| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 3A SOURENDRA MOHAN GHOSH SARANI MANGOE LANE KOLKATA 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹1.7 Cr | L1 | Accepted-AOC L1 Bidder. |
| 2 | L2₹1.7 Cr+₹2.2 L (1.29%)Rejected-AOC 403 404 DELPHI B WING HIRANANDANI BUSINESS PARK POWAI MUMBAI MAHARASHTRA 400076 | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | ₹1.7 Cr+₹2.2 L (1.29%) | L2 | Rejected-AOC L2 Bidder. |
| 3 | L3₹1.7 Cr+₹3.0 L (1.74%)Rejected-Finance | ₹1.7 Cr+₹3.0 L (1.74%) | L3 | Rejected-Finance L3 Bidder. |
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
14 Dec 2020, 2:00 pmClosed
O/O the EE, B.Ar.D, PHE Dte.
AB-30/1, Prafulla Kanan, Krishnapur, Kolkata - 700101.
Supply delivery installation demonstration and training on operation of various water quality testing equipment required for different water quality testing laboratories
2020_PHED_305894_1
WBPHED/EE/BArD/NIeQ-05/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
All Districts of West Bengal
Please refer Tender documents.
4 documents required · 4 mandatory
₹3.5 L
21 Jan 2021
23 Nov 2020
16 Dec 2020
23 Nov 2020
14 Dec 2020
23 Nov 2020
Amount
Supply, delivery, installation of UV-Visible dual beam with internal reference detector, programmable, Scanning with in-built thermal printer & suitable for Water quality analysis Spectrophotometer, 7-inch color touchscreen, fixed, high definition , 800 × 1280 pixels display, wavelength range:190 to 1100 nm, with an accuracy of 0.5 nm & repeatabiliyty: <±0.2 nm Spectral band width: 2 nm/better. Scanning speed: up to 1600 nm/min with data resolution of 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm. Detector: Dual silicon photodiodes; measuring methods: Absorbance , % transmittance, concentration; Range: –2A to +3.5A; <1000 %T to 0 %T; 9999 C. Detector: Dual silicon photodiodes; connectivity: Bluetooth, Ethernet, USB B for PC, USB A for External Memory. Touch screen wireless ready Keypad with wireless key board- integrated touch pad. Light source: Xenon lamp; Cell holders: Cell Holder- adjustable holder for Round cuvettes: 13, 16 and 24 mm ; Rectangular cuvettes: 10 fixed & integrated 20 to 100 mm variable pathlength cell holder fixation shall be magnetic type for easy replavement. The unit should be capable of storing user-defined programming methods (at least 25 GB or more internal storing space) & to be supplied with programming data of reday-to use spectrophotometric reagent tests (pre-loaded). The unit should be supplied with the touch screen system with wireless touch pad, variable pathlength cell holder, 10mm patlength mateched pair cell along with power cord, UPS for at least 15 minutes power backup, operating manual & a user guide in a pendrive in video form . The scope of work includes supply of the system with training of analysis of arsenic, Iron, Manganese to the user.Make: Thermo / Lovibond/ WTW or Equivalent
Supply, delivery, installation of Turbidity Meter with standard calibration solution & accessories, measuring cuvette, USB cable, carrying case & as per specification given in notice and direction of E.I.C. Range: 0,01 - 1100 NTU (Auto ranging). Resolution: 0.01 - 9.99 NTU = 0.01 NTU/ 10.0 - 99.9 NTU = 0.1 NTU/ 100 - 1100 NTU = 1 NTU. Calibration: 4 point auto calibration. Unit shall be supplied with required calibration solutions, spare battery, operating manual, video for calibration & as per specification in Notice & direction of E.I.C. Lovibond/Thermo-Eutech/WTW/Equiv
Supply, installation & demonstration of microprocessor based pH/mv-Redox-ORP/Temperature 700 Meter with automatic temperature compensation. The unit should be complete with pH electrode, electrode holder, temperature probe, power pack & start up calibration certified buffer, operating manual & as per specification in Notice & direction of E.I.C. Thermo-Eutech/Equivalent
Supply, installation & demonstration of basic salinity -Conductivity-TDS meter Cond 7110/StarA-212 with Cell Tetracon 325-Duraprobe 4 electrode conductivity cell & as per specification in Notice & direction of E.I.C. Thermo-Orion/WTW/Equivalent
Supply, delivery & demonstration of vertical Autoclave, double walled, radial locking arrangement, working chamber SS, lid & ring-SS, outer wall covered with SS sheet, complete with Automatic pressure cut off facility, steam release valve, low water level cut-off device, pressure gauge, safety valve, Automatic digital timer. Working chamber Size: 20" x 12". The supplies to be as per specification in Notice & direction of E.I.C. Relitech/Obromax/Equivalent
Supply, delivery & demonstration of Hot Air Oven working chamber size (Medium size) : 16"x16"X16". SS working chamber, temperature controlled by thermostat & indicated by in-built L-shaped thermometer. The supplies to be as per specification in Notice & direction of E.I.C. Relitech/Digilab/Equivalent
Supply, delivery, installation Distillation unit, Glass, with Heater & in-built low water level cut-ff system, Horizontal type structure. All glass of Borosilicate Glass. , 4 lit/hour capacity. To work on 220/230 volts. The necessary connector tubing for installation are to be included in the scope of supply. The supplies to be as per specification in Notice & direction of E.I.C. Riviera/Borosil/Equivalent
Supply, delivery, installation of Microprocessor based Analytical Balance, 210 gm capacity, 0.1 mg redability, with internal calibration facility, Air-shield, SS pan, Spirit level indicator & as per specification in Notice & direction of E.I.C. Shimadzu/ Equivalent
Supply, delivery & demonstration of Incubator, working chamber size (Medium size) : 16"x16"X18". SS working chamber,double walled unit with outer body made of MS sheet, rust proof duly powder coated and inner chamber made of Stainless Steel (304 Grade) sheet. Provided with adjustable Stainless Steel perforated shelves. The Double Walled Door shall be fitted with glass window to facilitate viewing inside chamber without disturbing the inner temperature and shall have synthetic rubber/ fiber gasket. Temperature control by Micro Processor Based (PID) Digital Temperature Indicator-cum-Controller (with display for Set Value and Present Value) for temperature control from +5º C ambient to 70ºC, ± 0.5ºC at 50ºC. Fitted with Air Circulating Fan. To be fitted with beaded heating elements placed in ribs, at bottom and sides for uniform heat distribution. To work on 220/230 volts AC supply. The supplies to be as per specification in Notice & direction of E.I.C. Relitech/Digilab/Equiv
Laboratory Hot plates, rectangular shapes 10"X 12". Body shall be made of thick mild steel sheet, & epoxy powder coated. The Hot Plate top shall be made of cast iron, Heavy duty heating elements are to be securely laid under the plate to operate on 220/230V AC supply. Temperature in controlled by energy regulators fitted with an indicator lamp for the mains. Supplied with cord and plug.
Magnetic stirrer, with a Fractional Horse Power motor mounted in a sheet metal housing, fitted with speed regulator, max. Speed 1200 RPM. Top plate shall be of stainless steel, cap 1 to 2 litre, supplied with PTFE coated stirring bar. The supplies to be as per specification in Notice & direction of E.I.C. Relitech/Digilab/Equiv
Vacuum Pump should be portable, oil free, noiseless, all parts to be made of die casted aluminium, Diaphragm shall be made of neoprene rubber, Flow: 15 lit/min, max vacuum of Mercury: 27", max pressure: 35 Psi, Motor: 1/16 HP, to be fitted with moisture trap & the pump shall be suitable for membrane filtration system without rupturing the membrane filter & can be used for bacteriological parameter of water testing as per IS 14543 The supplies to be as per specification in Notice & direction of E.I.C. Rivotek/Relitech/Tarson/equiv
Water bath made of SS, single hole, with concentric ring as reduction adaptor, with self ejecting type immersion heater suitable for preparation of chromogenic media. The supplies to be as per specification in Notice & direction of E.I.C. Relitech/Digilab/Equiv
Supply, Installation, demonstration of Microprocessor controlled Gas box upgrade for ICE 3500 AAS, complete with gas box with processor board & burner interface assembly, cables, Bracket, tube insert, Flow restrictor, hook & loop cable tie with mounting, required hose assay & Atomic Absorption Spray chamber kit & any other accessories required to install & smooth running of the system
Thermo Fisher Scientific India Pvt Ltd
SUNANDA ENVIROMENTAL INTERNATIONAL PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .