spreading, levelling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and as directed.
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
M&L for sand cushioning in trenches for cable protection including consolidation, complete all as specified and as directed.
M&L for Sub class "B" bricks laid dry width wise across the line of cable in trenches as cable protection complete all as specified and as directed.
S&F in repair GI Tubing light grade 40mm dia with all fittings laid in trenches all as specified and directed.
Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement lime or cement mortar complete all as specified and as directed.
M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) complete all as specified and as directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) complete all as specified and as directed.
M&L for preparation of new surfaces of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified and as directed.
M&L for preparation of new surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling of wall and celling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness inlcuding cover fillets complete all as specified and as directed.
M&L 4 mm thick veneered decorative plywoode,grade 1 (with BWR resin) with decorative face veneers on both faces,in wall fixed with screws to timber frame work complete all as specified and as directed.
M&L plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails not exc 3 sqcm in section complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceed 1.5 Sqm complete all as specified and as directed.
Taking down chowkats or frames but with shutters (without taking off the frame) shutters from exceed 1.5 Sgm and not exceed 4.00 sqm complete all as specified and as directed.
S&F 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
Glazed and skeleton shutters thickness 30 mm,(2nd class softwood), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Sectionspecified 8 clause 8.24(a) complete all as specified and as directed.
Glazed and skeleton shutters thickness 35 mm,(2nd class softwood), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Sectionspecified 8 clause 8.24(a) complete all as specified and as directed.
M&L for 2nd class 35mm thick Plain frame panelled shutter with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S&F Sheet glass thickness 3.00 mm,ordinary quality and glazing with oil putty in square exceed 0.5 sqm in each pane complete all as specified and as directed.
M&L Preparation of new wooden surface of any description and two coat of synthetic enamel paint, not otherwise described,over 10cm width or girth complete all as specified and as directed.
M&L Preparation of old wooden surface of any description and two coat of synthetic enamel paint, not otherwise described,over 10cm width or girth complete all as specified and as directed.
Aluminium anodised, barrel tower bolts 100 mm of extruded section and fixed complete all as specified and as directed.
Aluminium anodised, barrel tower bolts 200 mm of extruded section and fixed complete all as specified and as directed.
Aluminium alloy, anodised, sliding door bolt 200 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
M S Butt hinges 100 mm medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.
M S Butt hinges 75 mm medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.
Aluminium handles 100 mm , cast type,anodised complete all as specified and as directed.
Aluminium handles 150 mm , cast type,anodised complete all as specified and as directed.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples sheet glass thickness 3.00 mm,ordinary quality and glazing with oil putty in square exceed 0.5 sqm in each pane complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
S&F Softwood 2nd class Clean sawn with butt joints eaves boards 20 mm thick complete all as specified and as directed.
M&L Weather boarding, 25 mm thick, wrought both sides, V-jointed to give 20mm laps and fixed complete all as specified and as directed.
Dismantling timber scantlings 40 sqcm and over in section in any position unframed work complete all as specified and as directed.
S&F 2nd class softwood in scantling clean swan timber framed and fixed to the position to replace old and decayed timber complete all as specified and as directed.
Dismantling timber in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section in any position unframed work complete all as specified and as directed.
M&L plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails exc 13 but not exc 25 sqcm in section complete all as specified and as directed.
Demolition cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L 25mm thickness Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring complete all as specified and as directed.
M & L Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Incl screed bed 15 mm thick in CM (1:4) complete all as specified and directed.
Note:- Schedule of credit Rs.2,51,940.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/S ZENITH TRADE LINK
M/S GASSI CONSTRUCTION AND CO
LONE CONSTRUCTION COMPANY
M/S ESS EMM ENTERPRISES
M/S KULBIR SINGH SODHI AND CO
M/S HAJI MOHD ASHRAF SUMJI
M/S GHULAM NABI KHUROO AND CO
QAZI SONS
M/s Shabir Ahmed Mir and Bros
M/S IQ ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .