| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-Finance | L1 | Accepted-Finance Being L1 Bidder | |
| 2 | L2₹12.8 L+₹37,985 (3.07%)Rejected-Finance | L2 | Rejected-Finance Being L2 Bidder | |
| 3 | L3₹14.7 L+₹2.4 L (19.0%)Rejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L3 | Rejected-Finance Being L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹29,848
Closing Date
10 Jul 2025, 1:00 pmClosed
EE,NORTH 24 PARGANAS ELECTRICAL DIVISION,PWDte.
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059.
Proposed Construction of 3 Storied Office - cum - residential building of Deputy Central Intelligence Officer, Subsidiary Intelligence Bureau, Barasat, North 24 Parganas. Miscellaneous E.I. Work.
2025_WBPWD_867498_1
WBPWD/EE/N24/EL/e-NIQ- 21/25-26
Open Tender
MISC ELECTRICAL WORKS
Item Rate
45 days
Barasat
Please refer Tender documents.
4 documents required · 4 mandatory
₹29,848
NORTH 24 PARGANAS ELECTRICAL DIVISION
13 Aug 2025
20 Jun 2025
14 Jul 2025
20 Jun 2025
10 Jul 2025
26 Jun 2025
25 Jun 2025
Amount
PART -- A ( SITC OF DG SET AND ALLIED E.I. WORK ) SUB-HEAD 1 -- SITC OF DG SET Description of work: Supply, Installation, Commissioning & Testing of 30 kVA, 3 Phase Diesel Generator Set with AMF Control Panel ,CPCB-IV+ Approved engine and its connected accessories at HVF Estate as per Technical Specifications-
DIESEL ENGINE
Make: Cummins/Mahindra/Koel Green/Greaves/Volvo/Parkins/ Ashok Layland/Eicher.
Rated Capacity in KVA : 30 KVA
No. of phase: Three Phase
Rated capacity of Engine: minimum 42 BHP
Rated Engine power: 100 % of the required powered at STP(Standard Temperature Pressure) i.e. equal to (Nominal Rated Capacity (KVA) of power generator + Any Auxilary power Consumption by the Power generator) x Power factor(0.8) /Alternator efficiency
Type of engine cooling: Liquid cooled
Type of Governor : Electronic
No. of Cylinders: 4
No. of Strokes: 4
Rated RPM of Engine:1500
Fuel Type : High Speed Diesel(HSD)
Over load capacity: Engine is capable of delivering an output of 10% in excess of rated KVA for a period of one hour in any period of 12 hours continous running.
Specific fuel consumption: 6.9 l/h
Starting voltage: 12V
Salient futures of engine: Turbo charged Engine, Direct injection Fuel System.
GOVERNING CLASS
Class of Governor : A2 or better
Maximum Change of Speed as a Percentage of Rated Speed on suddenly taking-off the rated load (Transient) : 15
Maximum Recovery Time in Seconds on suddenly taking-off the rated load(Transient) : 15 second
Maximum Change of Speed as a Percentage of Rated Speed on suddenly taking-off the rated load (Permanent): 5
Maximum Change of Speed as a Percentage of Rated Speed On a change of load, both on and off , by all steps of 25 percent of the rated load (Transient): 4
Maximum RecoveryTime in Seconds on a change of load, both on and off , by all steps of 25 percent of the rated load (Transient) : 5 second
Maximum Change of Speed as a Percentageof Rated Speed On a change of load, both on and off , by all steps of 25 percent of the rated load (Permanent): 1.5
ALTERNATOR
Make: Koel Green/Stamford/Leroy Somer/ Crompton Greaves/ABB/Alstom.
Rating of AC generator : 30 KVA
Alternator Voltage Rating : 415V
Rated Power Factor : 0.8
Efficiency at rated power factor at 75% of full load: 90.2 percent
The alternator should conform to IS 13364(part 2) or any latest standard
Type of Alternator : Brushless
Voltage regulation : VG 3
Class of Protection : IP 23
Class of Insulation: H
CONTROL PANEL
Type: AMF Control Panel
Location: Inside the canopy.
IP Rating of control panel: IP-53
Display meters in the control panel: Multifunctional Digital Display meter(displaying voltage,current,Frequency,power factor)
Displayed Parameters Features: Control panel shall have displayed parameters of Engine Speed, Lube oil pressure, Coolant/cylinder head Temperature,Engine running hours, Engine battery voltage, Engine Running status, Generator Voltage (Ph-Ph),Generator Voltage (Ph-N), Generator apparent Power(kVA), Generator active Power(kW), Power factor, Frequency, Fuel level, Event log, Control supply Voltage.
Other Devices in the control panel: Required switches and cutout, MCB, Battery charger of appropriate rating shall be provided in the control panel.
Indicators: Low lub oil pressure, High water/coolant/Cylinder head temperature, low fuel level, over speed.
ACOUSTIC ENCLOSURE
Acoustic Enclosure: Inclusive in the scope of supply
Sheet Thickness:1.6 mm
Thickness of Insulatin: 40mm
Density of insulation: Minimum 32 kg/cubic mtr
Noise Level : 75dB
FUEL TANK
Fuel Tank capacity : Minimum 75 Ltrs.
Number of Fuel Tank: 01
Fuel Tank Sheet Material Thickness: 2 mm
Fuel Tank Fabricated Material : MS sheet
Fuel Tank Features: Fuel Tank capacity is sufficient for 8 hrs of running at full load
BATTERY
Battery Type & specification: low maintenance free to IS:14257 for high cranking performance Battery shall be provided .
Number of Batteries: 01
Battery Capacity (AH): 90AH
Salient Feature of power generator: Glass window on Acoustic enclosure in front of the control, Emergency stop outside the Acoustic Enclosure.
TRAILER: Not Applicable
General Technical Requirements (GTR)
Power Generator shall be complete with Diesel Engine, Alternator and AMF Control Panel along with Acoustic Enclosure. Diesel engine and alternator shall be closely coupled or provided with flexible coupling and mounted on a base plate / M.S. frame of robust in construction.
Anti-Vibration mountings shall be provided for complete Power Generator in case of flexible couplinIg. In case of direct coupling Anti-Vibration mountings shall be provided for the Engine as well as the alternator.
Power Generator should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc.
Automatic Mains Failure (AMF) control panel, shall be able to start up the Power Generator and transfer the load on to the Power Generator on mains failure without requiring any human intervention. Similarly on restoration of mains supply, it shall be able to transfer the load to mains supply and switch off the Power Generator automatically
Control Panel , shall be equipped with suitableVoltmeter, Ammeter, Frequency meter, power factor meter (these items can be alternatively supplied in one multifunctional digital display meter), battery charger, indicators, various switches and cutout / MCB / MCCB / Contactor / Circuit breaker for the DG output of appropriate rating and accuracy class as per trade practice for better utility.
Acoustic Enclosure shall be made of Pre-treated and Powder coated CRCA Sheet. The sheet shall be Pre-treated and Powder coated with weather-proof paint. The Acoustic Enclosure shall be vermin proof. The enclosure shall accommodate the fuel tank of the Power Generator to make the system compact.
Power Generators shall meet the requirements of Environmental (Protection) Rules 1986 as laid down by Ministry of Environment & Forests read with GSR 371 (E) dated 17.5.2002,GSR520(E) dated 1.7.2003 , No.448 (E)dated 12.07.2004 , GSR 771(E) dated 11.12.2013 GSR232(E)dated 31.03.2014, Gazette Notification No.167 dated. 31.03.2014 and Gazette Notification No. 578 dated. 11.11.2014 in respect of noise and emission norms. The latest amendments to above GSRs shall be applicable as amended by Ministry of Environment and Forest.
Supply of Fuel tank of suitable capacity, sufficient for minimum 8 hours running the Power Generator, is inclusive in the scope of supply. Fuel Tank shall be complete with fuel piping (between fuel tank and diesel engine), valves, level indications and all standard accessories. MS pipes, heavy class of suitable dia conforming to IS 1239 (Part-1) - latest shall be used for fuel piping.
Scope of Installation
Installation: With Installation inclusive in the scope of supply
Installation of Power Generators shall be done by the seller. The installation work of Power Generator and its constituent parts shall be generally conforming to CPWD General Specifi cation for Electrical Works, Part - VII - latest. b) Foundation shall be constructed by the seller. Foundation shall be of PCC type with the ratio of 4:2:1. The length and breadth of the foundation shall be 300mm more from the respective length and breadth of the Power Generator. The height of the foundation shall be 400 mm, i.e., 200 mm below and 200 mm above the ground level. All the materials / labour required for foundation work shall be supplied by the seller.
Supply, laying and termination of inter connecting power and control cable shall be done by the seller. The cable supplied shall be ISI marked heavy duty PVC insulated, armoured cable, with PVC outer Sheath , with aluminium conductor having insulation of PVC compound type -C, suitable for rated voltage upto and including 1100 volts and conforming to IS: 1554 (Part-1) latest. Total length of the cable supplied by the seller shall be 60 metres of minimum 3.5CX35 sqmm for each Power Generator.
Supply & delivery of 100 Ltr of Diesel for testing and commissioning purpose.
SUB-HEAD 2 -- BDB,PDB,VTPN ETC Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc 100 A, TPN Changeover Switch (Make-L&T) [ 3(a)/D-2 ]
SUB HEAD 3 -- SUPPLY OF CABLES Supply of 4 Core PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR ] 4 core 25 Sq. mm Cable. [ NS ] [ From Main Switch to Changeover to DG AMF ]
SUB HEAD 4 -- LAYING OF CABLES Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as per GS. -- [ 2(b)/F-1 ] [ For 4 Core 25 Sq mm. ]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damagesas per GS. -- From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. [ 5(i)/F-3 ] [ For 4 core 25 Sq mm. ]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space as per GS.-- [ 1(a)/F-2 ] [ For 4 core 25 Sq mm. ]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry as per GS. For 4 core 25 Sq. mm. [ 7(c) /F- 4 ]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make) as per GS. 4 core 25 Sq mm. cable [ 8(b)/(xiii)/F-5 ]
Making holes on RCC ceiling 125 mm depth having dia of following sizes : 125 mm depth, 50 mm dia [ 9(b)/E-3 ]
Additional charges for cutting the RCC Road and mending good the damages as to original finish after laying the cable through the existing GI Pipe protection as per size given below -- 50 mm dia [ NS ]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. -- 50 mm dia GI Pipe [ 11(d)/F-6 ]
SUB HEAD 5 -- EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [ 1(a)/G-1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI - Medium GI Pipe [ 2(a)/ G-1 ] [ For Neutral Earthing & Body Earthing ]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall as per GS. [ 4(b)/G-2 ]
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [ 5(d)/G-3 ]
Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36cm X86.36cmX46cm deep(below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside)CI hinged inspection cover of size 36.56cmX35.56cm with locking arrangement ,GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [ 3(a)/G-2 ]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode. [ 3(b)/G-2 ]
SUB HEAD 6 -- MISCELENEOUS Supply & Laying of 1.1 KV, one no. 10 core 2.5 Sq mm PVC/A Copper Cable in an underground trench 460mm wide x 760mm avg depth with brick protection on the top of the cable with 8 Nos brick per meter incl. filling the space between the brick & cable and also th trench ill shifted soil levelling up and restoring surface dully rammed. -- [ From DG set to AMF panel ]
Supply & Laying of 1.1 kv, grade single Core 2 x 6 Sqmm PVC insulated Copper wire in EI Conduit & Painting [ From AMF Panel to Battery. ]
Supply and Fixing UPVC pipe of 40 mm dia. including necessary fittings as required. (approved make)
Supply and Fixing UPVC Elbow of 40 mm dia. including necessary fittings as required. (approved make)
Supply and Laying of MS pipe ( Medium Gauge ) for exhaust incl. S & F of Fixing materials such as flanges , gaskets, angles, nut, bolts & Washers etc. incl. all necy. Bend supports and clamps, anti vibration mounting insulation of exhaust system with 50 mm. thick mineral wool covered with wire mesh and aluminium cladding (as per CPCB) as per direction of EIC. of following dimension : a) 100 mm dia
b) 150 mm dia
S & F 8' length exhaust pipe of 100 mm dia M.S. black pipe including connection with the existing siliencer attached with the flexible coupter and S &.F Flange nuts bolts & washers etc. & necessary fixing materials etc as required incl. making hole on wall and mending good the damages with finishing.
PART -- B ( S.I.T.C. WORK OF AC MACHINE ) Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity-5.4 kW (Minimum) Minimum ISEER 3.8, BEE level 3-Star(min)[1st July22 to 31st December 2025] IS Compliance-IS-1391(Part-1 & Part-11) with all amendment Refrigerant R410A/R32 Compressor-Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 48°C and above Air Flow: 600 CFM (Minimum) Power supply -230V, 50Hz (±tolerance asper applicable standard), as directed by EIC. The scope of work is also includes supply and fixing of the following: (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape-3 mtr (ii) Necessary 3/4 core copper cable (FRLS type make: Finolex/RR Kable/Polycab/Havells/Gloster) 3mtr and 230V. 25A, 3pin plug top with indicator (Anchor/North West/Legrand/Havells) Make: General/Daikin/Mitsubishi Electric/Blue Star/Voltas/Carrier]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above HI Wall Split AC machine after making hole in wall etc. as per direction of EIC including supply of required Refrigant, S & F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm. MS angle iron frame for outdoor unit ( or arrangement recomended by Manufacturer ), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc. as per direction of EIC. [ NS ]
S & F of additional following items for length exceeding 3 mtr. For complete installation and commissioning of above AC machine. (i) Supply & Fixing of extra Refrigerant pipe (as requisite dia) with nitrite rubber insulation and wrapping tape (each mtr. Refrigerant pipe will include cost of 1 meter liquid pipe line and 1 mtr. gas pipe line of required dia and other accessories as required). [ NS ]
S & F of additional following items for length exceeding 3 mtr. For complete installation and commissioning of above AC machine. (i) 2.5 sqmm, 3/4 core copper cable (FRLS type, Make - Polycab/Finolex/RR Kabel). [ NS ]
Supply & Laying Soft Drawn PVC Drain pipe 19 mm. dia with proper supports & brackets as per direction of EIC. (Make - Suprime/Oriplast). [ NS ]
PART -- C ( LIGHTNING ARRESTOR ) S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered/ welded with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1), including thimble joints of 7/16 SWG wire and (25 x 6) mm GI strip with SS nuts, bolts & washers. (P-J-2/Item-14 + NS)
Supply & fixing of 25 mm x 6 mm thick GI (Hot Dip) flat / strips for Horizontal & Vertical run on wall / floor with GI shaddles as required including drilling holes, bolts, nuts, washers, etc./ and mending good the damages to building works . (Page : G-3/Item-5d).
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: (P:J-1/Item-4) i) Length upto 0.5 Mtr
ii) Length above 0.5 Mtr
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. (P : J-1/Item-7)
Supply & Fixing of Testing Joints by 25 mm x 6 mm thick GI (Hot Dip) strip 125 mm long on wall after making suitable arrangement to establish a clearance of 50mm from wall for making junction connection with vertical conductor and conductor from earth electrode complete with S & F GI bolts, nuts, check-nuts, spring washers etc. as required. (Rate arrived from G.S. Page :J-2/Item-13)
Earthing with 65 mm dia GI pipe (TATA-Medium) 3.0 Mts. long with welded 2 nos. half circle bracket made of GI strip (65 x 8) mm. with two holes on extended portion of the each strip of length min. 250 mm , and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Rate arrived from G.S. Page : G-1/Item-2d)
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. (For Soft soil) (Page : G-1/Item-1a) .
Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36cm X86.36cmX46cm deep(below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside)CI hinged inspection cover of size 36.56cmX35.56cm with locking arrangement ,GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [ 3(a)/G-2 ]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode. [ 3(b)/G-2 ]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. -- 40 mm dia [ 11(c)/F-6 ]
Laying of strip as below, after cutting floor/pavement/wall/ and making holes incl., embedding the strip at an average depth as below and mending good the damages to original finish incl. removing the rubbish at an average depth of 75 mm. in floor/pavement/wall etc. [ 5(i)/F-3 ]
Supply, Laying & Fixing of 50mm x 6mm galvanized (Hot Dip) steel strip in underground trench for interconnection between the Earth Points by joining (As per item no 11). (Rate arrived from G.S. Page : K-3/Item -134 + G-1/Item-1a.)
Cost of Jointing for Horijontal & vertical run of GI strip through welded joint of (25 x 6) mm or (50 x 6) mm GI Strip to Lap joints/ 'T' joints, etc. and painting the joints with 2 (two) coats of bituminous paint. (NS)
PART -- D ( COMPOUND LIGHTS AND FEEDER PILLAR ) SUB HEAD 1 -- DISTRIBUTION WIRING Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ For Run Mtr. ] [ 1(a)/(i)/E-14 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes as per GS. 1.5 Sq mm [ NS ]
SUB HEAD 2 -- SUPPLY OF CABLES Supply & Delivery of 2 Core PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor Cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR ] 2 core 10 Sq mm. cable. [ NS ]
SUB HEAD 3 -- LAYING OF CABLES Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as per GS. -- [ 2(a)/F-1 ] [ For 2 core 10 Sq mm. ]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damagesas per GS. -- From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. [ 5(i)/F-3 ] [ For 2 core 10 Sq mm. ]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry as per GS.2 core 10 Sq mm. cable gland. [ 7(a)/F-4 ]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make) as per GS. 2 core 10 Sq mm. cable [ 8(b)/(iii)/F-5 ]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire as per GS. [ 18/ C-3 ]
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmmPVC/A cable and having lined with rubber gasketted GI top coverwith brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. as per GS. -- [ 5/H-5 ]
S & F of Compound Light Timer Control Box with Double door 10 Way SPNDB enclosure on wall as per -- ( Make - L&T) incl. interconnection with suitable size of PVC insulated copper wire and neutral link & proviosion for earthing attachment. incl. proper socketting with required size of copper lugs and following accessories -- i) 240/415 V, 32 A DP MCB of Breaking Capacity 10 KA & ''C'' Charecteristics ( Make - L&T ) - 1 nos. ii) 25 A, 2 Pole Power Contactor with 220 coil voltage ( Make -L&T, Cat no - MNX - 25 - 2P, ) - 1 nos. iii) Digital Time Switch ( Make - L&T, Cat No - Crono 67DDTO ) -1 nos. iv) One no. Red and One no. Green 240 V LED indicator lamp for indicating purpose of Auto & Bypass indication ( Make -- L&T ) v) Auto/Manuual Toggle Switch -- 1 nos vi) S & F 4 way terminal lead on existing enclosure over the pvc insulated chairs with necy. nuts, bolts & washers. -- 2 nos. [ NS ]
Supply & Delivery of Street light luminaire (IP 66) with peanut lens and high poer LED to ensure uniform distribution and higher spacing between poles, 10 KV SPD, THD<10%, PF> 0.95, BIS approved silicon filled potted driver, minimum LPW : 110 lumen/watt and minimum system output 4950 lumen suitable for use with 230 Volt, 50 Hz. ( Make - Phillips/Crompton/Wipro)
PART -- E ( SITC OF FIRE DETECTION SYSTEM ) SITC of Complete UL/CE Listed CONVENTIONAL MAIN FIRE ALARM PANEL FOR ELEC. BUILD. WITH ALL HARDWARE & SOFTWARE ACCESSORIES & MOUNTING ARRANGEMENT COMPRISING OF FOLLOWING :- A) 4 Zone Panel ( 3W+1S) B) 48 Hours Integral Battery Back-Up with Charger ( 2 X12V) C) Additional Contact ( Min. 2 Nos. Potential Free Contact) , Hardware & Software must be provided in Build MFAP for Interfacing with DCS/SCADA / HVAC / PA SYSTEM D) Zone wise Isolation Facility With Loop Voltage Cut Off. E) Compatibale to All Type of Conventional Detectors. F) Zone Wise Sounder/ Zone Wise Contact. (Make- RAVEL/AGNI)
SITC of Conventional MULTI-SENSOR DETECTOR, Including Mounting arrangement Hardware, JB/GI BACK BOX (as required) and necessary cable gland with end of Line Resistor ( Make -RAVEL/AGNI)
SITC of Conventional MCP/BREAK GLASS UNIT - including Mounting arrangement Hardware, JB/CANOPY ( as required ) with necessary cable gland with end of Line Resistor ( Make -RAVEL/AGNI)
SITC of Conventional HOOTER CUM STROBE , including HOOTER BASE with Mounting arrangement HARDWARE, JB/CANOPY ( as required ) with necessary cable gland and end of Line Resistor ( Make - RAVEL/AGNI)
SITC OF RESPONSE INDICATOR (RI) including Mounting arrangement Hardware
SITC of FRLSH CABLE for LOOP CABLE FOR CONNECTING DEVICES.- including Cable gland, Ferrule, Lugs, Tie, All Tools/Tackles Etc. for Laying of cable ( Make - Polycab/Mescab )
SITC of Conventional HEAT DETECTOR (ROR), including Mounting arrangement HARDWARE , JB/GI BACK BOX ( as required ) and necessary Cable gland with end of Line Resistor ( Make - RAVEL/AGNI)
MOON ELECTRICALS (BID ID -6697554)
M/S R. K. ENTERPRISE (BID ID -6663549)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .