Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹5.8 L+₹12,911 (2.26%)Rejected-Finance 6201 M G ROAD KOLKATA 700 009 | KOLKATA | KOLKATA | WEST BENGAL | 700009 | L2 | Rejected-Finance Rejected ,as stood L2 | |
| 3 | L3₹5.9 L+₹22,487 (3.94%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance Rejected ,as stood L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected_Technical |
Tender Value
₹5.6 L
EMD Value
₹11,200
Closing Date
2 Nov 2024, 12:00 pmClosed
O/O Exe. Engr, Kolkta South Health El. Divn, PWDte
75 Diamond Harbour Road Kolkata 23
Urgent Requirement for Electrical Installation with allied Air Conditioning works for Converting the old ENT OPD Seminer Room into Two Separate Head Neck Surgery OPD Room at ground floor of Ronald Ross Building within the compound of IPGMER SSKM
2024_WBPWD_751555_1
WBPWD/EE-I/KSHED/Q54/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
SSKM Hospital Kolkata
Please refer Tender documents.
3 documents required · 3 mandatory
₹11,200
O/O Exe. Engr, Kolkta South Health El. Divn, PWDte
9 Apr 2025
14 Sept 2024
5 Nov 2024
14 Sept 2024
2 Nov 2024
20 Sept 2024
20 Sept 2024
Amount
Electrical Installation work
Dismantling the existing damaged BDB, switch board, wiring, cable, fittings & fixture as required very carefully & carrying the same to safe place as per direction of EIC.
Supply & Fxing Double Door 8-Way TPN MCB DB in S.S. enclosure (min 1.5mm thick) with IP-42/43 protection flushed in wall consisting with 1 No., 100 A. and 1 No. 63 A. 4-Pole MCB as incomer & 18 nos., 16 - 32 A. SP MCB as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar , both side cable end box and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necsy. earthing attachment. (Make:- Legrand / Schneider).
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Polycab / Havells) partly in 20mm size PVC rigid conduit 'FR' (Precision/Polycab make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex / Polycab / Havells) for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 75x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] - Av. Run 9 Mtrs.
On Board
Supply & Fxing 240V., T.L. Fittings complete with all accessories and necy. connection by 2 x1.5mm² PVC insulated Cu. Wire & painting as follows:-
a) Single industrial box type luminaire with CRCA body . incl S&F 1x 18/20 watts 4 ft LED tube lamp (Lamp Make:-Wipro, Cat no. LL1381-650 / Philips, Cat - 18W 865T81/Crompton LKT8-20] .(Fitting Make : Wipro, Cat - WIO141208 / Philips, Cat TMC501 P 1xT-LED 22W P3241/Crompton IGP 131LK8-16)
b) Twin industrial box type luminaire with CRCA body incl. S&F 2x 20 watts 4 ft LED tube lamp [Lamp Make:-Wipro, Cat no. LL1381-650 / Philips, Cat - 18W 865T81/Crompton LKT8-20](Fitting Make : Wipro, Cat - WIO142208 / Philips, Cat TMC501 P 2xT-LED 22W P3241/Crompton IGP 132LK8-16)
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Anchor) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Polycab / Havells) in 20mm/25mm size PVC rigid conduit 'FR' (Precision / Polycab make) incl. necy. fittings as required
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC (VTPN to TPN DB).
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC (AC Machine).
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (Power Plug).
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (Power Plug).
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
S & F 250V 25A Timer controller for AC machine in SS double door (IP 42/43) 2+10-way DB enclosure (Make:- LK/Schnider/ABB Elegance) with S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :- i) 10kA, C-Curve, 240V, 25A DPMCB (LK/Siemens) --- 1 No ii) 24 Hr programmable Digital Timer (LK make cat no 67DDT0) ---- 1 No iii) 3 pole power contractor (LK make cat no MNX 22/230V) with 1 NO +1 NC additional contact block ---- 2 sets iv) 2 Moduler AC motor stater (Make:- Legrand/Myrius) ---- 1 No. v) 2 Module plate with cover (Make :- Legrand/Myrius) -- 1 No vi) 20A Auto-Off-Bipass SPDT toggle switch (Approved/reputed make) ---- 2 Nos. vii) 10A SPST Moduler type switch (Make :- Legrand/Myrius) - 1 No. viii)Outgoing connector make ELMAX (Approved/reputed make) - 2 Nos (Single phase Twin timer)
Part: B (SITC of Airconditioning System):
SITC of 2.0 Tr capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 No. Rotary compressor, 1 no. IDU of rated power supply -230V-1ph-50Hz., 1 no. ODU of rated power supply - 230V, 1ph, 50Hz. Air-flow/per IDU:- 800CFM. (Make:Daikin / Mitshubishi Electric / O General) incl. charging of refrigerant R32 / R410 A / R410C
Supply, fabrication & fixing of 2 Nos. M.S Equal Angle of 6mm thick of Size (50mm X 50mm) of 2 m length for making platform for installation 2 Nos of outdoor unit of 2.0/1.5 TR concealed type Split Air Conditioner incl. drilling 2nos hole in each channel including making necessary guarding arrangement of outdoor unit as per site condition as per direction of EIC
Supply & fixing of HVAC grade copper pipe of following sizes for liquid and gas line between ODU and IDU (Make - Ryoku/Nippon):-
(a) 5/8" (gas line).
(b) 1/4" (liquid line).
Supply & fixing of Nitril Rubber insulation for refrigerant copper pipe minimum thickness 9 mm. incl. all accessories as per direction of EIC. (Make - Supreme/Aroflex):-
(a) 5/8" (gas line).
(b) 1/4" (liquid line).
Supply & Laying of 3 core 2.5 sq.mm PVC insulated Copper Cable ("FR") on wall incl. making connections as per direction of EIC.(As Control Cable from ODU to IDU ) ( Make : Havells/ Finolex/ Polycab)
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector,6 mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
With out angle iron support
100x50x1.25mm (18SWG) --- 2 Nos.
Supply & laying of 25 mm dia PVC Drain Pipe (Medium) including S&F necessary fittings (Make: Supreme/ Oriplast/ Finolex)
TERMS & CONDITIONS :- The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
SUMAN ENTERPRISE (BID ID -5735469)
M/s Singh Electrical Works (BID ID -5638101)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .