Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.9 CrAccepted-Finance | ₹70.9 Cr | L1 | Accepted-Finance L1 and Most Advantageous Bidder |
| 2 | L2₹74.6 Cr+₹3.7 Cr (5.16%)Rejected-Finance | ₹74.6 Cr+₹3.7 Cr (5.16%) | L2 | Rejected-Finance LETTER OF PRICE BID NOT SUBMITTED AS PER ITB CLAUSE 11.3. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Non-Responsive |
| Sl No | Description | Qty | Unit | BhuganInfraconPvtLtd L1 | Hetvi Construction Limited L2 |
|---|---|---|---|---|---|
| 2.00Schedule-1 Survey, soil investigation, Design, Drawing & Documentation work | |||||
| 3.00 | Topographical Survey, Geotechnical investigation, Design, Drawing & Documentation work for Sewerage and other ancillary works: Work Shall Include Design, Engineering, Preparation of Good for Construction drawing for civil, structural, mechanical electrical & instrumentation and vetting of major RCC structures from reputed Govt. institute (IIT/NIT or approved by Engineer-In-Charge. Pipe line route survey ,Proposed & Existing Components Plot Survey,Household survey (Door to Door Survey), geo-tagging, Trial pits etc. as per Technical specification and as directed by Engineer-In-Charge . | 1 | Lot | 2,00,00,000 ₹2,00,00,000 | 1,50,00,000 ₹1,50,00,000 Lowest |
| 4.00 | Survey, soil investigation, Design, Drawing & Documentation work for STP and its ancillary works:Work Shall Include Survey & soil investigation work, Preparation & submission of Hydraulic/Architectural Design & Drawing, Civil/Structural Design & Drawings, Electrical, Mechanical & Instrumentation Design & Drawings, As Built drawings, Preparing training Programme and Manuals etc complete all as per scope of work and as directed by Engineer-In-Charge . | 1 | Lot | 1,00,00,000 ₹1,00,00,000 Lowest | 1,50,00,000 ₹1,50,00,000 |
| 5.00Schedule -2 Sewer Network Pipe line,House Service Connections,Sewage Pumping Stations and its ancillary works | |||||
| 6.00SEWERAGE WORKS | |||||
| 7.00 | Dismantling steel cylinder R.C. Pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking leadcaulked joints, melting of lead and making two blocks including stacking of pipes & leadat site within 50 meters lead as per direction of Engineer-in-charge.
Upto 600 mm diameter | 10,825 | meter | 500 ₹54,12,500 Lowest | 800 ₹86,60,000 |
| 8.00Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m: All kinds of soil | |||||
| 9.00 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia | 13,137 | meter | 50 ₹6,56,850 Lowest | 120 ₹15,76,440 |
| 10.00 | Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm | 8,375 | meter | 50 ₹4,18,750 Lowest | 120 ₹10,05,000 |
| 11.00Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m: Ordinary rock : | |||||
Tender Value
Refer Docs
EMD Value
₹1.5 Cr
Closing Date
28 Jan 2026, 3:00 pmClosed
Project Director, SICRTD
Uttarakhand Tourism Development Board, (UTDB) Govt. of Uttarakhand Pt. Deen Dayal Upadhyay, Paryatan Bhawan, Near ONGC Helipad, Nimbuwala, Garhi Cantt, Dehradun
Development of Sewerage System, including 5 MLD STP, ancillary works and 5 years of O and M at New Tehri town in Uttarakhand
2025_UTADB_89777_1
905/SICRTD/49/2025-26 dated 05/12/2025
Open Tender
Composite Works
Item Rate
Tehri
As per Bid Document
4 documents required · 4 mandatory
₹11,800
Project Director, SICRTD
₹1.5 Cr
Dehradun
8 Sept 2026
12 Dec 2025
28 Jan 2026
12 Dec 2025
28 Jan 2026
1 Jan 2026
12 Dec 2025 - 24 Dec 2025
23 Dec 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Schedule-1 Survey, soil investigation, Design, Drawing & Documentation work | - | - | - | - |
| 3 | Topographical Survey, Geotechnical investigation, Design, Drawing & Documentation work for Sewerage and other ancillary works: Work Shall Include Design, Engineering, Preparation of Good for Construction drawing for civil, structural, mechanical electrical & instrumentation and vetting of major RCC structures from reputed Govt. institute (IIT/NIT or approved by Engineer-In-Charge. Pipe line route survey ,Proposed & Existing Components Plot Survey,Household survey (Door to Door Survey), geo-tagging, Trial pits etc. as per Technical specification and as directed by Engineer-In-Charge . | 1 | Lot | - | - |
| 4 | Survey, soil investigation, Design, Drawing & Documentation work for STP and its ancillary works:Work Shall Include Survey & soil investigation work, Preparation & submission of Hydraulic/Architectural Design & Drawing, Civil/Structural Design & Drawings, Electrical, Mechanical & Instrumentation Design & Drawings, As Built drawings, Preparing training Programme and Manuals etc complete all as per scope of work and as directed by Engineer-In-Charge . | 1 | Lot | - | - |
| 5 | Schedule -2 Sewer Network Pipe line,House Service Connections,Sewage Pumping Stations and its ancillary works | - | - | - | - |
| 6 | SEWERAGE WORKS | - | - | - | - |
| 7 | Dismantling steel cylinder R.C. Pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking leadcaulked joints, melting of lead and making two blocks including stacking of pipes & leadat site within 50 meters lead as per direction of Engineer-in-charge.
Upto 600 mm diameter | 10,825 | meter | - | - |
| 8 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m:
All kinds of soil | - | - | - | - |
| 9 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia | 13,137 | meter | - | - |
| 10 | Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm | 8,375 | meter | - | - |
| 11 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:
Ordinary rock : | - | - | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Technicalbidpart1.pdf
Tender Documents • 25.69 MB
Addldoc.pdf
Additional Documents • 0.16 MB
Technicalbidpart2.pdf
Tender Documents • 22.57 MB
BOQ_106430.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .