Loading…
Loading…
Tender Value
₹5.9 Cr
EMD Value
₹5.9 L
Closing Date
5 Jun 2026, 6:00 pmClosed
Executive Engineer, R and B Division, Himatnagar
Construction of New Kanya Chhatralaya (S.T.) at Netramali, Taluka-Idar, Dist. Sabarkantha
301330
01 of 2026-27
Open
Civil Works - Buildings
Works
Sabarkantha
7 documents required · 7 mandatory
₹12,000
Executive Engineer, R and B Division, Himatnagar
₹5.9 L
4 May 2026
4 May 2026
4 May 2026
5 Jun 2026
4 May 2026
Name of work :- Construction of New Kanya Chhatralaya
(S.T.) at Netramali, Taluka-Idar, Dist.
Bill of Quantities
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
1 Excavation for foundation upto 1.5 m depth including sorting 1514.00 Cum 157.08
out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(B) Dense or Hard soil
2 Excavation for foundation for depth from 1.5 m to 3.0 m 584.00 Cum 287.47
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(C)
3 Filling available excavated earth (excluding rock) in 2187.00 Cum 136.92
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each disposited
layer by ramming and watering.
4 Filling in plinth with sand under floors including watering 98.00 Cum 481.81
ramming, consolidating and dressing complete
5 Filling in foundation and plinth with murrum or selected soil 492.00 Cum 294.39
in layers of 20cm. thickness including watering, ramming
and consolidating etc. complete.
6 Providing and laying controlled cement concrete M.150 for 266.00 Cum 4201.60
curing complete including cost of formwork but excluding
the cost of reinforcement for reinforced concrete work in (A)
Foundations, footings,Base of columns and Mass concrete
7 Providing and laying controlled cement concrete M.250 and 299.00 Cum 4519.75
curing complete including cost of formwork but excluding
the cost of reinforcement for reinforced concrete work in (A)
Foundations, footings, Base of columns and Mass concrete.
8 Providing and laying controlled cement concrete M250 and 28.00 Cum 6952.84
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts Column Up to
9 Providing and laying cement concrete 1:4:8 (1- Cement : 4- 24.00 Cum 3374.11
coarse sand : 8- Machine Crushed stone aggregates 40 mm
nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
10 Providing and laying controlled cement concrete M.250 and 73.00 Cum 6002.43
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work for Ground and Plinth Beams
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
11 Brick work using common burnt clay building bricks having 118.00 Cum 4214.33
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)
12 Providing and laying controlled cement concrete M.200 and 102.00 Cum 7865.52
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Columns, Pillars posts and struts, For All Floors.
13 Providing and laying controlled cement concrete M.200 and 106.00 Cum 7963.49
curing complete including the cost of formwork (Vertical
fins and vertical sun breakers.) and reinforcement for
reinforced concrete work in (B) Walls, for all floor level
14 Providing and laying controlled cement concrete M.200 and 216.00 Cum 6136.23
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Beams For All Floors.
15 Providing and laying controlled cement concrete M.200 and 390.60 Cum 6441.40
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Slab for All Floors.
16 Providing and laying controlled cement concrete M.200 and 36.00 Cum 6454.21
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Lintels For All Floors.
17 Providing and laying controlled cement concrete M.200 and 11.00 Cum 6989.40
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Chajja For All Floors.
18 Providing and laying controlled cement concrete M.200 and 22.00 Cum 6905.88
curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work in (E) Staircases
19 Providing TMT Bar FE 500D reinforcement for R.C.C. work 171708.00 Kg. 77.29
including bending, binding and placing in position complete
20 Providing throating or plaster drip and moulding to R.C.C. 218.00 Rmt 43.08
Chhajja by making 5mm to 15mm wide grove as per design
21 Brick work using Common Burnt Clay building bricks 582.00 Cum 4538.60
having crushing strength not less than 35 kg./Sq.Cm. in
Super structure Above plinth level up to All Floor levels in
Cement Mortar 1:6 (1- Cement : 6 -fine sand) (Conventional)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
22 Half brick masonry in common burnt clay building bricks 612.00 Sqmt 691.76
having crushing strength not less than 35 Kg/Sq.Cm. in
Superstructure above plinth level upto All Floor level in
Cement mortar 1:4 (1- Cement : 4 -coarse sand )
(Conventional).
23 Providing & Fixing Chicken mesh for joint between brick 331.00 Sqmt 173.72
work & RCC work fixing with nail & GI washer as per
director in charge
24 Providing 15mm thick cement mala plaster in single coat on 4678.00 Sqmt 269.96
Rough (Similar)side of single or half brick walls for interior
plastering and finished even and smooth fininshing with a
floating coat of neat cement slurry in (i) Cement mortar 1:3
(1-cement:3-sand), 10x10 mm groves etc. Complete for All
25 Providing 10mm thick cement mala plaster in single coat on 3666.00 Sqmt 241.32
brick/concrete walls for interior plastering and finished even
and smooth fininshing with a floating coat of neat cement
slurry in (i)Cement mortar 1:3 (1-cement:3-sand). Complete
for All Floors.
26 20mm thick sand faced cement plaster with Gutka Finish on 1848.00 Sqmt 321.10
walls upto height 15 metres above ground level consisting of
12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand)
and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-
sand) with 5mm grooves, etc. complete.
27 Providing Water Proofing Treatment on Sunk Slab including 183.00 Sqmt 370.67
cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-
graded stone aggregate 20mm nominal size) laid in one layer
and finished with a floating coat of neat cement average
50mm thick to prepare slope including water proofing
chemical etc. Complete for Sunk Slab for All Floor.
28 Applying two coats of putty & two coats of primer of 7872.00 Sqmt 40.59
approved brand and manufacture on new wall surface to give
an even shade including thoroughly brushing the surface free
from mortar dropping and other foreign matter and sand
papered smooth.
29 Wall painting (three coats) with plastic emulsion paint of 4260.00 Sqmt 125.52
approved brand and manufacture on undecorated wall
surface to give an even shade including throughly brushing
the surface free from mortar droppings and other foreign
matter and sand papered smooth.
30 Ceiling painting (three coats) with plastic emulsion paint of 3659.00 Sqmt 131.02
approved brand and manufacture on ceiling and soffits of
slab surface to give an even shade including throughly
brushing the surface free from mortar droppings and other
foreign matter and sand papered smooth.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
31 Finishing wall with weather proof exterior emulsion paint 2213.00 Sqmt 93.93
(two coats) with Damp Proof Coating (one coat) on wall
surface to give an required shape even shade after
thoroughly brushing the surface to remove all dirt, and
remains of loose powdered materials.etc complete
32 Providing and laying polished Kota stone slab flooring over 1587.00 Sqmt 1019.00
20mm (Average) thick base of cement mortar 1:6 (1-cement :
6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse
sand) laid over and jointed with grey cement slurry mixed
with pigment to match the shade of slab including rubbing
and polishing etc. complete. (A) 25mm thick
33 Providing and laying polished kota stone slab 25mm thick in 105.00 Sqmt 1166.93
risers of steps,skirting Dedo and pillars laid on 10mm thick
cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed
with gray cement slury mixed with pigment to match the
shade of slab including rubbing and polishing etc. complete.
34 Providing and fixing pre-cast Rubber Dye / steel Dye inter 1096.00 Sqmt 706.93
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as
per approved design Confirming to IS 15658 :
including 35 mm Sand layer for levelling and filling the joint
with sand in proper line and level as per guidlines of IRC :
SP 63-2018 etc. Complete.
35 Providing and fixing Machine cut & Polished kota stone in 50.00 Sqmt 1355.42
7.5 cm width Strip flooring for Ramp even grade over 20mm
(Average) thick base of cement mortar 1:6 (1-cement : 6-
coarse sand) laid over and jointed with grey cement slurry
mixed with pigment to match the shade of slab including
rubbing and polishing etc. complete. (A) 25mm thick
36 P & L 24" x 24" Ceramic 10 mm thick tile flooring over 20 246.00 Sqmt 1266.54
mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse
sand) on new surface or fixing on existing flooring by
adhesive material including dismentaling of existing flooring
and jointed with color cement slurry including finised with
flush pointing & cleaning the surface etc. complete for
37 Providing and laying coloured glazed tiles of the size 300 1196.00 Sqmt 1487.88
mm x 450 mm x 8 mm in skirting, risers of steps and dedo
on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse
sand) & jointed with white cement slurry.
38 Providing and laying Ceramic tiles 6mm thick in skrting 14.00 Sqmt 1090.32
risers of steps and dedo on 10mm thick cement plaster 1:3 (1-
cement : 3-coarse sand) and jointed with white cement slurry
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
39 Providing and fixing Machine cut, Free edges, Mirror 93.00 Sqmt 2464.40
Polished Granite stone slab flooring 18mm thick laid on
20mm (Average) thick base of cement mortar 1:6 (1-cement :
6-coarse sand) for Trade & Riser including Half Round
moulding front edge of trade jointed with grey cement slurry
mixed with pigment to match the shade of slab including
rubbing and polishing etc. complete.
40 Providing and fixing Machine cut, Free edges, Polished 438.00 Sqmt 2510.86
Green Granite stone slab flooring 18mm thick for vertical
wall/Doors/Windows Sill, Jams for cladding as per design
including full moulded round inside edge and laid on10mm
thick base of cement mortar 1:3 (1-cement : 3-coarse sand)
jointed with grey cement slurry mixed with pigment to match
the shade of slab including rubbing and polishing etc.
41 Providing and laying water prooofing treatment with china 728.00 Sqmt 1132.21
mosaic tiles flooring over avg 50 mm C.C. 1:2:4 bedding
maintaining slope for plain and curve surface & 12 mm to
mm broken pieces not more than 2.5 cm of ceramic/ of
glazed tiles to be laid over cement mortar 1:3 to plain or
slope and to be tempered to bring mortar creme out upto
surface using white cement including rounding off junctions
and extending them upto 15 cm along the wall,clearing with
water and oxalic acid etc. as directed.
42 Constructing Sandwich Platform of 18mm thick polished 50.00 Sqmt 2760.33
black or selected granite at top and 25 mm thick kota stone
with 75cm height with necessary support using 20mm thick
cement mortar 1:3 for sandwich and fitting at bottom &
edges with waterproof rigid adhesive including making
necessary grooves in walls with vertical support of double
kota stonr sandwich every 60cm centre to centre including all
labour material of approved quality including full moulded
round front edge fixed in wall for partition.
43 Providing and fixing flush door with Single shutters, solid 155.00 Sqmt 4129.89
core construction with frame of first class hardwood with
cross board and finished with 1 mm thick laminate on both
side of shutter, machine glued PVC beading on periphery
including 30cm long Stainless Steel Pipe handle on both side
SS ASIS 304 grade, SS Stopper 20cm, SS Aldrop 30cm both
side, anodised alluminium butt hinges with necessary screws.
(B) Non-decorative type and block board core anodised
alluminium butt hinges in flush door shutters (2) 35 mm
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
44 Providing and fixing flush door with Double shutters, solid 12.00 Sqmt 5279.27
core construction with frame of first class hardwood with
cross board and finished with 1 mm thick laminate on both
side of shutter, machine glued PVC beading on periphery,
including 30cm long Stainless Steel Pipe handle on both side
SS ASIS 304 grade, heavy duty Floor Spring each side, SS
Stopper 20cm, SS Aldrop 30cm both side, anodised
alluminium butt hinges with necessary screws. (B) Non-
decorative type and block board core anodised alluminium
butt hinges in flush door shutters (2) 35 mm thick.
45 Providing and fixing window having extruded aluminum 144.00 Sqmt 1738.21
Colour anodized section frame main outer size 95mm x
24mm x 1.17mm @ wt.of 0.738 Kg/mt , horizontal Three
track member size 92mm x 31.75mm x 1.30mm,@ Wt.1.07
Kg/mt , vertical member of size 92mm x 31.75mm x
1.50mm @ Wt. 1.06 Kg/mt with sliding shutters of
horizontal member size 40 mmx18mm x1.29mm @ wt.of
0.456 Kg/mt, vertical member of size 40mm x 18mm x
mm @ wt.of 0.456Kg/mt/ with 5 mm thick transparent
bronze colour tinted float glass with rubber gasket and
airlock strip anodiazed aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per details
etc. With Mosquito net shutter in outer track.
46 Providing and fixing standared extruded of alluminium 16.00 Sqmt 2131.10
section of size 63.50 x 38.10 x 1.95 mm,@ Wt 1.094Kg /
Rmt with colour anodized alluminium frame with 5 mm
thick transparent bronze colour tinted float glass as details
etc complete for Fix window with Mosquito net.
47 Providing and fixing Louvers in G.I Channel 40x32x5mm 101.00 Sqmt 2215.94
size And 114mm Wide G.I Sheet Having Thickness of
0.55mm & Weight Not Less Than 490 Gm/Mtr. Roll Formed
to create 84mm wide Louver snap fixed on special shaped
G.I Channel,Channel shall be Finished with Powder Coating
of 55 micron For Fix Louvers As Directed By Engineer In
48 SIGNAGES ON DOOR :Providing and fixing 304 grade 42.00 Nos. 1262.50
stainless steel 1.5mm thick brushed steel finish plate fixed on
a door using S.S studs and with punched (laser cut) lettering
carried out on S.S plate of required size and text as directed
by engineer etc. complete. Size 30 cm x 15 cm
49 Providing erecting and fixing double coated ISI water tank of 20000.00 Litre 3.95
required capacity each with all necessary fittings and
connection etc. complete on terrace
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
50 Providing, laying and jointing in true line and level 110 472.00 Rmt 876.11
diameter U.P.V.C (Type B) conforming to IS 13592-1992
with one end plain and other end socketed with rubber ring,
& fittings conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using
of PVC clamp of the size 110 mm diametre x 149 mm length
x 145 mm heigh at every 2000 mm center to center or shall
be concealed in walls as directed including necessary fittings
such as bends, shoes etc. including testing of pipes and joints
and jointed with adhesive solvent cement including cost of
51 Providing, laying and jointing in true line and level 160 408.00 Rmt 834.38
diameter U.P.V.C (Type B) conforming to IS 13592-1992
with one end plain and other end socketed with rubber ring,
& fittings conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using
of PVC clamp of the size 160 mm diametre x 210 mm length
x 196 mm heigh at every 2000 mm center to center or shall
be concealed in walls as directed including necessary fittings
such as bends, shoes etc. including testing of pipes and joints
and jointed with adhesive solvent cement including cost of
52 Providing laying and jointing in true line and level 50mm 86.00 Rmt 195.67
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing the
same with adhesive solvent, including cost of all materials.
53 Providing laying and jointing in true line and level 25mm 655.00 Rmt 91.84
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing the
same with adhesive solvent, including cost of all materials.
54 Providing laying and jointing in true line and level 15mm 350.00 Rmt 72.65
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing the
same with adhesive solvent, including cost of all materials.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
55 Providing and fixing concealed center point to wall ceiling & 105.00 Rmt 253.82
floor CPVC (SDR 13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water of following dia.
nominal bore tube fittings and clamps including making
good the wall, ceiling and floor etc. complete. 25 mm.
56 Providing and fixing concealed center point to wall ceiling & 150.00 Rmt 170.36
floor CPVC (SDR 13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water of following dia.
nominal bore tube fittings and clamps including making
good the wall, ceiling and floor etc. complete. 15 mm.
57 Providing and fixing Gun metal check or non-return fullway 17.00 Nos. 420.63
wheel valve.(C) 25mm dia.
58 Providing and fixing ball cock of approved. quality as 2.00 Nos. 189.84
directed.(A) Copper Metal (ii) 50mm dia.
59 Providing and fixing C.P. brass shower rose with 15mm or 40.00 Nos. 282.16
20mm inlet.(A) 100mm dia. Each
60 Providing and fixing wash down water closet (Wall Hung 23.00 Nos. 5172.51
type, W.C. Pan) with integral P or S trap, Health Fauset
Heavy Duty with hook and PVC dual flush tank with
complete fittings including jointing the trap with soil pipe in
Cement Mortar 1:1 (1-Cement : 1-fine sand) (Seal and cover
to be measured and paid for separately)(A) vitreous China
Pattern :(i) in white colour
61 Providing and fixing washbasin (ii) Flat Back washbasin 550 15.00 Nos. 2180.72
mm x v 400mm size. (i) In white colour including with
approved sanitary grade material with CP waste coupling,
waste pipe, 15mm dia Pillar & Stop Cock of approved brand
with connection 15mm dia flexiable pvc pipe etc. complete
62 Providing and fixing Kitchen sink with C.I. or M.S. brackets, 2.00 Nos. 2987.87
painted white including cutting holes in walls (C) Vitreous
China Sink.(i) 600mm x 450mm x 150mm size including
approved sanitary grade material with CP waste coupling,
waste pipe, 15mm dia Pillar & Stop Cock of approved brand
with connection 15mm dia flexiable pvc pipe etc. complete
63 Providing and fixing screw down bib taps of following 85.00 Nos. 186.83
size.(A) Brass screw down bib tap polished bright. (i) 15mm
64 Providing and fixing PVC SWR Nahni trap IS 14735 for 51.00 Nos. 586.60
drain - 100 mm diameter with jali of the following nominal
diameter of self cleansing design with C.I scread down or
hinged grating including the cost of cutting and making good
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
65 Providing and fixing S.W. gully trap with C.I. grating brick 40.00 Nos. 1246.92
masonry chamber and water tight C.I. cover with frame of
300mm x 300mm size (inside) with standard weight.(i)
Square mouth traps.(B) 150mm x 100mm size P or R type
66 Providing and fixing C.P. brass towel rail comlete with C.P. 29.00 Nos. 616.42
brass brackets fixed to wooden plugs with C.P. brass
scews.(B) 600mm x 20mm size.
67 Providing and fixing 600mm x 450mm bevelled edge mirror 12.00 Nos. 859.41
of superior glass mounted on 6mm thick A.C. sheet or
plywood sheet and fixing to wooden pluge with C.P. brass
screws and washers.
68 Providing and fixing in position PVC cowel went to pipes 12.00 Nos. 75.75
69 Constructing brick masonry chamber for underground C.I. 20.00 Nos. 3660.76
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total
weight of cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe
with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete 1:5:10 inside
plaster 15mm thick with cement mortar 1:3 finished smooth
with a floating coat of neat cement on walls and bed concrete
etc. complete.(ii) Inside dimensions 500mm x 700 mm and
450mm deep for pipe line with one or two inlets.
70 Providing and laying (to level or slopes) and jointing with 6.00 Rmt 531.18
stiff mixture of Cement Mortar in proportion 1:1 Salt glazed
stoneware pipes including testing of pipes and joints
complete and Providing and laying Cement concrete 1:5:10
(1-Cement : 5-Fine sand :10-Graded stone aggregate 40mm
nominal size) bedding for stoneware pipes of following
internal diameters with necessary formwork and curing
complete.(B) 150mm dia.
71 Providing and laying (to level or slopes) and jointing with 6.00 Rmt 352.73
stiff mixture of Cement Mortar in proportion 1:1 Salt glazed
stoneware pipes including testing of pipes and joints
complete and Providing and laying Cement concrete 1:5:10
(1-Cement : 5-Fine sand :10-Graded stone aggregate 40mm
nominal size) bedding for stoneware pipes of following
internal diameters with necessary formwork and curing
complete.(A) 100mm dia.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
72 Applying general insecticide pest control treatment to floors, 819.00 Sqmt 80.62
cupboards etc including labour materials etc. complete.
Using Imidacloprid 30.5 SCas Per IS 6313 part -II( (0.075%
concentration by mass) is recommended 10.5ml chemical
diluted with 5 liters of water application 0.5 litre chemical
/Sqm of surface is recommended as per I.S.
73 Providing and fixing Safety Grills of required pattern for 4765.00 Kg 110.60
windows/door using MS polished bars, Rectangular CRS
Pipes of size 50mm x 30mm x 2mm or Required at required
spacing as per design and hold fast with coach bolts
including one coat of and two coats of matt finished oil
painting etc. complete
74 Providing and fixing a set of wall mounted 38mm dia. U 1.00 Nos. 2323.00
shaped horizontal stainless steel collapsible grab bar, 38mm
vertical stainless steel fixed grab rail of grade SS 304 from
round pipe supported and 75mm dia 8mm thick SS 304 base
flange on wall including anchor fastners, nuts, accessories as
per detailed drawing etc. complete as directed by architect or
engineer in charge.
75 Providing and fixing of conspectus tape 50mm width on of 160.00 Rmt 1923.04
treads in staircase including cutting pasting etc. As per
harmonised guidelines complete in all respect to the entire
satisfaction of engineer in charge.
76 Providing and fixing 90 cm high Stainless Steel railing made 91.00 Rmt 3760.33
from anticorrosive 304 grade S.S. pipe of 50 mm dia. (16
gauge) as hand rail with S.S.304 grade baluster of 32 mm dia
(16 gauge) as a vertical support fixed in RCC Slab/ steps of
stair at 1.2 mt. c/c including three horizontal S.S. pipes of
mm dia (16 gauge) at equal distance fixed by 16 mm dia (16
gauge) S.S. pipe with baluster including accessories as per
detailed drawing as directwed etc. complete
77 Providing and Fixing 8mm thick poly- Carbonate fiber sheet 14.00 Sqmt 2940.82
using sealant water proofing rubberished adhesive oil painted
50x50mm hollow channel for framing of shade as require
and fixing frame with surrounding wall etc. completed as
78 Steel work, welded in built up sections framed work 114.00 Quintal 9108.48
including cutting, hoisting, fixing in position and applying a
priming coat of red lead paint. (A)In beams and joists,
channels angles Tees, flats, with connecting plates or angle
cleats as in main and cross beams. Hip and jack rafters,
purlins conneted to common rafters and the like
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
79 Painting two coats (excluding priming coat) on external 130.00 Sqmt 22.75
surface of new rain water, soil, waste and vent pipes and
fittings with ready mixed bituminous brushing, black,
anticorrosive to give an even shade including cleaning of
all dirt, dust and other foreign matter. (B) 75mm dia.
80 Excavation for foundation upto 1.5 m depth including sorting 185.00 Cum 268.21
out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(C) Hard Murrum
81 Excavation for foundation for depth from 1.5 m to 3.0 m 65.00 Cum 136.92
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil
82 Providing, laying, spreading and compacting stone 78.00 Cum 1820.79
aggregates of specific sizes to water bound macadam (Grade-
II) (B.T. Metal of size 45 to 63 mm) specification including
spreading in uniform thickness, hand packing, rolling with
wheeled steel/ vibratory roller in stages to proper grade and
camber, applying and brooming requisite type of screening/
binding Materials to fill up the interstices of coarse
aggregate, watering and compacting to the required density.
83 Providing and Casting in situ controlled Cement Concrete M- 601.00 Cum 4553.38
200 for R.C.C. Raft and cutt-off walls including necessary
shuttering laying, vibrating, ramming and curing complete.
84 Clearing and grubbing road land including uprooting rank 1.00 Hectare 28455.10
vegetation grass bushes, shrubs, sapling and trees girth up to
300 mm removal of stumps of trees cut earlier and disposal
of unserviceable materials (C) By mechanical means in area
of light jungle
85 Earthwork in cutting including preparing the slope and 82.00 Cum 500.05
camber and stacking or utilising the cutting stuff in bank as
directed upto 200 Meters from the end of cutting with all
lead and lift.(i) Hard murrum.
86 Providing and laying controlled cement concrete M.150 and 12.00 Cum 7426.53
curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work for Coping
87 Providing & laying weep hole in Aburtments, and returns by 340.00 Each 86.73
using A.C. pipe of 100mm including laying in proper grede
and jointing the completed as per detailed specification.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
88 Providing and fixing concertina coil fencing with punched 170.00 Rmt. 565.60
tape concertina coil 600 mm dia 10 mt openable length
having 50 no rounds per 6 mt length, upto 3mt height of wall
with existing angle iron (50mm x50mm x5mm )requird
shaped As per Directed Engeenier in charge. placed 2.4mt or
3.00mt apart and with 4 horizontal R.B.T. reinforced barbed
wire(3 mm) , stud tied with G.I. staples and G.I. clips to
retain horizontal, including necessary bolts or G.I.barbed
wire tied to angle iron, all complete as per direction of
Engineer-in-charge, with reinforced barbed tape
(R.B.T.)/Spring core (2.5 mm thick) and weight
gm/meter at compound wall for ESR M4/intakewell.
89 Steel work, welded in built up sections framed work 21.00 Quintal 9108.49
including cutting, hoisting, fixing in position and applying a
priming coat of red lead paint. (A)In beams and joists,
channels angles Tees, flats, with connecting plates or angle
cleats as in main and cross beams. Hip and jack rafters,
purlins conneted to common rafters and the like
90 Drilling of pilot bore hole of size 250/300 mm diameter at 250.00 Rmt 1544.29
above site by mud finish direct rotary rig etc. complete
91 Reaming of 250/300 mm diameter pilot bore hole to size 450 200.00 Rmt 742.35
mm diameter including assembling, lowering housing, casing
strainer pipes with gravel packing and clay ball packing etc.
92 Providing 600 CFM / 150 PSI capacity air compressor upto 1.00 Job 25118.70
available of sand free discharge ( Minimum 6.0 Hours)
93 Supply of reducer made frim 6 mm thick plate (M.S.) for 1.00 Nos. 2009.90
ERW pipe of size (ii) 200 mm dia. x 250 mm dia. X 600 mm
94 Supply of 200 mm diameter V-wire screen pipe of slot size 65.00 Rmt 1401.88
1.0 mm nominal hole etc. complete.
95 Supply of M.S. Bore clamps with 3 holes on either side with 1.00 Pair 1753.36
nuts and bolts of standard make and suitable size (g) 750 mm
x 75 mm x 16 mm flat to 200 mm dia. Pipe.
96 Supply of Bore Plug having 100 mm height made from M.S. 1.00 Nos. 834.26
plate with 3 holes at equal distance on circumference for nuts-
bolts type, locking arrangement with nut-bolts & lock nuts of
standard make complete. (b) from 5 mm thick M.S. plate (for
top also) (ii) suitable for 200 mm dia. pipe.
97 Supply of M.S. Bail Plug having length of 0.45 mtr from 1.00 Nos. 907.99
medium class pipe as per I.S.S. suitable for (b) 200 mm
diameter pipe etc. complete.
98 Supply of Steel Bent plates suitable to ERW pipe for (b) 200 8.00 Nos. 71.71
mm diameter and 150 x 150 x 6 mm size etc. complete.
99 Supply of Gravel of size selected size up to 4mm to 6 mm, 12.00 Cmt 2295.73
including stacking and filing etc. complete.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
100 Charges for uptron make Electrologger (with carting ) of 1.00 Job 12120.00
pilot bore hole etc. complete.
101 Charges for Geo Hydrological ground water investigation 5.00 Job 16160.00
including water sample chemical analysis etc. complete.
102 S.I.T.C. submersible pump set suitable for bore of 150 mm 1.00 Each 49148.62
dia or more having 3 phase motor capacity not less than
HP with following capacity. Lifting and Lowering taken
extra. [C] 25 stage 160 to 100 LPM discharge at 185 to
mtr head for 50 mm dia delivery pipe
103 Providing and erecting PVC corrugated Flexible conduit with 175.00 Rmt 26.26
required numbers of coupling, PVC bushes, Check-nuts etc.
complete of following sizes. (3) 32 mm diameter
104 Lowering of submersible motor pump set complete with 1.00 Job 2568.43
required. Nos. and size of casing pipes erected by means of
proper chain pulley block & pipe wrenches after checking of
threads of each pipe with coupling to take the load of the
pump set and pipe assembly filled up with water. (B) Above
60 mtr and up to 120 mtr
105 Supplying and erecting approved make motor control cubical 1.00 Each 8710.24
panel (Direct - on - line) made from 16 G. CRCA sheet duly
epoxy powder painted inside and outside with hinged doors
and locking, arrangement consisting of suitable size of ON-
OFF isolator (AC - 3/23 duty) main fuses, single phasing
preventer, indicating lamps for R-Y-B phases, overload
relay, automatic water level controller, Ammeter, Voltmeter
each with two way selector switch incoming, wires duly
socket crimped, main contactor & overload relay, start-stop
push buttons, to be erected on angle iron frame grouted on
wall as directed. The isolator, overload relay & contactors
will be of L&T, Seimens or BCH make only (a) DOL upto
106 Supplying and erecting XLPE (IS:7098) (I)-88 ISI 200.00 Rmt 136.35
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size. (E) 3 core 2.5 Sq. mm
107 Providing laying and jointing in true line and level 50mm 150.00 Rmt 195.67
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing the
same with adhesive solvent, including cost of all materials.
108 Providing and fixing butterfly valve of IS approved brand 2.00 Nos. 1595.80
109 Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. 1.00 Nos 958.17
size having weight not less than 35Kg.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
110 Providing and filling in foundation with ordinary Cement 27.00 Cum 3345.59
concrete M-100 mix and providing necessary vertical pin
headers including formwork, vibrating, ramming and curing
111 Earthwork for embankment including breaking clods, 2356.00 Cum 131.93
dressing with all lead and lift (including watering and
consolidation)(A) From Borrow pits within land width
112 Rolling and consolidation of soling including filling in 2073.00 Sqmt. 22.75
depression which occur during the process, with power roler
8 tonne to 12 tonne..
113 Box cutting the road surface to proper slope and camber for 272.00 Cum 109.05
making a base for road work including removing the
excavated stuff and depositing on the road side slope as
directed upto 50Mt.lead.
114 Construction of B.I.T.C. granular sub base by providing 109.00 Cum 1380.96
granular material of Grading II, spreading in uniform layers
with motor grader on prepared surface , mixing by mix in
place method with front end loader at OMC , and compacting
with vibratory roller to achieve the desired density ,complete
115 Compaction and finishing of cement concrete road by trimix 464.00 Sqmt. 72.72
process providing extra labour charges for the trimix vaccum
dewatering service process on cement concrete road surface
by using vaccum dewatering pump floater surface vibrator
including making rough finish to surface as per in including
levelling the complete.
116 Supplying and fixing reinforced concrete heavy duty non- 40.00 Rmt. 660.00
pressure pipes with collars for culverts carrying heavy traffic
as per IS 458-1991 specifications including setting the pipes
in C.M. 1:2 watering and laying (to level or slopes) of class
NP3 of following internal daimeters.(i) 300mm dia.
117 Construction of Cattle trap made from ISMC 100 border and 8.00 Sqmt. 6146.86
G.I. pipe 50 mm dia. Heavy duty at 12cm spacing by welding
and for supports 2 nos. I.S.M.C. 100x75x6 section fixing in
prepared chamber as per drawing.
118 Constructing Brick masonry road gully chamber 500mm x 16.00 Nos. 2017.20
450mm x 600mm including 500mm x 450mm C.I. horizontal
grating wih frame complete.
119 Supplying of yellow or Goradu soil with all lead and lift 138.00 Cum 505.00
including spreading watering dressing and rolling with hand
roller etc complete selected soil
120 Supplying of well rotted FYM manure with all lead and lift 7.00 Cum 378.75
including spreading mixing dressing and rolling with hand
roller etc. complete
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
121 Scarifying the surface of soil including spreading of DAP 459.00 Sqmt. 26.26
fertilizer mixing with soil properly leveling ground dressing
122 Supplying and planting Dibbling semi carpet lawn at distance 328.00 Sqmt. 90.90
of about 15 cm x 15 cm after proper anti termite treatment
and rolling the same by hand roller and watering etc complete
123 Bowling and developing flowering plants grown in nursery 15.00 Nos. 505.00
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Bottom Palm
124 Bowling and developing flowering plants grown in nursery 15.00 Nos. 656.50
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Triangle Palm
125 Bowling and developing flowering plants grown in nursery 15.00 Nos. 80.80
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Jasud
126 Bowling and developing flowering plants grown in nursery 15.00 Nos. 85.85
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Croton
127 Bowling and developing flowering plants grown in nursery 20.00 Nos. 85.85
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Croton
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
128 Bowling and developing flowering plants grown in nursery 20.00 Nos. 70.70
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Croton Petra
129 Bowling and developing flowering plants grown in nursery 20.00 Nos. 40.40
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Croton Petra Live Plant
130 Bowling and developing flowering plants grown in nursery 20.00 Nos. 101.00
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Golden Durenta Varigated
131 Bowling and developing flowering plants grown in nursery 20.00 Nos. 85.85
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Crotons Variety
132 Bowling and developing flowering plants grown in nursery 250.00 Nos. 35.35
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Green Mahindi
133 Bowling and developing flowering plants grown in nursery 20.00 Nos. 85.85
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Varigated Ficus
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
134 Bowling and developing flowering plants grown in nursery 20.00 Nos. 70.70
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted New Black Ficus
135 Bowling and developing flowering plants grown in nursery 250.00 Nos. 45.45
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted White Ribbon Plants
136 Bowling and developing flowering plants grown in nursery 250.00 Nos. 60.60
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Green Mahendi border
137 Bowling and developing flowering plants grown in nursery 15.00 Nos. 95.95
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Pendulla Asopalav
138 Bowling and developing flowering plants grown in nursery 15.00 Nos. 121.20
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Potted Plants
139 Labour charges for planting various plantsafler proper anti- 980.00 Nos. 70.70
termite treatment in pits including placing properly and
filling the pits with required prepared mix soil and watering
and dispporting etc. complete
140 Maintance of the garden for 60 days after Complition of 3 1.00 Job 25250.00
month stipulated period is completed for plantation of lawn
and plants including applying second round of proper anti-
termite treatment
141 Rubber Hose Pipe 15 mm dia of approved brand and make 75.00 Rmt 90.90
142 Providing and fixing G.I. Nipple as directed 5.00 Nos. 50.50
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
143 Providing laying and jointing in true line and level 40mm 60.00 Rmt 148.12
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing the
same with adhesive solvent, including cost of all materials.
144 Providing and fixing brass screw down stop tap.(A) 15mm 3.00 Nos. 205.83
145 Providing & Laying Rain Water Junction Chamber of Clear 10.00 Nos. 6241.80
Internal Size 0.60 x 0.60 x 0.75m with excavation of size
1.36 x 1.36m & 0.15m thick M200 Bed Concrete Including
brick masonary 0.23 thick wall in C.M. 1:6 of 0.75m height
with 15mm thick Cement Plaster inside & outside (1:4),
x 1.06 RCC M200 top slab of thickness 0.15m with TMT
steel and 455mm x 610mm cast iron manhole cover with
frame weight not less than 35 kg as per directed by Engineer-
146 Providing & Laying Filter chamber of brickwork 0.23 thick 10.00 Nos. 22067.49
in C.M. 1:6 of clear internal size 2.04m x 1.20m x 1.20m and
excavation dimension of 2.80m x 1.96m x 1.35m including
C.C. M200 Bed Concrete 0.15m thick and RCC M200 Top
slab of thickness 0.15m with TMT steel, Including 15mm
(1:4) thick cement plaster inside & outside with Cement
slurry & top cover with frame of minimum weight of 35kg,
including filling filter material of 200mm thick each layer of
25-40mm, 10-20mm of BT metal and sand as per directed by
engineer-in-charge
147 Providing & Laying Water Harvesting Pit of clear size 2.00 1.00 Nos. 32558.36
mt x 2.00 mt x 4.00 mt. For water logging with excavation in
any strata upto four meter depth, Brick work 0.23 thick in
C.M. 1:6 of clear internal size 2.00m x 2.00m x 1.20m with
15mm thick C.M. 1:4 plaster, filling the pit with B.T. metal
40mm in 0.60 mt. depth with 25-40mm kaptchi, 0.30 mt.
depth and 2mt. depth with coarse sand in layers including
makng P.V.C. line for water inlet etc. as directed with
250mm dia bore 15mt. depth amd 150mm dia PVC pipe of
10 Kg.f/cm2 casing wih gravel packing or as directed.
148 A Pump Room. Supply & fixing Diesel engine driven min. 1.00 Nos. 555500.00
pump of S5 mt. head and 137 M3/ Hr. capacity with
RPM diesel engine with battery charger. Base plate, AVM
pad etc. complete as directed including necessary concrete
platform as directed. (Make:-L)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
149 Fire Pumps & Accessories, Yard Hydrant, Internal Hydrant, 1.00 Nos. 153924.00
Hose Reel & Sprinkler System Supply, Installation, Testing
& Commisioning of Main Fire Pump Of Capacity 20 H.P.
with 55 mtr. Head, Pump
150 Supply, Installation, Testing & Commisioning of control 1.00 Nos. 90900.00
Panel suitable for automatic operation of fire fighting pumps
consisting (a) Necessary cabling, wiring, earthing from panel
to individual equipment shall be included in the quoted price.
(b) Facility for more selection i.e. auto or manual. (c)
Protection failure and control cabling. (d) Interlocking of
pressure switch with pumps.
151 Supply, Installation, Testing & Commisioning of 150mm 1.00 Nos. 3535.00
dia. Pressure Gauge of range 0 - 15 kg/cm3 confirming to as
per specification complete as required.
152 Supply, Installation, Testing & Commisioning of Pressure 1.00 Nos. 4545.00
Switches for automation of fire pumps, Pressure switches
shall be double pole, single throw type suitable for 3 phase
supply with diaphragm. Alluminium Enclosure with IP
protection as required.
153 Supply, Installation, Testing & Commisioning of the 40.00 meter 2390.67
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows /
reducers / couplings / unions / bends / flanges etc. and laying
on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.A)150 mm dia
154 Supply, Installation, Testing & Commisioning of the 45.00 meter 1711.95
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows /
reducers / couplings / unions / bends / flanges etc. and laying
on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.b)100 mm dia
155 Supply, Installation, Testing & Commisioning of the 10.00 meter 1277.65
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows /
reducers / couplings / unions / bends / flanges etc. and laying
on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.c)80 mm dia
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
156 Supply, Installation, Testing & Commisioning of the 50.00 meter 1100.90
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows /
reducers / couplings / unions / bends / flanges etc. and laying
on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.d)65 mm dia
157 Supply, Installation, Testing & Commisioning of the 45.00 meter 989.80
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows /
reducers / couplings / unions / bends / flanges etc. and laying
on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.e)50 mm dia
158 Supply, Installation, Testing & Commisioning of the 40.00 meter 858.50
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows /
reducers / couplings / unions / bends / flanges etc. and laying
on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.f)32 mm dia
159 Supply, Installation, Testing & Commisioning of the 150.00 meter 555.50
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows /
reducers / couplings / unions / bends / flanges etc. and laying
on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.g)25 mm dia
160 Supply, Installation, Testing & Commisioning of C.I. 1.00 Nos. 9738.42
Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets
complete as required. A)150 mm dia
161 Supply, Installation, Testing & Commisioning of C.I. 2.00 Nos. 8932.44
Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets
complete as required. b)100 mm dia
162 Supply, Installation, Testing & Commisioning of C.I. 2.00 Nos. 5555.00
Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets
complete as required. c)50 mm dia
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
163 Supply, Installation, Testing & Commisioning of Cast iron 1.00 Nos. 9090.00
Dual plate Check valve (PN 1.6) a)150 mm dia
164 Supply, Installation, Testing & Commisioning of Cast iron 2.00 Nos. 7564.90
Dual plate Check valve (PN 1.6) a)100 mm dia
165 Supply, Installation, Testing & Commisioning S.S. Single 3.00 Nos. 5656.00
Headed Fire Hydrant Valve with 80mm N.B. Flanged inlet,
63 mm dia. Female instantaneous outlet type S.S. coupling,
blank cap, chain, twist release type lug & all accessories
Confirming to IS:5290. Including fixing with supports,
flanged tapping from wet riser, orifice plate.
166 Supply, Installation, Testing & Commisioning of Weather 2.00 Nos. 4595.50
proof standard M.S. Fire Hose Cabinet wall mounting type
(450mm x 450mm x 250mm deep) having single or double
opening with necessary locking arrangement by allan key
suitable for housing 1 nos. hose pipe, 1 nos. Branch pipe &
nozzle spanner.
167 Supply, Installation, Testing & Commisioning non 2.00 Nos. 5641.86
percolating rubber reinforced lined Fire Hose pipe (as per
IS:636) of 63mm dia and 15 mtr. Long. The hose shall be
rated for burst pressure pf 35.7kg/sqcm. Hose shall be
complete with ISI marked SS male & female coupling
(IS:903) bound & riveted to hose pipe with copper rivets &
1.5mm copper wire.
168 Supply, Installation, Testing & Commisioning of 63mm dia. 2.00 Nos. 5641.86
Instantaneous pattern SS 304, short branch pipe, 20mm dia
nozzle confirming to IS
169 Supply, Installation, Testing & Commisioning of First Aid 2.00 Nos. 6565.00
Hose Reel equipment conforming to 15:884 comprising of
hose reel drum, 8 mm shut off noz:z.le, Ru bber hose of
mm dia x 30 mtr. long, painting, swinging type fixing
bracket, anchor fastener, bolts & nuts etc.
170 Supply, Installation, Testing & Commisioning of SS Ball 2.00 Nos. 858.50
Valve. A) 25mm dia.
171 Supply, Installation, Testing & Commisioning of Cast Iron 2 1.00 Nos. 8585.00
Way Fire Brigade Inlet as per 1S: 904 having 63 mm dia
in/et with blank cap and chain with necessary fit ti ngs,
flanges, nut bolts etc. complete as required. (For Hydrant
172 Supply, Installation, Testing & Commisioning of Gun Metal 1.00 Nos. 959.50
Air Release Valve with necessary fittings. Size: 25mm (For
173 Supply, Installation, Testing & Commisioning of Quartzoid 30.00 Nos. 454.50
Bulb type Sprinkler Heads. A) Pendent Sprinkler 57°C
174 Fire Alarm System Alarm panel Microprocessor based 8 zone 1.00 Nos. 16665.00
175 Manual Call Point 3.00 Nos. 454.50
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
176 2 core x 1.5 sqmm wire with pvc conduct and required 250.00 Rmt. 166.65
177 Smoke Detector 30.00 Nos. 1565.50
178 II) Fire Extinguisher and Exit Signages Supply, installlation, 10.00 Nos. 6447.84
testing and commissioning of Carbon Dioxide (CO2) type
Fire Extinguisher of 4.5 kg confirm to IS:15683, with ISI
marked / TAC approved fitted with required accessories
including wall suspension brakets.
179 Supply, Installation, Testing & Commisioning of ABC type 10.00 Nos. 2222.00
6kg confirm IS:15683, with ISI marked / TAC approved
fitted with required accessories including wall suspension
180 Signage Boards 25.00 Nos. 252.50
181 P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 7.00 Sqmt 1311.18
mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse
sand) on new surface or fixing on existing flooring by
adhesive material including dismentaling of existing flooring
and jointed with color cement slurry including finised with
flush pointing & cleaning the surface etc. complete for light
182 Providing and fixing window having extruded aluminum 4.00 Sqmt 1713.70
Colour anodized section frame main outer size 63.50 x
x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal two track
member size 61.85 mm x 31.75 mm x 1.20mm @ wt.of
0.695 Kg/mt, vertical member of size 61.85 mm x 31.75mm
x 1.30 mm @ wt.of 0.659 Kg/mt with sliding shutters of
horizontal member size 40mm x 18mm x 1.29mm @ wt.of
0.456Kg/mt, vertical member of size 40mm x 18mm x
1.29mm @ wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with
mm thick transparent bronze colour tinted float glass with
powder coated aluminum fittings and fixtures and transparent
silicon sealant glass fixing to frame as per details etc
complete for window.
183 Excavation for foundation upto 1.5 m depth including 40.00 Cum 272.57
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(B)
Dense or Hard soil
184 Excavation for foundation for depth from 1.5 m to 3.0 m 14.00 Cum 498.93
including sorting out and stacking of useful materials and
disposing of the excavated stuff upto 50 Meter
lead.(C) Hard Murrum
185 Providing and laying cement concrete 1:5:10 (1- Cement : 5- 3.00 Cum 2566.77
fine sand : 10- graded brick bat aggregates 40mm nominal
size) and curing complete excluding cost of formwork in (A)
Foundation and Plinth
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
186 Brick work using common burnt clay building bricks having 15.00 Cum 4214.33
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine
sand)(B) Conventional
187 Half brick masonry in common brunt clay building bricks 15.00 Sqmt. 618.79
having crushing strength not less than 35 Kg/Sq.Cm. in
Cement mortar 1:5 (1- Cement : 5 -coarse sand ) in
foundation and plinth (B) Conventional
188 Providing and laying cement concrete flooring 1:2:4 (1- 20.00 Sqmt. 352.01
cement : 2-coarse sand : 4-graded stone aggregate 20mm
nominal size) laid in one layer and finished with a floating
coat of neat cement. (B) 50mm thick.
189 Providing 15mm thick cement plaster in single coat on 88.00 Sqmt. 184.78
Rough (Similar)side of single or half brick walls for interior
plastering upto floor two level and finished even and smooth
in (i) Cement mortar 1:3 (1-cement:3-sand)
190 Providing and Laying ordinary cement concrete 1:2:4 (1- 4.00 Cum 6888.15
Cement 2- coarse sand : 4- graded stone aggregates 20 mm
nominal size) and finishing smooth with curing etc. complete
including the cost of formwork but excluding the cost of
reinforsement for R.C.C work in (iii) Slabs having more than
10 cm and upto 13 cm. thickness
191 Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. 4.00 Nos 958.17
size having weight not less than 35Kg.
192 Providing and laying (to level or slopes) and jointing with 10.00 Rmt 317.48
stiff mixture of Cement Mortar in proportion 1:1 Salt glazed
stoneware pipes including testing of pipes and joints
complete.(B) 150mm dia.
193 Providing, laying and jointing in true line and level 110 234.00 Rmt 876.12
diameter U.P.V.C (Type B) conforming to IS 13592-1992
with one end plain and other end socketed with rubber ring,
& fittings conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using
of PVC clamp of the size 110 mm diametre x 149 mm length
x 145 mm heigh at every 2000 mm center to center or shall
be concealed in walls as directed including necessary fittings
such as bends, shoes etc. including testing of pipes and joints
and jointed with adhesive solvent cement including cost of
194 Providing and Constructing sock pit of 2.46 mt. dia outside 2.00 Nos 35192.44
and 4 mt depth with honey combed masonary 6.50 mt. from
bottom and 0.60 mt. brick masonary in C.M. 1:6 top with
RCC slab cover of M200 vent pipe 1.8mt. Long 75mm dia &
C.I. cover and cowel vent etc. comp
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
195 Point wiring for Light / Bell with 2-1.5 sq.mm & earth 399.00 Pts 485.81
wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires up to
10 mtr length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed.(f) with
medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete.Cat-III (Make:-
Honeywell, L&T, Havells, Indoasian, Legrand)
196 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 157.00 Pts 674.68
sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multi strand copper wires up to 10 mtr length,
in below type of pipe erected with 6A Modular type switch
and hum free EME step type electronic fan regulator
mounted and accessories with earth continuity of following
type erected on PVC / Metallic/Wooden box, single
mounting base frame covered with textured/metallic/white
front plate modules erected on / in wall / ceiling as per pipe
erected. with necessary ceiling rose / H.D.Connector as
directed..(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete.Cat-
III (Make:- Honeywell, L&T, Havells, Indoasian, Legrand)
197 Point wiring for Individual Plug with & earth wire of 1.5 88.00 Pts 510.05
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr length,
in below type of pipe erected complete with Modular type
switch & 5 pin Plug erected on PVC / Metallic/Wooden box
covered with appropriate front plate modules erected on / in
wall / ceiling as per pipe erected with following type of
accessories. [I] For 6A Plug and 6 a switch with 2-1.5
sq.mm Cu. Wire from nearby switchboard/mcb db board (f)
with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling completeCat-III (Make:-
Honeywell, L&T, Havells, Indoasian, Legrand)
198 Point wiring for on board Looped Plug with 6A Modular 158.00 Pts 257.55
type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected
on / in wall / ceiling with following type accessories.Cat-III
(Make:- Honeywell, L&T, Havells, Indoasian, Legrand)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
199 Providing following type of Modular Type Accessories 3.00 Nos. 160.59
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (3) Two Pin/RJ-11
Telephone Socket[A] For One Gang Cat.III (Make:-
Honeywell, L&T, Havells, Indoasian, Legrand)
200 Providing following type of Modular Type Accessories 3.00 Nos. 160.59
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (4) TV Co-axial
Socket outlet Cat-III (Make:- Honeywell, L&T, Havells,
Indoasian, Legrand)
201 Providing following type of Modular Type Accessories 158.00 Nos. 25.25
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (7) Blank Plate
Single Cat.III (Make:- Honeywell, L&T, Havells,
Indoasian, Legrand)
202 Providing following type of Modular Type Accessories 33.00 Nos. 160.59
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (8) Computer RJ-
45 socket Cat-III (Make:- Honeywell, L&T, Havells,
Indoasian, Legrand)
203 Providing following type of Modular Type Accessories 61.00 Nos. 180.79
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (9) 16 Amp. SP one
way switch Cat-III (Make:- Honeywell, L&T, Havells,
Indoasian, Legrand)
204 Providing following type of Modular Type Accessories 61.00 Nos. 199.98
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (10) 6/16Amp.
Universal socket Cat-III (Make:- Honeywell, L&T,
Havells, Indoasian, Legrand)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
205 Providing following type of Modular Type Accessories 16.00 Nos. 604.99
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (21) Foot Light as
per colour requirement with concealed box, modular
accessories, acrylic glass cover with suitable LED watt with
all accessories as per following module (c) Six modules
Cat-III (Make:- Honeywell, L&T, Havells, Indoasian,
206 Providing and erecting ISI mark Medium class RIGID PVC 1260.00 Mtrs. 33.33
PIPES of following size complete to be erected on/in wall or
ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed (b) 25 mm
207 Providing and erecting ISI mark Medium class RIGID PVC 160.00 Mtrs. 54.54
PIPES of following size complete to be erected on/in wall or
ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed (c) 32 mm
208 Providing & erecting PVC Corrugated Flexible Conduit with 240.00 Mtrs. 21.21
required nos. of coupling, PVC bushes, Check-nuts etc.
complete of following sizes. (2) 25 mm
209 Providing & erecting PVC Corrugated Flexible Conduit with 120.00 Mtrs. 27.27
required nos. of coupling, PVC bushes, Check-nuts etc.
complete of following sizes. (3) 32 mm
210 Supplying and laying UPVC cable trunking system 25.00 Mtrs. 428.24
comprising unplasticised polyvinyl, chloride rigid material
with ignition free and flame proof confirming BS with
necessary end caps Internal and external bend, flat bends,
coupler, tee etc..All necessary accessories and measuring of
following sizes (2) 100 mm x 50 mm trunking
211 Providing and erecting Mains with 1.1 KV grade FRLS PVC 5166.00 Mtrs. 82.82
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth continuity of
following size (A) with medium class Rigid PVC pipe and
accessories (b) 2 wire 2.5 sq. mm (Make: -RR Kabel,
Havells, Avocab, KEI,Johnson)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
212 Providing and erecting Mains with 1.1 KV grade FRLS PVC 2256.00 Mtrs. 112.11
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories (a)
wire 4 sq. mm (Make: -RR Kabel, Havells, Avocab,
213 Providing and erecting Mains with 1.1 KV grade FRLS PVC 630.00 Mtrs. 425.21
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories (i)
wire 10 sq. mm (use earth wire of 4 sq.mm ) (Make: -RR
Kabel, Havells, Avocab, KEI,Johnson)
214 providing and erecting Mains with ISI marked, 1.5KV grade 150.00 Mtrs. 91.91
electrolyte multi stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size (Specifically for
control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and
bolts if required. (f) One wire 10.00 sq. mm
215 providing and erecting Mains with ISI marked, 1.5KV grade 30.00 Mtrs. 300.98
electrolyte multi stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size (Specifically for
control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and
bolts if required. (i) One wire 35.00 sq. mm
216 Supplying and erecting Flexible PVC insulated multi strand 278.00 Mtrs. 22.22
multi core 1.1 kv grade ISI marked copper wires of following
size to be erected as directed. (c) 1.00 Sq.mm 2 core round/
flat PVC sheathed
217 Supplying and erecting Flexible PVC insulated multi strand 180.00 Mtrs. 46.46
multi core 1.1 kv grade ISI marked copper wires of following
size to be erected as directed.e) 1.50 Sq.mm 3 core round
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
218 Providing & Erecting approved make following size of TV 135.00 Mtrs. 62.62
Co-axial flexible cable comprising inner conductor of solid
bare copper insulated with Foam PE & Secondary conductor
made of poly - Aluminium film bonded Al. Braids @
suitable coverage overall sheathed with black PVC
insulation. e).RG-11
219 Supplying & erecting approved make Telephone Cable 75.00 Mtrs. 20.20
electrolytic copper conductor PE insulation twisted in two
pairs, & wrapped with FRLS PVC tape & sheathed with
FRLS PVC or HFFR outer Jacket suitable for telephone
wiring & confirming to C-DOT erected in existing pipe. of
following size of conductors & nos.of pairs. With necessary
connections. [A] Conductor Size 0.5 mm (a) Unarmoured 2)
220 Supplying & erecting approved make LAN cable of 1056.00 Mtrs. 47.47
following size in existing pipe as per direction [C] CAT -
221 Providing & erecting main Distribution (MDF) indoor type, 4.00 Nos. 994.85
back mounted frame as per DoT standard approved with
krone strips(a) Suitable for 10 pair
222 Supplying & erecting M.S. Box having 16 Gauge painted 14.00 Nos. 88.88
with red oxide or Heavy duty PVC box erected flushed on
wall or concealed in wall with necessary plastering &
finishing as directed of following size. (c) 200 mm x 250 mm
223 Providing & erecting Switch board for Computer or electric 33.00 Nos. 1133.22
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with
single mounting base frame covered with textured/metallic
/white front plate,modules erected with necessary
connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories.Cat-III
(Make:- Honeywell, L&T, Havells, Indoasian, Legrand)
224 Decorative call bell Ting-tong box type 250 volts complete 1.00 Nos. 71.71
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
225 Supplying and erecting LED indoor fittings with LEDs of 313.00 Nos. 373.70
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with
diffuser with company mark/name 160V to 270V, Power
Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.) (A) Tube Light with
integral/ non-integral driver . (iv) 22-24 Watts, Surge -
2KV,IP-20, conventional 4 feet Cat III (Make:- Wipro,
LT,Philiphs,Havells,Jaquar)
226 Supplying and erecting led lamps with following wattage 45.00 Nos. 112.11
capacity of 220 to 240 voltage, minimum 15000 burning
hours life, 500 V in built-surge protection,Polycarbonate
diffuser, mounting suitable for E14 / E27 / B22 lamp holders,
pf >= 0.5 (A) LED Lamps integral type, with PC diffuser
suitable LAMP holder (i) 5 to 8 watts Cat-III (Make:-
Wipro, LT,Philiphs,Havells,Jaquar)
227 Supplying and erecting LED street light / Flood light fittings 20.00 Nos. 4997.48
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD
< 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.) (A)
Street Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage
protection.(ii) above 48 to 60 Watts Cat-III (Make:- Wipro,
LT,Philiphs,Havells,Jaquar)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
228 Supplying and erecting LED street light / Flood light fittings 10.00 Nos. 8453.70
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD
< 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.) (B)
Flood Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage
protection.(v) above 120 to 160 watts Cat-III (Make:- Wipro,
LT,Philiphs,Havells,Jaquar)
229 Supplying and erecting LED street light / Flood light fittings 2.00 Nos. 4819.72
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD
< 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.) (C)
Post Top Lantern LED fitting comprises of finish cast
aluminum spigot and spun aluminum canopy fixed with opal
polycarbonate, pipe arrangement for vertical mounting driver
and accessories wired upto terminal block.IP 65 (ii)32-40W
Cat-III (Make:- Wipro, LT,Philiphs,Havells,Jaquar)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
230 Providing and erecting Approved make Four pole moulded 25.00 Nos. 6173.12
case circuit breaker having breaking capacity ICU of 25 KA.
at 415 V,having normal current rating up to 25 A to 100A.
with Fixed thermal & magnetic release suitable to work on
A.C. supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
(Make:- Indoasian, L&T (LK), ABB, Schneider)
231 Providing and erecting Approved make Four pole moulded 5.00 Nos. 8055.76
case circuit breaker having breaking capacity ICU of 35 KA.
at 415 V. having normal current rating 125A. with Fixed
thermal & magnetic release suitable to work on A.C.supply
50 c/s. with all internal connections, spreader tinned copper
& complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III (Make:- Indoasian,
L&T (LK), ABB, Schneider)
232 Providing and erecting Approved make Four pole moulded 2.00 Nos. 20946.39
case circuit breaker having breaking capacity ICU of 35 KA.
and above at 415 V . having normal current rating 250A.
with variable thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III (Make:-
Indoasian, L&T (LK), ABB, Schneider)
233 Providing and erecting Approved make Four pole moulded 1.00 Nos. 25228.79
case circuit breaker having breaking capacity ICU of 50 KA
and above at 415 V having Normal current rating 400A.
with variable Thermal & magnetic release suitable to work
on A.C.supply 50 c/s. With all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III (Make:-
Indoasian, L&T (LK), ABB, Schneider)
234 Supplying & erecting approved make Four Pole 415V 1.00 Nos. 22255.35
change over switch interior for panel mounting with
operating mechanism A.C.23 duty confirming to IS for
(F)400A (Make:- Indoasian, L&T (LK), ABB, Schneider)
235 Providing and erecting Approved make Earth fault Relay 1.00 Nos. 5415.62
suitable to mount with inter connection suitable to following
size of moulded case circuit breaker having CT ratio &
MCCB rating as following along with shunt trip 220V AC.
with all internal connections & complete erected in existing
M.S.housing. (3) 250 A -400 A , CT Ratio 1/400
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
236 Supplying and erecting triple pole & neutral 440V / 500V 12.00 Rn.Mtrs 1961.42
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary connections.
(A) Suitable for 100 Amp. Capacity
237 Supplying and erecting triple pole & neutral 440V / 500V 9.00 Rn.Mtrs 3202.71
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary connections.
(B) Suitable for 200 Amp. capacity
238 Supplying and erecting triple pole & neutral 440V / 500V 2.00 Rn.Mtrs 7319.47
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary connections.
(D) Suitable for 400 Amp. capacity
239 providing and erecting Miniature circuit breaker single pole 32.00 Nos. 270.68
0.5A to 2A system and having breaking capacity 10 KA to
be erected in existing box. confirming to IS 8828/1996 with
ISI Mark Cat.III (Make:- Indoasian, L&T (LK), ABB,
240 Providing and erecting Miniature circuit breaker single pole 168.00 Nos. 112.11
6A to 25A suitable to operate on 240 V A.C. system and
having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark Cat-III
(Make:- Indoasian, L&T (LK), ABB, Schneider)
241 Providing & erecting 240 V MCB double pole switch for 6.00 Nos. 295.93
lighting Load (B Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following
capacity (B) 40 Amp. Cat-III (Make:- Indoasian, L&T
(LK), ABB, Schneider)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
242 Providing & erecting 415 V MCB Four Pole for Motor & 16.00 Nos. 737.30
Inductive Load (C Curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following
capacity (B.) for 63 Amp. Cat-III (Make:- Indoasian, L&T
(LK), ABB, Schneider)
243 Providing and erecting Sheet Steel powder coated MCB 14.00 Nos. 2913.85
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same
company of MCB to be used) suitable for (B) three phase
incoming and single phase horizontal type outgoing Per
phase isolation type (PPI) (b) sheet steel double door (ii)6
way (Make:- Indoasian, L&T (LK), ABB, Schneider)
244 Providing and erecting Approved make RCCBs conforming 42.00 Nos. 2235.13
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having characteristic
of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max.
rating erected as directed (iI) 40 Amps.DP Cat. III (Make:-
Indoasian, L&T (LK), ABB, Schneider)
245 Providing and erecting metallic vitrified danger notice board 5.00 Nos. 69.69
as per language suggested by engineer incharge for
MEDIUM VOLTAGE installation to be erected as per IS-
246 Providing and erecting Annealed bare Copper wire 8 to 16 30.00 Kgs. 794.87
247 Providing and erecting Pipe type earthing having 150 20.00 Nos. 368.65
cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
248 For using salt and charcoal / coke as required for pipe type 20.00 Nos. 171.70
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
249 Supplying & erecting earth pit of minimum bore dia.150mm 5.00 Nos. 4591.46
size approved make Earthing Electrode consisting Pipe-in-
Pipe Technology as per IS 3043-1987 made of corrosion free
hot dipped G.I.Pipes having Outer pipe dia of 50mm having
80-200 Micron galvanising, Inner pipe dia of 25 mm having
200-250 Micron galvanising, connection terminal dia of
12mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable
for following type of applications with chamber and heavy
duty cover. (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation
duly stamped and signed by agency and officer Incharge has
to ensure the value of earthing resistane mentioned in test
Certificate) & having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter
testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must be
submitted by Agency. (a) For Electrical Installation up to
440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
250 Providing & erecting weather proof, dust & vermin proof, 9.00 Sq.Mtrs. 14902.55
floor mounted front operated indoor type cubical panel
board necessary IP-42 and above protection as per approval
from engineer incharge made from 14 SWG thick CRC M.S.
sheet for outer body & doors, 16 SWG thick CRC M.S.sheet
for internal partitions with necessary accesories , supporting
angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per
requirements & instruction of engineer-in-charge with
erection of supplied switch gears, BUSBARS, suitable size
of inter connecting PVC copper wire / copper-aluminium
strips, rubber grommets, rib, bakelite control fuses/MCB for
measuring instruments, earth bus & earth bolts, foundation
flange - bolts-base Plates, sufficient nos. of hinged doors,
handles with locking arrangement and rubber gasket,heavy
duty end terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be
painted with epoxy powder coating. (The rates excludes the
cost of switchgears, bus bars, inter connecting mains &
Copper Aluminium strips, meters, Fuses etc. The dimension
shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with
following size.(B) The standard companies switch gear shall
be used and only manufacturers at CPRI approved factory (i)
with 350mm depth
251 Providing , erecting , fabricating the M.S. structure as per 140.00 Kgs. 77.77
requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections complete
with cutting, welding, grinding & finishing duly painted with
one coat of red oxide with erection on site as per direction of
engineer in charge with necessary grouting, cementing,
plastering & finishing complete.
252 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured 190.00 Mtrs. 220.18
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (B) 3 1/2 core 35 Sq. mm (
16 Sq. mm 1/2 core) (Make: -RR Kabel, Havells, Avocab,
253 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured 120.00 Mtrs. 490.86
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (E) 3 1/2 core 95 Sq. mm (
50 Sq. mm 1/2 core) (Make: -RR Kabel, Havells, Avocab,
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
254 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured 360.00 Mtrs. 904.96
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (H) 3 1/2 core 185 Sq. mm
( 95 Sq. mm 1/2 core) (Make: -RR Kabel, Havells, Avocab,
255 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured 230.00 Mtrs. 117.16
cable multistrand / Solid Aluminium conductor for 1.1 KV.
to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (A) 4 core 4 Sq. mm
(Make: -RR Kabel, Havells, Avocab, KEI,Johnson)
256 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured 550.00 Mtrs. 140.39
cable multistrand / Solid Aluminium conductor for 1.1 KV.
to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (C) 4 core 10 Sq.
mm (Make: -RR Kabel, Havells, Avocab, KEI,Johnson)
257 Making trench in soft soil of suitable width of 90 cm deep 455.00 Mtrs. 55.55
for laying cable or locating the fault all over the run and
back filling the same and making the surface as normal
258 Making trench in Hard Murrum / Tar Road of suitable width 227.50 Mtrs. 74.74
of 90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same
and making the surface as normal ground.
259 Making trench in Hard Murrum / Tar Road of suitable width 91.00 Mtrs. 357.54
of 90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same
and making the surface as normal ground. (B) If additional
machinery like hammer driller or JCB use [Add]
260 Providing & laying. R.C.C. Hume pipe for cable to be laid 90 60.00 Mtrs. 263.61
cm. below ground across the road crossing or on floor with
necessary material in an approved manner and making the
ground as per original. (E)150 mm dia
261 Providing & laying approved make Double walled 824.50 Mtrs. 62.62
corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable (A)
50 mm Outer Dia
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
262 Providing & laying approved make Double walled 306.00 Mtrs. 137.36
corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable (D)
120 mm Outer Dia
263 Providing & laying approved make ISI marked Rigid PVC 50.00 Mtrs. 236.34
pipe having 6Kg / cm2 (Class-3) to be erected at road
crossing on or floor as directed for laying of cable. The pipes
as following size of dia & weight per 6 mtr.(F) 110 mm inner
Dia. (11.63 Kg/6 RMT)
264 Providing and, fixing heavy duty flange type brass cable 20.00 Nos. 33.33
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables. (A) 2 to 4 core 2.5 / 4 Sq. mm
265 Providing and, fixing heavy duty flange type brass cable 44.00 Nos. 38.38
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables. (C) 2 to 4 core 10 Sq. mm
266 Providing and, fixing heavy duty flange type brass double 8.00 Nos. 75.75
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (B) 3 & 1/2
core 35/50 Sq. mm
267 Providing and, fixing heavy duty flange type brass double 8.00 Nos. 131.30
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables.(D) 3 & 1/2
268 Providing and, fixing heavy duty flange type brass double 2.00 Nos. 238.36
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (G) 3 & 1/2
core 185 Sq. mm
269 Solder less crimping type Aluminium lugs conforming to IS 80.00 Nos. 6.06
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (A)
270 Solder less crimping type Aluminium lugs conforming to IS 176.00 Nos. 13.13
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (B)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
271 Solder less crimping type Aluminium lugs conforming to IS 32.00 Nos. 20.20
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (D)
272 Solder less crimping type Aluminium lugs conforming to IS 32.00 Nos. 40.40
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (F)
273 Solder less crimping type Aluminium lugs conforming to IS 8.00 Nos. 80.80
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. ( I )
274 Providing and erecting Approved make Ceiling fan with 157.00 Nos. 1596.81
double ball bearing ISI mark with condenser A.C. 23OV.50
c/s.1200 mm. sweep complete, canopy erected on existing
hook or clamp with earthing. [Make shall be approved by
Engineer in charge] (Make:- Crompton, Havells, Orient)
275 Supplying and erecting 19 / 20 mm. nominal bore Medium 157.00 Mtrs. 108.07
Class M.S. Pipe down rod erected duly painted for fan
complete with proper insulation without leckage and earthing.
276 Supplying & erecting fan hook box of 10 mm M.S. round 157.00 Nos. 108.07
bar bounded to the RCC bars up to 50mm length each side
and pierced through a 16 Gauge M.S. box / Heavy Duty
PVC box complete erected concealed in Ceiling with
necessary finishing.
277 Supplying & erecting single phase approved make industrial 40.00 Nos. 2054.34
exhaust fan suitable for medium duty ring mounted low noise
operation suitable for medium duty having following dia size
and maximum speed in RPM [A] 305 mm dia 900 RPM
Cat.II (Make:- Crompton, Havells, Orient)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
278 Supplying and erecting approved make Octagonal pole made 20.00 Nos. 8192.11
from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with
integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
MCB Mounting, stud type terminal and arrangement for
cable termination to be erected With Suitable foundation
(Included) as per details given by manufacturer considering
site requirement.(D) 6 Mtr. Long 70 mm Top X 135 mm
bottom dia, 3 mm thickness with 200mmX200mmX12mm
base plate, 4-M20 Bolts and 600mm long with necessary G.I.
J Bolts .Approx Pole weight 59 kg
279 Supplying & erecting approved make SMC press moulded 12.00 Nos. 515.10
composite FRP. loop-in, loop-out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E),DIN
rail for mounting mob & hinged doors as per requirement
having locking arrangements with mounting clamp with nuts,
bolts & washers suitable for erection on pole with cable
clamps& earth bolt of following size of box.(b) 250mm x
200mm x 100mm [deep]
280 Providing street light pole bracket comprising main B Class 20.00 Nos. 561.56
MS pipe of 4.2 cm/require outside dia. complete with
suitable B Class M.S. sleeve tubing of approx. 45cms.length
and suitable for 76.5 mm / 80mm. / require size pole top
having sufficient fastners for fixing the brackets and having
spread of 1 mtr. length with suitable rise as per site condition
& suitable welded stiffener reducer and nipple with check
nut complete painted with one coat of Red oxide / PU base
primer and two coats of Aluminium / PU paint. paint with
following nos of arms. [A] Single Arm bracket 1 Mtr
281 Supplying & erecting approved make Digital time switch 2.00 Nos. 3168.37
having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD
display. Also comprised permanent ON/OFF switching.
Programming switches & housed in fire proof thermoplastic
enclosure & transparent cover erected as required with
necessary connection erected as directed.
282 Supplying & erecting power contactor ,AC3 duty for time 2.00 Nos. 2782.55
switch complete erected as per direction Cat III (Make:-
Indoasian, L&T (LK), ABB, Schneider) [D] 4 pole 440V
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
283 Providing & Erecting full SS Body (SS 304) Split type water 5.00 Nos. 61115.10
cooler having storage capacity 160 to 175 Ltr.(Tank SS 304)
& Cooling capacity 150 ltr. Per hour @ an ambient temp of
350 C.The outlet temp. of the water should drop by 150C
within a hour,The water cooler should be comprising of
hermetically sealed Reciprocating compressor with R134A,
fan motor, Copper Condensing unit with company fabricated
Outdoor Unit water tank surrounded by evaporating coil,
thermostats, relay etc.complete with necessary copper tube &
Insulation, M.S Chanel Stand with Painting for water tank &
M.S. Powder Coated Stand for Outdoor unit with
Installation. With DPELCB and 4 Way DB Box with
accessory Three core Cord for connection.(Make:- Blue
Star,Usha,Voltas)
284 Supplying and erecting water filter cum purifier with ultra 5.00 Nos. 5424.71
violate technology. (Aquaguard / waterdoc model or
equivalent symphony/ crystal/videocon model)
285 Supplying & erecting 5 stage single reverse osmosis water 5.00 Nos. 29187.99
purification system with M.S. powder coated frame, prefilter
housing with 'O' ring presediment filter GAC filter, carbon
filter suitable buster DC pump capacity 80 psi, mention with
40 psi inline type post carbon filter auto low & high pressure
switches with following size of storage tank & LPH capacity
& erected as directed[C] 50 Ltr / Hr with 150 psi 2 nos
286 Supplying and erecting horizontal / vertical mounting type 20.00 Nos. 11455.42
storage water heater with copper container housed in
M.S./S.S./ABS body insulated with glass wool/puff complete
with heating elements,adjustable thermostats 300C to 850C,
indicating lamp, safety valve, fusible plug, etc.complete
erected with coach bolts, nuts. washers & cementation (C)25
Ltr. with 2 KW. heating element Premium Category
287 Supplying and erecting chromium plated heavy duty brass 20.00 Nos. 181.80
valve for inlet pipe of water heater 15 mm dia.)
288 Supplying and erecting 15mm brass non-return valve for 20.00 Nos. 232.30
inlet pipe of storage water heater.
289 Supplying and erecting dead pressure releasing valve for 20.00 Nos. 385.82
storage type water heater with necessary materials.
290 Providing & erecting fibre reinforced PVC flexible pipe with 80.00 Rmts. 181.80
brass locking nuts & washers & clips at both ends complete
erected without leakage
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
291 Supplying, installing, testing & commissioning of SOLAR 5.00 Nos. 189956.76
WATER heating system as per prevailing IS code
comprising of Solar flat locket collector, stainless steel hot
water storage isolated tank with S.S. heat exchanger,
absorber made of copper sheet & copper tube of following
capacity in liter / day (LPD) with "B" size aluminium box
collector with appropriate capacity electrical backup
arrangement (Excluding inlet & outlet pipe lines) (E)
Capacity of 1000 LPD
292 Supplying & erecting resin bonded flap rock wool / glass 450.00 Mtrs. 767.60
wool with conductivity valve 1.67 sq.mm per watt & to with
stand the temp. to 100 degree centigrade C thickness 50mm
with G I pipe of following size dia "B" class as per IS:1239.
The plastic sheet to be used as covering of glass wool. Al.
cladding besides other materials like chicken mesh, 26 G Al.
Sheet shall be used for cladding the insulation pipe.(E) for
293 Supplying and erecting approved make panel mounting type 5.00 Nos. 1275.63
Digital Voltmeter having 3 digits LED display, 0 to 750 AC
Volts range erected on existing panel board with all
connection, wiring etc .with manufacturers calibration
294 Supplying and erecting approved make panel mounting type 5.00 Nos. 1558.43
Digital Ammeter having 3 digits LED display, external CT
operated, calibrated for 0 to 1000 Amps suitable to operate
on 500 Volt AC , erected on existing panel board with all
connection, wiring etc .with manufacturers calibration
295 Providing & erecting L.T. Current Transformer with bar 15.00 Nos. 274.72
primary 50/5 to 1000/5 ratio 15 VA burden erected in
existing CRCA box duly secured with insulating materials
connected to the meter
296 Supplying and erecting approved make suitable panel 15.00 Nos. 43.43
indicator LED type lamp, lens cover, complete erected with
necessary connections.
297 Providing & erecting open well horizontal mono block pump 2.00 Nos. 15707.52
set with cast iron body, complete for three phase
submersible motor having[C] For 3 HP 3 phase open well
horizontal mono block pump set suitable for 85 LPM to
LPM @ 11 mtr to 33 mtr head suitable for 50/65 mm dia
delivery pipe Cat.II (Make:- Crompton, Lubi )
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
298 Supplying & erecting approved make motor control cubical 2.00 Nos. 7722.46
panel (Direct - on - line) made from 16 G. CRCA sheet duly
epoxy powder painted inside and outside with hinged doors
and locking, arrangement consisting of suitable size of ON-
OFF isolator (AC - 3/23duty) main fuses, single phasing
preventer, indicating lamps for R- Y - B phases, overload
relay, Automatic water level controller, Ammeter, Voltmeter
each with two way selector switch incoming, wires duly
socket crimped, main contactor & overload relay, start - stop
push buttons, to be erected on angle iron frame grouted on
wall as directed. The isolator, overload relay & contactors
will be of L & T, Siemens or BCH make only.(A) DOL up to
299 Providing and erecting ISI marked PVC insulated PVC 90.00 Mtrs. 146.45
Sheathed Flat flexible Submersible copper cable approved
make of following Size. (C) 3 Core x 4 Sq. mm
300 Providing Water proof straight Joint in PVC insulated flat 2.00 Nos. 189.88
flexible copper cable by using insulating material, water
proofing material, & making the joint complete. (A) Up to
301 Supplying of following size of HEAVY UPVC column pipe 30.00 Rmts. 359.56
with coupler and wire lock [B] 50 mm dia
302 Supplying, & erecting C.I. swing, check type non-return 2.00 Nos. 1020.10
(Reflux) Valve -ISI marked suitable for following size (A)
303 Supply of following size of TOP & BOTTOM accessories 2.00 Per Set 1489.75
i.e. Adaptor set (CI) long, pump guard set, starter pipe
Rubber ring for submersible pump & UPVC column pipe as
directed by Engineer - in - charge with necessary plumbing
as desired.[D] 50 mm dia
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
304 Supplying, Erecting, Testing & Commissioning the 1.00 Nos 1575617.17
passenger / stretcher lift having following main features:[1]
GEAR LESS LIFT DRIVE (MRL) comprising of High
Starting torque Lift 3 phase 440 V A. C. Permanent Magnet
Synchronous motor of proper rating with high efficiency
shall be used.[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback closed loop
system shall be used for lift car and door operation which
shall be full collective selective operation hall call demand
response, UP/DOWN hall stops, Main, Up/ Down Contactor
with overload and phase reversal relay and safety controls.
[3] Car with M S platform with bracings of adequate size and
to sustain the impact load cabin + passenger with safety
factor of fire for steel and side panels of Stainless steel of
sheet of grade 304 duty. Car ceiling will be S.S. finishes with
aesthetic appearance with LED ceiling lights. Car flooring
shall be of s/s 304 chaker plate design sugeested of engineer
in charge. of engineer in charge. Car doors shall be of
stainless steel grade 304, hairline finish with centre opening /
telescopic automatic doors. Car panel will also be S.S.
finished with emergency stop device, mechanical door safety
device, facility of auto/ attended mode. All car panel buttons
and all floor switches must be with brail language as per lift
act.[4] All landing doors must be fire rated for 2 hour shall
be fully automatic centre opening/ telescopic opening made
of hairline finish steel grade of 304 with key holes and
infrared curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car
along with alarm switch shall be provided. Also, Emergency
Light & Fan should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow
along with floor position indicator shall be provided inside
the car and at all floors.
[7] Full height infra red curtain with multiple cross / crossing
light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided
accordingly of passenger capacity with Manual Rescue
Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till
excess load is removed. [10] Spring buffers/PU Buffers
shall be provided.
[11] Car fan as per passenger capacity with automatic sleep
timer shall be provided.
stainless steel grade 304, hairline finish with centre opening /
telescopic automatic doors. Car panel will also be S.S. 304 Estimated
Rates Total Amount
Rates Total Amount
Item finished with emergency stop device, mechanical door safety according
Item of work Quantity Unit
No. device, facility of auto/ attended mode. All car panel buttons In figure to estimated
and all floor switches must be with brail language as per lift quantities
act.[4] All landing doors must be fire rated for 2 hour shall
1 be fully automatic centre opening/2 telescopic opening made 3 4 5
of hairline finish steel grade of 304 with key holes and
infrared curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car
along with alarm switch shall be provided. Also, Emergency
Light & Fan should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow
along with floor position indicator shall be provided inside
the car and at all floors.
[7] Full height infra red curtain with multiple cross / crossing
light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided
accordingly of passenger capacity with Manual Rescue
Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till
excess load is removed. [10] Spring buffers/PU Buffers
shall be provided.
[11] Car fan as per passenger capacity with automatic sleep
timer shall be provided.
[12] Voice annunciator with suitable music shall be provided
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and submission of
calibration certificate submission, door key holes in the floor
doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine
room and monkey ladder for lift pit should be provided by
the lift agency, along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without
any extra cost, where ever required as / if directed by
engineer in charge. [17] Permanent wiring with necessary
safety devices like RCCB in all circuit, Over Voltage Under
Voltage protection and THD eliminator in circuit for lift
machine room and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug points shall be
provided by the agency. Only 3 phase Power Supply shall be
made available by department in lift machine room.
Necessary Earthing as per Lift Act/Rules shall be arranged by
[18] Any civil/ electrical works for additional and alteration
in lift shaft and machine room related to erection of lift shall
shall be provided.
[11] Car fan as per passenger capacity with automatic sleep
timer shall be provided. Total Amount
timer shall be provided. Total Amount
Item [12] Voice annunciator with suitable music shall be provided according
Item of work Quantity Unit to estimated
No. in lift car. In figure
[13] Self diagnostics system for operational and safety Rs. Ps.
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and submission of
calibration certificate submission, door key holes in the floor
doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine
room and monkey ladder for lift pit should be provided by
the lift agency, along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without
any extra cost, where ever required as / if directed by
engineer in charge. [17] Permanent wiring with necessary
safety devices like RCCB in all circuit, Over Voltage Under
Voltage protection and THD eliminator in circuit for lift
machine room and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug points shall be
provided by the agency. Only 3 phase Power Supply shall be
made available by department in lift machine room.
Necessary Earthing as per Lift Act/Rules shall be arranged by
[18] Any civil/ electrical works for additional and alteration
in lift shaft and machine room related to erection of lift shall
be made by lift agency without any extra cost.
(granite/marble fixing around all landing door openings are
not in lift agency’s scope.)
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all necessary
permission from lift inspector and other authorities. [20]
acrylic transparent licence/display A4 size holder in lift car
[20A] As per statutory requirement of Govt. Of Gujarat lift
& escalator act 2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift
inspection during/after lift erection and provide report by
third party authorized by concern licensing authority
5.agency has to provide third party insurance upto
completion of free maintenance period and submit the
document for the same.[21] Car Panel Operating Buttons
with floor position indicator/buttons must be of Auto Glow
type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should be
provided at appropriate height on the Rear & Side Wall
Panels in Lift Car. [23] With Necessary KVA rating voltage
[18] Any civil/ electrical works for additional and alteration Estimated
in lift shaft and machine room related to erection of lift shall Rates Total Amount
in lift shaft and machine room related to erection of lift shall Rates Total Amount
be made by lift agency without
Item ofany extra cost.
work Quantity Unit
No. In figure to estimated
(granite/marble fixing around all landing door openings are quantities
not in lift agency’s scope.)
1 [19] Agency has to provide all 2working drawings and 3 4 5
documents and liaison services for obtaining all necessary
permission from lift inspector and other authorities. [20]
acrylic transparent licence/display A4 size holder in lift car
[20A] As per statutory requirement of Govt. Of Gujarat lift
& escalator act 2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift
inspection during/after lift erection and provide report by
third party authorized by concern licensing authority
5.agency has to provide third party insurance upto
completion of free maintenance period and submit the
document for the same.[21] Car Panel Operating Buttons
with floor position indicator/buttons must be of Auto Glow
type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should be
provided at appropriate height on the Rear & Side Wall
Panels in Lift Car. [23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your controller, drive and all
equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for
lift is in scope of work which rating is sugested by CEICED
Department (electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION OF
LIFTS for PREMIUM category 1. Advanced
control system dual 64 bit embedded microprocessor with
CANBUS Serial Communication mode including
Regenerative power efficient operation,on site programming
facility, Anti nuisance, Pte-opening, BMS/RMS with
necessary online real time monitoring system having
necessary connectivity for remote monitoring & other
suitable supporting hardware & software devices to fulfil the
purpose. 2. Floor Indication LCD Display with call
registration & brail mark with arrival gong and hall lantern &
TFT Screen in the car with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS
Moonrock finish / Hair Line / Honeycomb for car and all
Doors, All landing doors must have fire rating up to 2 hours
and car door must have multi-level crisscross beam door
protection. 4. To & fro communication system & wiring
(i.e. car , control room & guard room ) and Each elevator are
equipped with remote monitoring system.agency has to
provide mobile app and user id and password for monitoring
Handrails of hairline finish steel grade of 304 should be
provided at appropriate height on the Rear & Side Wall
Panels in Lift Car. [23] With Necessary KVA rating voltage
Rates Total Amount
Rates Total Amount
Item controlled Stabilizer suitable for your controller, drive and all according
Item of work Quantity Unit
No. equipments of lift. In figure to estimated
[24] Necessary rating of DP Elcb and FP Elcb required for quantities
lift is in scope of work which rating is sugested by CEICED
Department (electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION OF
LIFTS for PREMIUM category 1. Advanced
control system dual 64 bit embedded microprocessor with
CANBUS Serial Communication mode including
Regenerative power efficient operation,on site programming
facility, Anti nuisance, Pte-opening, BMS/RMS with
necessary online real time monitoring system having
necessary connectivity for remote monitoring & other
suitable supporting hardware & software devices to fulfil the
purpose. 2. Floor Indication LCD Display with call
registration & brail mark with arrival gong and hall lantern &
TFT Screen in the car with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS
Moonrock finish / Hair Line / Honeycomb for car and all
Doors, All landing doors must have fire rating up to 2 hours
and car door must have multi-level crisscross beam door
protection. 4. To & fro communication system & wiring
(i.e. car , control room & guard room ) and Each elevator are
equipped with remote monitoring system.agency has to
provide mobile app and user id and password for monitoring
8 / 10 Passengers, Ground plus 3 upper floor with
Rated Speed of 1.0 m/sec., (C) With General PLUS
ADDITIONAL SPECIAL FEATURES attached herewith.
Total Cost of Construction Cost
Rupees Five Crore Eighty Five lakh Sixty Two Thousand Four Hundred Seventy Four and Twenty Five Paise Only
I/We am/are willing to carry out the work at ………………………………………………..% above/below (percent
should be written in figures and words) of the estimated rates mentioned above. Amount of my/our tender works out
*Estimated amount *Estimated amount
Put to tender Rs…58562474.25 Put to tender Rs.58562474.25
Deduct ……. % below Rs……………………..…. Add ……. % Avove Rs…………..….
Net Rs. …………………….… Total Rs. ………….…
The Contractor shall exhibit a board with detailed specification and details of work as directed by
the Engineer-In-Charge for which no extra payment shall be made.
The labour cess will be deducted as per prevailing rules i.e. 1% of the work done
3 GST and Income tax TDS will be deducted at a source while making payments of bills.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt.G.R.: PRC-
10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there
4 is a change as per actual mix design the cost of difference of cement consumption have been deducted from the
rate of original item at the rate of input rate mentioned in all the tender.
Deputy Executive Engineer Executive Engineer
R&B Sub Division R&B Division
Idar Himatnagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2.GR to be attached with DTP_SBD.pdf
BUILDING WORK BOOKLET.pdf
GRs - SBD with Index_compressed.pdf
GR - 1.pdf
GR - 2.pdf
GR - 3.pdf
GR - 4.pdf
GR - 5.pdf
BOQ_GIRL HOSTEL_ HIMATNAGART_2026_04_08.pdf
Details Specification - GIRL HOSTEL.pdf
Electrical Work.pdf
General Specification - State.pdf
SBD Book_2023_GIRLS HOSTEL AT HIMMATNAGAR.pdf
Specification Index - GIRL HOSTEL.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .