Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.8 LAdmitted-Finance | ₹97.8 L | L1 | Admitted-Finance |
| 2 | L2₹99.1 LAdmitted-Finance 0 H NO 11 0 OLD POLICE STATION NANDNI COLONY TVM SCHOOL HARIPURA ALWAR RAJASTHAN 301022 | ALWAR | RAJASTHAN | 301022 | ₹99.1 L | L2 | Admitted-Finance |
| 3 | L3₹99.9 LAdmitted-Finance 1217 SHIVAM VIHAR GANESHPUR ROORKEE HARIDWAR | ₹99.9 L | L3 | Admitted-Finance |
| 4 | L4₹1.0 CrAdmitted-Finance | ₹1.0 Cr | L4 | Admitted-Finance |
| 5 | L5₹1.1 CrAdmitted-Finance 09 DADU BAGH MARKET KANKHAL HARIDWAR JV M S REVAN SINGH BISHT VILLAGE BHANAULI POST HATT GAON TEHRI GARHWAL | HARIDWAR | HARIDWAR | UTTARAKHAND | ₹1.1 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Girish Kumar L1 | goyal and sons L5 | Shri Balaji Enterprises L2 | Manik Goyal L4 | M/s Balaji Construction L6 | M/s Lakshay Construction L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil | 513.22 | Cum. | 146 ₹74,930.12 | 125 ₹64,152.50 | 126 ₹64,665.72 | 50 ₹25,661 | 40 ₹20,528.80 | 95 ₹48,755.90 |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 359.25 | Cum. | 150 ₹53,887.50 | 138 ₹49,576.50 | 138 ₹49,576.50 | 50 ₹17,962.50 | 62 ₹22,273.50 | 110 ₹39,517.50 |
| 3.00 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration | 337.65 | Sqm | 100 ₹33,765 | 218 ₹73,607.70 | 10 ₹3,376.50 | 80 ₹27,012 | 150 ₹50,647.50 | 190 ₹64,153.50 |
| 4.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | 57.06 | Cum. | 4,000 ₹2.3 L | 4,778 ₹2.7 L | 4,800 ₹2.7 L | 4,500 ₹2.6 L | 4,500 ₹2.6 L | 4,000 ₹2.3 L |
| 5.00 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. | 26.54 | Cum. | 100 ₹2,654 | 1,490 ₹39,544.60 | 200 ₹5,308 | 1,000 ₹26,540 | 1,350 ₹35,829 | 1,435 ₹38,084.90 |
| 6.00 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). | 39.37 | Sqm. | 262 ₹10,314.94 | 289 ₹11,377.93 | 338 ₹13,307.06 | 338 ₹13,307.06 | 290 ₹11,417.30 | 277 ₹10,905.49 |
| 7.00 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum | 109.16 | Cum. | 6,074 ₹6.6 L | 6,666 ₹7.3 L | 6,675 ₹7.3 L | 6,200 ₹6.8 L | 6,650 ₹7.3 L | 7,000 ₹7.6 L |
| 8.00 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum | 198.02 | Cum. | 6,300 ₹12.5 L | 6,916 ₹13.7 L | 6,925 ₹13.7 L | 6,500 ₹12.9 L | 7,425 ₹14.7 L | 7,000 ₹13.9 L |
| 9.00 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars | 36,170.06 | Kg | 67 ₹24.2 L | 75.65 ₹27.4 L | 80 ₹28.9 L | 76 ₹27.5 L | 83 ₹30.0 L | 80 ₹28.9 L |
| 10.00 | Centring and shuttering including strutting,ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete | 158.4 | Sqm. | 250 ₹39,600 | 275 ₹43,560 | 320 ₹50,688 | 300 ₹47,520 | 250 ₹39,600 | 250 ₹39,600 |
Tender Value
₹1.3 Cr
EMD Value
₹2.5 L
Closing Date
14 Jan 2026, 5:00 pmClosed
General Manager
Office of Chief General Manager, Construction Wing, Uttarakhand Peyjal Nigam, Kamla Nagar(Opp. ONGC Hospital), Dehradun
CONSTRUCTION OF SCIENCE AND ART BLOCK AT GOVT. HIGH SCHOOL, BANIYAWALA, DEHRADUN, UTTARAKHAND
2025_MDPEY_90354_1
5257/Nivida(Garh)D.Dun/97 Dt 24/12/2025
Open Tender
Civil Works
365 days
BANIYAWALA
Please refer tender doucment
3 documents required · 3 mandatory
₹5,900
PM, Const.Unit, UKPJN, Dehradun
₹2.5 L
Dehradun
7 Feb 2026
26 Dec 2025
15 Jan 2026
26 Dec 2025
14 Jan 2026
5 Jan 2026
27 Dec 2025 - 2 Jan 2026
3 Jan 2026
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars
Centring and shuttering including strutting,ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centring and shuttering including strutting,ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access
Centring and shuttering including strutting,ropping etc. and removal of form for Shelves
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
15 mm cement plaster on the rough side of wall of mix : 1:6 (1 cement: 6 fine sand)
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, includingapplying priming coat of approved steel primer. M.S. tube
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). each
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. : Powder coated minimum thickness 50 micron aluminium tubular handle bar
Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :250x10 mm
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and laying APP(Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15 mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.32 mm dia nominal bore
Providing and fixing CPVC UNION-SOC, FITTINGS HSN CODE: 39174000 15 mm dia nominal bore
Providing and fixing CPVC UNION-SOC, FITTINGS HSN CODE: 39174000 20 mm dia nominal bore
Providing and fixing CPVC UNION-SOC, FITTINGS HSN CODE: 39174000 25 mm dia nominal bore
Providing and fixing CPVC UNION-SOC, FITTINGS HSN CODE: 39174000 32 mm dia nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Supply and fixing of kIRLOSKER Centrifugal Self Priming Mono block Pump (KIRLOSKAR & SP2HM) Pump Type Self Priming Mono block Pump, Size (Dia) of solids in liquid to be handled 15.5 millimeter, Suction Pipe size (Nominal) 50 millimeter, Delivery pipe size (Nominal) 50 millimeter, Speed in RPM 2900 Impeller Material Cast Iron, Motor Type AC Motor ISI Marked 3 Phase , 415 V ± 10%, 50Hz±3%Hz complete in all aspects as per direction of Engineer In-charge
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 225 mm
Providing and fixing soil , waste and vent pipes: Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 75 mm dia
Providind and fixing M.S.holder bat clamps of approved design to sand cast iron/cast iron (squn) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1cement :2coarse sand :4graded stone aggregate 20mm nominal size ) including cost of cutting holes and making good the walls etc: for 75 mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 75 mm diameter pipe
Providing and fixing 100 mm sand cast iron S&S plain bend of required degree. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 75 mm diameter pipe
Providing and fixing heel rest sanitary bend. 75 mm diameter pipe
Providing and fixing double equal plain junction of required degree. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 75x75x75x75x75 mm
Providing and fixing single equal plain junction of required degree : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 75x75x75 mm
Providing and fixing single unequal plain junction of required degree : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 100x100x75 mm
Providing and fixing single unequal plain invert branch of required degree : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 100x100x75 mm
Providing and fixing Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 65 mm offsets With 75 mm dia pipe
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989
Providing and fixing C.P. brass 32mm size bottle trap of approved quality & make and as per the direction of engineer-ing-charge.
Providing and fixing collar : 75 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipe:- 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories :-coupler 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories :-Bend 87.5° 110 mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes :- 110 mm
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring for light/power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required. 25mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required
Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required. 63 amps
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 50 mm depth X 2.0 mm thickness
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required..
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below Stilt as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply and fixing of 1200MM SWEEP Ceiling Fan with Regulator Model : Double Ball Bearing, Sweep : 1200mm, Body : Cast Aluminium (Both top and bottom) Colour : White, Accessories : Complete Body with Blades, Downrod, Canopies (2 numbers), Fixing Clamps & Rubber Bush. Regulator : Resistance / Switch type Electronic Input supply : Single phase 230VAC +/-10% ; 50Hz +/-5%, Make : Usha / Orient / Khaitan / Crompton Greaves/Havells / Bajaj / Almonard / Calcutta Fans complete in all aspects as per direction of Engineer In-charge 1200 mm sweep
Supply and fixing of 18 Watt/1800 lumen 6500 K LED Tubelight, Type of Tube Light Cap G-13 Bi-pin, Ingress Protection in IP IP 20, Lamp Shell material Polycarbonate, Length of tube light 1220mm, LED lamp efficacy (Lm/W) 100, Colour Rendering Inde (CRI) > / = 80, Total Harmonics (%) < / = 15%, Beam Angle (Degree) > / = 120 degree, Operating Voltage range (Volt) 100-300, Driver Efficiency (%) more than 85%, Surge Voltage withstand (KV) 2.5 KV, LED Chip Efficacy (Lm/W) 130, Rated Voltage for Performance and life (Volt) 220-240, Lumen Maintenance at 25 deg;C after 6000 hrs (%) 80%, LED Chip Wattage (Individual) (Watt) 0,25, Power Factor > / = 0.9, complete in all aspects as per direction of Engineer In-charge
Supply and fixing of NAMASTE LED LIGHTS 18 Watt/1800 lumen 6500 K LED Tubelight, Type of Tube Light Cap T-5, Ingress Protection in IP IP 20, Lamp Shell material Polycarbonate, Light Source SMD LED Chip, LED Make Bridgelux, Length of tube light 1180 mm, LED lamp efficacy (Lm/W) 100, Colour Rendering Inde (CRI) > / = 80, Total Harmonics (%) < / = 15%, Beam Angle (Degree) > / = 120 degree, Operating Voltage range (Volt) 100-300, Driver Efficiency (%) more than 85%, Surge Voltage withstand (KV) 2.5 KV, LED Chip Efficacy (Lm/W) 130, Rated Voltage for Performance and life (Volt) 220-240, Lumen Maintenance at 25 deg;C after 6000 hrs (%) 80%, LED Chip Wattage (Individual) (Watt) 0,25, Power Factor > / = 0.9, complete in all aspects as per direction of Engineer In-charge
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.22 MB
Tendoc_Baniyawala.pdf
Tender Documents • 3.29 MB
BOQ_107061.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid