Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1 FOR ITE₹1,770Accepted-AOC | L1 FOR ITE | Accepted-AOC JUSTIFIED AND LOWER RATES | |
| 2 | L1 FOR ALL₹3.2 LAccepted-AOC JAGADHRI ROAD NEAR MAHAVIR CHOWK YAMUNA NAGAR HARYANA 135003 | YAMUNA NAGAR | YAMUNA NAGAR | HARYANA | 135003 | L1 FOR ALL | Accepted-AOC JUSTIFIED AND LOWER RATES |
Tender Value
Refer Docs
EMD Value
₹7,400
Closing Date
3 Feb 2022, 1:00 pmClosed
SE MM AND STORE
DCRTPP
AS PER TENDER DOC
2021_HBC_190676_1
POM-13321-SUPPLY OF MCB AND ELECTRICAL MATERIAL
Open Tender
Miscellaneous Goods
Supply
90 days
DCRTPP YAMUNA NAGAR
AS PER NIT
2 documents required · 2 mandatory
₹1,180
Yes
₹7,400
Yes
22 Jul 2022
1 Oct 2021
8 Feb 2022
1 Oct 2021
3 Feb 2022
1 Oct 2021
3-pole MCCB,Ue-415V,Icu-50KA,Iu-630Amp,50Hz,with shunt Release,Equivalent to ABB Model no-Space Tmax T5N 630,lu-690Amp,Vi-1000V,IEC-60947 PR 221DS,54396
Penal fan, Model:120x120x38mm, Axial fan, DC 24 V, Sleeve bearing, 0.20A, Impedence protected
320A TP, 50kA MCCB with thermal magnetic release
125A TP, 50kA MCCB with thermal magnetic release
63A TP, 50kA MCCB with thermal magnetic release
32A TP, 50kA MCCB with thermal magnetic release ,Equivalent to Schneider electric make Model no EZC100H
20A TP, 50kA MCCB with thermal magnetic release
2A SP, 10kA MCB
6A, SP, 10kA MCB
32A TP Contactor with 2 NO+2NC AUX, 110V AC,Equivalent to Schneider electric make Model no LC1D32,Aux contact-LADN11 for 2NO+2NC
415/230V, 500V Control Transformer
1-1.6Amp MPCB,Equivalent to Schneider mode no-GV2ME06
9A TP CONTACTOR WITH 3NO+1NC AUX, 110V AC,Equivalent to Schneider electric make Model no LC1009, 3NO+1NC, Aux contact no-LADN20
Step Down Transformer 500V: 5V , 5VA
Step Down Transformer 415V: 24V , 100VA
CT (Ratio-450A:1A) 10VA/2" Dia
Pri-Amp Meter- (96 Sq mm), Red mark at 415A, Range: 0-450 Amps FSD:1A
PRI-Volt Meter- (96 sq mm). Range: 0-500
Secondary mA Meter (96sqmm), Rated mA mean=1VDC (Range: 0 to 1600mA, FSD:1.14 VDC, Red mark on 1400mA)
Secondary KV Meter (96sqmm), Range: 0 to 120 KV FSD: 0.48mA, Red mark on 100kV)
500A, 1400 PIV Thyristors set (shall be fitted within existing heat sink) Thyristor Capsule assy type in anti-paralledl back to back connection. Please ask if need particular data of existing heat sink.
BE LIGHTNING SYSTEM PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .