Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹29.2 L+₹25,765 (0.89%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹30.9 L+₹2.0 L (6.81%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
2 May 2024, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
REPAIR MAINTENANCE OF CHLORONOME PLANTS SOLAR WATER HEATING SYSTEM VALVE PITS DG SET OF WATER SUPPLY INSTALLATIONS AND MISC ITEMS AT SECTOR C UNDER GE UTILITY AMBALA CANTT
2024_MES_648573_1
CA NO GE U AMB T 40 OF 2024-25
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹96,000
28 May 2024
30 Mar 2024
4 May 2024
30 Mar 2024
2 May 2024
18 Apr 2024
30 Mar 2024 - 6 Apr 2024
Amount
Periodical Maintenance of DG set such as replacement of Engine Oil, Oil filter, Air filter and diesel filter, cleaning of air filters, replacement of water hose, cleaning of filter housing etc of Make: Kirloskar diesel engine generating sets including replacement of rusted and defective nuts, bolts, and washers etc as required at site of following capacity,one in a quarterly duration complete all as specified & directed. Note: (i) Spares (Oil and filters) required for maintenance of DG set will be measured and paid seperately. (ii) Periodical maintenance/ servicing of DG Set shall to be carried out at every 250 hrs to maintain the serviceability of DG Set.
500 KVA DG Set
400 KVA DG Set
125 KVA DG Set
SUPPLY & FIX SPARE PARTS FOR 500 KVA KIRLOSKAR DG SET
Fuel filter
Lub Oil filter
Air filter
Fan Belt
Fuel pipe kit
Coolant
Engine oil
SUPPLY & FIX SPARE PARTS FOR 400 KVA KIRLOSKAR DG SET
Diesel filter
Lub Oil filter
Supply and fix Air filter
Supply and fix only Fan belt
Diesel Pipe kit
Hose pipe kit
Coolant
Engine oil
SUPPLY & FIX SPARE PARTS FOR 125 KVA KIRLOSKAR /Cummins DG SET
Diesel filter
Lub Oil filter
Air filter
Fan belt
Diesel Pipe kit
Coolant
Engine oil
Material and labour for caliberation of fuel injection pump by authorised dealer with replacement of worn out parts, testing and commissioning complete including alignment, plunger, packing kit, spring delivery valve etc. required to make the pump serviceable of DG set of capacity 500 KVA complete all as specified and directed. (The item rate includes transportation of pump from site to dealers workshop and back).
Material and labour for caliberation of fuel injection pump by authorised dealer with replacement of worn out parts, testing and commissioning complete including alignment, plunger, packing kit, spring delivery valve etc. required to make the pump serviceable of DG set of capacity 125 KVA complete all as specified and directed. (The item rate includes transportation of pump from site to dealers workshop and back).
Material and labour for removing the radiator after disconnecting from engine, opening the parts of radiator for servicing and repairing/ replacement of unserviceable minor parts including brazing/ welding complete of DG set of capacity 500 KVA complete all as specified and directed. (The item rate includes transportation of radiator from site to workshop and back and refixing the radiator in position).
Material and labour for removing the radiator after disconnecting from engine, opening the parts of radiator for servicing and repairing/ replacement of unserviceable minor parts including brazing/ welding complete of DG set of capacity 125 KVA complete all as specified and directed. (The item rate includes transportation of radiator from site to workshop and back and refixing the radiator in position).
Supply and fixing in replacement of Turbo Charger Assy of DG set of capacity 500 KVA complete all as specified and directed.
Supply and fixing in replacement of Turbo Charger Assy of DG set of capacity 125 KVA complete all as specified and directed.
Material and labour for repair of self starter of 500 KVA DG set including taking out burnt out winding, rewinding the same and replacment of burn out parts carbon brush, brushes etc complete all as specified and directed. Note: The items rates incl transpotation of self startor from site /store to workshop and back to site /store
All as per ser. item no 11 here in before but for 400 KVA complete all as specified and directed.
All as per ser. item no 11 here in before but for 125 KVA complete all as specified and directed.
Supply and fixing of Water Pump Assy of DG set of capacity 500 KVA to 400 KVA including taking down existing complete all as specified and directed.
Supply and fix flywheel ring gear for 500 KVA to 400 KVA DG set including taking down existing complete all as specified and directed.
Supply and fix in repair of lead acid power pack unit (battery bank) 12 volts 180AH capacity with charger maintenace free including taking down existing battery pack unit complete all as specified and directed. Make: Exide/Amron or as approved by GE.
Supply and fix as in replacement electric heating element of 3 KW suitable for thermostat housing of Solar water heater of 200 litre capacity.complete all as specified and directed.
Supply and fix as in replacement thermostat switch for Solar water heater of 100 LPD to 2000 LPD capacity.complete all as specified and directed.
Opening the collector and providing chemicals for descaling the system with proper equipment complete and refixing the same for 100/200 LPD complete all as specified and directed. Note: Here one job is considered as one complete solar water heating system and quoted rate must include the same thing.
All as per item No. 19 here in before but solar water heating system of 300/400/500 LPD capacity complete all as specified and directed.
All as per item No. 19 here in before but solar water heating system of 800/1000 LPD capacity complete all as specified and directed.
Material and labour for brazing/welding to hot water storage tank of solar water heater of 100 LPD to 500 LPD litre capacity made of stainless steel (IA SI-304) 1.6 mm thick.
All as per item No. 22 here in before but solar water heating system of 800/1000/2000 LPD capacity.
Supply and fix in Replacement of PVC hose pipe for Solar water heating system of 100 to 2000 LPD capacity including clamps , washers, bolts etc where-ever required.
Supply and fix aluminum sheet 1mm thick for repairing of Hot water tank of any capacity Solar water heater system including nuts, bolts etc. all as specified and directed.
Supply and fix as in replacement GI nipple 20mm bore 8" long for Hot water tank of solar water heating system complete all as specified and directed.
Supply and fix as in replacement anchor bolt 12mm x 100mm long complete all as specified and directed
Material and labour for solar flat plate collector with all necessary accessories complete all as specified and directed.
Material and labour for solar heating stainless steel tank of size 100/200/300 LPD capacity with heat exchanger including necessary connections ,fittings complete all as specified and directed.
Material and labour for solar heating stainless steel tank of size 500/800/1000 LPD capacity with heat exchanger including necessary connections ,fittings complete all as specified and directed.
Material and labour for Glass wool /Rock wool for insulation of solar water heater complete all as specified and directed.
Material and labour for Lagging to pipes used in internal water supply or plumbing all round with,25min thick bonded mineralwool preformed ‘SNAP ON’pipe sections of density 144 Kg/cum conforming to IS aluminium cladding for insulation of solar water heater complete all as specified and directed.
Material and labour for Mild steel framed work for SWH stand, (made out of rolled section), cut to shape including bending and welding as necessary with complete accessories required for fixing of solar water heater hold fast conforming to Fe-310-O including tarring to the surface come in contact with the concrete or masonry work complete all as specified and directed.
Supply and fix in replacement 20 Watt LED fitting surface and wall mounted, extruded Alumininum housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver including flexible wire for electrical connection and testing complete all as specified and directed.
Material and labour for MCCB 4P, 415 Volts, 500 Amp, 25 KA complete all as specified and directed.
Material and labour for MCCB 4P, 415 Volts, 320 Amp, 25 KA complete all as specified and directed.
Material and labour for MCCB 4P, 415 Volts, 250 Amp, 25 KA complete all as specified and directed.
Material and labour for MCCB 4P, 415 Volts, 200 Amp, 25 KA complete all as specified and directed.
Material and labour for MCCB 4P, 415 Volts, 160/ 125 Amp, 25 KA complete all as specified and directed.
Supply & fixing in replacement Neopin gasket complete all as specified and directed.
Material and labour in replacement of make up steel tank of cap 5 ltr suitable for existing system complete all as specified and directed.
Material and labour for dismantelling and opening of Gravity feed type chloronome plant for repairing and making the same functional including installation, testing & commisioning complete all as specified and directed. Note: Spare parts shall be measured and paid separately.
Supply and fix Teflon pipe 9.5mm dia with PVC nuts and nipple 5 mtr length complete all as specified and directed.
Supply and fix Primary filter with moisture nut and tube complete all as specified and directed.
Supply and fix Chlorine secondary filter with glass N.R.V complete all as specified and directed.
Supply and fix Glass Moisture trap complete all as specified and directed.
Supply and fix Rubber Washer for moisture trap tube complete all as specified and directed.
Supply and fix water Chlorine mixing chamber complete all as specified and directed.
Supply and fix PVC solutioniser as per existing complete all as specified and directed.
Supply and fix PVC Fitting Tee complete all as specified and directed.
Supply and fix water Bend complete all as specified and directed.
Supply and fix Glass bend with glass N.R.V complete all as specified and directed.
Supply and fix Solutioniser out let complete all as specified and directed.
Supply only synthetic insulation mat of size 2mtrx1mtrx25 mm complete all as specified and directed.
Supply only PH and chlorine testing kit suitable for testing with O-Tolidine solution for regular test including solution, in the packing 500 ml complete all as specified and directed. Make: NICE or equivalent as approved by GE.
Supply and fix in replacement of Ammeter 96x96 sqmm, 0-200 Amp digital type with CT complete set all as specified and directed.
Supply and fix in replacement of volmeter 96x96 sqmm, 0-500 Amp digital type with CT complete all as specified and directed.
Supply and fix in replacement ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 800 Amps complete all as specified and directed. Make havells or equivalent as per existing.
All as per item No 58 here in before but of 630 Amps.
All as per item No 58 here in before but of 400 Amps.
All as per item No 58 here in before but of 320 Amps.
All as per item No 58 here in before but of 200 Amps.
Supply and fix in replacment defective aluminium bus bar (set of four) of rating upto 400 Amps including nut , bolts, washers, etc complete all as specified and directed.
Supply and fix in replacement defective phase indicators (set of three red, green & yellow) of ratings 240 volts, single phase complete all as specified and directed.
Material and labour for repairs to panels by replacing broken hinges, thimbles of suitable size ,corroded nut, bolts etc including welding, drilling, cuttings etc complete and painting the panel by preparing the surfaces, applying two coat of synthetic enemelled paint, including making danger mark , supply and fix aluminium busbar set of four of suitable amperage as per requirement etc complete all as specified and directed.
Supply and fix in replacement of DOL starter for motor pump set upto 5HP complete all as specified and directed.
Supplying, laying, jointing and testing in replacement of existing size with pre-insulated multi standard copper conductor flat of size 25 sqmm, 3 core submersible cable and connected with suitable and required thimbles and nut bolts to panels complete all as specified and directed. Make: Finolex/Havells/Polycab/Grandlay/RR Kabel
All as per srl item 67 here in before but 16 Sqmm, 3 core.
All as per srl item 67 here in before but 10 Sqmm 3 core.
All as per srl item 67 here in before but 6 Sqmm 3 core.
Taking down carefully copper/aluminium point wiring for light,/fan/power socket complete ( fittings and fixtures such as switches, sockets, regulators, batten etc to be measured seaprately) removing material to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
Material and labour for Point wiring for one light/ fan controlled by one switch with 1.5 sqmm stranded copper conductor PVC insulated, unsheathed cable drawn through in PVC rigid non-metallic concealed conduit in walls / open on ceiling/beam/column not less than 20mm dia to be terminated in pressed steel terminal boxed with 3mm thick bakelite sheet top cover (Make : Hylam) for one light/ fan / bell point/ including 1.5 sqmm, (PVC insulated single core stranded copper earth continuity conductor, controlled by one switch and/or one regulator complete all as specified and directed. Note: 1. Switches and Regulators shall be measured and paid for separately). 2. Wiring shall be made as per colour code in IS for phase, neutral and earth).
All as per item Sr.No. 72 here in before but for socket out let 5 Amp on the same board with other switches
All as per item Sr.No. 72 here in before but for socket out let 5 Amp on independent board.
All as per item Sr.No. 72 here in before but for socket out let 15 Amp by using 2.5 sqmm copper conductor cable including earth continuity wire of size 1.5 sqmm
Supply and fix Switch Piano type, flush, single pole, 5 Amp complete all as sepecified and directed.
Supply and fix switch piano flush type 15 A single pole one way 230 V all as specified and directed
Supply and fix socket outlet flush type 3/6 pin suitable for 15 Amp plug top multipurpose 230 Volts all as specified and directed .
Supply and fix in replacement Fan Regulator modular type 230 volts complete all as specefied and directed.
Supply and fix in replacement Ceiling rose, surface bakelite, with three terminals complete all as specified and directed.
Supply and fix in replacement MCB DB 8 way 240 V Double Door, 200 Amp Bus bar , flushing mounting type , drilling holes for incoming , out going cables and making good the disturbed surface area as per existing area complete all as specified and directed.
Supply and fix in replacement MCB SP 6 to 32 Amp 240 V, breaking capacity 9/10 KA with proper thimbles complete all as specified and directed.
Supply and fix in replacement MCB SPN 40 amps ,240 V, breaking capacity 9/10 KA with proper thimbles complete all as specified and directed.
Material and labour in replacement for sub main wiring with two single core 2.5 Sqmm PVC insulated and unsheathed FR,stranded copper conductor cable drawn through in Existing PVC rigid non metallic concealed conduit 25 mm dia of suitable size incl 1.5 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed.
Supply and laying UPVC pipe/PPR pipe of size 25 mm for connection of chloronome plant to UG sump/header/delivery pipe for supply chalorine to potable water complete all as speciifed and directed.
Material and labour for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as speciifed and directed. Note : For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR part-I.
Material and labour in replacement providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other complete all as speciifed and directed.
Excavation in trenches not exc 1.50 metre wide and not exc 1.50 metre deep in soft/ loose soil for laying of pipe line and getting out complete all as speciifed and directed.
Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cm complete all as speciifed and directed.
Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as speciifed and directed.
Supply & laying in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 70 Sqmm 3.5 Core complete all as specified and directed.
Taking down UG cable of any size complete all as specified and directed.
Material and labour in replacement of GI pipe 50 light grade for protection of cable in road,drain crossing complete all as specified and directed .
Supply and fix in replacement gun metal globe or gate valve ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe of size 50mm bore complete all as speciifed and directed.
All as per item 94 here in before but 32mm bore
All as per item 94 here in before but 25mm bore
All as per item 94 here in before but 20mm bore
Supply and fix HDPE water tank of capacity 500 ltrs ISI marked including taking down existing complete all as speciifed and directed.
Material & labour and taking down, opening & rewinding of 3 phase 415 volts electric motor of capacity 3 to 5 HP with super enamelled copper winding wire as per existing gauge, cotton tape, leatherised strips, varnish, complete including testing after installation at site complete all as speciifed and directed.
Dismantaling & opening booster pump for repairing, making the same functional including installation & testing, complete all as speciifed and directed. Note : Spare parts required shall be measured and paid separately as supply only under the respective items .
Supply only shaft bush of booster pump suitable upto 5 HP complete all as speciifed and directed.
Supply only ball bearing and bushes suitable for pump upto 5 HP complete all as speciifed and directed.
Supply only bronze impeller complete all as speciifed and directed.
Supply only gear box drive complete all as speciifed and directed.
Supply only outer cover body complete all as speciifed and directed.
Supply and fix in replacement rubber coupling complete with CI part of booster pump of capacity upto 5 HP complete all as speciifed and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and making electric connection with PVC insulated copper conductor (multistrand) cable of 1.5 sq mm size complete all as speciifed and directed.
Repair/replacement of D.G. Exhaust pipe line of DG 500/400 KVA in syl by using SEAMLESS CS Pipe ,heavy class long radius bends of matching diameter along with necessary nut, bolt, washers and U-clamps etc thereon as required welding to be done as per best engineering practise by following high standard welding procedure, complete all as speciifed and directed.
Material & labour for attending any type regarding LT panel/ starters/ DGs complaint at SYL and Booster 1 and rectify the same, rates are also included for replcement of thimbles any type and any size with nut-bolts and spare parts with all connected items complete all as specified and directed. Note: 1. Complaint should be rectify within 04 Hrs otherwise a penalty of Rs. 250 per day will be imposed. 2. Spare parts will be measured and paid seperately.
Material & Labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level, filled around with layer of char coal dust and salt and connected to GI earth strip 32 x 6 mm by means of bolt, nut and check nuts and washers of galvanzied iron or steel and other end of the earth strip, connected to test point/equipment/panel and protected by galvanized iron pipe light grade 50mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, PCC 1:3:6 in chambers, RCC 1:2:4 in pit cover reinforced with 6mm dia deformed bars @ 15cm centre to centre both way including necessary excavation & earth work including demolition of existing complete all as specified & directed complete all as shown in electric plate No. 5 of SSR Pt-I. PCC chambers shall be constructed at leasts 1.5 mtr away from the earth electrode and pipe for watering. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost
Material and labour for caliberation of fuel injection pump by authorised dealer with replacement of worn out parts, testing and commissioning complete including alignment, plunger, packing kit, spring delivery valve etc. required to make the pump serviceable of DG set of capacity 400 KVA complete all as specified & directed. (The item rate includes transportation of pump from site to dealers workshop and back).
Material and labour for removing the radiator after disconnecting from engine, opening the parts of radiator for servicing and repairing/ replacement of unserviceable minor parts including brazing/ welding complete of DG set of capacity 400 KVA complete all as specified & directed. (The item rate includes transportation of radiator from site to wksp and back and refixing the radiator in position).
Supply and fixing in replacement of Turbo Charger Assy of DG set of capacity 400 KVA complete all as speciifed and directed.
Material and labour for Outdoor covers of LT panel board of existing size , outer shell made out of 3.1 mm thick MS sheet with front openable and back bolt openable lockable, followed by powder coated painting having thickness not less than 100 microns including dismantling and taking down rusted old UNSV LT Panel outdoor covers complete all as speciifed and directed.
Taking down air scour Rotary twin-lobe blower/compressor 1000cum/hr @ 4000mmWC from the foundation and shifting it to local workshop approved by accepting officer and filling the lub oil of Servo system 320 of IOC and ENCLO-320 of HPCL-03 ltrs and transporting back to SYL plant and refixing at the same place including connecting all electrical connections and testing complete all as speciifed and directed. Note : Spare parts required shall be measured and paid separately as supply only under the respective items
Supply only pressure relief valve and pressure gauge
Supply only suction filters
Supply only suction silencer
Supply only discharge silencer
Supply only V belts
Supply only coupling
Supply only pulley
Supply only anti vibration pad
Supply only shaft
Supply only bearings
Supply only gear drive
Supply and fixing in replacement line plan drawing high quality ACP sheet board of size appx 1.5m x 2 m complete all as speciifed and directed. Note: Details/description of printing words will be provided by department.
Supply and fixing in replacement high quality ACP sheet board at installations of size 4 m x 1m minimum with router cutting letter blue base of sheets and white colour acrylic letter with complete fitting of minimim 3 Nos LED lights of 20W of 4 feet complete all as speciifed and directed. Note: Details/description of printing words will be provided by department, secondly above quoted rates includes electrical as well as mechanical installation of board complete all as specfied and directed and no extra cost will be paid to the contractor. ( board for main syl plant)
Supply only PH and chlorine testing kit suitable for testing with O-Tolidine solution for regular test including solution, in the packing 500 ml complete all as specified and directed.
Complete removal of wild grass/ vegetation from sewage well and surrounding area from each Sewage well and making the surface clear, plain and spraying suitable chemical on the same clean area after removing and depositing the same at a distance not less than 50 mtr away from the site complete all as speciifed and directed. Note:-1. T&P machinary like JCB,hydra etc and chemical will be provided by the contractor without any extra cost to Govt. 2. No extra payment will be done to contractor for arranging these Items. 3. Conractor will make arrangement for reaching upto or inside well and repair the same if any damages at their cost. 4. Contractor should visit the site before quoting the rate.
Demolition of Plain Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as speciifed and directed.
Material and labour for rubber moulded machine pressed precast concrete interlocking paver with grey cement confirming to IS -15658-2000 of 60 mm thickness , M-35 grade as in path , hard standing etc laid over and 25 mm compacted sand cushioning( sand cushioning will be paid seperately) , including 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate including surface excavation over area n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil and remving excavated soil exc 50 mtr but n . exc 250 mtr , at Sewage installations as per requirement including demollition and removing of old material from the site for credit or disposal complete all as speciifed and directed.
Material and labour for sand cushioning layer of 25mm thick under interlocking tiles complete all as specified and directed.
Scraping old existing paint from pipe/angle iron /gate of different sizes including making smooth surface and primer and applying two coat of synthetic enamel paint of existing/approved colour complete all as specified and directed.
Supply and fix MS as in Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts and for shed rolled angle section use as a truss and for cattel trap including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting,welding or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Material and labour for rendering 10 mm thick in CM 1:3 as in ceiling finished even and smooth without using extra cement including taking down existing plaster complete all as specified and directed.
Material and labour for 15mm thick rendering in cement mortar (1:6) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement including taking down existing plaster complete all as specified and directed.
Material and labour for PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) for filling of road/path cutting etc complete all as specified and as directed.
Material and labour for brick work built in CM (1:6) straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) including demolition of existing complete all as specified and directed.
Material and labour for removing old paint from surface of LT panel by scraping,rubbing and making good surface for painting and applying powder coated spary painting with existing colour complete all as specified and as directed.
Material and labour for atending any type LT panels/Internal lights/Starters complaint at Sewage well and rectify the same, rates are also included for replcement of thimbles any type and any size with nut-bolts and cable jointing with tap, gland packing, greasing in pumps/valves with all connected items complete all as specified and as directed. Note: Complaint should be rectify within 06 Hrs otherwise a penalty of Rs. 250 per day will be imposed.
Notes for Ser Item No 142 & 143:- (i) Rate incl all items required for supply, installing , testing and commissioning of LT panel such as any no of contactor of suitable capacity required in star delta starter, time relay, single phase preventor, single pole MCB required for safety , thimbles, end joining kit etc complete. The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Cable will be entered in panels through gland. (vi) Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate.
Note:- Amount of credit of Rs. 121354.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in PDF form which will be deducted offline while acceptance of tender.
M/s Friends Engineering Works
LAKHANPAL ELECTRIC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .