Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹16.3 L+₹36,297.50 (2.28%)Rejected-Finance | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹17.4 L+₹1.4 L (9.06%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹18.9 L+₹3.0 L (18.6%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹19.8 L+₹3.8 L (24.0%)Rejected-Finance | L5 | Rejected-Finance Unsuccessful bidder |
| Sl No | Description | Qty | Unit | K K Construction Co L6 | BCL L2 | M/S GN ENTERPRISE L5 | M/S H. I. ENTERPRISE L4 | SHANKAR ENTERPRISE L1 | sanjay upadhya L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed | 303 | Sqm | 33 ₹9,999 | 10 ₹3,030 Lowest | 15 ₹4,545 | 20 ₹6,060 | 20 ₹6,060 | 10 ₹3,030 Lowest |
| 2.00 | Dismantling framed work timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as directed. | 294 | RM | 15 ₹4,410 | 5 ₹1,470 Lowest | 735 ₹2,16,090 | 170 ₹49,980 | 20 ₹5,880 | 10 ₹2,940 |
| 3.00 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed. | 220 | Sqm | 25 ₹5,500 | 10 ₹2,200 Lowest | 10 ₹2,200 Lowest | 45 ₹9,900 | 20 ₹4,400 | 10 ₹2,200 Lowest |
| 4.00 | Demolition of reed, lathing, single or double, including battens and plaster or chiken wire lathing and RCC jafari/jailies complet all as specified and directed. | 130 | Sqm | 120 ₹15,600 | 10 ₹1,300 Lowest | 10 ₹1,300 Lowest | 300 ₹39,000 | 10 ₹1,300 Lowest | 20 ₹2,600 |
| 5.00 | Demolition of brick work built in cement mortor including all quoins, arches, pillars etc and all as specified . | 6 | Cum | 650 ₹3,900 | 150 ₹900 Lowest | 200 ₹1,200 | 1,550 ₹9,300 | 300 ₹1,800 | 200 ₹1,200 |
| 6.00 | Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed | 40 | Sqm | 100 ₹4,000 | 10 ₹400 Lowest | 10 ₹400 Lowest | 90 ₹3,600 | 10 ₹400 Lowest | 10 ₹400 Lowest |
| 7.00 | Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. | 2 | Each | 400 ₹800 | 60 ₹120 | 30 ₹60 Lowest | 300 ₹600 | 50 ₹100 | 100 ₹200 |
| 8.00 | Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. | 7 | Each | 380 ₹2,660 | 50 ₹350 | 30 ₹210 Lowest | 260 ₹1,820 | 50 ₹350 | 100 ₹700 |
| 9.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. | 215 | Sqm | 100 ₹21,500 | 10 ₹2,150 Lowest | 10 ₹2,150 Lowest | 95 ₹20,425 | 20 ₹4,300 | 10 ₹2,150 Lowest |
| 10.00 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed. | 2.25 | Cum | 850 ₹1,912.5 | 150 ₹337.5 Lowest | 300 ₹675 | 1,350 ₹3,037.5 | 300 ₹675 | 300 ₹675 |
Tender Value
₹23.5 L
EMD Value
₹46,980
Closing Date
16 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
SPL REPAIR TO BLDG NO T-265/01 AT CERTAIN LOCATION OF MISA CAMP UNDER GE (S) TEZPUR
2025_MES_731610_1
CWE/TEZ(S)/T-58 of 25-26
Open Tender
Civil Works
Item Rate
180 days
GE (S) Tezpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (S) Tezpur
₹46,980
Yes
8 Dec 2025
18 Sept 2025
18 Oct 2025
18 Sept 2025
16 Oct 2025
2 Oct 2025
Amount
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed
Dismantling framed work timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
Demolition of reed, lathing, single or double, including battens and plaster or chiken wire lathing and RCC jafari/jailies complet all as specified and directed.
Demolition of brick work built in cement mortor including all quoins, arches, pillars etc and all as specified .
Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified & as directed.
M&L for brickwork with subclass‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders,bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed
M&L for reinforced cement concrete Nominal Mix M-25 as in beams, cantilevers, bressummers and lintels over 1.5m span complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for rendering 10 mm thick on faces of brick work or concrete surface in CM (1:6), finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering with cement mortar (1:4) on fair faces of brick work in two layers (10mm & 5mm)seperately mixed with water proofing compound in top layer as per manufacturer's instructions and finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
Supply only liquid water proofing compound complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer over and including a coat of 1mm thick white putty complete all as specified and directed.
M & L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of primer over and including a coat of 1mm thick white putty complete all as specified and directed.
M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over a coat of 1 mm thick wall care putty suitable for exterior emulsion paint Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed.
M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over a coat of 1 mm thick wall care putty suitable for exterior emulsion paint Allow 6-8 hrs to dry the surface in both the coats of paint including complete removal of existing treatment on wall/ roof projections including facia,cornices etc by scrapping to make surface clean,free from dust,loose paint etc by skilled labour complete all as specified and directed.
S & F factory made steel windows including box type hinges with steel handles & steel pag stay complete (without glazing bars), dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed.
S & F factory made steel windows with side hung shutters including box type hinges with steel handles & steel pag stay complete (with glazing bars), dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F 125mmx60mm size and 1.60 mm thick pressed steel frames for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate etc including applying a coat of tar in inner surface ,red oxide to outer surface and filling the frame using PCC M-10 using 12.50 mm graded stone aggregate complete all as directed.
M&L for PCC (1:3:6) type C1 20mm graded aggregate as in padding ,holdfast/filling of chowkhats or similar work complete all as specified and directed.
S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc complete and size of member of shutters as specified in SSR Part-I (2009) section 8 all complete all as specified and directed.
S & F in stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed
M & L for 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all specified and as directed.
S & F of 150 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed.
S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F of floor door stopper 140mm (overall length of cover plate) of aluminum alloy body and tongue, anodized, with hard drawn steel spring fixed in floor including taking down the old one complete all as directed.
M&L for preparation of new wooden surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of primer complete all as directed.
S & F of powder coated mild steel drapery rod of 20 mm inner dia of approved colour with and including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends fixed with PVC rawl plug and steel screws on walls/beam, complete all as directed.
M & L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado/skirting complete all as specified and directed.
M&L 16-18 mm thick pre-polished Kota stone slab area of each tile exc. 0.18 Sqm but not exc. 0.36 sqm,as in flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.
M&L 16-18 mm thick pre-polished Kota stone slab area of each tile exc. 0.18 Sqm but not exc. 0.36 sqm,as in skirting over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.
M & L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W(Gde E-250) quality 'A' complete all as specifed and directed.
M&L for preparation of steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxide primer complete all as specified and directed
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of hangers 6mm dia GI (upto 1200 mm length ) adjusting level fixed to roof slabs or steel framed structure or truss by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed
S & F of GI powder coated snap grid frame work for false ceiling all as specified size of grid 605x605mm with GI angle 25x25x1.5mm, main 'T' of 38x25x1.5mm and secondary 'T' 25x25x1.2mm complete all as directed.
M & L for 4mm thick non asbestos fibre cement building boards, fixed or laid/inserted to timber /GI/Aluminium framework with screws fixed in ceiling flat or sloping complete all as specified & directed.
M&L for 150 mm thick PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in sub base to floors/paths/paving/hardstanding finishing cement concrete surface even and fair without using extra cement complete all as specified and directed.
M & L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler board and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 100mm thick concrete slab complete all as specified and directed.
M&L 75 mm thick Cement concrete type C2 1:3:6 (using 20 mm graded stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished cement concrete surface even and smooth without using extra cement and providing joints throughout thickness of plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and two parts of sand by weight complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches,ceiling roses,pendants,regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including modular GI boxes of suitable sizes including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
All as per item No. 54 here-in-before but one 3 pin 5 amps switch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. 54 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
S&F Modular type switch 6 Amps 230V AC single module one way complete all as specified and as directed.
S&F Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed.
S&F Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed.
S&F Modular type switch 16 Amps 230V AC single module one way complete all as specified and as directed.
S&F Ceiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed.
S&F Modular type fan regulator Step type,100 Watt, one module/ two module, 230V AC complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 2 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 4 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 8 modules complete all as specified and as directed.
Supplying and fixing in repair two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked) concealed including 6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. MAKE: KEI/ Polycab/RR Cables & equivalents. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). Note : Two run of 6 sqmm wire with one run of 6 sqmm and one run of conduit pipe shall be measured against one unit.
Supply and fixed in repair 18 W LED light fitting wall mounted batten 4'ft , minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed.
Supply and fixed in repair security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
Supply and fixed in repair recessed mounted 2' x 2 ' LED luminaire 36 watts for grid ceiling minimumm lumen output 100 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed.
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed.
Supply and fixed in repairs MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Taking down of AC ceiling / exhaust fan of any sweep & any height and opening the fan and oiling, greasing and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and hanging it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan as directed by the Engr-in-Charge.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.
Supply, laying / fixing / connecting, testing and commissioning of 16 Sqmm 4 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
BCL (BID ID -3446538)
sanjay upadhya (BID ID -3446601)
M/S H. I. ENTERPRISE (BID ID -3451197)
M/S GN ENTERPRISE (BID ID -3446552)
K K Construction Co (BID ID -3446019)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .