Karnataka Power Transmission Corporation Limited
Srinivas T
Replacement of existing age old/sluggish BHEL make 15 Nos of 11kV, 20kA Switchgears(MCVCB) by 11kV 31.5kA Switchgears (MCVCB) at 66/11kV Vijayanagar S/s, Mysuru District & Taluk.-Reserved for Category CAT-IIA-CALL-2
KPTCL/2025-26/SS/WORK_INDENT2862/CALL-2
KPTCL/2025-26/SS/WORK_INDENT2862/CALL-2
Reserved
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CEE Transmission Zone Office Mysuru
15 documents required · 15 mandatory
Mandating satisfactory completion as a prime contractor for at least one similar work of value not less than 25% of the cost of the contract. (Proceedings of the Government of Karnataka & Government order No. FD480EXP-12/2014 Bangalore dated 19.07.2014)
The Bidder shall be registered firm as Sole Proprietorship/Partnership/Pvt Ltd Company etc
For other than proprietorship, the Bidder shall furnish the registered partnership deed and Power of Attorney
Valid Caste Certificate in support of reserved tender participation
Valid Karnataka Residential Certificate
valid Super grade Electrical Contractor License issued by the Government of Karnataka as on the date of opening of techno-commercial bid (refer 2.3 of ITT)
Minimum Average Annual Turnover (MAAT) of the bidder for best one(01) year out of last preceding five financial years, shall not be less than Amount Put to Tender as per 3.2(a) of std tender documents(ITT).
Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under:Assessed Available Tender Capacity: (AxNx5-B)Where A-Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years (updated to FY 2024-2025) taking into account the completed as well as works in progress. N-Number of years prescribed for completion of the works for which tenders are invited.B-Value, at FY 2024-2025 price level of existing commitments (KPTCL & Non-KPTCL)and on-going works (KPTCL & Non-KPTCL) to be completed during the next 1(One)year.Note:(i)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.(ii)A self-declaration is to be uploaded by the Tenderer stating that the information with regard to assessed available tender capacity (Works on Hand) furnished are correct.
Even though the Tenderers meet the above criteria, they are subject to be disqualified if they have:- Made misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements and/or- Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc. and/or- Participated in the previous Tender for the same work and had quoted unreasonably high Tender prices and could not furnish rational justification.
Bidder shall ensure that soft copies of Power of Attorney, Letter of Undertaking, No Deviation CERTIFICATE as revised in Annexure , Any other undertaking / agreement (if applicable) are to be uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date as per 3.10(xviii) of ITT
Bidder shall ensure that soft copies of i. Letter of undertaking for Non performance ii. Letter of undertaking for Risk and Cost iii. Letter of undertaking for Litigation iv. Letter of undertaking to source the supply of equipment material from KPTCL approved Vendors only (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date as per 3.10(xviii) of ITT
Letter of undertaking to source the equipment/material for the work from the approved Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India (Annexure-XVI) ii. Letter of undertaking as per clause No.1.5 of Annexure-XVII iii. Letter of undertaking as per clause No.1.6 of Annexure-XVII (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids
ESI certificate
EPF Certificate
Shall upload valid GST Certificate and PAN copy
₹630
₹25,500
13 Feb 2026
13 Feb 2026
2 Mar 2026
25 Feb 2026
Sup01 LTAC panel (Indoor), 415V as per technical specification 1.00 No
Sup02 DC Distribution Panel (Indoor)
100A, SFU-01 No. (2) Outgoing 32A, SFU-15 Nos 1.00 No
Sup03 LT Distribution box for 100 kVA
with LT Protection Kit 1.00 No
Sup04 4 Core x 16 sqmm Copper Control cable 35.00 Mtr
Sup05 2 Core 16 Sqmm Copper control cable 145.00 Mtr
Sup06 4 Core x 6 sqmm Copper Control cable 2095.00 Mtr
Sup07 4 Core x 25 Sq mm Copper control cable 110.00 Mtr
Sup08 4 Core x 2.5 Sq mm Copper control cable 290.00 Mtr
Sup09 19 core x 2.5 sqmm Copper Control cable 1156.00 Mtr
Sup10 25,16,6,2.5, sqmm lugs for Copper Control cable 150.00 No
Sup11 50 25 75 mm Glands for Copper Control cable 100.00 No
Sup12 Multi Function Transducers(MFT) 15.00 No
Sup13 Opto Coupler 15.00 No
Sup14 Terminal Blocks (knife type) 120.00 No
Sup15 2.5 Sq-mm multistrand copper wire for CT termination 1035.00 Mtr
Sup16 2.5 Sq-mm multistrand copper wire 300.00 Mtr
Sup17 10 Copper core x 1.5sqmm Control Cable 204.00 Mtr
Sup18 10 core x 0.5sqmm Copper cable 379.00 Mtr
Sup19 1.5 Sqmm Grey wire 300.00 Mtr
Sup20 tinned copper lugs and crimping and wiring 1200.00 No
Sup21 C-type channel of size 50x100x50x6mm 7.50 Mtr
Sup22 heavy duty cable glands suitable for UG cable of 1.1 KV class 58.00 No
Sup23 CT TB's 90.00 No
Erection estimate
Err01 Erection and Commissioning of 11 kV switch gear of type MCVCB, 500 MVA, 31.5kA, 1600A 15.00 Nos
Err02 Testing & commissioning of switch gears 1.00 Nos
Err03 Erection of LTAC panel (Indoor), 415V 1.00 Nos
Err04 Testing & commissioning of LTAC panel (Indoor) 1.00 Nos
Err05 Erection of DC Distribution Panel (Indoor) 1.00 Nos
Err06 Testing & commissioning of DC distribution panel 1.00 Nos
Err07 Erection and commissioning of LT Distribution box for 100 kVA with MCB With LT Protection Kit 1.00 Nos
Err08 Supply & Laying 4 Core x 16 sqmm Copper Control cable 35.00 Mtr
Err09 Supply & Laying
2 Core 16 Sqmm Copper control cable 145.00 Mtr
Err10 Supply & Laying
4 Core x 6 sqmm Copper Control cable 2095.00 Mtr
Err11 Supply & Laying
4 Core x 25 Sq mm Copper control cable 110.00 Mtr
Err12 Supply & Laying
4 Core x 2.5 Sq mm Copper control cable 290.00 Mtr
Err13 Supply & Laying
19 core x 2.5sqmm Copper Control cable (New Cable) 1156.00 Mtr
Err14 Loading and Unloading
a) Loading of Control Cable available at Store
b) Unloading at Site
if Materials availed from store stock 3.00 MT
Err15 Transportation of Cable from Store and Returing of released materials to store 15.00 Km
Err16 Multi Function Transducers(MFT)(For SCADA REINTEGRATION Purpose)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: ... 15.00 Nos
Err17 Opto Coupler(For SCADA REINTEGRATION Purpose)
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5m... 15.00 Nos
Err18 Control Cable(For SCADA REINTEGRATION Purpose) - 10 Copper core x 1.5sqmm
(From remote contol desk to RTU)
(17mtrs x 12 nos = 204 mtrs) 204.00 Mtr
Err19 Signal Cable(For SCADA REINTEGRATION Purpose) - 10 Copper core x 0.5sqmm
Feeder to Feeder loop = 05mts x 1 nos =05 mtrs)
Remote control desk to RTU (for DI):17mtrs x 12 Nos =204 mtrs
RTU to B1&B2+Fee... 379.00 Mtr
Err20 1.5 Sqmm Grey wire for interfacing of DI and DO(For SCADA REINTEGRATION Purpose)
(20 mtrs for each panel)(20x15=300mtr) 300.00 Mtr
Err21 CT TB's - 6 nos for each panel
(1 x 6 = 6 nos)(For SCADA REINTEGRATION Purpose) 90.00 Nos
Err22 Miscellaneous items like, Ferrules, cable ties, insulation tape, & Labour for cutting, weldind, drilling, etc(For SCADA REINTEGRATION Purpose) 15.00 LS
Err23 Configuration of RTU and Engineering along with validation of data at SLDC(For SCADA REINTEGRATION Purpose) 15.00 Nos
Err24 Grounding of equipment with 50 x 6 mm G.I. Flat and connecting Equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and conn... 50.00 Rmtr
Err25 Decomissioning of existing 11kV Indoor / Outdoor Switchgear. 15.00 Per Panel
Err26 Decomissioning of existing 11kV Adaptor panel 2.00 Per Panel
Err27 De- wiring 11kV Indoor/Outdoor Switchgear 15.00 Per Panel
Err28 Releasing of unarmourd control cable 1219.00 Mtr
Err29 Decomissioning of detoriated Non Standard LTAC distribution(Indoor) panel 1.00 Nos
Err30 Decomissioning of detoriated Non Standard DCDB panel 1.00 Nos
Err31 Decomissioning of detoriated outdoor LT Distribution Box of 100KVA Auxilliary Transformer 1.00 Nos
Err32 Loading of 11 kV Switchgears other cable and materials
(Loading at Vijayanagara S/s)
Unloading of 11 kV Switchgears other cable and materials
(Unloading at KPTCL store, Hootagally) 6.00 MT
Err33 Transportation of released Breakers etc from 66/11kV Vijayanagara S/s to Divisional store, Hootagalli Mysore.
Station to weigh bridge and store vice versa 50.00 Km
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Adoption_of_Insurance.pdf
Others - CIRCULARS • 0.56 MB
2025-07-10-13-05-12Adoption_of_Insurance.pdf
Others - CIRCULARS • 0.56 MB
2025-12-03-15-23-01emd_performance.pdf
Others - CIRCULAR • 0.12 MB
NIT VIJAYANAGAR.pdf
Instructions to Tenderers • 0.67 MB
Tender Document vij.pdf
Tender Document • 2.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .