Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC PR CDA SC PUNE 01 THROUGH AO GE DEHU ROAD | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹28.6 L+₹4.1 L (16.9%)Rejected-Finance 27 ABUSETH ROAD DEHU ROAD PUNE 412 101 | NA | NA | 412101 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹28.8 L+₹4.3 L (17.7%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹28.9 L+₹4.4 L (18.1%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹33.5 L+₹9.0 L (36.8%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
12 Oct 2020, 6:00 pmClosed
GE Dehu Road, Pune
GE Dehu Road, Pune
REPAIRS AND CLEANING OF SEWAGE LINE DRAIN ROOF CEILING PLINTH PROTECTION GATE AND FENCING IN CQA SV ALKAPURI EME WKSP UNDER AGE BR EAST GE DEHU ROAD
2020_MES_378524_2
8464/E8
Open Tender
Civil Works
Item Rate
270 days
GE Dehu Road, Pune
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Dehu Road, Pune
₹70,000
Yes
1 Dec 2020
18 Sept 2020
19 Oct 2020
18 Sept 2020
12 Oct 2020
28 Sept 2020
Amount
Dismantling / taking down AC waste/vent pipes fixed to walls with all fittings/ accessories 100 mm dia pipes.
Demolition of brick work built in cement mortar including all arches, pillars all quoins etc complete all as directed.
Demolition of cement concrete (Unreinforced) of any description below or above GL of any description and in any position not otherwise specifically provided for complete all as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean redious built in CM 1:4
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface incl mixing of water proofing compound finished even & smooth with using extra cement. (Note: WPC shall be measured & paid seperately)
M&L for rendering 15mm thick in CM 1:6 other than fair faces of brick work finished even & smooth using extra cement complete all as directed.
Supply only integral water proofing compound.
S&F in repair PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm.
S&F.110 mm dia PVC (SWR) bends, any radius with access door
S&F 110 mm dia PVC (SWR) branch piece (Single Y) equal or unequal.
S&F 110 mm dia PVC (SWR) branch piece double, (Single Y) equal or unequal.
S&F 110 mm dia PVC (SWR) vent cowl
M&L repair for reinforced cement concrete pipes class NP-3, laid in trenches & jointed complete with collars, for the following dias :-
(a) 100 mm internal dia of pipe.
(b) 150 mm internal dia of pipe.
(c) 200 mm internal dia of pipe.
(d) 300 mm internal dia of pipe.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in bed to drain pipes, incl packing under & hauching against the sides of pipes after they are laid and tested for the following dias :-
(a) 100 mm dia RCC pipe.
(b) 150 mm dia RCC pipe.
(c) 200 mm dia RCC pipe.
(d) 300 mm dia RCC pipe.
M&L for cutting into existing manholes for connecting new drains making good to pipe & rendering, cutting. Out existing benching for & forming branch channel in cement concrete 1:2:4 type B-1 smooth finishing & reforming benchin as required for bore of pipe dia :-
(a) Bore of pipe 100 mm .
(b) Bore of pipe 150 mm .
(c) Bore of pipe 200 mm .
(d) Bore of pipe 300 mm .
M&L for 75 mm thick precast Cement concrete 1:2:4 Type B-1 cover slabs set and jointed in CM 1:6 Note:- Reinforcement shall be measured and paid separately.
M&L for mild steel deformed bars 6 to 8mm dia cut to length, bent to shape required incl cranking, bending, hooking ends & binding with & incl mild steel wire (annealed) not less than 0.9 mm dia.
S & F in repair for CI nahani trap/floor trap incl jointing to waste pipe fixed in cement concrete 1:2:4 (Type B-2), 75mm diameter with gratings incl taking down old broken traps.
M&L for PCC 1:2:4 type B-1,(using 20mm graded stone aggregate) as in sunken floor incl water proofing liquid @ 200ml per 50Kg cement. (water proofing liquid to be measured separately) finished even and smooth.
M&L for integral water proofing liquid @ 0.30 ltr per Sqm using water proofing compound for plaster & concrete using pidi proof for LW for sunken portion of toilets in plastering vertical surfaces & concreting at the bottom of sunken floor. Make: Dr Fixit, Pidilite.
M & L for polymer modified bituminous elastomanic water proof coating @ 0.60 Kg per Sqm in two layers for sunken portion of toilet Make: Dr Fixit, Pidilite
M&L rendering 15 mm thick in cm 1:4 in sunken portion on Brick / stone masonery surfaces, incl water proofing liquid @ 200ml per 50Kg cement. ((water proofing liquid to be measured separately) including finished even and smooth.
M&L for PCC 1:5:10, type E-2, (using 40mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
S/F 40 mm dia PVC pipe (out from sunken portion) for spout.
S&F vitreous china squatting pan ORRISA PATTERN size 580x440mm white with integral foot rests excluding flushing cistern & fush pipe fixed in repairs incl "P" or "S" trap.
Supply and fix hume pipe septic tank 50 users capacity including all excavation earth work required and demolition and removal of old septic tank (any size) and removal of debris,including vent pipe,cowl,rcc covers,plasters and connecting the new septic tank to the incoming sewer lines and connected to soak pit as directed.
Ditto- all as per item No. 41 above but 25 users -do-
Dismantling floor hearth or wall tiling incl cement mortar bedding but not backing, complete al as specified.
M&L Non skid ceremic coloured tiles 7 to 8mm thick (square/rectangular)area of each tile exc. 0.06sqm but not exc. 0.11sqm, in floors etc , set and jointed in neat cement sluury and pointed in white or coloured cement to match the coloured tiles including 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes.
M&L for glazed coloured ceramic tiles 300mm x 200mm x6 to 7 mm thick as in vertical surfces set & jointed in neat cement slurry & pointed in coloured cement incl backing coat 10mm thick in CM 1:4 all as direced.
M & L for excavation in trenches n exc 1.5M deep & exc. 1.5M wide and getting out in soft/loose soil
Returning filling in including levelling , watering and well ramming in layers n exc 25 cm thick in soil.
Removal of surplus soil to a distance n exc. 50 M & depositing where directed at a level n exc. 1.5 M above starting point.
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified.
M & L PCC type D2 1:4:8 (40 mm Gr. Agg ) 75mm thick as in sub base complete all as specified.
M&L for laying machine pressed precast concrete interlocking reflective coloured pavers block any shape and size confirming to IS 15658-2006 of 55mm to 60mm thick, M-35 Grade over 30mm thick sand layer watering and ramming all as specified.
M& L Chequared Cement Concrete Tiles 20 CM x 20 CM X 25 mm th set and jointed in cement slurry and pointed in neat grey cement & pigment in floors over screed bed 15 mm thk in cm 1:6 .complete all as specified.
Supply only integral water proofing compound.
M&L for water proofing treatment using polymerised membrane to roof slab including taking down existing treatment of any description and any layer from roof and apply. Water proofing treatment shall be as under :- (a) Rendering 10mm thick in CM 1:4 on concrete surfaces / slabs with admixture of integral water proofing compound @ 3% by weight of cement for filling depressions if any to receive water proofing treatment. (b) The roof surface shall be thoroughly wire brushed, washed, dried up & cleaned to remove all foreign materials & dust to receive primer. (c) On the dried roof surface, apply one coat of bituminous primer @ 100 Gm/ Sqm as per manufacturers instruction. (d) On this primed surface, the approved APP modified bituminous membrane with non woven polyester mat asreinforcement weighing not less than 3.5 Kg/ Sqm laid by torch application metho and top surface shall be applied with bituminous aluminium paint. (e) The overlap while torching shall be 75mm on longitudinal direction & 100mm on transverse direction.
Taking down cement plaster of any description on brick or stone walls/concrete surfaces, including racking out joints, hacking for key, scrubbing down with water etc.
M&L for rendering 10mm thick in cement mortar 1:6 on Brick / conc. surfaces & finishing surface even & smooth with thin layer of sagol finish.
M&L rendering 15mm thick in cm 1:4 on Brick / conc. surfaces or surfaces other than fairface of brickwork with incl admixture of WPC 3% by wt of cement. (WPC to be measured separately) including finished even and fair.
M&L, applying two coats of oil bound distemper over one coat of primer and putty including preparation of newly plastered surfaces of walls complete all as specified and as directed.
M&L for preparation of old decorated surfaces of walls and applying two coats of (apex coating) paint of any shade over a coat of putty (make-Birla or JK white) @ 1.2kg/Sqm of surface area complete all as specified and as directed.
Taking down or up steel water tubing 15 mm dia and connections with all fittings/ valves in any place, wall, roof, ceiling etc and removal to store all as specified.
- ditto - all as per item No. 62 above but 20mm dia.
S&F galvanised iron water tubing medium grade, including all fittings such as tees,bends,elbows, reducers,unions, clamps etc complete fixed to wall or laid in floors for 15 mm bore pipe.
All as per item No 8 above but except material.
S&F galvanised iron water tubing medium grade, including all fittings such as tees,bends,elbows, reducers,unions, clamps etc complete fixed to wall or laid in floors for 20 mm bore pipe.
All as per item No 49 above but except material.
Dismntling PVC water tanks of any capacity and removing to store.
S/F in repair rotational moulded polythene water storage tank cylindrical vertical ) with closed top hoisted & fixed on position of capacity 500 ltr.
M&L for PCC (1:2:4) type B0 using 12.5mm graded stone aggregate lacing coarse at junctions of roof and parpet wall as specified and directed.
Dismanteling fencing wire mesh, any type any dia complete.
Dismanteling post, struts , (wood , steel or Rcc) any section incl. taking out embede portion in concrete or brickwork and making disturbed portion good and all as directed.
Dismanteling MS works of any Description. Not otherwise provided for and all as directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate ) as in foundation concrete for fencing post.
S&F MS Screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length exc. 5 cm but not exc 10 cm long 11 to 15mm dia of shank.
M & L band straps supports to stays flat iron straps to chain link fencing including drilling bolting or riveting etc as directed.
Supply only chain link MS galvanised fencing incl line wire of any size & description and any type of strands, rails, straining bolts etc incle provn of binding wire all complete.
Fixing only chain link fencing any mesh, size and type to any type of standards, rails, straining bolts etc incl provn of binding wire
M&L for round bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and incl MS Wire (annealed) not less than 0.9mm dia or securing with clips.
S&F GI two strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs @ 75mm spacing and straining and fixing to any type of standard rail, straining bolts, inlc securing or tying at crossing with and provn of galvanised mild steel wire staples or steel pins etc. All as specified (Each line of wire to be measured.)
M&L two coats of synthetic enamel paint to new steel surfaces over a coat of red oxide primer surfaces of any description exc 10 cm in witdth or girth complete and all as directed.
All as rev item No 64 above but not exc 10cm in width or girth complete and all as directed.
M&L for mild steel framed work as in doors or gates of angles or other sections with braces etc., complete drilled for fixing of steel sheeting and prepared for hanging with and including hinges, fabricated hasp and staple for locking arrangement and hanging and fixing complete all as specified and as directed.
Star Construction
D J Construction
Preeti Enterprises
DINESH CONSTRUTION
DR J S CHADHA AND SONS
RAMESH PATIL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .