GM - Contract
Construction of 10.26 km Elevated Viaduct from Thaltej Gam Dead End to Godhavi Dead End, including 8 Nos. Elevated Stations, E&M Works for Ahmedabad Metro Rail Project
350869
GMRC/CONS/STNS+VDCT - 1/2026
Open
Civil Works
Works
Gandhinagar
9 documents required · 8 mandatory · 1 optional
₹50,000
₹8.6 Cr
1 Oct 2026
1 Oct 2026
1 Oct 2026
16 Nov 2026
1 Oct 2026
Bill of Quantity (BOQ)
Gujarat Metro Rail Corporation (GMRC) Limited
(SPV of Govt. of Gujarat and Govt. of India)
Formerly known as Metro Link Express for Gandhinagar and Ahmedabad (MEGA) Co. Ltd.
Block No.1, First Floor, Karmayogi Bhavan, Behind Nirman Bhavan,
Sector 10/A, Gandhinagar:
Corporate Identification No (CIN): U60200GJ2010SGC059407
GMRC/CONS/STNS+VDCT-1/2026 BOQ
PREAMBLE AND GENERAL REQUIREMENTS FOR ELEVATED SECTION
The Pricing Document shall be read in conjunction with technical Specification, Employers Requirement,
BOQ’s for the works and other provisions of the tender documents, Schematic tender drawings etc.
including Annexure, Appendix, Addendum / corrigendum and any other document forming part of the
Tender Document.
The Bill of Quantities shall be read in conjunction with the Instructions to the Tenderer, General Conditions of
1. Contract, Special Condition of Contract, Employers Requirement, Scope of work, technical specifications and
drawings etc. If the specifications in the scope of work, Employers Requirement, Technical specification are
inferior with respect to relevant codes and standards then the provision of the Codes and Standards shall
prevail and vice versa. The decision of the Engineer-in- charge regarding this issue shall be binding on the
The quantities given in the Bill of Quantities are estimated and provisional and are given to provide a common
2. basis for bidding. The basis of payment will be the actual quantities of work carried out, as measured by the
Contractor and verified by the Engineer and valued at the rates and prices tendered and accepted in the priced
Bill of Quantities, where applicable, and otherwise at such rates and prices as the Engineer may fix within the
terms of the Contract. The final executed work quantities may vary.
The rates for each item and the Schedule of Items shall be written in indelible ink or type written in the
3. summary sheet in words and figures. Therefore, the quoted price for each Schedule shall be calculated and
written against each Schedule of the work. The total price, as sum of quoted price for all the Schedules of the
work shall be shown at the bottom of the summary sheet. The total price shall also be written in words and
figures. In case of any discrepancy, the amount written in words will be taken. The percentage/item rates shall
be quoted and amount evaluated in Indian Rupees only. as applicable against Schedule/items in BOQ, both in
figures and in words. The person authorized to sign on behalf of the tenderer shall sign in full at bottom of all
pages and at the end of schedule.
All the item of works which are not covered in BOQ Schedule A, B and C1 of structure Section, but are required
4. to be carried out as per the direction of Engineer-in-Charge, shall be carried out under the Schedule-C2 i.e.
Provisional Sum Schedule as per below preference.
i) R&B SOR 2023-24
ii) GWSSB SOR 2022-23
(The rate to be paid shall be as per rates mentioned in above SOR excluding GST)
The rates in BOQ are exclusive of GST (18%) and all other Taxes and cess, ocrtoi etc. as on date of submission.
If the Tenderer fails to fill up the percentage rate, “In each Schedule of the Summary sheets” the offer will be
6. evaluated based on the Par rate (cash value rate of the tender) given in the BOQs and no claim on account of
this will be entertained from the tenderer. However, GMRCL reserve the right to disqualify the tenderer.
General directions and descriptions of work and materials are not necessarily repeated or detailed in the Bill
7. of Quantities. References to the relevant specifications and sections of the contract documentation should be
made before quoting rates in the Bill of Quantities.
The rates are deemed to be inclusive of all lead (except as otherwise specifically provided in the description of
8. the particular item), lifts, ascend, descend, handling, rehandling, crossing of Nallah/Streams/Tracks any other
All enabling works for executing the work e.g. approach road to site, launching arrangements, arrangement of
9. water and electricity and any other incidental works which can be reasonably be inferred to be required for
completing the works is to be arranged by the contractor at his own cost and deemed to be included in the
In all concreting items, all material, equipment, labour, casting beds, stress frames, form work staging,
10. scaffolding, etc is to be arranged by the contractor within the quoted rates.
Storage of Material: All the material at site will have to be properly stacked & stored so as to facilitate
11. inspection. The material should be properly protected from the detrimental effects of nature and fire, theft etc.
The contractor shall be responsible for watch & ward and any loss or deterioration on account of above shall
lead to rejection of material and the contractor has to replace the same at his own cost.
The method of measurement of completed work for payment shall be in accordance with provisions in
12. Contract/Specifications except as otherwise specifically provided in the description of item or particular bill
of quantities or explanatory notes to the particular bill of quantities.
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Obtaining prior permission for felling/cutting of trees will be in the scope of Contractor.
All materials to be supplied by the contractor within the quoted rate for the respective item.
All design mix concrete shall be machine batched with automatic weigh batcher, machine mixed and machine
15. vibrated or Ready Mix Concrete prepared in batching plant and transported by transit mixer to the site of work
or as directed by the structural designer.
The installation price of switchboards, metering panels, DB's or any other items shall include supply and fixing
16. of supporting steel structures/MS channels grouting of the same, associated civil works etc., as required. No
change in unit rate shall be allowed for any change in quantity or for any other reason whatsoever.
Prior to demolishing of any structure measurements will have to be taken. Scheme of dismantling has to be got
17. approved from the Engineer-in-charge.
All activities not specifically covered in BOQ /Schedule of Items, but required to be executed in order to
18. complete the Scope of work have to be deemed as covered with in these mentioned items of the Schedule /
Errors will be corrected by the Employer for any arithmetical errors in computation or summation as indicated
19. in the Contract Document.
The contractor must see the site conditions such as type of soil, locations etc., and take all factors into
20. consideration while quoting in the BOQ as no extra cost will be allowed on any ground arising out of or relating
to the site conditions. earth resistivity testing, water testing all shall be carried and cost of same shall be
considered included in the bid.
The contractor shall take into account the expenses of pre-commissioning tests to be conducted as per
21. specification of the complete installation by licensed agencies.
All temporary works shall be carried out by the contractor including temporary lighting & power at station
22. areas, Switchboards, DG sets, cables, stores, etc.
Repairs to damage of existing carriage way, canal work etc. during construction work shall be carried out by
23. contractor at his own cost as per the technical specifications. Prior to start of repairing work, scheme of repair
work shall be got approved from Engineer in charge.
For all type of cement concrete work rate shall inclusive of
24. I. The rate shall include cost of all necessary admixtures required as per mix design, curing, casting including
centering, shuttering, propping, staging, scaffolding, necessary tools, plants, machinery and all related
operations, etc.
II. The rate shall include cost of carrying out concrete mix design from approved laboratory as described in
the specification or as approved by Engineer-in-charge.
III. The rate is inclusive of all materials, including, mixing in fully automatic batch mix plant, transportation by
transit mixer for any lead from plant site, pumping, pouring, curing, placing in position, making good the
damages, with all lift with contractor's labour, tools & plants, machineries, as required.
IV. The rate is inclusive of providing formwork for exposed form finished concrete surface for concrete above
ground level in desired pattern, sizes with grooves, using laminated shuttering plywood/steel shuttering,
including neat cleaning & rendering of exposed concrete surface, as per the sample approved by the Architect
and as directed by the Engineer-in-charge. (Same kind of shuttering material should be only used for standard
and residual sizes)
V. The rate is inclusive of roughening and/or hacking exposed concrete surfaces for key for plastering, grinding
with carborundum stone over concrete spills / level difference in joints of concrete.
VI. The rate is inclusive of cost of providing grooves, chamfers, moulding, cutout etc. in formwork & using
required dosage of plasticizer in concrete for obtaining required workability as per approval of Engineer-in-
charge. The work will include vibration of concrete, curing protecting from damage, bailing/pumping out
water if required, levelling of ground, making site good etc.
VII. The rate is included labour for keeping embedment if any wherever required while casting.
VIII. The rate shall include form liner finish as per drawing / technical specifications.
The Tenderer’s offer shall be exclusive of GST. Income Tax and any other statutory taxes to be deducted at
25. source, if any, will be deducted by the Employer in accordance with the Income Tax Act and any other acts in
force and in accordance with instructions issued by the Authorities on this behalf, from time to time.
The Tenderer is required to furnish the PAN for all members of Group.
The rates and prices to be tendered in the Bill of Quantities are for completed and finished items of work and
27. complete in all respects. It will be deemed to have included all constructional plant, tools, machinery, labour,
supervision, materials, fuel, oil, consumables, elect& power, water, transportation, all leads and lifts,
GMRC/CONS/STNS+VDCT-1/2026 BOQ
dewatering, all temporary works and false works, construction of temporary stores and buildings, fencing,
watering, lighting, erection maintenance, night working, inspection facilities, safety measures at work sites
casting yard for workmen and road users, preparation of design and drawings pertaining to the casting yard,
staging, shuttering, form work, stacking yard etc., establishment and overhead charges, labour camps,
insurance costs for labour and works, contractor's profit, all taxes, royalties, duties, cess, octroi, and other
levies and other charges together with all general risks, liabilities and obligations set out or implied in the
contract and including remedy of any defects during the Defect Liability Period, unless otherwise provided in
Annexure-13A as duly filled in and priced should be invariably submitted in the Financial Package as
28. mentioned under Para C15.1 of the I.T.T (Instruction to Tenderers) under Volume-1 of Tender-Document and
the evaluation of Financial Package by the Employer will be done in accordance with Para E5 of ITT and other
relevant terms and conditions of the Tender.
Tender Total to be sum of total amount as derived/ quoted in the summary sheet along with addition of Price
Tender Total to be sum of total amount as derived/ quoted in the summary sheet along with addition of Price
29. of unqualified withdrawal of all conditions of Deviation, as per Annexure-13A, if any. This Tender Total will be
used for comparative evaluation of the Tenders.
The tenderer shall include in the Annexure – 2, Tax Estimate of the tender document, the rates/amounts
30. considered in the state and central Tax, duties, levies and included in the tender price and Gujarat state
government taxes, cesses and levies.
The tenderer should quote his percentage against each Schedule in the “summary sheets of each part” only on
31. N Procurement Portal and nowhere else.
The preparation and submission of the design, drawings, etc. for the complete façade works, unitized structural
32. DGU glazing system and all of its elements, roofing with structural steel, space frame, polycarbonate sheet for
the courtyard and atrium, canopies shades at various locations, etc. is in the contractor's scope. The contractor
shall submit 3 qualified façade vendors/structural designers with substantial experience in similar projects.
GMRC will review and select the vendor. The contractor must then obtain designs from the selected vendor
and submit all designs, drawings, and calculations for approval.
All design criteria must comply with relevant codes, force factors, and load factors while maintaining the
original architectural intent. Following design approval, the contractor shall create mockups for final approval
by the Architect/GMRC before proceeding with execution. All these requirements are included in the
contractor's scope, and no additional payment will be made for these items.
The successful contractor shall submit the material sampled which are in co-ordination with interior work like,
33. detector, camera, switchboard, Distribution board, lighting, speakers etc.., to the Engineer for approval prior
to supply/commencement of such works. The approval of these samples to be sought from architect/GMRCL.
Any choice of color model asthetical options from approved makes shall be supplied by contactor at no extra
cost / commercials.
All material to be supplied at site shall be pre intimated to the engineer along with supporting FAT, material
34. test, type test reports and qty sheet along with specification compliance, unless the same is approved and
accepted the material shall not be supplied at site.
All expenses related to material FAT at factory or OEM location shall be borne by contractor, also the cost shall
35. include transportation, lodging & boarding of engineer / GMRCL team attending the testing at factory / OEM
location weather local / abroad.
The successful contractor shall submit 100% compliance against each and every BOQ line items & material
36. specification before work commencement at site or any material delivery at site.
The successful contractor shall submit the Schematic diagrams, fabrication drawings with details of all
37. equipments like D.G, Pumps, wirings diagrams etc., to the Engineer for approval prior to
supply/commencement of such works. The approval of these drawings will be general and will not absolve the
contractor of the responsibility of the correctness of these drawings. At least six copies of the approved
drawings shall be submitted to the Engineer for their distribution to various agencies at site at no cost to the
All testing and calibrating charges for the Meters shall be included in the installation price of the Meter Cubicle.
High voltage testing by Voltage Boosters, relay calibration by secondary injection and meter calibration have
39. to be carried out at site by authorized agencies.
GMRC/CONS/STNS+VDCT-1/2026 BOQ
The contractor shall carry out DG set testing and commissioning including supply of fuel & other
40. consumables/accessories at site without any extra cost for supply of fuel & other consumables/accessories as
required or instructed by the Engineer. Supply of fuel for testing shall be provided by the Contractor after
successful testing DG tank shall be filled by contractor. All the charges for fuel is also included. No seperate
payment shall be made for the supply of fuel.
The contractor shall supply all equipment, spares and consumables required for 104 weeks of Defect Liability
All wall and floor openings where cable containments are passing through shall be sealed with 2-hour fire
42. rated sealant after completion of cable pulling or installation.
The rate also includes all charges like packing and forwarding charges, handling, loading, unloading,
43. transportation, transit and other insurance, hoisting to all levels, setting and fixing in position, disposal of
debris including all other labour, Liabilities, obligations and risks arising out of conditions of contract and
Liaisoning for obtaining approval from CEIG, Fire clearances, Electrical Inspectorate & Local authorities.
All enabling works for executing the work e.g. approach road to site, launching arrangements, arrangement of
44. water and electricity and any other incidental works which can be reasonably be inferred to be required for
completing the works is to be arranged by the contractor at his own cost and deemed to be included in the
All items of E&M works which are not covered in BOQ but are required to be carried out as per direction of
45. engineer in charge will be based on list of concerned item as available in DSR (E&M)
Payment for scheduled E&M works shall be made as follows:
1) 65% on supply and delivery
2) 10% on installation
3) 15% on testing and commissioning
4) 5% on integrated testing and commissioning
5) 5% on taking over
Payment for the Comprehensive Annual Maintenance Contract (CAMC) shall be made in equal quarterly
47. installments over the 5-year contract period (totaling 20 installments), payable at the end of each quarter upon
submission of the service report and invoice.
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Name of Work: Construction of 10.26 km Elevated Viaduct from Thaltej Gam Dead End to Godhavi Dead End, including 8 Nos. elevated Stations (Including E&M Works
and Excluding Architectural Finishing Works & Roofing Works) for Ahmedabad Metro Rail Project, Phase-3A
Annexure – 1, SUMMARY SHEET OF BILL OF QUANTITIES & QUOTED RATES
Total Amount (INR)
(including percent above /
Schedule No. & Description Basic Cost (INR) % at Par/above/below
below / at par of
Amount At Par Value)
Section Description of Section In Figure In Words In Figure In Words
1 Schedule-A General
2 Schedule -B1 Foundation Work
3 Schedule -B2 Cast in Situ Concrete Work
4 Schedule -B3 Precast Concrete Work
5 Schedule -B4 Reinforcement and Prestressing Steel
6 Schedule -B5 Structural Steel
7 Schedule -B6 Bearing
8 Schedule -B7 Miscellaneous Work
GMRC October 2026 Page 6 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Name of Work: Construction of 10.26 km Elevated Viaduct from Thaltej Gam Dead End to Godhavi Dead End, including 8 Nos. elevated Stations (Including E&M Works
and Excluding Architectural Finishing Works & Roofing Works) for Ahmedabad Metro Rail Project, Phase-3A
Annexure – 1, SUMMARY SHEET OF BILL OF QUANTITIES & QUOTED RATES
Total Amount (INR)
(including percent above /
Schedule No. & Description Basic Cost (INR) % at Par/above/below
below / at par of
Amount At Par Value)
Section Description of Section In Figure In Words In Figure In Words
9 Schedule -B8 Structural steel for Open Web Girder
10 Schedule –C1 Electrical System Works
11 Schedule -C2 Fire Alarm System & Fire Fighting System Works
12 Schedule -C3 Air Conditioning & Ventilation System Works
13 Schedule -C4 Building Management System Works
Comprehensive Annual Maintenance for 5 Years
14 Schedule -C5 for completed Electrical and Mechanical system
Provisional Sum for Electrical System, Fire Alarm
System & Fire Fighting System, Air Conditioning
15 Schedule -C6
and Ventilation System, Building Management
System and Miscellaneous Works.
16 Schedule-D1 Road works Item under R&B SOR 2023-24
GMRC October 2026 Page 7 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Name of Work: Construction of 10.26 km Elevated Viaduct from Thaltej Gam Dead End to Godhavi Dead End, including 8 Nos. elevated Stations (Including E&M Works
and Excluding Architectural Finishing Works & Roofing Works) for Ahmedabad Metro Rail Project, Phase-3A
Annexure – 1, SUMMARY SHEET OF BILL OF QUANTITIES & QUOTED RATES
Total Amount (INR)
(including percent above /
Schedule No. & Description Basic Cost (INR) % at Par/above/below
below / at par of
Amount At Par Value)
Section Description of Section In Figure In Words In Figure In Words
Any other items not covered in Schedule A, B &
17 Schedule-D2 D1 but are required to be carried out as per
direction of Engineer, the order of preference for
adopting rates is as follows:
i) R&B SOR 2023-24
ii) GWSSB SOR 2022-23
(The rate to be paid shall be as per rates
mentioned in above SOR excluding GST)
Total Amount of Schedule A, B1, B2, B3, B4, B5, B6, B7, B8, C1,
Total Amount of Schedule A, B1, B2, B3, B4, B5, B6, B7, B8, C1,
C2, C3, C4, C5, C6, D1 and D2 (excluding GST)
01. The tenderer shall quote a percentage (Above/Below/At Par) at SN. 1 to 17 of this summary Sheet only and nowhere else. Total of Schedule from S. No: 1 to 17 shall be
Considered for Tender Evaluation.
02.For the purpose of comparative evaluation of tenders, the amount worked out from the quoted percentage (above/below/at par) or/and quoted rate of item as applicable,
in equivalent INR shall be compared amongst various tenders to determine the lowest evaluated tender applying provision of clause 1.1.3.1 (ix) of NIT.
03. The bidder’s quote to be filled in Annexure – 1 (i.e. Summary Sheet of Bill of Quantity), it should be exclusive of all taxes (GST & Custom duties).
04. The tax bifurcation to be filled in Annexure – 2 (i.e. Details of Taxes and Duties.
GMRC October 2026 Page 8 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Construction of 10.26 km Elevated Viaduct from Thaltej Gam Dead End to Godhavi Dead End, including 8 Nos. elevated Stations (Including E&M Works
and Excluding Architectural Finishing Works & Roofing Works) for Ahmedabad Metro Rail Project, Phase-3A
Summary of Bill of quantities
Section Description of Section Amount (Rs)
Schedule-A General
Schedule B:-Civil Structural work
Schedule -B1 Foundation work
Schedule -B2 Cast in Situ concrete work
Schedule -B3 Precast concrete work
Schedule -B4 Reinforcement and prestressing steel
Schedule -B5 Structural steel
Schedule -B6 Bearing
Schedule -B7 Miscellaneous work
Schedule -B8 OWG Steel Structure
GMRC October 2026 Page 9 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Schedule C:- E&M Works
Schedule - C1 Electrical System Works
Schedule - C2 Fire Alarm System & Fire Fighting System Works
Schedule - C3 Air Conditioning & Ventilation System Works
Schedule - C4 Building Management System Works
Schedule - C5 Comprehensive Annual Maintenance for 5 Years for completed Electrical and Mechanical system
Schedule- C6 Provisional Sum for Electrical System,Fire Alarm System & Fire Fighting System, Air Conditioning and
Ventilation System, Building Management System and Miscellaneous Works
Schedule D :-Provisional Sum
Schedule D1 Road works Item under R&B SOR 2023-24
Schedule D2 Any other items not covered in Schedule A, B & D1 but are required to be carried out as per direction
of Engineer, the order of preference for adopting rates is as follows:
i) R&B SOR 2023-24
ii) GWSSB SOR 2022-23
(The rate to be paid shall be rate of SOR excluding GST)
Total Amount (excl. GST)
Total Amount (excl. GST)
GMRC October 2026 Page 10 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Schedule A - General Items
Item Description Unit Rate (excl. GST) Quantity Amount (Rs.)
Note: During the Contract period till the completion of the works
the contractor shall provide the following:
1 Surveying for verifying alignment, marking pier location, vertical KM 83,648.50 10.26
& horizontal clearances and establishing triangulation points and
bench marks for the elevated corridor including corrections, if
Note: The payment schedule for the item shall be as follows:
I. Payment @ 25% of total cost of the item on checking and
approval of all control points and submission of drawings.
ii.Payment @ 70% of total cost of the item equally distributed
over the duration of the contract and will be paid on pro-rata
ii.Payment @ 5% of total cost of the item on satisfactory
completion of work along with the final bill.
(i) Payment @ 25% of total cost of the item on checking and
approval of all control points and submission of drawings.
(ii) Payment @ 70% of total cost of the item equally distributed over
the duration of the contract and will be paid on pro-rata basis.
(iii) Payment @ 5% of total cost of the item on satisfactory
completion of work along with the final bill.
GMRC October 2026 Page 11 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
2 Providing temporary barricade in good condition RM 4,975.10 -
(new/refurbished) including all road safety devices on both sides
of viaduct/stations during construction at site as per technical
specifications and GFC drawings. Temporary barricade shall be of
plain MS sheet 16 Gauge fixed with steel frame as per drawing,
painting (including primer of approved quality) with synthetic
enamel paint of approved color, quality and brand, writing
lettering and logo of Metro including maintenance of the same
duly cleaning the same on fortnightly basis and painting if
required, arrangement for blinker lights/ rope light on barricades
during night as per requirement and as per the instruction of the
Engineer-in-charge. During the construction, barricading has to be
kept continuously. Nothing extra will be paid for dismantling and
re-erecting the barricades within contract boudry. There should
not be any opening at the end of barricade except at locations
approved by Engineer-in-charge. (Barricading for road widening
work shall be measured separately). Barricading may be required
to be shifted laterally number of times as per site
requirements/sequence of works but payment will be made only
on first installation. In case of variation in weight per RM, the
prorata rate adjustment will be made for 70% of cost
GMRC October 2026 Page 12 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
(i) Barricades on either side shall be measured individually.
(ii) Once barricade has been provided and work started, removal
of barricade is not permitted till completion of pile, pile cap, pier
and pier caps, portal beams, superstructure complete , till
completion of entire superstructure.
(iii) While erecting barricade, the bottom gap between barricade
and road should be plugged with cement concrete from inside.
(iv) Adequate blinking lights (rope light) on barricade during night
time must be ensured. The cost of this item should include
provision for power pack / Genset etc. so as to ensure the
blinking of lights in night time as long as barricades are in position
at the work spot.
(v) After completion of the entire work, the barricades shall be - -
the property of the contractor.(vi) Replacement of damaged
barricades shall be done by contractor at his own cost. Nothig
shall be payable extra.It is specifically highlighted that barricading
during construction shall be limited to 8m to 10m width only,
considering the traffic constraint. This width applies to viaduct in
straight portion. In station areas and on curves, the barricading
width and placing shall be as approved by the Engineer in
consulation with the traffic management.For barricading
payment shall be made at 70% on erection of barricade and 30%
on removal of barricade as per the instructions of Engineer in-
(i) For barricading payment shall be made at 70% on erection of RM 3,482.57 22,760.00
(ii) 30% on removal of barricade as per the instructions of Engineer RM 1,492.53 22,760.00
GMRC October 2026 Page 13 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
3 Submit colour photographs (Ground/Aerial) of the works as Per month 1,989.00 34.00
directed by the Engineer-in-charge and supply at monthly
intervals, or as instructed by the Engineer-in-charge. One set shall
comprise one soft copy with three copies of prints (hard copy in
Glossy paper) of each photograph of size not less than 225 x
mm each. (40 to 50 nos per month).
4 Supply of Gorund/Aerial video and DVDs/pendrive of 180 minutes Per month 9,945.00 34.00
duration comprising one master copy and one extra copy as per
technical specifications showing the progress of works as directed
by Engineer-in-charge.
5 Providing furnished office accommodation at site for the use of Per month 4,55,000.00 34.00
site engineer and his supporting staff approximately of 700 sqm
carpet area (fully air conditioned) including site office at casting
yard with minimum two watchman and two office boy in each
office for 24hrs and also as per increased on its requirement.
Offices may be at single or multiple locations as directed by the
Engineer-in-charge.
Note: 1) The details of site office and furniture, computer - -
equipment, software etc., to be provided by the Tenderer, are
shown in the "Employers requirement".
2) This furnished accommodation shall be provided by the
Tenderer during the contract period and also extended period of
3) For the extended period of contract, contractor will be paid
only the actual expenditure incurred for operating this item. No
extra payment will be allowed.
GMRC October 2026 Page 14 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
6 Cutting, transporting of trees including primary root, stacking and - -
handing over to the concerned department as per instruction of
Engineer-in-charge.
(i) Girth upto 30cm Nos. 422.50 50.00
(ii) Girth more than 30cm but upto 50cm Nos. 422.50 50.00
(iii) Girth more than 50cm but upto 75cm Nos. 757.90 50.00
(iv) Girth more than 75cm but upto 1.25m Nos. 1,470.30 50.00
(v) Girth more than 1.25m but upto 2.4m Nos. 2,536.30 50.00
(vi) Girth More than 2.4m Nos. 3,043.30 20.00
7 Transplanting the marked trees of various species and girth to the - -
place shown by Engineer-in- charge/Engineer’s representative
within a lead of 1.5km with all tools, plants, man & machinery
and necessary preparation such as preparation of earth ball of
tree roots of desired depth & diameters, dislodging, lifting,
transportation and transplanting tree from original place to the
new place including all arrangements, tools & plants, labour etc.,
for successfully completing the work. The work includes
excavating pits of adequate size, arranging loose soil, mixing of
manure, fertilizer, insecticides etc., to ensure survival of the trees
being transplanted. Maintenance of tree i.e., watering, manuring,
soil heaping, spray of insecticides shall be done for one year. All
above operations shall be executed as per specification.
(i) Girth upto 30cm Nos. 11,271.00 50.00
(ii) Girth more than 30cm but upto 50cm Nos. 12,994.80 50.00
(iii) Girth more than 50cm but upto 75cm Nos. 14,586.00 50.00
(iv) Girth more than 75cm but upto 1.25m Nos. 16,177.20 10.00
(v) Girth more than 1.25m but upto 2.4m Nos. 19,492.20 10.00
(vi) Girth More than 2.4m Nos. 24,265.80 10.00
GMRC October 2026 Page 15 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Stage wise payment for the work will be as following: - -
30% after trees transplanted.
40% after sprouting & establishment of trees
30% after completion of maintenance period of one year.
7(a) Extra over item no A.7 (above) for lead more than 1.5 km and per km 663.00 50.00
upto 5 km for all girth for transportation (per km)
8 Carryout Geo-technical investigation work (as and where RM 1,989.00 1,080.00
required) including exploratory drilling of 150 mm dia boreholes
in all sorts of soil, ordinary rock and hard rock, up to maximum
depth as mentioned, collecting undisturbed samples and
conducting standard penetration tests alternate at an interval of
1.5 m. depth, conducting necessary laboratory tests & field tests
for all type of classification and determination of soil parameters
like density, shear and consolidation parameters if required,
including submission of report in three copies covering
investigation data and recommendation for SBC and the pile
capacity considering the design criteria, all as per specification.
1)The rate is inclusive of submitting soil investigation report in
three sets in hard copy as well soft copies.
9 Traffic Signals,Signage Etc. - -
9(a) Providing & fixing of retro-reflective traffic sign boards using high sqm 7,186.40 250.00
intensity Retro Reflective Sheeting (encapsulated lens type) as
recommended by IRC and MORTH on 2mm Aluminium Substrate
properly processed on front side of Aluminium substrate with
pressure sensitive Heat vacuum applicator. Logos and Borders
may be out of cut-sheet or screen printing with appropriate ink
which should also have 7 years warranty. The Retro Reflective
traffic sign boards using high intensity Tape should have MS angle
support of size 25 x 25 x 3 mm or 35 x 35 x 4 mm depending upon
GMRC October 2026 Page 16 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
9(b) Providing and fixing and maintaining the road - -
infrastructure/furniture during executions, refixing as where
(i) Road delineator - Supply of Rectangular Metal Delineator (Black Nos 1,259.70 300.00
colour Rectangular Delineator with high intensity Reflective
Height: 1200 mm approx..
Size: 100 x 40 mm rectangular
Reflective: 1 no. Band of 120 mm High Intensity Grade Red
Colour Reflective tape and 3 Nos. Bande of 150 mm white colour
(ii) Portable Signage - Supporting of Retro-Reflective Sign Board of Nos 4,641.00 200.00
size 900 mm Triangular or 60 mm Dia Circle or 90 x 600 mm by
using high intensity Retro Reflective Sheeting on 2 mm thick
Aluminium Substrate with M.S. Back Support frame
(iii) Reflective lights - Hazards warning Blinkers both sides Nos 1,989.00 500.00
(Rechargeable with 2 Nos. sealed maintenance free batteries)
(iv) Traffic Cones Nos 1,127.10 400.00
Square Base cone with heavy base of size 390 mm x 390 mm - -
Cone Colour: Red Colour (UV stabilized)
Body Material: Low Density Poly Ethylene
Reflective Part: 1 No. White colour Engineering Grade Reflective
band of 125 mm width all around.
Note: - The specifications given in this BOQ item are not - -
complete. In addition, the items shall comply with the regulations
and Tender Specifications. After completion of the entire work, all
the items will be the property of the contractor and he is also
responsible for shifting all such release materials away from the
GMRC October 2026 Page 17 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
9(c ) Deployment of adequate manpower for 8hrs shift for day and - -
night management of traffic at intersection, roadway influenced
by contractor and traffic diversions at various levels.
In-charge-(minimum 1) shift 1,127.10 2,700.00
Supervisor-(minimum 2) shift 981.24 5,400.00
Traffic Guards-(maximum 50 man days per day) shift 928.20 54,000.00
Note : The deployment to be done with prior approval of GMRCL
and Traffic Police. The personnel at above should be familiar with
traffic rules and regulations the traffic signals and road
delineators shall be placed as per approved plan and shall be
prepared as per relevant code and Ahmedabad Traffic Police
10 Construction of rainwater harvesting well consisting of 4.5m Each 2,69,312 27
internal dia, 4.5m deep with 1 no. 200 mm nominal dia PVC plain
screen pipe with ribs conforming to IS: 12818-1992, upto sub soil
water table, including boring etc. Earth work excavation upto
required depth, brick masonry 75 class brick in cement mortar 1:4
foundation concrete 1:4:8, 150 mm thick RCC top slab with steel
reinforcement, centering and shuttering 1 no. precast RCC EHD
manhole cover & frame, with 8 mm thick plastic encapsulated
foot rest at the rate of 300mm c/c, 400 mm thick fine sand and
600mm thick stone aggregate (6mm to 40mm nominal size), at
bottom level complete as per detail drawings, nothing extra will
GMRC October 2026 Page 18 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Schedule B1 - FOUNDATION WORK
Item Description Unit Rate (excl. GST) Quantity Amount (Rs.)
1 Providing Excavation for utility mapping and shifting based on site condition. This Cum
shall includes following items 423.42
1. Excavation through existing concrete/ water bound macadam road / bituminous
road / concrete road/soil/morrum/ hard rock /soft rock/ old structures below
ground as encountered of all thickness including dismantling other structures, dead
utilities, dewatering, pumping and bailing out water, strutting and shoring, etc. for
utility identification shall be done by either manually or with necessary precautions
so that existing utility shall not damage. At each pier location sizes of excavation
pits will be given.
2. Temporary suppurt for utility if required.
3. utility mapping and submission of utility mapping in soft and hard copy with
plan,elevation and cross-sections coordinates in autocad and with photographs for
submission to DDC review.
4. If boring will required, same will be paid in separate item (Ref item no B.2)
5. If utility shifting is required it shall be paid under relevant BOQ item.
6. Back fill of excavated soil upto natural ground level with sufficient compaction
for required stability of piling rig during piling work.
2 Boring 100mm dia borehole, 8m deep at pile locations to find out underground RM
utilities as directed by Engineer in charge. 705.58
GMRC October 2026 Page 19 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
3 Providing and installing cast-in-situ vertical bored piles as per approved good for - -
construction (GFC) drawing and with M35 grade of concrete (as per specification)
using OPC cement confirming to sulphate concentration criteria as per Sl. No. (i) &
(ii) of Table 4 of IS 456 and for high concetration sulphate content the type of
cement shall be used as per Sl. No. (iii), (iv) & (iv) of Table 4 of IS 456, including all
operations such as installation and shifting of piling rig etc, in all type of soil
strata/rocky strata along elevated section. Minimum cement content shall be
380kg/cum. The cost includes the cost of empty boring wherever required.
(Measurement shall be from cut-off level to founding level). The stated length
includes test piles for initial load tests. The item includes disposal of earth, muck,
slush released from piles, top cutted portion of pile at disposal ground for all leads.
Reinforcement shall be paid separately. Rate shall include cost of using required
dosage of admixture in concrete for obtaining required workability as per approval
of Engineer in charge. Rate shall includes provision of A class MS pipes of 50mm
outer diameter as per technical specification, minimum 1.0mm thick (light) as
per IS 1239M in all piles at the time of casting to be used for cross-hole sonic
test. Pipes shall extend from ground level to bottom of pile where pipe shall be
sealed at bottom. Rate includes filling of tubes after sonic test using standard
cement non-shrink mortar before casting of pile cap. The item includes drilling and
socketing in rock at required depth. Idling of rig due to any reason shall not be
payable. Bore drilling shall be done by use of hydraulic rig using temporary casing
of required depth and polymer slurry. The item includes the cost of polymer to be
used for stabilisation of bore.
Note: 800mm dia/ 1000 mm dia /1200 mm dia /1500 mm dia/1800 mm dia - -
multiple pile foundation will be implemented. The lengths of each pile diameter is
indicative only and may vary at Detailed Design stage.
3.1 For 800mm dia Pile RM
3.2 For 1000mm dia Pile RM
3.3 For 1200mm dia Pile RM
GMRC October 2026 Page 20 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
3.4 Extra over item no B3 (above) for providing M40 grade concrete for pile instead of cum
M35 grade concrete. (Minimum cement content shall be 390 kg/cum of concrete) 350.83
4 Providing and fixing permanent MS liner (of required thickness or as directed by MT
Engineer-in-charge) for 800/1000/1200/1500/1800 mm dia bored cast-in-situ piles 1,04,401.90
wherever required as per approved construction drawings and directions of
Engineer-in-charge all complete and applying a primer coat of approved steel
Measurement :- The liner shall be of MS plate, of required thickness or as per - -
drawings duly approved. The payment of liner shall be made in Kg as per the area
of the MS sheet provided in liner multiplied by density (78.5 kN/m3). The quoted
rates will be applicable for all lengths provided upto the soffit of pile cap. The
measurement will be made for the actual length of liner provided correct to one
5 Carrying out static initial vertical load tests as per relevant IS Codes including - -
all arrangements for measuring deflections and submitting reports as per
specifications. This includes making of pile head ready for testing at the desired
level, supporting / reaction arrangement (including reaction piles/soil/rock
anchors, if any) for the kentledge load. Cost of pile to be tested wil be paid in
item B.3. The test arrangements shall cater for additional 25% above test load)
(i) 800 mm dia pile (Test load of 680MT) Nos.
(ii) 1000 mm dia pile (Test load of 1200MT) Nos.
(iii) 1200 mm dia pile (Test load of 1800MT) Nos.
6 Carrying out static initial lateral load tests as per relevant IS Codes including - -
all arrangements for measuring deflections and submitting reports as per
specification and tender drawing. This includes making of pile head ready for
testing at the desired level, supporting / reaction arrangement (include
reaction piles/ soil/ rock anchors, if any) for the kentledge load. (Cost of test pile
will be paid in item B.3 )
GMRC October 2026 Page 21 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
(i) 800 mm dia pile (Test load of 38MT) Nos.
(ii) 1000 mm dia pile (Test load of 50MT) Nos.
(iii) 1200 mm dia pile (Test load of 63MT) Nos.
7 Carrying out static routine vertical load tests as per relevant IS Codes - -
including all arrangements for measuring deflections and submitting reports. This
includes making of pile head ready for testing at the desired level, supporting /
reaction arrangement (incl. reaction piles/soil/rock anchors, if any) for the
kentledge load. The test arrangements shall cater for additional 25% above test
(i) 800 mm dia pile (Test load of 375MT) Nos.
(ii) 1000 mm dia pile (Test load of 675MT) Nos.
(iii) 1200 mm dia pile (Test load of 975MT) Nos.
8 Carrying out static routine lateral load tests as per relevant IS Codes - -
including all arrangements for measuring deflections and submitting reports. This
includes making of pile head ready for testing at the desired level, supporting /
reaction arrangement (incl. reaction piles/ soil/ rock anchors, if any) for the
kentledge load.
(i) 800 mm dia pile (Test load of 23MT) Nos.
(ii) 1000 mm dia pile (Test load of 30MT) Nos.
(iii) 1200 mm dia pile (Test load of 38MT) Nos.
9 Non destructive integrity testing of piles of 800mm/ 1000 mm/1200 mm /1500mm Nos.
/1800mm dia and as per specifications and submitting reports. (Payment shall be 1,169.44
made for number of pile tested)
GMRC October 2026 Page 22 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
10 Integrity pile test using cross-hole sonic logging for 0.8m, 1.0m, 1.2m, 1.5m, 1.8m Nos.
diameter piles as per the provision of ASTM standard D6760, as per drawings & 8,770.78
technical specifications. (Payment shall be made for number of pile tested)
11 Providing M-15 grade concrete (as per specification) for minimum 75mm cum
thick PCC below pile cap, open foundation slabs and ramp foundations 4,735.93
extending 75mm all around beyond pile cap, open foundation slabs and ramp
foundations. Rate shall include cost of using required dosage of admixture in
concrete for obtaining required workability as per approval of Engineer.
11a Providing M-15 grade concrete (as per specification) for minimum 75mm cum
thick PCC below open foundation/ raft/ combined foooting for other than station 4,735.93
box area (i.e. entry- exit structures. water tanks, escalator, lift pits, staircases
pump house etc) extending 75mm all around footing. Rate shall include cost
of using required dosage of admixture in concrete for obtaining required
workability as per approval of Engineer.
GMRC October 2026 Page 23 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
12 Providing M-35 grade, reinforced cement concrete (as per specification) using OPC cum
cement confirming to sulphate concentration criteria as per Sl.No. (i) & (ii) of Table 6,948.92
4 of IS 456 and for high concetration sulphate content the type of cement shall be
used as per Sl. No. (iii), (iv) & (iv) of Table 4 of IS 456, for pile cap including
excavation through existing concrete/ water bound macadam road / bituminous
road / concrete road /soil/morrum/ hard rock /soft rock/ old structures below
ground as encountered of all thickness including dismantling other structures, dead
utilities, dewatering, pumping and bailing out water, strutting and shoring, curing
etc.Minimum cement content shall be 380kg/cum. The item also includes
formwork and backfilling in foundation with quarry dust/sand including watering,
compacting with a vibratory plate compactor. The Cost includes cutting/chipping of
pile up to cut off level or up to good concrete and built up of pile up to required
level. The cost includes loading, unloading and disposal of surplus excavated
material along with pile heads using covered trucks to contractor's dumping yard, /
disposal of surplus excavated material at with all leads and lifts and as directed by
the Engineer-in-charge or anyother dumping ground as directed by Engineer within
40 Km of the alignment. The contractor should ensure that during transportation
the carried material does not spill out. Reinforcement shall be paid separately. Rate
shall include cost of using required dosage of admixture in concrete for obtaining
required workability as per approval of Engineer-in-charge. (6% of the amount shall
be withheld. Out of this,3 % of the amount shall be released after disposal of
excavated material including pile head material at contractor's dumping yard and
% of the amount shall be released after restoration works on pile caps). Rate
includes restoration of road work over the excavation zone for pile cap i.e. GSB and
WMM over sand filling as per the instruction of the Engineer.
(i) 94% on pile Cap casting -
(ii) 3% on disposal exavted material -
(iii) 3% on restoration work -
12 (a) Extra over item no 12 (above) for providing M45 grade concrete for pile cap cum
instead of M35 grade concrete. (Minimum cement content shall be 410 kg/cum of 350.83
GMRC October 2026 Page 24 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
12.(b) Providing M 35 grade, reinforced cement concrete (as per specification) using cum
OPC cement confirming to sulphate concentration criteria as per Sl.No. (i) & (ii) of 6,948.92
Table 4 of IS 456 and for high concetration sulphate content the type of cement
shall be used as per Sl. No. (iii), (iv) & (iv) of Table 4 of IS 456, for pile cap
/ open foundation/ raft/ combined foooting for other than station box area
(i.e. entry- exit structures. water tanks, escalator, lift pits, staircases pump
house, FOB's etc) including excavation through existing concrete/ water bound
macadam road / bituminous road / concrete road /soil/morrum/ hard rock
/soft rock/ old structures below ground as encountered of all thickness
including dismantling other structures, dead utilities, dewatering, pumping and
bailing out water, strutting and shoring, curing etc. Minimum cement content shall
be 380kg/cum. The item also includes formwork and backfilling in foundation with
earth/quarry dust/sand including watering, compacting with a vibratory plate
compactor. The cost includes loading, unloading and disposal of surplus excavated
material using covered trucks to contractor's dumping yard with all leads and lifts
and as directed by the Engineer-in-charge. The contractor should ensure that
during transportation the carried material does not spill out. Reinforcement shall
be paid separately. Rate shall include cost of using required dosage of admixture in
concrete for obtaining required workability as per approval of Engineer-in-charge.
(6% of the amount shall be withheld. Out of this,3 % of the amount shall be
released after disposal of excavated material including pile head material at
contractor's dumping yard and 3 % of the amount shall be released after
completing road restoration works. Rate includes restoration of road work over the
excavation zone. (Minimum cement content shall be 380 kg/cum of concrete)
12 (c) Extra over item no 12 b (above) for providing M45 grade concrete for pile cap cum
instead of M35 grade concrete. (Minimum cement content shall be 410 kg/cum of 350.83
13 For all RCC items of schedule B1, minimum cement content has been specified. For Kg 6.21
any extra /less cement above or below the minimum specified cement content,
addition/deduction shall be paid under this items.
GMRC October 2026 Page 25 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Schedule B2 - IN-SITU CONCRETE WORK
Item Description Unit Rate (excl. Quantity Amount (Rs.)
1 Providing and laying M-40 grade cement concret (as per technical cum 8,128.00 1801.08
specification) for reinforced cement concrete crash barrier/pier protection all
round the pier leaving a gap of 25mm min between and following the pier shape
exactly on at grade road as specified in drawings, including centering,
shuttering, compaction, scaffolding, curing and all related operations as
required to complete the work. The gap shall be filled with either coarse sand or
compressible filler board of high density as directed by Engineer in charge or as
per GFC drawings. Rate includes the cost of required dosage of admixture
in concrete for obtaining required workability and cost of compressible fibre
board or coarse sand as per specification and approval of Engineer in
charge.Reinforcement will be paid separately.
Minimum cement content shall be 390 kg/cum of concrete.
GMRC October 2026 Page 26 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
2 Providing and laying M-55 grade reinforced cement concrete (as per cum 9,227.00 21814.80
specification) for Viaduct & Station piers (standard pier, portal pier, &
cantilever pier, Column from concourse slab to platform level, Pedestals) etc
and column for stations including shuttering scaffolding and all related
operations required to complete the work at all levels including centering,
shuttering, propping, staging, scaffolding, compaction, curing, necessary tools,
plants, machinery and all related operations etc.for all heights using steel
material for shuttering & steel props. Form work to be designed in a such way
that traffic on road is allowed during the work at all times. Rate includes cost of
providing grooves if required (the ribs/grooves in pier shutter if required,
shall be as per drawing). Reinforcement shall be paid separately. Rate
includes cost of using required dosage of admixture in concrete for
obtaining required workability, curing compound as per specification &
approval of Engineer in charge. Minimum cement content shall be 440 kg/cum
Note:(i) No cold joints are permitted. However cold joint at the junction of " pile - -
cap-pier" and at the top surface of the starter of pier (which is normally less
than 2m length), cold joints are unavoidable. In that case old concrete
surface should have adequate shear keys depressions,reinforced dowels
and a layer of concrete bonding compound. Concrete retarder compound
may also have to be used at the concrete surface of starter pier above the pile
cap.The rate is inclusive of all above bonding agents/methods. However if
any additional cold joints are unavoidable due to the reasons not beyond
the control of contractor, all above bonding measures shall be on account of
the contractor.
(ii) Concreting must be carried out using concrete pumps or concrete placer
GMRC October 2026 Page 27 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
2(a) Extra over item no 2 (above) for providing M60 grade reinforced cement cum 819.00 500.00
concrete instead of M55 grade concrete. Minimum cement content shall be
450kg/cum of concrete.
2(b) Deduction for Providing M40/20 concrete instead of M55/20 concrete in above Cum -241.00 500.00 -1,20,500.00
Concrete items. Minimum cement content shall be 390 kg/cum of concrete.
3 Providing and laying M 40 grade reinforced cement concrete (as per cum 8,439.00 5000.00
specification) for station beam and slab (Beam/slab at concourse level, wall
and slab for Lift, beam and slab for staircase & escalator, Beam/slab/
parapet wall at Platform Level, Parapets, Pedestals at Platform Level, Cable
Trough etc) including shuttering scaffolding and all related operations
required to complete the work at all levels including centering, shuttering,
propping, staging, scaffolding, compaction, curing, necessary tools, plants,
machinery and all related operations etc.for all heights using steel material for
shuttering & steel props. Form work to be designed in a such way that traffic on
road is allowed during the work at all times. Rate includes cost of providing
grooves if required (the ribs/grooves in pier shutter if required, shall be
as per drawing) and sleeves with different diameters. Reinforcement shall
be paid separately. Rate includes cost of using required dosage of
admixture in concrete for obtaining required workability, curing compound
as per specification & as per specifications includes loading, unloading and all
complete as per approved drawings and specifications.
Minimum cement content shall be 390 kg/cum of concrete.
GMRC October 2026 Page 28 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
4 Providing M 55 grade reinforced cement concrete for Reinforced concrete (as cum 10,264.00 5751.50
per specification) for portal beam (integral to pier)/ Pier Cap including
shuttering scaffolding and all related operations required to complete the
work at all levels including centering, shuttering, propping, staging, scaffolding,
curing, necessary tools, plants, machinery and all related operations etc.for all
heights using steel material for shuttering & steel props. Form work to be
designed in a such way that traffic on road is allowed during the work at all
times Rate includes required dosage of admixture in concrete for obtaining
required workability as per approval of Engineer in Charge. Reinforcement
will be paid separately.
4.b Extra over item no 4 (above) for providing M60 grade reinforced cement cum 819.00 100.00
concrete instead of M55 grade concrete.
Minimum cement content shall be 450 kg/cum of concrete.
5 Providing M 55 grade reinforced cement concrete (as per technical cum 10,310.00 1250.80
specification) for Pedestals and Shear Key/Seismic Stopper including centering,
steel shuttering, scaffolding and all related operations as required to complete
the work as specified in drawings. Reinforcement shall be paid separately. Rate
includes required dosage of admixture in concrete for obtaining required
workability as per approval of Engineer in charge.
Minimum cement content shall be 440 kg/cum of concrete.
GMRC October 2026 Page 29 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
6 Providing M50 grade reinforced cement concrete (as per technical specification) cum 10,801.00 4200.00
for deck slab over Precast I Beams/Steel beams & cross-girder/FOB's etc
including centering, steel shuttering, scaffolding and all related
operations as required to complete the work as specified in drawings.
Rate includes provision of formwork of steel/concrete for casting of slab.
Reinforcement shall be paid separately. Rate includes required dosage of
admixture in concrete for obtaining required workability as per approval of
Engineer-in-charge.
Minimum cement content shall be 430 kg/cum of concrete.
7 Providing M45 grade reinforced cement concrete (as per technical specification) cum 7,605.00 5649.60
for other than station box area (i.e. entry- exit structures. water tanks,
escalator, lift pits, staircases pump house etc) including centering, steel
shuttering, scaffolding and all related operations as required to complete the
work as specified in drawings. Rate includes provision of sacrificial formwork of
steel/concrete for casting. Reinforcement shall be paid separately. Rate includes
required dosage of admixture in concrete for obtaining required workability as
per approval of Engineer-in-charge.
Minimum cement content shall be 410 kg/cum of concrete.
8 Providing reinforced cement concrete for stitch concrete (all types and levels),
upstands (all types and levels), Diaphargm and similar elements, complete
with centering, steel shuttering, scaffolding, sacrificial formwork (steel/concrete
as required), and all related operations as per drawings and specifications.
Reinforcement shall be paid separately. Rate includes approved admixture
dosage for required workability as per Engineer-in-charge’s approval.
GMRC October 2026 Page 30 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
a) M40 grade reinforced cement concrete (Minimum cement content shall be 390 Cum 8,128 3989.45
kg/cum of concrete)
b) M50 grade reinforced cement concrete (Minimum cement content shall be 430 Cum 9,196 200.00
kg/cum of concrete)
c) M55 grade reinforced cement concrete (Minimum cement content shall be 440 Cum 10,264 200.00
kg/cum of concrete)
9 For all RCC items of schedule B2, minimum cement content has been specified. Kg 6.21 105240.00
For any extra /less cement above or below the minimum specified cement
content, addition/deduction shall be paid under this items.
10 Providing, fabricating, supplying, transporting, placing and fixing galvanized sqm 609 3300.00
corrugated steel deck sheets instead of conventional temporary centering,
steel shuttering and scaffolding over Precast Beams/I-girder/Steel girder/cross-
girder/pie-girder etc as per the instruction of Engineer incharge. for casting of
RCC deck slab, including cutting, bending, lapping, fastening to girders with
shear studs/clips/self-drilling screws, providing edge trims, closures and all
accessories complete as per approved drawings and specifications. The rate
shall include all labour, materials, equipment, handling, wastage, staging
required for fixing, and all incidental works necessary for completion of the
item, measured in square metres of deck slab. The rate includes material,
labour. machinery, accessroies, fixtures etc at all levels and locations, all
complete as per instructions of Engineer Incharge.
GMRC October 2026 Page 31 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Schedule B3 - PRECAST CONCRETE WORK
Item Description Item Rate (excl. Quantity Amount (Rs.)
1a Establishment of casting yard; LS
Establishment of casting yard for all precast elements including batching plant -
for concrete production, storages, labs, office and other facilities to execute
the work as per good engineering practices and as approved by engineer to
ensure production and storage of all precast element to achieve the specified
key dates, comprising as mentioned below, which shall be increase/decrease
with approval of Engineer-in-charge, suitably to suit the construction schedue
for achieving the Key Dates (KDs)
A. Casting bed for U -girder - 36 nos. -
B. Casting bed for pier cap - 8 nos
C. Casting bed for I girder - 6 nos. I Girder
D. Batching plant capacity should be minimum 60 cum/hour & 30 cum/hour
The payment of this item shall be made as under
A. Developing access -10%
B. Establishing bed for U grider, I girder, pier cap and gantries - 40%.
C. Establishing of batching plant, labs, office - 30%
D. Completion of full facilities as approved by engineer -20%.
The amount shall be paid against the indemnity bond.
1.b Recovery against payment of establishment of casting yard LS -
Recovery against payment of establishment of casting yard @ 15000000 in 5 -
GMRC October 2026 Page 32 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
2 Providing M55 grade reinforced cement concrete (as per technical cum
specification) Precast Prestressed Pier Cap/Precast portal beam including 12,598.21 20,111.85
shear key, pedestals, in-situ connection with pier. The item includes lifting the
pier caps from the mould and shifting the same to the stacking yard. The item
includes provision of holes for lifting and filling of holes after erection
using non-shrink grout. Reinforcement, strands, cables, anchorages and
sheathing shall be paid separately. Rate includes cost of using required
dosage of admixture in concrete for obtaining required workability as per
approval of Engineer-in-charge and all related operations as required to
complete the work as per drawing & specifications. The cost includes
centering, shuttering, scaffolding, providing cutouts where specified,
curing arrangements as required, steam curing arrangement if deemed
necessary, all handling etc. complete.
Minimum cement content shall be 440 kg/cum of concrete.
3 Transporting precast Standard Pier Caps/Precast portal beam from the MT
casting yard / storage yard to the work site, erection in position including 1,475.35 50,279.63
the cost of all temporary supports, erection equipment, lifting cranes,
transporting etc, positioning and fixing on pier with cement concrete of M55
grade. The weight shall be calculated assuming concrete density of 2.5 t/m³.
Shifting within the site/ yard is the responsibility of the contractor and shall
not be paid separately.
GMRC October 2026 Page 33 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
4 Providing M55 grade reinfoced cement concrete (as per technical Cum
specifications) for U-Girder of all simply supported spans (straight or curved) 12,598.21 36,729.36
in the casting yard including provision of shear connector for secondary pour
concrete (rail plinths), additional bars for earthing, bars/ strands/ hooks for
lifting of U-Girder, cutting of bars/ strands/ hooks after transportation and
sealing of lifting recess as specified in drawings, lifting the full spans from the
mould and shifting the same to the stacking yard. Reinforcement, strands,
debonding tubes, anchorages and sheathing shall be paid separately. Rate
shall include the cost of using reuired dosage of admixture for obtaining
required workability as per approval of Engineer in charge and all related
operations as required to complete the work as per drawings and
specifications. Rate includes cost of providing grooves/logo of client if
required (the ribs/grooves/logo in shutter if required, shall be as per
drawing). Minimum cement content shall be 440 kg/cum of concrete.
5 Providing HDPE debonding tubes for prestressing strands (to be cut-off RM
flush to concrete after casting), epoxy based sealing compound at edges of 32.74 4,59,060.00
strand and epoxy putty to avoid slurry ingress during concreting. The quantity
given is the net length of tubes without extra tube length required
during construction. Rate includes filling HDPE tubes with grease as specified
6 Transporting precast full span U-Girder from the casting yard to work site, MT
erection in position by using launching girder and shall not take any support 1,286.38 91,823.39
from ground / Road including the cost of all temporary supports, erection
equipment, lifting cranes, transporting etc, and positioning on bearings etc for
viaduct into completed structures conforming to required lines, grades and
dimensions complete as per drawings and specifications. The weight shall be
calculated assuming concrete density of 2.5 t/m³. Shifting within the site /
yard is the responsibility of the contractor and shall not be paid separately.U
Girder shall be launched/ Erected by using Lauching Girder and shall not take
any support from Ground or Road
GMRC October 2026 Page 34 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
7 Providing, pre-casting and curing precast RCC beams concrete (cement as per cum
technical specification) of all types I-Beam, Pie beams, L- beams, T- beams, 11,584.00
Rectangle beam etc. wherever required, complete of M40/20 grade for
Superstructure/Portal/Station Beams including shuttering and formwork etc.
Reinforcement shall be paid separately. Rate shall include cost of using
required dosage of admixture in concrete for obtaining required workability
as per approval of Engineer.
Minimum cement content shall be 390 kg/cum of concrete.
8 Providing, pre-casting and curing precast Pre tensioned / Post tensioned cum
beams concrete (cement as per technical specification) of all types I-Beam, 11,705.00 10,816.00
Pie beams, L- beams, T- beams etc. complete of M50/20 grade for
superstructure/Portal/Station Beams etc. including shuttering and formwork
etc. Reinforcement shall be paid separately. Rate shall include cost of using
required dosage of admixture in concrete for obtaining required workability
as per approval of Engineer.
Minimum cement content shall be 430 kg/cum of concrete.
9 Transporting and erection of I-Beam, Pie beams, L- beams, T- beams, RCC- MT
Beams, any other precast beams etc. into completed structures conforming 1,286.38 48,140.00
to required lines, installation of Spherical/POT PTFE/ all types of bearings etc.
as per the manual of bearing manufacturer under the supervision of bearing
manufacturer and as directed by the Engineer, grades and dimensions
complete as per drawings and specifications.
GMRC October 2026 Page 35 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
10 Providing M55 grade reinforced cement concrete (as per technical cum
specification) for casting and curing of Precast PSC I-Girder (Post 13,466.43
tensioned) with tapering width of all types (straight or curved spans as
per approved GAD) in the casting yard including provision of lifting the
girders from the mould and shifting the same to stacking yard. Prestressing
strands / cables / systems and reinforcement shall be paid separately. Rate
includes cost of lifting hook, using required dosage of admixture in
concrete for obtaining required workability as per approval of Engineer in
charge. Note : Type, size and number of shutter moulds shall be as per the
GFC drawings and nothing extra is payable.
Minimum cement content shall be 440 kg/cum of concrete.
11 Transporting Precast PSC I-Girder from the casting yard to work site, MT
erection in position including the cost of all temporary supprots, erection 1,052.49
equipments, lifting cranes, transporting etc, positioning on bearings and
fixing on pier. The weight shall be calculated assuming concrete density of
t/m3. Shifting within the site/yard is the responsibility of contracor and shall
not be paid separately.
12 Providing M50 grade reinfoced cement concrete (as per technical Cum
specifications) for Precast Slab panel at concourse / Platform levels of typical 12,736.00
station of all simply supported spans (straight or curved) and Precast
Staircases in the casting yard including provision of shear connector for
secondary pour concrete, additional bars for earthing, bars/ strands/ hooks
for lifting of precast slab, cutting of bars/ strands/ hooks after
transportation and sealing of lifting recess as specified in drawings, lifting
the full spans from the mould and shifting the same to the stacking
yard. Reinforcement, strands, debonding tubes, anchorages and sheathing
shall be paid separately. Rate shall include the cost of using reuired
dosage of admixture for obtaining required workability as per approval
of Engineer in charge and all related operations as required to complete
the work as per drawings and specifications.
Minimum cement content shall be 430 kg/cum of concrete.
GMRC October 2026 Page 36 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
13 Transporting precast Slab panel / Staircases from the casting yard to work MT
site, erection in position including the cost of all temporary supports, erection 898.00
equipment, lifting cranes, transporting etc, and positioning on bearings/ steel
plates etc conforming to required lines, grades and dimensions complete as
per drawings and specifications. The weight shall be calculated assuming
concrete density of 2.5 t/m³. Shifting within the site / yard is the
responsibility of the contractor and shall not be paid separately
14 Providing M60 grade reinforced cement concrete (as per technical cum
specification) for casting and curing of Precast pier arm / Cross Arm / 12,667.32
Cross Girder etc. of typical station (Post tensioned) including in-situ
connection with pier/column with tapering sction of all types in the
casting yard including provision of lifting the Pier arm from the mould and
shifting the same to stacking yard. Prestressing strands / cables / systems and
reinforcement shall be paid separately. Rate includes cost of lifting hook,
using required dosage of admixture in concrete for obtaining required
workability as per approval of Engineer in charge. Note : Type, size and
number of shutter moulds shall be as per the GFC drawings and nothing extra
Minimum cement content shall be 450 kg/cum of concrete.
15 Transporting Precast pier arm of typical station from the casting yard to work MT
site, erection in position including the cost of all temporary supprots, erection 1,475.35 17,613.75
equipments, lifting cranes, transporting etc, positioning on pier. The weight
shall be calculated assuming concrete density of 2.5 t/m3. Shifting within the
site/yard is the responsibility of contracor and shall not be paid separately.
GMRC October 2026 Page 37 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
16 Providing M55 grade reinforced cement concrete (as per technical cum
specification) for casting and curing of Precast PSC U-girder (Post 12,598.21
tensioned) with tapering width of all types (straight or curved spans as
per approved GAD) in the casting yard/at site including provision of lifting the
girders from the mould and shifting the same to stacking yard.
Prestressing strands / cables / systems and reinforcement shall be paid
separately. Rate includes cost of lifting hook, using required dosage of
admixture in concrete for obtaining required workability as per approval of
Engineer in charge. Note : Type, size and number of shutter moulds shall be as
per the good for construction (GFC) drawings and nothing extra is payable.
Minimum cement content shall be 440 kg/cum of concrete
17 Transporting Precast PSC U-girder (Post tensioned) from the casting MT
yard to work site, erection in position including the cost of all 1,286.38 14,782.50
temporary supprots, erection equipments, lifting cranes, transporting etc,
positioning on bearings and fixing on pier. The weight shall be calculated
assuming concrete density of 2.5 t/m3. Shifting within the site/yard is the
responsibility of contracor and shall not be paid separately.
18 Providing M40 grade reinforced cement concrete (as per techinical cum
specification) for concreting, curing, transporting, lifting, installing precast 11,118.46
parapet over Deck slab on both side of viaduct, including transition span
as per the drawing in all precast psc I-girder/steel girder spans (straight or
curved), with all leads. The cost includes shuttering, scaffolding, special
adjustable props for alignment of units, moulds, providing cut outs, bolts
& inserts for fixing signalling mast, curing, required dosage of admixture for
concrete, all handling, and fixing in position, etc. complete) with cast in situ
stitch concrete of same grade.Note: Payment at 50% of accepted rate on
casting and Balance 50% on completion of erection, stitch concrete and
related works. Rate includes cost of providing grooves/logo of client if
required (the ribs/grooves/logo in shutter if required, shall be as per
drawing).Minimum cement content shall be 390 kg/cum of concrete
GMRC October 2026 Page 38 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
19 Transportation, erection and installation of precast parapets over MT
already erected superstructure(psc i- girder/steel girder portion) conforming 1,037.82
to required lines, grades and dimension complete as per drawings and
specifications including cast in situ stitch concrete of same grade including
cast in situ stitch concrete of same grade. The weight shall be calculated
assuming concrete density of 2.5 t/m³. Shifting within the site/yard is the
responsibility of the contractor and shall not be paid separately
20 For all RCC items of schedule B3, minimum cement content has been Kg
specified. For any extra /less cement above or below the minimum specified 1,72,776.00
cement content, addition/deduction shall be paid under this items.
17 Load test of PSC I-Girder/ Pie Girder/T Girder spans of any length including Nos
making all arrangement and conducting satisfactory Load Testing of girder 2,87,681.63
(simply supported span constructed by I-Girders), erected in position on the
piers at site, including arrangement for application of actual design
serviceable vertical load, arrangement for measurement of deflection at
various salient points of the girder and submitting a report. The details
of placement, position, increment of load on the girder and installation
of measurement devices etc and additional measures (such as temperature
measures) shall be as directed by the Engineer. After completion of the test
all the materials used for the load testing shall be removed and site shall be
made clear. Rate shall include submission of method statement and third
party certification of the test.
GMRC October 2026 Page 39 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
18 Load Test of U-girder spans of any length including making all arrangement and Nos
conducting satisfactory Load Testing of U-girder, erected in position on the 2,87,681.63
piers at site, including arrangement for application of actual design serviceable
vertical load, arrangement for measurement of deflection at various salient
points of the girder and submitting a report. The details of placement, position,
increment of load on the girder and installation of measurement devices etc.
shall be as directed by the Engineer. After completion of the test all the
materials used for the load testing shall be removed and site shall be made
clear. Rate shall include submission of method statement and third party
certification of the test.
19 Load Test of Precast Slab Panel including making all arrangement and Nos
conducting satisfactory Load Testing of Precast slab panel, erected in position 2,87,681.63
on the piers at site, including arrangement for application of actual design
serviceable vertical load, arrangement for measurement of deflection at
various salient points and submitting a report. The details of placement,
position, increment of load on the girder and installation of measurement
devices etc. shall be as directed by the Engineer-in-Charge. After completion of
the test all the materials used for the load testing shall be removed and
site shall be made clear. Rate shall include submission of method statement
and third party certification of the test.
20 Load Test of Steel Plate girder/ OWG Span of any length including making Nos
all arrangement and conducting satisfactory Load Testing of steel girder span, 2,87,681.63
erected in position on the piers at site, including arrangement for application
of actual design serviceable vertical load, arrangement for measurement of
deflection at various salient points of the girder and submitting a report. The
details of placement, position, increment of load on the girder and installation
of measurement devices etc. shall be as directed by the Engineer-in-
Charge. After completion of the test all the materials used for the load testing
shall be removed and site shall be made clear. Rate shall include submission of
method statement and third party certification of the test.
GMRC October 2026 Page 40 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Schedule- B4 REINFORCEMENT AND PRESTRESSING STEEL
Item Description Unit Rate (excl. Quantity Amount (Rs.)
1 Providing TMT reinforcement steel of Fe-550D Grade MT 72,648.00 43271.96
conforming to IS1786 (latest) from approved list of supplier,
cost of material, royalty, transportation, handling, storing,
straightening, cutting, bending, tying, lap/butt welding,
placing in position including 18 gauge GI binding wire in
diamond form at each reinforcement junction in all structural
concrete at all heights and depths with all leads complete as
directed. Rate shall also include welding involved towards
stay current protection effects as per system approved by
Engineer-in- charge. The rate shall also include the cost of
binding wire, labour, all material, tools and plants, all leads, lift
etc. as per drawings and technical specification as directed by
Engineer-in-charge. The rate shall also include protective
coating as per technical specifications. This item is applicable for
all components of viaduct, station box area and other than
station box area (i.e. entry- exit structures. water tanks,
escalator, lift pits, staircases pump house etc)
GMRC October 2026 Page 41 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
(i) No laps, joints are permitted in rebars provided in
superstructures, piers, portals, pier arm, portal beams.
However, mechanical couplers are to be used without extra
(ii) For pile reinforcement, welding of lap joint shall be without
extra cost. Additional rings required for handling the rebar cage
shall be the responsibility of the contractor and shall not be
paid separately.
(iii) For other structural members, lap joints are permitted
for bar dia < 20 mm, (including 20 mm), else, mechanical
couplers are to be provided, where in rebar ends shall be cold
forged with die.
(iv) The cost includes all welding and providing mechanical
couplers, all types of laps, standard laps, chair, spacers, bend
deduction as per IS-SP 34 etc., as required and nothing extra is
payable on this account.
v) Steel considered for foundations is 30% (approximately) out
of total quantity for the purpose of processing variation of
GMRC October 2026 Page 42 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
2 Supplying and threading uncoated stress-relieved low relaxation MT 2442.15
steel confirming to IS: 14268, class - 2 from approved supplier
in precast pretensioned U-girder/slab panels/T-girder/L-
girder etc. for simply supported spans including spacers,
anchorages, stressing using approved system and all related
operations to complete the work. This item includes
providing and fixing all strands, de-bonding
arrangements (de-bonding tubes etc), required anchorages
for live and dead ends, stressing upto required level using
all tools and equipments and consumables cement grouting
as per specification and as directed by the Engineer-in-charge.
Rate includes filling de-bonding type with grease as specified in
ASTM and taping at the ends of the strand. Rate includes the
testing complete- load transfer, anchorage efficiency etc.
3 For U-girder/I-girder/Pier-cap/Cross-Arm/Portal beam/T- MT 1446.10
girder/pie-girder/L-girder etc.: Supplying and post tensioning
uncoated stress-relieved low relaxation steel conforming to IS
:14268, class 2 from approved supplier including providing
corrugated HDPE sheathing duct for cable system of 27K15,
19K15, 12K15, 7K15, 19K13, 12K13, 7K13 with couplers & vent
pipes, spacers, anchorages, stressing using 27K15, 19K15,
12K15, 7K15, 19K13, 12K13, 7K13 system and grouting,
recess filling, epoxy protection of anchorages and all related
operations to complete the work. (Note: the details shown
on the drawing may change and nothing extra will be paid to
the contractor on this account).
GMRC October 2026 Page 43 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Schedule B5- STRUCTURAL STEEL
Item Description U nit Rate (excl. Quantity Amount (Rs.)
1 Fabrication, Supply & Erection of Steel Plate girder spans. Procurement and fabrication MT 420.00
of steel members for Steel Plate girder Bridge Work using structural steel plates
(conforming to IS-2062-Grade B0 E 410) & structural steel rolled section (conforming to
IS-2062-Grade B0 E 250) to the required profile and shape as called for including the
shear studs profiled from the rods and erection of fabricated girders at specified site
locations. This item includes preparation of fabrication shop drawings, necessary
templates, all cutting, welding (using automatic submerged arc welding), grinding & all
equipments and operations etc required to complete the job.This item also includes all
tests on materials and welded fabricated parts as required. This item also includes
application of sand blasting on materials, application of primer and various coats of
internal and external painting in fabrication shop and site as per technical specification
in chapter of structral steel. This item includes all necessary equipments required to
complete the job including procurement, testing and supply of HSFG bolts (class 8.8 and
above) and its compatible nuts and washers.
This item also include erection of the fabricated plate girder to the required profile and
shape as called for at designated site location including loading, transportation of all
structural steel members from fabrication shop to site and unloading; preparation of
erection scheme drawings, setting of storage yard at site if required & all equipment and
operation etc.required to complete the job.This item also includes temporary
support/staging, staging braces, bracing to permanent work, strutting, tying or anchor
bolts, fasteners, welding, temporary foundations required for erection. This item also
includes the field bolting at erection site as per specifications including all connections
required between steel plate girder and bearings.
The structural steel to be used shall be procured from the approved manufacturer as
GMRC October 2026 Page 44 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
per contract provision. For payment purpose, nominal weight of the girder as per
drawing will only be considered.
Payment Terms shall be as follow: -
1) 50% shall be paid on fabrication of truss/girder components after inspection and
2) 10% shall be paid on Primer and painting of truss/girder components after inspection -
3) 5% shall be paid on receipt of fabricated and painted truss/girder components at site. -
4) 30% shall be paid on erection of truss/girder components by bolts and drifs and fixing -
permanent fastner.
5) 5% shall be paid on completion of balance work. -
Note:- Only steel which is erected and part of permanent structure will be measured - -
Note:- Any additional temporary structure which will be required for erection / -
launching of fabricated part or complete plate girder and the provision of the
connection of the same to the permanent work by welding the same or making holes as
per the approved launching scheme will be done by tenderer. No payment will be made
for such operations.
GMRC October 2026 Page 45 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
2 Providing , fabricating and erecting structural steel for hand/safety railing and other MT 750.00
structural members for viaduct including transition span consisting of tubular and
rolled sections profiled to require shape, inserts, plates with welded hold fasts for walk-
way, earth terminal plates, insert plates with welded hold-fasts, internal threaded
sleeves including MS bolts tightened by Torque wrench and primer coat & three coats
of enamel paint of approved make and colour as per specification and drawing, with
all lead and lifts and as per the directions of engineer. The rate includes required
surface preparation (sand blasting).
Note: All structural steel shall be Hot Dip galvanized conforming to IS-802 (Part II ),
IS:5358 and IS:4759. and the mass of zinc coating shall not be less than 500 g/sq.m.
3 Providing, fabricating and erecting structural steel inserts for cable tray, inserts for MT 340.00
cable ducts, inserts for signalling mast steel brackets over parapet for fixing street
light, earthing arrangement consisting of plates with welded hold fast, welded
headed nuts, internal threaded sleeve, studs in the form of U bars, bolts (class 4.6)
Note: All structural steel shall be Hot Dip galvanized conforming to IS-802 (Part II ),
IS:53548 and IS:4759 and the mass of zinc coating shall not be less than 500 g/sq.m.
Note: Some inserts fabricated by other agencies which have to be incorporated in the
precast segments/ cast- in-situ spans /piers/ pile cap/pile would have to be handed over
to the contractor for placement and fixing in the reinforcement cage/ shuttering before
concreting. No extra paymet will be made for such inserts.
4 Providing, fabricating and Erection of structural steel Foot Over Bridge (FOB) as per MT 810.00
grade defined in drawing i.e. E250 BR and tube section YST 310 complete. This rate also
includes preparation of shop drawings procurement of raw materials sand blasting,
painting, trail assembly and all other activities.This item includes all necessary
equipments required to complete the job including procurement, testing and supply of
HSFG bolts (class 8.8 and above) and its compatible nuts and washers. This item is also
applicable for station box and entry/exit structure wherever required as per the
direcction and apporval of engineer incharge.
GMRC October 2026 Page 46 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
i) Procurement and testing of Steel Quantities=45%
ii) On Completion of Fabrication of Steel Wotrk=20%
iii) Transporation and receipt of Fabricated Material at Site=10%
iv) Final Erection of Pre-Engineered Steel=25%
Schedule B6 - BEARINGS
Item Description Unit Rate (excl. GST) Quantity Amount (Rs.)
GMRC October 2026 Page 47 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
1 Elastomeric bearings
Supply and fixing in position true in line & level, Elastomeric
bearings of approved make, placing and fixing in location
as per specification/ drawings and as directed by the
Engineer in charge.
For elastomeric bearing below superstructure Cucm 0.54
For elastomeric bearing on sides of shear key stopper. It Cucm 0.54
includes vertical bearing with Teflon for slider arrangement
in Guided end of span.
2 Supply, fabrication, and installation of MS Wedge Plates KG
including cutting, welding, drilling, grinding and surface 276.70
treatment as per approved drawings and specifications.and
Fixing of MS Wedge Plate over Elastomeric Bearing for U-
3 Supplying to site lifting, installation, fixing and placing - -
of POT Cum PTFE Bearing and its components in
position during casting of Pier/Pedestal and
superstructure, incl. grouting of holes for anchor bolts
and underside of base plate with approved non-shrink
cementitious grout (e.g. Conbextra GP2 or equivalent) as
per specification. The design of POT cum PTFE bearings
shall be done by contractor as per loads, movements
etc. given in good for construction (GFC) drawings.
i) Free POT Bearing (Un-facored Design Vertical load = Nos
ii) Fixed POT Bearing (Un-facored DesignVertical load = Nos
1750 kN and Un-facored Design Horizontal load =600 40,275.43
GMRC October 2026 Page 48 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
iii) Longitudinal Guide POT Bearing (Un-facored Design Nos
Vertical load = 1750 kN and Un-facored Design 42,362.88
Horizontal load =600 kN)
iv) Transverse Guide POT Bearing (Un-facored Design Nos
Vertical load = 1750 kN and Un-facored Design 41,316.23
Horizontal load =600 kN)
Note: Price holds good for forces and movements varying -
by ± 25% for those indicated.
4 Spherical bearings Nos.
(i) Providing, fitting and fixing in position true in line and level 1,05,360.2
Spherical bearings , complete in all respect with all
components incl grouting with non-shrink cementitious
grout as per drawing and technical specifications.
Total Number of Fixed Bearing Max Vertical load = 5600 kN
and Horizontal load =1670 kN
(ii) Total Number of Free Bearing Max Vertical load = 5600 kN Nos.
(iii) Total Number of Slide Guide Longitudinal Bearing Max Nos.
Vertical load = 5600 kN and Horizontal load =1670 kN 1,04,696.6
(iv) Total Number of Slide Guide Transeverse Bearing Max Nos.
Vertical load = 5600 kN and Horizontal load =1670 kN 93,614.4
Schedule B7- MISCELLANEOUS ITEMS
Item Description Unit Rate (excl. Quantity Amount (Rs.)
GMRC October 2026 Page 49 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
1 Drainage Work
(i) Providing & fixing of double wall HDPE corrugated/plain
pipes and /or UPVC pipes (only external if provided) as
specified for rain water in superstructure of all types and
down take pipes, bends, couplers, upper receiving cap,
Tees and end cap etc. upto bottom of pier through
shear key as specified in drawings. This will be
required to be also provided at track crossing location for
laying power cable.
(d) Upper receiving cap -( hot dipped galvanised @650 nos 3,083.66 350.00
g/sqm steel) for 150mm Dia pipe
2 Expansion Joints - -
(i) Omega seal joint / Compression seal Expansion Joint RM 4,677.75 2,842.40
Providing and installing Omega seal joint /
Compression seal Expansion Joint conforming to
specification incl. provision of edge beams at end
edges of both adjoining precast diaphragm segments,
cast in situ units and all related operations as required to
complete the work as specified in specifications.
GMRC October 2026 Page 50 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
(ii) Strip Seal Joint – Providing and installing Single strip seal RM 9,045.00 100.00
joint conforming to latest revisions of MORTH circulars
incl. provision of edge beams at end edges of precast
diaphragm segments and cast in situ unit and all related
operations as required to complete the work as specified
in specifications. Gap for expansion joint installation is
upto 100mm & maximum variation in gap upto ± 50mm
as per instruction of engineer incharge.
3 Supply and fixing of 3mt x 0.855mm and 2.0mm thick FRP RM 2,133.86 1,200.00
sheets to cover the gap between the U-girders as per
approved drawings and direction of Engineer-in-charge.
This rate includes Material, Labour and required
4 Making of Cutouts (Core Cutting) in pre constructed RCC
/ CC for all grades / Block / Brick works for services
4.1 50 mm dia upto 250rnm long Nos 3,645.00 15.00
4.2 100 mm dia upto 250rnm long Nos 4,253.00 15.00
4.3 250 mm dia upto 250rnm long Nos 4,678.00 15.00
4.4 150 mm dia upto 250rnm long Nos 5,164.00 15.00
4.5 200 mm dia upto 250rnm long Nos 5,468.00 15.00
5 Rebaring as per below per below details
5.1 10mm dia. Rebar Fixing in 12mm dia. with hole depth of Nos 224.26 150.00
GMRC October 2026 Page 51 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
5.2 12mm dia. Rebar Fixing in 14mm dia. with hole depth of Nos 579.00 150.00
5.3 16mm dia. Rebar Fixing in 20mm dia. with hole depth of Nos 914.37 150.00
5.4 20mm dia. Rebar Fixing in 25mm dia. with hole depth of Nos 1,058.75 150.00
5.5 25mm dia. Rebar Fixing in 30mm dia. with hole depth of Nos 1,469.00 150.00
5.6 32mm dia. Rebar Fixing in 38mm dia. with hole depth of Nos 1,653.00 150.00
6 Providing and fixing of cable support GI bracket (Hot Dip Kg 121.50 1,000.00
Galvanized as per drawing for laying of system cables in
the platform area at elevated station. The rate shall
include cost of all required materials, Hot Dip Galvanized
fabrication, transportation at site, fasteners and fixing in
viaduct holes already provided by Civil contractor for
cable fixing/tieing, complete job in terms of approved
drawings and as per direction of Engineer-in-charge.(Cost
of Fasteners paid Separately)
7 Providing, fabricating, supplying, and fixing lifting hook Nos 3,378.66 9.00
arrangement in ASS (Auxiliary Sub-Station) / TSS
(Traction Sub-Station) room for lifting and maintenance
of equipment such as transformers, panels, or other
heavy electrical equipment, including hook, anchoring
system, fixing arrangement, and all associated works,
complete as per approved drawings and instructions of
GMRC October 2026 Page 52 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
8 Providing and applying two-component polysulphide RM 569.00 500.00
sealant in construction/expansion joints of concrete,
masonry, metal, glass or other surfaces, including joint
preparation, primer application, backing rod where
required, sealant application and finishing, complete in all
respects as per approved drawings, manufacturer’s
specifications and instructions of the Engineer.
9 Providing, casting, supplying, transporting and erecting Sqmt 2,235.60 1,000.00
precast reinforced cement concrete (RCC) boundary wall
panels with RCC posts, including excavation, foundation,
erection, fixing of panels, jointing, finishing and all
associated works, complete in all respects as per
approved drawings and instructions of the Engineer.
10 Providing, Installing and fixing in position holding down MT 1,52,741.00 9.00
bolts of various sizes and lengths, as per drawings and
instructions, including making of pockets in foundations,
column heads, beams et. / Providing, fabricating to
required profile and shape, transporting, erecting and
fixing in position MS members made of built-up sections/
rolled or hollow structural steel sections to be used as
fixtures/supports/hangers etc. for system/roofing
contractors at any location or as directed by Engineer in
charge. Providing, fabricating, installing and fixing in
position any additional structural connections for
signages, gutters, or required by the system contractors
using standard plate sections welded & built up section,
tubes, square, rectangular pipe section, rolled sections
such as angles, channels etc.
11.0 Masonry Work
GMRC October 2026 Page 53 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
11.1 Providing & laying Autoclaved Aerated Cement Blocks Cum 6781.00 5,792
masonry with 100mm/150mm/200mm/300mm thick
AAC blocks in all levels with RCC band at sill level and
lintel level with approved block laying polymer modified
adhesive mortar all complete as per direction of
Engineer-in-Charge. (The payment of RCC band and
reinforcement shall be made for seperately).
11.2 Providing and laying Damp-proof course 40 mm thick Sqm 366.00 196
with cement concrete 1:2:4 (1 cement : 2 coarse sand :
graded stone aggregate 12.5 mm nominal size).
11.3 Reinforced cement concrete work in beams, suspended Cum 10238.00 562
floors, roofs having slope up to 15° landings, balconies,
shelves, chajjas, lintels, bands, plain window sills,
staircases and spiral stair cases up to floor five level
excluding the cost of centering, shuttering, finishing and
reinforcement with 1:2:4 (1 cement : 2 coarse sand :
graded stone aggregate 20 mm nominal size).
11.4 Centering and shuttering including strutting, propping - -
etc. and removal of form for all heights :
11.4.1 Lintels, beams, plinth beams, girders, bressumers and Sqm 656.00 5,836
11.5 Brick work with common burnt clay F.P.S. (non modular) - -
bricks of class designation 7.5 in foundation and plinth
11.5.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 6347.00 82
GMRC October 2026 Page 54 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
11.6 Brick work with common burnt clay F.P.S. (non modular) - -
bricks of class designation 7.5 in superstructure above
plinth level up to floor V level in all shapes and sizes in :
11.6.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 8103.00 84
11.7 Half brick masonry with F.P.S. brick of class designation - -
75 in foundations and plinth in.
11.7.1 Cement mortar 1:3 (1 cement : 3 coarse sand) sqm 830.00 82
11.8 Half brick masonry with F.P.S. bricks of class designation - -
75 in superstructure above plinth level up to floor V level.
11.8.1 Cement mortar 1:3 (1 cement :3 coarse sand) sqm 1024.00 82
11.9 Extra for providing and placing in position 2 Nos 6mm sqm 94.00 164
dia. M.S. bars at every third course of half brick masonry
11.10 Providing and laying in position cement concrete of - -
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
11.10.1 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from cum 7011.00 82
natural sources: 4 graded stone aggregate 20 mm
nominal size derived from natural sources)
GMRC October 2026 Page 55 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
11.11 Providing and laying in position ready mixed or site - -
batched design mix cement concrete for plain cement
concrete work; using coarse aggregate and fine
aggregate derived from natural sources, Portland
Pozzolana/Ordinary Portland /Portland Slag cement,
admixtures in recommended proportions as per IS:
to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength;
including pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of centering,
shuttering and finishing as per direction of the engineer-
in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified - -
cement content in design mix shall be payable separately.
In case the cement content in design mix is more than
110% of the minimum specified cement content, the
contractor shall have discretion to either re-design the
mix or bear the cost of extra cement.
11.11.1 All works above plinth and upto floor V level - -
a) Concrete of M10 grade with minimum cement content of cum 8179.00 42
b) Concrete of M15 grade with minimum cement content of cum 8313.00 42
GMRC October 2026 Page 56 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
11.12 Providing and fixing up to floor five level precast cement - -
block, including hoisting and setting in position with
1:3 (1 cement : 3 coarse sand), cost of required centering,
11.12.1 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from cum 15919.00 408
natural sources : 3 graded stone aggregate 20 mm
nominal size derived from natural sources).
12 Plaster work - -
12.1 12mm cement plaster of mix: - -
12.1.1 1:6 (1 cement : 6 fine sand). (at all levels and locations) Sqm 297.00 54,174
12.2 15 mm cement plaster on rough side of single or half - -
brick work wall of mix:
12.2.1 1:4 (1 cement : 4 fine sand) (at all levels and locations) Sqm 356.00 21,412
12.3 6 mm cement plaster of mix : - -
12.3.1 1:3 (1 cement: 3 fine sand) (at all levels and locations) Sqm 268.00 46,170
13 Providing & fixing G.I. Hexagonal chicken wire mesh of Sqm 31.50 25,920.00
size 12mm x 20 gauge conforming to IS : 3150 at the
junction of dissimilar surfaces of brick / block masonry
wall and RCC column / beams and the like including
necessary "U" nails / screws with cleats for fixing,
overlapping etc. complete all as per specification and as
directed by the Engineer for all height and all locations.
GMRC October 2026 Page 57 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
GMRC October 2026 Page 58 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Schedule B8 - Structural Steel for Open Web Girder
Item Description Unit Rate (excl. Quantity Amount
1 Supply and Fabrication of steel through type TRUSS spans as per the approved drawings of MT
superstructure of the Bridge over Railway lines with contractor's own structural steel plates 1,81,543.22 682.50
(conforming to IS-2062-Grade B0 E 410) & structural steel rolled section (conforming to IS-2062-
Grade B0 E 250) quality with all welds, rivets, nuts bolts, etc. with contractor's own materials,
fabrication, machinery, templates, fixtures, equipments, tools and plants, transportation,
skilled/unskilled labour, all leads and lifts, Descent, loading, unloading, crossing one or more
Railway track if required, etc. complete and as per RDSO drawings & specifications by RDSO
approved venders only.The work shall be carried out during block periods sanction by railway. No
extra payment shall be made on this account.
The rate is inclusive of transportation of fabricated truss parts to site by contractor's own means
The structural steel to be used shall be procured from the Railway/RDSO approved manufacturer
only. Work has to be done as per drawings and specifications approved by Railway.
1) The fabrication of truss must be got done from RDSO approved firms only.
2) For payment purpose, nominal weight of the truss as per drawing will only be considered.
Metalising TRUSS components such as cross girders, top chord channels, bracing etc. as directed
by Engineer with aluminium spray not less than two layers after preparing surface by sand/grit
blasting as per provision laid in Appendix VI of IRS B 1 code (latest alteration) including one coat
wash primer (IS-5666) one coat zinc chrome primer (IS-104) and two coats of aluminium paint (IS-
2339) with approved paint conforming to IS specification for fabrication and erection of steel
girder bridge (IRS B 1) with Contractor's own materials, tools and plants, labour, loading,
unloading, transportation, handling, re-handling if any, including all lead, lifts, Descents, crossing
of track/obstruction etc. complete in all respect and as per direction of the Engineer.
GMRC October 2026 Page 59 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Assembling, Welding, Erecting, Riveting, Launching, bolting by HSFG bolts(class 8.8 grade and
above) wherever required (as per approved drawings) with contractor's rivet materials, weld
materials, HSFG bolts, service bolts, erection and launching of Truss span to Railway's approved
drawings with other ancillary steel structures fixed to the truss where necessary in proper level
and alignment and as per technical specifications. The cost includes cost of launching steel nose/
launching steel girder of required length.
Schedule-C1 Electrical System Works
S.No Description of Item Unit Rate QUANTITY Amount
SWITCH BOARDS/PANELS
Design, Fabrication, Assembling, Wiring, Supply, installation, testing &
commissioning of LT Panels fabricated out of CRCA sheet steel 2 mm
thick for structural members and 1.6 mm thick for doors and covers in
cubical compartmentalized free standing floor mounted, dust and
vermin proof with reinforcement of suitable size ISA / ISMC / ISMB / flats
wherever necessary. Panels shall be treated with all anticorrosive
process and powder coated (Minimum thickness 80 micron) with
approved shade. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 Hz
power supply system to withstand rated symmetrical fault level at 415 V
including interconnections, bonding to earth etc. Panels shall be
provided with 25% spare space, space heaters, compartmental lights,
lifting hooks as required and 2 Nos of Earthing Terminals. All inter wiring
shall be with suitable stranded copper conductor FRLSH insulated wire.
The panels shall confirm to IP-54. Galvanized hardwares with Zinc
passivation shall be used.
GMRC October 2026 Page 60 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
a The Electrical Panels shall be a minimum of Form 4b type Type 5 in
accordance with BS EN61439-1/IEC 61439-2 . Internal arc test as per IEC
61641 complete as per specification.
b The panels shall be provided with detachable gland plates of 3mm
thickness for entry of cables from the top/bottom as required.
c All live accessible parts shall be shrouded and all equipment shall be
finger touch proof. SMC/DMC shrouds and busbars supports shall be
suitably spaced.
d The panel shall have tinned copper busbars with bar type feeder
connections, spacers etc.and neutral busbar shall be of 100% capacity.
Bus Bar Sizing calculations shall be submitted for approval of GMRCL
e All components shall be connected to a common internal copper earth
bus bar of minimum size 50mm x 6mm.
g Hinged doors with Neoprene type gaskets & Triangle key lock facility
shall be provided on Doors and all outgoing feeders with switch handles
lockable in OFF position.
h Each incomer and outgoing feeder shall be provided with suitably rated
MCB controlled multiple LED lamps (Red, Yellow, Blue) for Phase
indication and (Red, Green, Amber) for ON, OFF & Trip status with all
required accessories suitable for 230 VAC operation as approved.
j The makes of components and accessories shall be unique for all the
panels under this contract in order to have uniformity and
standardization.
k All MCCBs shall be current limiting type microprocessor based releases
having continuously adjustable current setting in the range of 0.4 to
and 2-10 times of short circuit, rated for requisite specified Service short
circuit breaking capacity (Ics) suitable for isolation conforming to latest
IS/IEC60947-2 duly marked on MCCB, at operating voltage (Ue) of 415 V,
insulation voltage (Ui) 1100 V and with trip free mechanism, handle
indicating ON/OFF/tripped position. The breaking capacity as mentioned
in items of BOQ below. Breakers must have Ics = Icu = Icw.
GMRC October 2026 Page 61 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
l All MCCB's shall be 4 pole with Over Load Protection,Short circuit and
Earth Fault sensing. MCCBs shall be suitably designed to provide
protection of motors, cables, busbars to suit rated current, unbalanced
power distribution as required and with front adjustable overload and
short circuit releases and minimum electrical endurance shall be of the
order of suitable operation cycles as specified in the Technical
Specification.All MCCBs shall be provided with Rotary handle and
spreader links for termination. All 4P MCCB has inbuilt feature of earth
fault protection, whereas all TPN MCCB's (Expect Motor Starters & DRPC
Panels) shall have external CT for neutral overload protection and earth
fault protection
m All the Incomer, bus couplers of switch boards/ panels shall be provided
with potential free contacts for connectivity to PLC for ON/OFF status
and control, as required for BMS .All Incomer, bus couplers of switch
boards/ panels shall be provided with Multi function Meters with RS
for BMS connectivity. All the RS -485 devices of Panels/ DBs shall be
looped into a single terminal/ port for each panels for easy integrations
with BMS. All internal Wiring & required accessories are in scope of
Panel/ DB Vendor.
n MCBs shall conform to IEC898/IS 8828 (latest) and, with breaking
capacity 10 kA at 415 V AC, current limiting type lower power loss appx
40 - 70% of the stipulated value and suitable for magnetic releases
operating between 3 to 5 times rated current for normal power
distribution application and 5 to 10 times rated current for motor
application duty, with minimum Electrical endurance of the order of
20000 operation cycles. All MCCBs shall be provided with Rotary handle
and spreader links for termination complete as required.
o Panel design shall be compact to economies the room space available.
p All incomer ACB's shall be provided with minimum 6 NO + 6 NC contacts
and there should be provision to add min. 6 NO+ 6 NC Auxiliary contacts.
q All 4-pole ACBs, MCCBs & MCBs shall have fully rated neutral pole.
GMRC October 2026 Page 62 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
r The panels shall be provided with polymer based fire trace tube system.
Scheme of fire trace tube system shall be got approved by GMRCL
Engineer before proceeding with manufacturing and assembly. Cost for
this item shall be paid under suitable Item of Fire fighting works.
Contractor shall interface with OEM of panel and Panel flooding system
and ensure that the provision is made during fabrication of panel itself.
s Internal control wiring in the Starters shall be done with FRLSH PVC
insulated cables of adequate size. Internal wiring, contactors, relay
contacts, push button contacts should be rated not less than 2.5 sq. mm.
All MCCB shall be motorized with RS 485 type communication port for
BMS/SCADA functioning.
u Switch boards / panels shall be provided with Automatic clean agent gas
flooding arrangement with a fire detection tube system, as per the
specifications complying with the latest Indian Standards (IS:15517) and
NFPA-2001. An Automatic gas flooding system shall be provided with
manual overriding system with regulated valve arrangement including
control & Monitoring module for opening or closing the cylinder as and
when it is called for. A bank of clean agent gas cylinders with necessary
tubing shall be provided.
v Each Panel/DB as required shall be capable of real-time data of Status,
Control & Monitoring through Ethernet/TCP IP Port / RS 485 through
open protocol (IEC 60870-5104 shall be preferred),
w The Digital Multifunction meter shall have inbuilt bar graph for showing
the percentage loading in each phase and inbuilt LCD display to show all
the power parameters like A, V, W, VAR, VA, Wh, Vah, VARh & Hz. with
BMS connectivity.
x All motorized MCCBs /ASTS MCCBs to be provided with 230V, 50Hz
control supply as required including conversion needed if any from UPS
y The schematic drawings are to be read in conjunction with BOQ &
Technical specifications.
GMRC October 2026 Page 63 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
z The load demand, cable size and route length are indicative only and
contractor shall evaluate the adequacy of the switch gear and voltage
aa All switch boards/ panels shall be provided with necessary Surge
Protection for Transient Over Voltages due to Lightning and switching
surges shall be incorporated with suitable rating Surge Arresters under
Class-1, Class-2, Class-3 of IEC
ab The bus bar shall be designed for all the switch boards / panels meeting
application duty requirement provided with insulations/ bus bar
supports system withstanding the thermo dynamic stresses
ac All panel shall have IP 54 protection for indoor application and IP 65 for
outdoor application.
ad Class-B SPDs shall be provided in all panels and Distribution Boards to
meet all functional requirement as per IEC 61643-12 or latest.
1.1 MAIN DISTRIBUTION BOARD (MDB)
A Transformer - I Incoming
1 No. of 1000 A, 415V, 50kA, 4P Electrically operated (fully motorized)
fully draw out (EODO) type ACB with built in Microprocessor based
release unit for Over Current, Short circuit and earth fault protection
with adjustable setting and time log facility for each of the fault for
achieving discrimination along with distinct fault indication through LED
display. ACB shall be provided with continuous rated shunt trip release
suitable for 240 VAC operation, suitable handles to operate ACB
manually and spring charging device suitable for 1 phase, 240 VAC
operation, NO/NC contacts for interlocks and indications. ACB shall have
in-built compatibility through open protocol like Modbus for SCADA/BMS
connectivity (RS485) along with following accessories.
GMRC October 2026 Page 64 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
i) 1 No. of Multi Function Meter of accuracy class 1 with all required to
measure and display the Electrical quantities like, Current, Voltage,
Active Energy-KWH, Reactive Energy-kVAH, frequency, Maximum
Demand-KVA/KW, Total Hormonic Distortion & power factor etc. with
facility conforming to specifications and latest IEC standards with
necessary Circuit MCBs and suitable size summating CTs for metering
supporting SCADA/BMS connectivity
ii) 1 No. 0-1000A Digital Ammeter with selector switch and Required set of
CTs, MCBs and Accessories
iii) 1 No. 0-500V Digital Voltmeter with selector switch and Required set of
MCBs and Accessories
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) 3 Nos. of cast resin current transformers of 1000/5 ratio with 15 VA
Burden & Class 5P10 for protection
vii) 3 Nos. of cast resin current transformers of 1000/5 ratio with 15VA
burden and Class 1 for measurement
viii) 3 nos. cast resin current transformers of 1000/5 ratio with 15VA burden
and Class 1 for APFC relay
ix) 1 set of Under Voltage Relay with complete accessories.
x) 1 set of Over Voltage Relay with complete accessories.
xi) 1 set of Instantaneous Over Currrent Relay (50)
xii) 1 set of IDMT Over Current Relay (51)
xiii) 1 set of Earth Fault protection relay (51N)
xiv) 1 set of Ground fault protection relay (50N)
xv) 1 set of reverse power protection and phase sequence protection
xvi) Auxiliary contacts required for necessary interlocking of Transformers,
HT & LT breakers.
xvii) Class-B SPDs shall be provided in panel as per IEC 61643-12 or latest.
GMRC October 2026 Page 65 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
xviii) Contractor shall provide earmarked potential free terminals for SCADA
signals as per specification & requirements.
B Transformer - II Incoming
1 No. of 1000 A, 415V, 50kA, 4P Electrically operated (fully motorized)
fully draw out (EODO) type ACB with built in Microprocessor based
release unit for Over Current, Short circuit and earth fault protection
with adjustable setting and time log facility for each of the fault for
achieving discrimination along with distinct fault indication through LED
display. ACB shall be provided with continuous rated shunt trip release
suitable for 240 VAC operation, suitable handles to operate ACB
manually and spring charging device suitable for 1 phase, 240 VAC
operation, NO/NC contacts for interlocks and indications. ACB shall have
in-built compatibility through open protocol like Modbus for SCADA/BMS
connectivity (RS485) along with following accessories.
i) 1 No. of Multi Function Meter of accuracy class 1 with all required to
measure and display the Electrical quantities like, Current, Voltage,
Active Energy-KWH, Reactive Energy-kVAH, frequency, Maximum
Demand-KVA/KW, Total Hormonic Distortion & power factor etc. with
facility conforming to specifications and latest IEC standards with
necessary Circuit MCBs and suitable size summating CTs for metering
supporting SCADA/BMS connectivity
ii) 1 No. 0-1000A Digital Ammeter with selector switch and Required set of
CTs, MCBs and Accessories
iii) 1 No. 0-500V Digital Voltmeter with selector switch and Required set of
MCBs and Accessories
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) 3 Nos. of cast resin current transformers of 1000/5 ratio with 15 VA
Burden & Class 5 P10 for protection
vii) 3 Nos. of cast resin current transformers of 1000/5 ratio with 15VA
burden and Class 1 for measurement
GMRC October 2026 Page 66 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
viii) 3 nos. cast resin current transformers of 1000/5 ratio with 15VA burden
and Class 1 for APFC relay /AHF.
ix) 1 set of Under Voltage Relay with complete accessories.
x) 1 set of Over Voltage Relay with complete accessories.
xi) 1 set of Instantaneous Over Currrent Relay (50)
xii) 1 set of IDMT Over Current Relay (51)
xiii) 1 set of Earth Fault protection relay (51N)
xiv) 1 set of Ground fault protection relay (50N)
xv) 1 set of reverse power protection and phase sequence protection
xvi) Auxiliary contacts required for necessary interlocking of Transformers,
HT & LT breakers.
xvii) Class-B SPDs shall be provided in panel as per IEC 61643-12 or latest.
xviii) Contractor shall provide earmarked potential free terminals for SCADA
signals as per specification & requirements.
1 No. of 1000 A, 415V, 50kA, 4P draw out Electrically operated (fully
motorized) fully draw out (EODO) type ACB with built in Microprocessor
based release unit for Over Current, Short circuit and earth fault
protection with adjustable setting and time log facility for each of the
fault for achieving discrimination along with distinct fault indication
through LED display. ACB shall be provided with continuous rated shunt
trip release suitable for 240 VAC operation, suitable handles to operate
ACB manually and spring charging device suitable for 1 phase, 240 VAC
operation, NO/NC contacts for interlocks and indications. ACB shall have
in-built compatibility through open protocol like Modbus for SCADA/BMS
connectivity (RS485) along with following accessories.
i) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps and
ON/OFF push buttons.
ii) Auxiliary contacts required for necessary interlocking of Transformers,
HT< breakers.
GMRC October 2026 Page 67 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
iii) Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
iv) Two incomers shall be interlocked electrically & mechanically, so as only
any 02 out of 03 ACBs can be closed at any time.
Electrolytic high conductivity tinned copper three phase and neutral
busbars rated at >1000 A as per specification, suitable to withstand
symmetrical fault level of 50 kA at 415 V with 100% rated neutral busbar.
a) 1 nos. 400A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent,
short circuit and earth fault releases & each having 1- set Red/Green
ON/OFF indicating lamps, & 3 nos. cast resin current transformers of
400/5 ratio with 15 VA Burden & Class 1.0 for Ammeter with Ammeter
selector Switch.
b) 3 nos. 250A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent,
short circuit and earth fault releases & each having 1- set Red/Green
ON/OFF indicating lamps, & 3 nos. cast resin current transformers of
250/5 ratio with 15 VA Burden & Class 1.0 for Ammeter with Ammeter
selector Switch .
c) 3 nos. 160A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent,
short circuit, and earth fault releases & each having 1- set Red/Green
ON/OFF indicating lamps, 3 nos. cast resin current transformers of 160/5
ratio with 15 VA Burden & Class 1.0 for Ammeter with Ammeter selector
d) 1 nos. 100A, 415V, Ics=35 kA, Four Pole MCCB with variable overcurrent,
short circuit and earth fault releases & each having 1- set Red/Green
ON/OFF indicating lamps & 3 nos. cast resin current transformers of
100/5 ratio with 15 VA Burden & Class 1.0 for Ammeter with Ammeter
selector Switch
GMRC October 2026 Page 68 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
a) 2 nos. 400A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent,
short circuit and earth fault releases & each having 1- set Red/Green
ON/OFF indicating lamps & 3 nos. cast resin current transformers of
400/5 ratio with 15 VA Burden & Class 1.0 for Ammeter with Ammeter
selector Switch.
b) 3 nos. 160A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent,
short circuit and earth fault releases & each having 1- set Red/Green
ON/OFF indicating lamps & 3 nos. cast resin current transformers of
160/5 ratio with 15 VA Burden & Class 1.0 for Ammeter with Ammeter
selector Switch.
c) 3 nos. 250A, 415V, Ics=35kA, Four pole MCCB with variable overcurrent,
short circuit and earth fault releases & each having 1- set Red/Green
ON/OFF indicating lamps & 3 nos. cast resin current transformers of
250/5 ratio with 15 VA Burden & Class 1.0 for Ammeter with Ammeter
selector Switch.
d) 2 nos. 100A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent,
short circuit and earth fault releases & each having 1- set Red/Green
ON/OFF indicating lamps & 3 nos. cast resin current transformers of
100/5 ratio with 15 VA Burden & Class 1.0 for Ammeter with Ammeter
selector Switch.
SITC of MAIN DISTRIBUTION BOARD (MDB) No.
1.2 Emergency Main Distribution Board (EMDB)
A Incomer (Normal supply)
a) Incoming from B1 with 400A, 415V , Ics = 35kA, FP, Motorised MCCB
complete with variable overcurrent ans short circuit releases for Normal
GMRC October 2026 Page 69 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
b) Incoming from B2 with 400A, 415V , Ics = 35kA, FP, Motorised MCCB
complete with variable overcurrent ans short circuit releases for Normal
c) Automatic changeover system complete
B INCOMING FROM DG PANEL
a) 1 no. 400A, 415V , Ics = 35kA, FP, Motorised MCCB complete with
variable overcurrent ans short circuit and short circuit releases for
b) Automatic changeover system complete
Electrolytic high conductivity tinned copper three phase and neutral
busbars rated at > 400 A as per specification, suitable to withstand
symmetrical fault level of 35 kA at 415 V with 100% rated neutral busbar.
a) All incomers shall be interlocked electrically & mechanically with
contactor based automatic changeover system so that only one supply is
switched on at a time and fail safe restoration.
D Outgoing Units
a) 4 nos. 125 A, 415V, Ics=35 kA, TPN MCCB with fixed neutral and variable
overcurrent, short circuit and earth fault releases with 1 set each of
MCB controlled Breaker ON/OFF/TRIP and phase indicating lamps.
b) 2 no. 200 A, 415V, Ics=35 kA, TPN MCCB with fixed neutral and and
variable overcurrent, short circuit and earth fault releases with 1 set
each of MCB controlled Breaker ON/OFF/TRIP and phase indicating
c) 12 no. 63 A, 415V, Ics=25 kA, TPN MCCB with fixed neutral and and
variable overcurrent, short circuit and earth fault releases with 1 set
each of MCB controlled Breaker ON/OFF/TRIP and phase indicating
GMRC October 2026 Page 70 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
1 No, 230V, AC operated integral type Digital meter with RS485 port for
measuring Amps ,Voltage, Energy, kWH, kVAR, frequency, Maximum
Demand & power factor etc conforming to specifications, latest IEC/
EMC and EMI standards/criterion, with necessary Circuit MCBs and
suitable size summating CTs for above incomers metering supporting
SCADA/BMS connectivity.To be equipped with source power sensing,
automatic changeover, 3-phase Under-voltage protection, Phase
Sequence Protection and test facility inbuilt in the controller and RS
communication port with compatibility for interfacing with BMS/SCADA.
The trip unit of MCCB shall be with adjustable Overload protection, Short
Circuit protection, shunt trip coil, auxiliary contacts for ON, OFF, TRIP
indication etc. as per drawing and specifications along with 3 sets of
following accessories.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to
measure and display the Electrical quantities like, Current, Voltage,
Active Energy-KWH, Reactive Energy-kVAH, frequency, Maximum
Demand-KVA/KW, Total Hormonic Distortion & power factor etc. with
facility conforming to specifications and latest IEC standards.
ii) 1 No. 0-400A Digital Ammeter with selector switch and Required set of
CTs, MCBs and Accessories
iii) 1 No. 0-500V Digital Voltmeter with selector switch and Required set of
MCBs and Accessories
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) Auxiliary contacts required for necessary interlocking of breakers.
vii) 3 Nos. of cast resin current transformers of 400/5 ratio with 15VA
burden and Class 1 for measurement.
viii) Class-B, SPDs shall be provided in panel as per IEC 61643-12 or latest.
ix) Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
GMRC October 2026 Page 71 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
SITC of Emergency Main Distribution Board (EMDB) No.
1.3 Design, Supply, installation, testing commissioning of Main Lighting &
Power panel (MLPP) complete as per specifications & Drawing with
Main Lighting & Power panel (MLPP)
A Incomer (from MDB-1)
2 No. of 100 A, 415V, 25kA, 4P MCCB with changeover switch built in
Microprocessor based release unit for Over Current, Short circuit and
earth fault protection with adjustable settings. The breaking capacity of
MCCB shall be Icw=Icu. MCCB shall have in built compatibility through
open protocol like Modbus for SCADA/BMS connectivity (RS485) along
with following accessories.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to
measure and display the Electrical quantities like, Current, Voltage,
Active Energy-KWH, Reactive Energy-kVAH, frequency, Maximum
Demand-KVA/KW, Total Hormonic Distortion & power factor etc. with
facility conforming to specifications and latest IEC standards. MFM shall
have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
ii) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
iii) 1 set of MCB controlled phase indicating lamps for all three phases.
iv) Amber healthy trip indicating lamps
v) 3 Nos. of cast resin current transformers of 100/5 ratio with 15VA
burden and Class 1.0 for measurement
vi) Auxiliary contacts required for necessary interlocking.
GMRC October 2026 Page 72 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
vii) Class-B SPDs shall be provided in all panels and Distribution Boards to
meet all functional requirement as per IEC 61643-12 or latest.
viii) Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
Electrolytic high conductivity tinned copper three phase and neutral
busbars rated at >100 A as per specification, suitable to withstand
symmetrical fault level of 25 kA at 415 V with 100% rated neutral busbar.
a) 9 Nos. of 10A/20A , 415V, 10kA, TPN MCB, with fixed neutral and
variable overcurrent, short circuit releases. Suitably rated AC3 Duty
power contactor of with necessary NO & NC auxiliary contacts as
required for operation through BMS, Auto/ manual selector switch, 1 set
of MCB controlled Breaker ON/OFF/TRIP indicating lamps, complete as
required and approved.
SITC of Main Lighting & Power panel (MLPP) No. 595785.85
1.4 Design, Supply, installation, testing commissioning of Emergency (UPS)
Power panel complete as per specifications & Drawing with following:
Emergency (UPS) Power panel (UPP)
a) 2 Nos. of 63 A, 415V, 25kA, 4P MCCB with built in Microprocessor based
release unit for Over Current, Short circuit and earth fault protection
with adjustable settings. The breaking capacity of MCCB shall be Icw=Icu.
MCCB shall have in built compatibility through open protocol like
Modbus for SCADA/BMS connectivity (RS485) each along with following
GMRC October 2026 Page 73 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to
measure and display the Electrical quantities like, Current, Voltage,
Active Energy-KWH, Reactive Energy-kVAH, frequency, Maximum
Demand-KVA/KW, Total Hormonic Distortion & power factor etc. with
facility conforming to specifications and latest IEC standards. MFM shall
have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
ii) 3 Nos. of cast resin current transformers of 40/5 ratio with 15VA burden
and Class 1.0 for measurement
iii) Auxiliary contacts required for necessary interlocking.
iv) Class-B SPDs shall be provided in all panels and Distribution Boards to
meet all functional requirement as per IEC 61643-12 or latest.
v) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
vi) 1 set of MCB controlled phase indicating lamps for all three phases.
vii) Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
Electrolytic high conductivity tinned copper three phase and neutral
busbars rated at >63 A as per specification, suitable to withstand
symmetrical fault level of 25 kA at 415 V with 100% rated neutral busbar.
a) 11 Nos. of 20A, 230V, 10kA, DP MCB, with fixed neutral and variable
overcurrent & short circuit releases. Suitably rated AC3 Duty power
contactor of with necessary NO & NC auxiliary contacts as required for
operation through BMS, Auto / manual selector switch, 1 set of MCB
controlled Breaker ON/OFF/TRIP indicating lamps, complete as required
GMRC October 2026 Page 74 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
b) 4 Nos. of 10A, 230V, 10kA, DP MCB, with fixed neutral and variable
overcurrent & short circuit releases. Suitably rated AC3 Duty power
contactor of with necessary NO & NC auxiliary contacts as required for
operation through BMS, Auto / manual selector switch, 1 set of MCB
controlled Breaker ON/OFF/TRIP indicating lamps, complete as required
c) 3 Nos. of 20A, 230V, 10kA, DP MCB, with fixed neutral and variable
overcurrent & short circuit releases. Suitably rated AC3 Duty power
contactor of with necessary NO & NC auxiliary contacts as required for
operation through BMS, Auto / manual selector switch, 1 set of MCB
controlled Breaker ON/OFF/TRIP indicating lamps, complete as required
SITC of Emergency (UPS) Power panel (EPP) No. 798368.6
1.5 Design, Supply, installation, testing commissioning of Fire & Water
Pump Panel (FWP) complete as per specifications, Drawings and as per
following details:
1.5.1 Fire & Water Pump Panel (FWP)
a) 2 Nos. 200A, 35 kA, 4 pole, motorized MCCBs with automatic
changeover system with source power sensing with provision for
receiving two independent source power supply (one incoming supply
from EMDB and one incoming supply from DG-AMF panel) , electrically
and mechanically interlocked with common base frame and controller
having selector switch for automatic & manual operation on both the
sources., 3 phase Under - voltage protection and Phase Sequence
Protection inbuilt in the controller and RS 485 communication port with
compatibility for interfacing with BMS/SCADA. The trip unit of MCCB
shall be with adjustable Overload protection, Short Circuit protection,
GMRC October 2026 Page 75 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
shunt trip coil, auxiliary contacts for ON, OFF, TRIP indication etc. as per
drawing and specifications each along with following.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to
measure and display the Electrical quantities like, Current, Voltage,
Active Energy-KWH, Reactive Energy-kVAH, frequency, Maximum
Demand-KVA/KW, Total Hormonic Distortion & power factor etc. with
facility conforming to specifications and latest IEC standards.
ii) 3 Nos. of cast resin current transformers of 200/5 ratio with 15VA
burden and Class 1.0 for measurement
iii) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
iv) 1 set of MCB controlled phase indicating lamps for all three phases.
v) Auxiliary contacts required for necessary interlocking of breakers.
vi) Class-B SPDs shall be provided in all panels and Distribution Boards to
meet all functional requirement as per IEC 61643-12 or latest.
vii) Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
a) Electrolytic high conductivity tinned copper three phase and neutral
busbars rated at >200A as per specification, suitable with stand
symmetrical fault level of 35kA at 415 V. The neutral busbar is to be of
capacity as phases
GMRC October 2026 Page 76 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
a) 3 nos. 160 A, Ics=25 kA, 415 V, TPN MCCB with fixed neutral and with
variable overcurrent and short circuit releases.
a1) 3 nos. Star‐Delta starter of Suitable rating comprising 3 Nos. TP contactor
AC‐3 duty Auto/Manual switch, timer, Start Stop push button, & with
potential free contacts for remote monitoring and control having the
following item for each.
i) 1 No. of AC operated, 4 Digit, independent Digital Ammeter with
selector switch with necessary Circuit MCBs and with suitable size,
Class CTs connections as required for outcoming feeders
ii) 1 set of start stop push buttons with inbuilt ON/OFF indicating lamps.
iii) Auto / Manual selector switch.
iv) Amber healthy trip indicating lamps.
b) 5 no. 20A, Ics= 10 kA, 415 V, TP N MCB with fixed neutral and with
variable overcurrent and short circuit releases.
b1) 2 KW DOL Starter (2 No Sump pumps), Star‐Delta starters of Suitable
rating (2 Nos. Domestic water pumps), Star‐Delta starters of Suitable
rating (1 no jockey pump) with potential free contacts for remote
monitoring and control, having the following items for each:
i) 1 No. of AC operated, 4 Digit, independent Digital Ammeter with
selector switch with necessary Circuit MCBs and with suitable size,
Class CTs connections as required for outcoming feeders
ii) 1 set of start stop push buttons with inbuilt ON/OFF indicating lamps.
iii) Auto / Manual selector switch.
iv) Amber healthy trip indicating lamps
c) 4 no. 20 A, Ics= 25 kA, 415 V, TP N MCB with fixed neutral and with
variable overcurrent and short circuit releases.
c1) 3.5 KW Star-Delta Starter (2 No Borewell pump)with potential free
contacts for remote monitoring and control. having the following item
GMRC October 2026 Page 77 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
i) 1 No. of AC operated, 4 Digit, independent Digital Ammeter with
selector switch with necessary Circuit MCBs and with suitable size,
Class CTs connections as required for outcoming feeders
ii) 1 set of start stop push buttons with inbuilt ON/OFF indicating lamps.
iii) Auto / Manual selector switch.
iv) Amber healthy trip indicating lamps
D Auxiliary relay shall be provided which shall be activated by pressure
switch for remote monitoring.
SITC of Fire & Water Pump Panel (FWP) No. 1375646.55
1.6 Design, Supply, installation, testing commissioning of Escalator Power
Panel (ESPP) complete as per specifications, Drawing and as per
following details:
1.6.1 Escalator Power Panel (ESPP)
a) 2 No. of 250 A, 415V, 35kA, 4P MCCB with changeover switch with E/M
interlocking built in Microprocessor based release unit for Over Current,
Short circuit and earth fault protection with adjustable settings.The
breaking capacity of MCCB shall be Icw=Icu. MCCB shall have in built
compatibility through open protocol like Modbus for SCADA/BMS
connectivity (RS485) along with following accessories.
i) 1 No. of Multi Function Meter with all required to measure and display
the Electrical quantities like, Current, Voltage, Active Energy-KWH,
Reactive Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total
Hormonic Distortion & power factor etc. with facility conforming to
specifications and latest IEC standards. MFM shall have in built
compatibility through open protocol like Modbus for SCADA/BMS
connectivity (RS485) and all required accessories.
vii) 3 Nos. of cast resin current transformers of 250/5 ratio with 15VA
burden and Class 1.0 for measurement
ii) Auxiliary contacts required for necessary interlocking.
GMRC October 2026 Page 78 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
iii) Class-B SPDs shall be provided in all panels and Distribution Boards to
meet all functional requirement as per IEC 61643-12 or latest.
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
Electrolytic high conductivity tinned copper three phase and neutral
busbars rated at >250 A as per specification, suitable to withstand
symmetrical fault level of 35 kA at 415 V with 100% rated neutral busbar.
a) 8 Nos. of 63A, 415V, 25kA, TPN MCCB, with fixed neutral and variable
overcurrent & short circuit releases. Suitably rated AC3 Duty power
contactor of with necessary NO & NC auxiliary contacts as required for
operation through BMS, Auto / manual selector switch, 1 set of MCB
controlled Breaker ON/OFF/TRIP indicating lamps, complete as required
SITC of Escalator Power Panel (ESPP) No. 1250785.2
1.7 Design, Supply, installation, testing commissioning of Commercial
Power Panel (CPP) complete as per specification, Drawing and as per
following details:
1.7.1 Commercial Power Panel (CPP)
2 No. of 160 A, 415V, 25kA, 4P MCCB with changeover switch built in
Microprocessor based release unit for Over Current, Short circuit and
earth fault protection with adjustable settings. The breaking capacity of
MCCB shall be Icw=Icu. MCCB shall have in built compatibility through
GMRC October 2026 Page 79 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
open protocol like Modbus for SCADA/BMS connectivity (RS485) along
with following accessories.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to
measure and display the Electrical quantities like, Current, Voltage,
Active Energy-KWH, Reactive Energy-kVAH, frequency, Maximum
Demand-KVA/KW, Total Hormonic Distortion & power factor etc. with
facility conforming to specifications and latest IEC standards. MFM shall
have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
vii) 3 Nos. of cast resin current transformers of 160/5 ratio with 15VA
burden and Class 1.0 for measurement
ii) Auxiliary contacts required for necessary interlocking.
iii) Class-B SPDs shall be provided in all panels and Distribution Boards to
meet all functional requirement as per IEC 61643-12 or latest.
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
Electrolytic high conductivity tinned copper three phase and neutral
busbars rated at >160 A as per specification, suitable with stand
symmetrical fault level of 25kA at 415 V. The neutral busbar is to be of
same capacity as phases.
a) 1 no. 125 A Ics=15 kA, 415V, 1 No. KWH meter & TPN MCCB C-Curve
each having indication lamps to give ON/OFF/TRIP status.
GMRC October 2026 Page 80 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
b) 2 nos. 63 A Ics=15 kA, 415V, 1 No. KWH meter & TPN MCCB C-Curve
each having indication lamps to give ON/OFF/TRIP status.
C) 2 nos.32A Ics=10 kA, 230V, 1 No. KWH meter & DP MCB C-Curve each
having indication lamps to give ON/OFF/TRIP status.
d) 7 nos. 20A Ics=10 kA, 230V, 1 No. KWH meter & DP MCB C-Curve each
having indication lamps to give ON/OFF/TRIP status.
a) 1 No. in each outgoing, Electronic Energy Meter with RS-485 port for
measuring Current, Voltage Active and reactive Energy, Maximum
Demand & Power factor etc. with TOD facility with suitable size of CT's
for each of the outgoing feeder with locking arrangement.
b) 1 no. in each outgoing, KWH digital energy meter with requisite class CT
SITC of Commercial Power Panel (CPP) No. 1195550.3
1.8 Design, Supply, installation, testing commissioning of A/C Power Panel
(ACPP) complete as per specifications, Drawings and as per following
1.8.1 A/C Power Panel (ACPP) as per specifications, Drawing and as per
following details:
a) 2 No. of 250 A, 415V, 35kA, 4P MCCB with changeover switch built in
Microprocessor based release unit for Over Current, Short circuit and
earth fault protection with adjustable settings. The breaking capacity of
MCCB shall be Icw=Icu. MCCB shall have in built compatibility through
open protocol like Modbus for SCADA/BMS connectivity (RS485) along
with following accessories.
GMRC October 2026 Page 81 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to
measure and display the Electrical quantities like, Current, Voltage,
Active Energy-KWH, Reactive Energy-kVAH, frequency, Maximum
Demand-KVA/KW, Total Hormonic Distortion & power factor etc. with
facility conforming to specifications and latest IEC standards. MFM shall
have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
ii) Auxiliary contacts required for necessary interlocking.
iii) Class-B, SPDs shall be provided in panel as per IEC 61643-12 or latest.
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
vii) 3 Nos. of cast resin current transformers of 250/5 ratio with 15VA
burden and Class 1.0 for measurement
Electrolytic high conductivity tinned copper three phase and neutral
busbars rated at >160 A suitable to with stand symmetrical fault level of
35kA at 415 V. The neutral busbar is to be of same size as phases.
a) 2 no.160A, 415V, Ics=25 kA, 4P MCCB’s(Motor Duty) with indicating
lamps on each phase to give indications.
b) 2 no. 63A, 415V, Ics=25 kA, TPN MCCB’s with indicating lamps (red) on
each phase to give indications.
c) 2 no. 20A, 230V, Ics=10 kA, DP MCB’s with indicating lamps (red) on
each phase to give indications.
SITC of A/C Power Panel (ACPP) No. 717062.85
GMRC October 2026 Page 82 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
1.9 Design, Supply, installation, testing commissioning of Essential lighitng
and power panel for Emergency lighting which is fed from DG set.
complete as per specifications & Drawing with following:
1.9.1 Essential Lighting and Power Panel(ELPP)
A Incomer (from EMDB)
1 No. of 63 A, 415V, 25kA, 4P MCCB with built in Microprocessor based
release unit for Over Current, Short circuit and earth fault protection
with adjustable settings. The breaking capacity of MCCB shall be Icw=Icu.
MCCB shall have in built compatibility through open protocol like
Modbus for SCADA/BMS connectivity (RS485) each along with following
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to
measure and display the Electrical quantities like, Current, Voltage,
Active Energy-KWH, Reactive Energy-kVAH, frequency, Maximum
Demand-KVA/KW, Total Hormonic Distortion & power factor etc. with
facility conforming to specifications and latest IEC standards. MFM shall
have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
ii) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
iii) 1 set of MCB controlled phase indicating lamps for all three phases.
iv) Amber healthy trip indicating lamps
v) 3 Nos. of cast resin current transformers of 100/5 ratio with 15VA
burden and Class 1.0 for measurement
vi) Auxiliary contacts required for necessary interlocking.
vii) Class-B SPDs shall be provided in all panels and Distribution Boards to
meet all functional requirement as per IEC 61643-12 or latest.
viii) Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
GMRC October 2026 Page 83 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Electrolytic high conductivity tinned copper three phase and neutral
busbars rated at >63 A as per specification, suitable to withstand
symmetrical fault level of 25 kA at 415 V with 100% rated neutral busbar.
4 Nos. of 10A/20A , 415V, 10kA, TPN MCB, with fixed neutral and
variable overcurrent, short circuit releases. Suitably rated AC3 Duty
power contactor of with necessary NO & NC auxiliary contacts as
required for operation through BMS, Auto/ manual selector switch, 1 set
of MCB controlled Breaker ON/OFF/TRIP indicating lamps, complete as
required and approved.
SITC of Essential Lighting & Power panel (ELPP) No. 798368.6
1.9 "Design, Detail Engineering, Supply, Erection, Testing and
Commissioning of Reactive Power Compensation and power quality
Improvement along with associated equipments & integration with
existing protection and BMS system as per specification and BOQ
1.9.1 Dynamic Reactive Power Compensation Panel , 33kV/0.415kV IGBT-
based D-STATCOM along with other associated equipments, associated
control and power cabling and earthing arrangement as per approved
SLD , BOQ and specifications. Bidder to quote the SITC price per KVAR
basis. Actual payment shall be made as per total KVAR installed at site
per station. (Approx. KVAR per station required is 200)
SITC of Dynamic Reactive Power Compensation Panel. KVAR 4750
TOTAL OF MV PANELS
2 MV DISTRIBUTION BOARDS
GMRC October 2026 Page 84 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
A Supply, installation, testing & commissioning of front operated, front
access cubicle type, dead front, wall / recess/ surface mounted, totally
enclosed dust and vermin proof ( minimum protection IP 54 ) as per
drawings and specifications. The distribution boards shall be of sheet
steel enclosure with copper bus bars suitable for single or three phase
MCBs. The MCB DB shall fabricated from 2 mm thick CRCA with powder
coated finish suitable for 415 V, 3-phase, 4 wire, 50 Hz system including
suitably rated insulated copper busbars, interconnections, neutral bar
assembly, phase segregating barriers, LED indicating lamps for incoming
and outgoing feeders, knockouts and gland plates for entry of cables and
conduits, all internal wiring using high temperature PVC FRLSH wires,
independant terminals for each phase, neutral & earthing terminals and
including the cost of providing Master key lock on the door and pad
locking facility on door as well as at incomer, bonding to earth etc.
complete as per specification, drawings as required.
a) MCBs shall conform to IEC 60898 (latest) and, with breaking capacity
kA at 415 V AC, current limiting type lower power loss appx 40 - 70% of
the stipulated value and suitable for magnetic releases operating
between 3 to 5 times rated current for normal power distribution
application and 5 to 10 times rated current for motor application duty,
with minimum Electrical endurance of the order of 20000 operation
b) RCBO conforming to IEC 61009-1, IS 12640-2 shall be provided with
100mA sensitivity and electrically connected rated current capacity MCB
for short circuit and over load protection as required
c) All incoming & outgoing feeders of DB shall be terminated on terminal
blocks in the upper compartment including Internal wiring by
d) Class-B SPDs shall be provided in all DB incomers as per IEC 61643-12 or
e) Consider "B" curve for lighting," C" curve for power and "D" curve for
UPS circuit requirement.
GMRC October 2026 Page 85 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
f) Common area DBs and Street Light DBs shall be controlled by
Timer+Contactor.Provision of Auxiliary contactors , push buttons and
indicating lamps for 50% ,75% and 100% selection. Local Remote selector
switch for auto local operation and lighting control from controlled desk
BMS located at SCR.
g) Variable control through BMS to be adopted to save energy for lighting
system for Lighting DB.
2.1 Distribution Boards(Type-1) as per specification and Drawing as per No. 57304.95
following details. LPDB-1, and VD-DB-1,2,3,4
A Distribution board unit for lighting combined with Small Power
consisting of one compartments and upper compartment for terminal
block with respective incoming 4P MCBs having indications for
incoming feeder status as per specifications and as shown on Drawing
a) 1 no. 10/ 32 A, 10kA, 4P, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
c) 3 no. 32A DP RCBO for phase segregation.
d) 12 Nos 10/20 Amp SP MCB with feeder on indication Lamp
2.2 Distribution Boards(Type-2) as per specification and Drawing as per No. 64339.7
following details.( LPDB-2,3,5,6)
A Distribution board unit for lighting combined with Small Power
consisting of one compartments and upper compartment for terminal
block with respective incoming 4P MCBs having indications for
incoming feeder status as per specifications and as shown on Drawing
a) 1 no. 10/ 32 A, 10kA, 4P, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
GMRC October 2026 Page 86 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
OUTGOINGS with feeder.
c) 3 no. 32A DP RCBO for phase segregation.
d) 18 Nos 10A/16A/20A/32A SP MCB with feeder on indication Lamp
2.3 Distribution Boards(Type-3) as per specification and Drawing as per No. 38253.346
following details. ELDB-1,2,3,4,5,6, & UPS-1,2,3,4
A Distribution board unit for lighting with respective incoming DP MCBs
having indications for incoming feeder status as per specifications and
as shown on Drawing and as under:
a) 1 no. 20/40 A, 10kA, DP, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
c) 2 no. 32A DP RCCB .
d) 12 nos. 10A/16A/20A/32A SP MCB with feeder on indication Lamp
2.4 Lighting Distribution Boards (LDB) as per specification and Drawing as No. 63440.525
per following details.(Advertisement)
A Distribution board unit for incoming 4P MCCBs having indications for
incoming feeder status as per specifications and as shown on Drawing
a) 1 no. 63 A, 16kA, 4P, MCCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
a) 9 Nos. of 20A/32A SP MCB arranged in sets of 3 nos. per phase with
feeder on indication Lamp
2.5 AC Distribution Board (ACDB) as per specification & Drawing & as per No. 94395.2015
following details
GMRC October 2026 Page 87 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
A Distribution board unit for incoming 4 pole MCBs having indications
for incoming feeder status as per specifications and as shown on
Drawing and as under:
a) 1 no. 20/63 A, 10kA, 4P, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
Contractor shall provide an earmarked potential free terminals for
SCADA signals as per specification & requirements.
OUTGOINGS with feeder.
c) 3 no. 40A DP RCBO for phase segregation.
d) 24 nos. 16A, DP MCB C-Curve each having indication lamps to give
2.6 Distribution Boards as per specification and Drawing as per following No. 76855.6175
details.(Signage DB)
A Distribution board unit for lighting with respective incoming TPN MCBs
having indications for incoming feeder status as per specifications and
as shown on Drawing and as under:
a) 1 no. 20/40 A, 10kA, 4P, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
c) 3 no. 32A DP RCBO for phase segregation.
d) 10 nos. 10A/16A/20A/32A TPN MCB with feeder on indication Lamp
2.7 Distribution Boards as per specification and Drawing as per following No. 292707.4165
details.(OUTDOOR VRV DB)
A Distribution board unit for lighting with respective incoming Four pole
MCCBs having indications for incoming feeder status as per
specifications and as shown on Drawing and as under:
GMRC October 2026 Page 88 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
a) 1 no. 160 A, 25kA, 4P, MCCB with microprocessor based release having
continously adjustable current setting in the range of 0.4 to 1.0 and 2-10
times of short circuit protection as per Technical specification enclosed.
Shall be suitable for total discrimination.
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
c) 4 nos. 100A TPN MCCB with FEEDER ON indication Lamp
2.8 ENCLOSURE/ISOLATOR BOX
A Design, Supply, Installation, Testing and Commissioning of
Enclosure/Isolator Box fabricated using CRCA Sheet Steel of 2mm. thick
and powder coated (65 Micron Minimum) surface/recess mountable unit
having IP 54 with suitable current rated TPN MCCB inbuilt with 100mA
Earth fault release, spreaders & shrouds at all terminals, gland plate for
incoming & outgoing cables and with suitably rated MCB controlled
multiple LED lamps (Red, Yellow, Blue) for Phase indication and (Red,
Green, Amber) for ON, OFF & Trip status with all required accessories
suitable for 230 VAC operation complete as required and approved.
a) 63A, TPN MCCB inbuilt with 100mA Earth fault release, complete as No. 39092.785
b) 125A, TPN MCCB inbuilt with 100mA Earth fault release, complete as No. 44935.874
TOTAL OF DISTRIBUTION BOARDS
3 MV CABLING & CABLE TRAYS
3.1 Power Cables
GMRC October 2026 Page 89 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
Supply, laying, testing and commissioning of 1100 V grade, XLPE
insulated, PVC extruded, armoured, FRLSH, Conductor cables as per
Technical specification on existing trays/ walls/ columns /indoor
/trenches including the cost of supports with suitable clamps, saddles,
hooks, Anchor fasteners, bolts etc. including proper dressing of cables,
Route markers, providing identification tags, earthing of glands
armouring etc. complete as per specifications and as required. The cost
of cable trays excavation and back filling of trenches will be measured
separate. The cost shall include Heat Shrinkable cable jointing kits for
joining cables wherever joints are unavoidable due to unavailability of
required length of cable in standard drum length.
a) 3.5 core 240 sq. mm Al Conductor RM 2296.796
b) 3.5 core 150 sq. mm Al Conductor RM 1450.289
c) 3.5 core 120 sq. mm Al Conductor RM 1252.9265
d) 3.5 core 70 sq. mm Al Conductor RM 824.106
e) 3.5 core 50 sq. mm Al Conductor RM 621.3855
f) 3.5 core 35 sq. mm Al Conductor RM 479.4175
g) 4 core 16 sq. mm Cu Conductor RM 1235.988
h) 4 core 10 sq. mm Cu Conductor RM 853.708
i) 3 core 16 sq. mm Cu Conductor RM 965.257
j) 3 core 10 sq. mm Cu Conductor RM 682.955
k) 3 core 6 sq. mm Cu Conductor RM 431.281
GMRC October 2026 Page 90 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
l) 3 core 4 sq. mm Cu Conductor RM 315.1815
m) 4 core 2.5 sq. mm Cu Conductor RM 285.171
n) 1 core 16 sq. mm Cu Conductor RM 419.0545
o) 1 core 95 sq. mm Cu Conductor RM 1939.748
p) 3.5 core 95 sq. mm Al Conductor RM 1252.1
3.2 Cable end termination of cables detailed in item 3.1.1 above - including
cost of supplying and fixing of tinned copper Crimping type lugs, double
compression brass glands including earthing, insulation tape etc. Gland
should be earthed individually with gland ring copper strip and copper
wire, complete as per specifications and as required.
a) 3.5 core 240 sq. mm Al Conductor No. 2545.639
b) 3.5 core 150 sq. mm Al Conductor No. 2003.835
c) 3.5 core 120 sq. mm Al Conductor No. 1633.8385
d) 3.5 core 70 sq. mm Al Conductor No. 1221.719
e) 3.5 core 50 sq. mm Al Conductor No. 1045.5225
f) 3.5 core 35 sq. mm Al Conductor No. 816.2305
g) 4 core 16 sq. mm Cu Conductor No. 737.276
GMRC October 2026 Page 91 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
h) 4 core 10 sq. mm Cu Conductor No. 559.816
l) 3 core 16 sq. mm Cu Conductor No. 669.579
j) 3 core 10 sq. mm Cu Conductor No. 547.865
k) 3 core 6 sq. mm Cu Conductor No. 461.472
l) 3 core 4 sq. mm Cu Conductor No. 379.981
m) 4 core 2.5 sq. mm Cu Conductor No. 322.3825
n) 1 core 16 sq. mm Cu Conductor No. 373.92
o) 1 core 95 sq. mm Cu Conductor No. 613.89
p) 12 C x 1.5 sq. mm Cu Conductor No. 559.4075
q) 3.5 core 95 sq. mm Al Conductor No. 1221.7
3.3 Supply, laying, testing and commissioning of Control cables of following
size cables as per List of approved makes including the cost of jointing &
termination with required accessories.
a) 2 C x 1.5 sq. mm Cu Conductor RM 145.863
b) 12 C x 1.5 sq. mm Cu Conductor RM 472.834
c) 19 C x 1.5 sq. mm Cu Conductor RM 687.819
3.4 Cable Trays
GMRC October 2026 Page 92 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
3.4.1 Supply, installation of factory fabricated, perforated, hot dip galvanized
(Minimum Thickness shall be 85 microns), double bended cable trays
from 2 mm thick sheet steel continuously connected including inward,
outward, horizontal & vertical bends, reducers, tees, flexible earth
connector and other accessories. All the cable tray accessories shall be
factory pre-fabricated, until otherwise specific approval is obtained to
fabricate at site.
a) 300 mm wide x 50 mm depth RM 1231.7985
b) 150 mm wide x 50mm depth RM 849.3855
c) 100 mm wide x 50mm depth RM 713.735
d) 50 mm wide x 50mm depth RM 560.766
3.4.2 Supply, installation of factory fabricated Ladder type hot dip (welded)
galvanized cable trays (Minimum Thickness shall be 85 microns) from
mm thick sheet steel continuously connected including inward, outward,
horizontal & vertical bends, reducers, tees, flexible earth connector and
other accessories. All the cable tray accessories shall be factory pre-
fabricated, until otherwise specific approval is obtained to fabricate at
site. Runner size shall be 75mm x 20mm x 2.5 mm and Rung size 30mm x
20mm x 2.5mm with centre to centre distance of 250mm, as required.
a) 600 mm wide X 75 mm height RM 1428.154
b) 300 mm wide X 75 mm height RM 1112.07
3.4.3 Supply & erection of support brackets made out of Hot dip galvanised
factory fabricated cantilever support /channels in conformance to IEC
61537 to the required size and shape.
GMRC October 2026 Page 93 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
a) Supply and installation as required for Factory Fabricated Hot dip Kgs 143.4405
galvanized (65 micron thick) cantilever bracket support / fabricated
member for fixing to wall/ ceiling/beam and for use with cable tray
systems or cable ladder system in terms of IEC 61537 or Pendent with
Mid support Bracket with high level of workmanship and design
approprietly sized as required in terms of the IEC 61537 for uniform
distibution and design appropiately sized as required in terms of the IEC
61537 for uniform distribution of Load.
Note: Trays shall be supported adequately using galvanized structural
members. This support should be capable of withstanding the weight of
the equivalent weight of 3m length of cables laid over it. Rigid ISA /
ISMC / ISMB / flats/ Vertical Rods support shall be provided at every 1m
length and also at diversions, crossings, bends and multi layered
locations.At turns the support has to be double and at both ends of the
3.5 Supply and fixing of Raceway junction box made out of 2.0mm thick
sheet steel with hot dip galvanizing finishing including polished 3/5mm
Thick SS 304 top cover, fixed with SS Counter Sunk screw of sufficient
a) 250 x 250 x 75 deep box with polished 5mm SS sheet top cover No. 1354.8045
b) 150 x 150 x 75 deep box with polished 3mm SS sheet top cover No. 887.908
c) 100 x 100 x 75 deep box with polished 3mm SS sheet top cover No. 640.034
3.6 Supply and laying of raceway made of 2mm thick GI sheet with top cover
race way trunking of different size along with (covered in the followed
item) as required. Note: The rate is inclusive of all fixing arrangement,
steel parts, welding work etc. as required Contractor shall get the
drawing / design of raceway approved from the Engineer before bulk
GMRC October 2026 Page 94 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
a) 200 x 50 x 2mm thick RM 1474.533
b) 150 x 50 x 2mm thick RM 1216.437
c) 100 x 50 x 2mm thick RM 958.341
TOTAL OF MV CABLE, CABLE TRAYS and RACEWAYS
4 WIRING SYSTEM
4.1 Supply & laying of conduit and wiring for the following light / Ceiling
Fan/ Signage with 3 x 2.5 sq. mm, 1100 Volt grade PVC insulated FRLSH
copper condutor wires in heavy gauge 25mm dia GI conduit (16 SWG)
surface run with GI saddles, or concealed or in GI raceway including
chases and complete with GI junction boxes, pull boxes, inspection
boxes,bends & other accessories etc. including insulated Protective Earth
(PE) Conductor and earthing of switch boxes excluding the cost of
switches/sockets and switch boxes.as specified and as under:
First point controlled by one Swichboard (6A switch)/10A MCB No. 9226.495
4.2 Secondary or looping points wiring as specified in 4.1 above using 3x2.5 No. 5490.772
copper (P+N+PE) wires in 25 dia GI conduit (16 SWG) for lights, fans,
socket outletsincluding providing terminal block, ceiling rose & other
accessories etc as required (exlcuding the cost of switches, sockets &
switch boxes) as per specifications and drawings as required
4.3 Supply & laying of wiring for the following light point with 3 core x
sq. mm, 1100 Volt grade PVC insulated FRLSH copper condutor flexible
cabe in existing raceway or existing heavy gauge GI conduit (16 SWG)
surface run with GI saddles, or concealed or in GI raceway including
chases and complete with GI junction boxes, pull boxes, inspection
boxes,bends & other accessories etc. including insulated Protective Earth
(PE) Conductor and earthing excluding the cost of MCB as specified and
GMRC October 2026 Page 95 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
One point controlled by 10A MCB. No. 4138.276
4.4 Secondary or looping points wiring as specified in 4.3 above using 3 core No. 1785.9145
x 2.5 sq. mm insulated copper (P+N+PE) flexible cable in existing GI
raceway for lights on Platform outlets including providing terminal block,
ceiling rose & other accessories etc as required (exlcuding the cost of
switches, sockets & switch boxes) as per specifications and drawings as
4.5 Supply & laying of conduit and wiring for the following 16A / 32A socket
outlet point with 3 x 6 sq. mm, 1100 Volt grade PVC insulated FRLSH
copper condutor wires in heavy gauge GI conduit (16 SWG) surface run
with GI saddles.
a) One no. 16A /32A socket outlet point controlled by one 16A switch / No. 12710.886
4.6 Secondary or looping 16A socket outlet points wiring as specified in 4.5 No. 4775.194
above using 3 x 4 sq. mm copper (P+N+PE) wires in 25 dia GI conduit (16
SWG) for socket outletsincluding providing terminal block, ceiling rose &
other accessories etc as required (exlcuding the cost of switches, sockets
& switch boxes) as per specifications and drawings as required
With regard to Item Nos.4.1 to 4.6, for further clarifications, the sample
measurement system to be followed is given below :-
a) In case of 10 nos. light fixtures looped together and controlled directly
from one no. MCB in DB, quantity to be paid shall be 1 No. as per Item
No. 4.1 or 4.3 as applicable and quantity to be paid shall be 9 Nos. as per
item no. 4.2 or 4.4 as applicable.
b) In case of 5 nos. light fixtures looped together and controlled from
switch located in a room, quantity to be paid shall be 1 no. as per Item
No.4.1 and quantity to be paid shall be 4 Nos. as per item no.4.2.
Conduit & wire laid from MCB in DB to first light point via switch point
shall not be paid separately and is included in the rate in item no. 4.1.
Same shall be the case for item nos. 4.5 & 4.6 as applicable.
GMRC October 2026 Page 96 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
4.7 Supply,installation & testing of following modular grid plate mounted
switch/es and socket/s etc. on a suitable size mild steel electrogalvanised
switch boxes complete in single or combination on prorata basis
complete with the connections, earthing and testing as per specifications
and as required:(Note the grid plate and MS BOX shall be selected
suitably as per the requirement to fix the switches and sockets.
a) 1 no. 6A modular switch Each 289.7595
b) 1 no. 6A switch & 1 # 6A socket Each 475.703
c) 1 no. 6A socket Each 344.0805
d) 6/16 Amp Universal socket with 16 amp modular switch Each 593.2465
e) 32A 3 pin industrial socket outlet with 32 A DP RCCB 30mA with MCB Each 7838.8775
shall be of standard powder coated MS steel IP-55 enclosure, separately
4.8 Supply and installation of GI conduiting complete with GI junction and
pull boxes, GI fish wires as specified and as shown below. After making
the recessed, the wall etc shall be repaired and brought to its original
finish. No extra payment shall be made for this finishing work.
a) 25 mm dia 1.6mm thick M 265.468
TOTAL OF : WIRING SYSTEM
5 LIGHTING SYSTEM
5 Supply, installation, testing & commissioning of LED light fittings
including all accessories e.g. Driver, HPF condensers (surge protector),
surface/recess mounting arrangement etc. including necessary supports,
accessories and hardware as per specifications & as required at site and
GMRC October 2026 Page 97 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
5.1 Luminaries minimum specifications and requirements
a) Luminaries should operate at +/- 6% voltage fluctuation for continuous
use to comply to IEC.
b) All the components including the internal wiring of the luminaries to be
used shall be manufactured of material, which are of FR type. All
luminaries shall be manufactured to relevant sections of IEC 60598 or
other approved international standards and the type tests for all
luminaries shall be provided.
c) All internal wiring within the lighting fixtures shall be heat-resisting
Note: Lamp should have free replacement for one year from the date of
Installation. The Date of installation shall be from the date of handing
over the work to GMRCL.
5.1.1 Supply, Installation, Testing & Commissioning of Trunking LED ,made up No. 5108.9955
of extruded Aluminium body and acrylic cover. Luminaries should be
with minimum system efficacy of 120 Lumen/Watt and minimum system
lumen output of 3800, maintained at 70% at the end of 50,000 burning
hours. The luminaries should have CRI>80 and CCT of >5300 K.
Luminaries should withstand THD less than 10% and should have power
factor > 0.95 . Driver efficiency should be 85%. The luminaries should be
IP 54 protected. Luminaries should comply with all the required IEC
standards 32 W and should operate in a voltage range of 220 to
volts AC. Similar To Philips Optimus LED Trunking LL199X1XDLED40-
6500 PSE OD WH or approved equivalent Make. ( General purpose)
GMRC October 2026 Page 98 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
5.1.2 Supply, Installation, Testing & Commissioning of LED ,made up of No. 1485.23
extruded Aluminium body and acrylic cover. Luminaries should be with
minimum system efficacy of 120 Lumen/Watt and minimum system
lumen output of 4000, maintained at 70% at the end of 50000 burning
hours. The luminaries should have CRI>80 and CCT of >5300 K.
Luminaries should withstand THD less than 10% and should have power
factor > 0.95 . Driver efficiency should be 85%. The luminaries should be
IP 54 protected. Luminaries should comply with all the required IEC
standards 34 W and should operate in a voltage range of 220 to
volts AC. Similar To Philips BN308C LED40S-6500 L120 PSD WH or
approved equivalent Make. (B.O.H. AREA)
5.1.3 Supply, Installation, Testing & Commissioning of LED ,made up of No. 3018.3685
extruded Aluminium body and acrylic cover. Luminaries should be with
minimum system efficacy of 120 Lumen/Watt and minimum system
lumen output of 4000. The luminaries should have CCT of 4000K.
Luminaries should withstand THD less than 10% and should have power
factor > 0.85 . Driver efficiency should be 85%. The luminaries should be
IP 65 protected. Luminaries should comply with all the required IEC
standards 34 W and should operate in a voltage range of 220 to
volts AC. Similar To Philips WT201C LED44S-6500 PSU L120 or
approved equivalent Make. (FOR SUSPENDED LIGHT)
5.1.4 Supply, Installation, Testing & Commissioning of LED ,made up of No. 10265.8995
extruded Aluminium body and acrylic cover. Luminaries should be with
minimum system efficacy of 120 Lumen/Watt and minimum system
lumen output of 23500, maintained at 70% at the end of 50,000 burning
hours. The luminaries should have CRI>80 and CCT of 6500K. Luminaries
should withstand THD less than 10% and should have power factor >
0.95 . The luminaries should be IP 66 protected. Luminaries should
comply with all the required IEC standards 154 W and should operate in
a voltage range of 220 to 240 volts AC.BVP 483 LED 185 CW SMB PSU GR
(Flood Light) for (Double height area).
GMRC October 2026 Page 99 of
GMRC/CONS/STNS+VDCT-1/2026 BOQ
5.1.5 Supply, Installation, Testing & Commissioning of surface/Conduit LED No. 2739.61
Batten Luminaries, made up of CRCA sheet with glossy PC diffuser.
Luminaries should be with minimum system efficacy of 125Lumen/Watt
and minimum system lumen output of 4200 maintained at 70% at the
end of 40,000 burning hours. The luminaries should have CRI>80 and
CCT of 6500K. Luminaries should withstand THD less than 10% and
should have power factor > 0.95 . Driver efficiency should be 85% .
Luminaries should comply with all the required IEC standards 32 W and
should operate in a voltage range of 140 to 270 volts AC. Similar To
Philips RC380B LED36S-6500 G5 L60W60 PSU OD OR approved
equivalent Make. (False Ceiling Rooms)
5.1.6 Supply, Installation, Testing & Commissioning of recessed mounted LED No. 1276.1635
Downlighter, made of pressure die-cast Aluminium body with high
quality diffuser. Luminaries should be with minimum system efficacy of
110Lumen/Watt and minimum system lumen output of 1500 maintained
at 70% at the end of 50,000 burning hours. The luminaries should have
CRI>80 and CCT of 4000K. Luminaries should withstand THD less than
10% and should have power factor > 0.90 . Driver efficiency should be
85%. Luminaries should comply with all the required IEC standards
w and should operate in a voltage range of 220 to 240 volts AC. Similar
To Philips Green Perform LED Downlighter DN 296 B LED 15SPSU WH or
approved equivalent Make. (For Toilets)
5.1.7 Supply, Installation, Testing & Commissioning of LED ,made up of No. 11102.156
extruded Aluminium body and acrylic cover. Luminaries should be with
minimum system efficacy of 125 Lumen/Watt and minimum system
lumen output of 23500, maintained at 70% at the end of 50,000 burning
hours. The luminaries should have CRI>70 and CCT of 5700K. Luminaries
should withstand THD less than 10% and should have power factor >
0.95 . Driver efficiency should be 85%. The luminaries should be IP
protected and IK 08. Luminaries should comply with all the required IEC
standards 195 W and should operate in a voltage range of 220 to
volts AC.BVP 483 LED 235 CW SWB PSU GR (Flood Light) for ( OUTSIDE
GMRC October 2026 Page 100 of
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. NIT.pdf
2. ITT.pdf
3. FoT.pdf
4. GCC.pdf
5. SCC.pdf
6. SHE.pdf
7. Employers Requirement_1.pdf
7. Employers Requirement_2.pdf
7. Employers Requirement_3.pdf
7. Employers Requirement_4.pdf
7. Employers Requirement_5.pdf
8.1 TS_Civil_1.pdf
8.1 TS_Civil_2.pdf
8.2 TS - EM_1.pdf
8.2 TS - EM_2.pdf
8.2 TS - EM_3.pdf
9. Tender drawing.pdf
10. BOQ.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .