Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L1 | Accepted-AOC Being 1st Lowest | |
| 2 | L2₹21.6 L+₹1.7 L (8.74%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹21.9 L+₹2.0 L (10.3%)Rejected-Finance 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹27.9 L+₹8.0 L (40.3%)Rejected-Finance TARIN JALAL NAGAR SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L4 | Rejected-Finance Being 4th Lowest | |
| 5 | L5₹29.9 L+₹10.1 L (50.7%)Rejected-Finance MOH HATHITHAN NIGOHI ROAD SHAHJANPUR UP 242001 | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L5 | Rejected-Finance Being 5th Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Jul 2022, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR TO REFRIGERATOR, WINDOW TYPE AC, SPLIT TYPE AC, WATER COOLER, DESERT COOLER, VOLTAGE STABILIZER, DEEP FREEZER AND REPAIR AND MAINT OF INTERNAL WIRING AND FITTINGS, REPAIRS TO CEILING FANS OR EXHAUST FANS, GEYSERS, SUBMAIN WIRING, DBS, JUNCTION
2022_MES_532010_1
8206/E8
Open Tender
Civil Works
Item Rate
183 days
BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE EAST BAREILLY
₹90,000
Yes
2 Sept 2022
18 Jun 2022
22 Jul 2022
18 Jun 2022
20 Jul 2022
2 Jul 2022
18 Jun 2022 - 25 Jun 2022
Amount
S&F in replacement of the old unserviceable sealed compressor unit from existing Split/window type AC 1.5 ton capacity of any make by cutting and replacing the same with new sealed unit from authorised OEM workshop/manufacturer and reconnecting the replaced sealed compressor unit to its original position of air conditioner by brazing incl flushing out complete refrigerator system by applying CTC/nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity after complete equating and cleaning the system reinstalling the air conditioner at site and testing on false load to its satisfactor performance complete all as specified and directed.
All as per Srl item No.1 here in before but for capacity of air condition (2.00 ton) complete all as specified and directed.
M & L Flushing the complete refrigeration system and repairing of leakage pipe lines by brazing and charging the unit by compressor oil and refrigerant Gas-134 to its full capacity after evacuating and cleaning the complete system and installing, commissioning and testing for its smooth functioning for 72 hours on full load complete all as specified and directed.
S&F in repairs for over load protector suitable for AC protector complete all as specified and directed.
S&F in repairs for condensor unit copper type suitable for split/window AC 1.5 ton capacity complete all as specified and directed.
S&F in repairs relay suitable for 1.5 Ton (window/Split type) air conditioner complete all as specified and directed.
S&F in repairs thermostat switch for AC complete all as specified and directed.
S&F in repairs switch controlling knobs along with complete control panel for any make and any size of AC complete all as specified and directed.
S&F in repairs running capacitor of required 36/45 MFD complete all as specified and directed.
S&F in repairs starting capacitor of required 120 MFD complete all as specified and directed.
M&L for repairing of voltage stablizer of any make and size of 4 KVA to 5 KVA by repairing/replacement of electric circuit and rewinding including insulating materials complete all as specified and directed.
S&F in repairs of PCB sutable size for window / split AC complete all as specified and directed.
S&F in replacement of old unserviceable/sealed compressor unit from existing refrigerator of 310/300 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing incl flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance incl painting to complete body of refrigerator with two coats of synthetic enamel paint after preparation of dents complete all as specified and directed.
All as per Srl item No.13 here in before but for capacity of refrigerator 280 ltrs complete all as specified and directed.
All as per Srl item No.13 here in before but for capacity of refrigerator 165/175 ltrs complete all as specified and directed.
M & L Flushing out complete refrigeration system by nitrozen / CTC gas after deleting leakage and repairing tube/lines by brazing and charging the unit with compressor oil and refrigerant Gas-134 to its full capacity of refrigerator 300 lts capacity of any makeincl commissioning and testing for its smooth functioning complete all as specified and directed.
S&F rubber gasket of refrigerator door of any size and any make complete all as specified and directed.
Supply and replacement of thermostat switch of suitable size for any make and size of refrigerator complete all as specified and directed.
S&F in repairs for runnig capacitor of suitable size of refrigerator of any make and size complete all as specified and directed.
S&F in repairs for starting capacitor 40 MFD capacity complete all as specified and directed.
S&F in repairs for relay assembly suitable for refrigerator starting capacitor 40 MFD capacity complete all as specified and directed.
S&F in repair for over load protector suitable for refrigerator protector complete all as specified and directed.
Supply and replacement of freezer door of any make 310/300/286 ltrs size of refrigerators complete all as specified and directed.
All as per Srl item No. 23 here in before but size of refrigerator 165/175 ltrs complete all as specified and directed.
Repair to body of refrigerator of any size/capacity by welding of MS Sheet not less than 1.6 mm thich to match existing after receiving old rusted/unserviceable portion replacement of old nut bolt washers and hinges of top cover incl painting to complete body of refrigerator with two coat of synthetic enameled paint after preparation of surface and removing dentscomplete all as specified and directed.
S&F in replacement of old unserviceable/sealed compressor unit from existing deepfreezer of 300/310 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing incl flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance incl painting to complete body of refrigerator with two coats of synthetic enamel paint after preparation of dents complete all as specified and directed.
Supplying and fixing new legs set of 4 to put the refrigerator of any capacity/make in to vertical position including taking out the broken legs from the base of refrigerator complete all as specified and directed.
S&F in repairs for condensor unit suitable for deep freezer of existing size any capacity complete all as specified and directed.
M&L for repairing of voltage stablizer of any make and size of 2 KVA to 3 KVA by repairing/replacement of electric circuit and rewinding including insulating materials complete all as specified and directed.
S&F in replacement of old unserviceble sealed compressor from existing water cooler of any capacity of any make 120/60 and 150 ltrs storage capacity by cutting, replacing the same with new compressor from nanufacturer and re-connecting the replaced sealed comressor, unit to its original position of water cooler by brazing incl flushing out complete refrigeration system by applying/using CTC Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity after complete evacuating and cleaning the system reinstalling the water cooler at site and testing on full for its satisfactorily performance complete all as specified and directed.
All as per Srl item No.30 here in before but for capacity of water cooler 40/60 ltrs complete all as specified and directed.
Flushing out complete refrigeration system by CTC and repairing the leaking pipe/joints by refrigeration brazing and charging the unit with compressor oil and refrigerant gas after evacuating and flushing to its full capacity of any size and make of water cooler complete all as specified and directed.
S&F in repairs for condensor unit suitable for water cooler any capacity complete all as specified and directed.
S&F in repairs for running capacitor of suitable size of water cooler of any make and size complete all as specified and directed.
S&F in repairs for starting capacitor 80/100/120 mfd capacity complete all as specified and directed.
S&F in repairs for relay assembly 412Y/312Y complete all as specified and directed
S&F in repairs for over load protector suitable for water cooler protector complete all as specified and directed.
S&F in repairs for thermostat for water cooler complete all as specified and directed.
S&F in repairs rubber bedding gasket for any make and size of water cooler tank cover upto 25mm bore complete all as specified and directed.
Repair to body of water cooler of any size/capacity by welding of MS sheet not less than 1.6mm thick to match existing agter receiving old rusted/unserviceable portion, replacement of old nut bolt washers and hinges of top cover including painting to complete body of W/C with two coat of synthetic enameled paint after preparation of surface and removing dents complete all as specified and directed.
S&F Concussive pushbutton taps for water cooler of cast copper alloy 15mm, screwed for iron pipe and fixed complete all as specified and directed.
S&F in Replacement of PVC copper cable 2.5 sqmm multistrand three core complete all as specified and directed.
M&L for repairing of voltage stabilizer of any make and size of 0.5 KVA to 1 KVA by repairing/replacement of electric circuit and re-winding including insulating materials complete all as specified and directed.
Supply and Fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
M&L for 2 single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as an earth continuity conductor complete all as specified.
M&L for 2 single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as an earth continuity conductor complete all as specified.
M&L for complete overhauling of desert cooler of any size and make including replacement of perished wiring oiling and greasing the blower motor exhaust fan and water lifting/tullu pump including replacement of plastic unserviceable spares susch as ben, water distributor and PVC pipe including replacement of wood pads, preventing leakage if any by welding, painting of water tank with rubber seal of any approved make and testing the same for its smooth functioning complete all as specified and directed.
M&L for Desert cooler fan/ exhaust fans any type 230 V, AC sup, Single phase dismantling the cooler fan/ exhaust fans and taking out complete burnt winding from cooler fan motor and rewinding the same with super enameled copper winding wire of existing gauge and size incl throughly cleaning all the components of cooler fan, oiling and greasing painting with one coat of synthetic enamel paint after scrubbing and preparing the old painted surfaces & testing etc complete all as specified and directed.
M&L for two coats of painting for desert cooler cover a coat of red oxide primer including preparation of old surfaces on complete body of desert cooler of existing colour after removing dents and preparing surface complete all as specified and directed.
S&F in replacement of water lifting/tullu pump submersible type complete all as specified and directed.
S&F in replacement of wood wool for desert cooler of any size complete all as specified and directed.
Supply and fixing capacitor Dry type 4 MFD 230 volts for Exhaust/cooler fan of any type complete all as specified and directed.
Supply and Fixing of fan blade for Desert cooler of any type and any size complete all as specified and directed.
Supply and Fixing of fan blade for AC of any type and any size complete all as specified and directed.
Supply and Fixing of fan blade for water cooler of any type and any size complete all as specified and directed.
Supply and Fixing of fan blade for deep freezer of any type and any size complete all as specified and directed.
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan / sockets / power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & fixtures connected, and making good to disturbed surfaces of walls, floors filling up of holes, plastering white washing distempering etc matching to the existing etc. as directed.
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100 volts, drawn through & including concealed 20 mm rigid non metalic PVC conduit with all accessories fixed on wall/ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switches, switch sockets, sockets, regulators etc with 3 mm thick hylum laminated sheet cover including cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and as directed for:- NOTE: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza (c) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light / Fan point controlled by one way switch
One Bell /Buzzer point controlled by one way switch
One 3/5 pin 5 Amps socket outlet on independent board
One 3/5 pin 5 Amps socket outlet on same board
One light point controlled by two way switches
All as per Srl item No.58 here in before but with using copper conductor of 2.5 Sqmm for one 3/5 pin socket outlet 15 Amps on independent and using 2.5 Sqmm copper conductor as earth continuty cable
Supply and fixing switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
Supply and fixing socket out let sefty shutter 5 pin 5 Ampsflus type all as specified and directed.
Supply and fix bell push flush type 5 Amps complete all as specified and directed.
Supply and fixing switch piano flush type one way 15 Amps SP complete all as specified.
Supply and fixing socket outlet polycarbonate 2 in 1 , 3 pin 5 / 15 Amps flush type complete all as specified and directed.
S& F swicth flush type 5 Amps single pole two way complete all as specified and directed.
S&F switch modular flush button single pole one way 15 Amp complete all as specified and directed.
S&F socket out let 3 pin 5/15 Amp multipurpose, modular flush type 240 volt complete all as specified and directed.
M & L for replacement of Step regulator modular type for ceiling fan of any sweep complete all as specified and directed.
Supply and fix White cover plates with frame 3 Module complete all as specified and directed.
Supply and fix White cover plates with frame 4 Module complete all as specified and directed.
Supply and fix White cover plates with frame 8 Module complete all as specified and directed.
S&F for lamp holder insulated body of PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose 3 terminals PVC / Polycarbonate insulated body 65mmx 50mm size complete all as spcified and directed.
Supply and fixing bell ding-dong musical AC 230 Volts single pole complete all as specified and directed.
S&F Stepped type electronics fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V , AC recessed type with highefficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roofceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and directed.
Supply & fixing of recessed mounting luminaries with acrylic cover energy efficient decorative designed fixture with flat profile and electronic ballast suitable for 2x36W CFL and including 1x36 watt CFL 4 pin complete all as specified and directed. Make :- Bajaj cat Part No BCPA236CFLTDWEB2 or equivalent as approved by GE.
Supply and fix recess mounting LED driver luminar suitable for 36 watts complete all as specified and as directed. MAKE:Havells cat Part No LEDDRIVER36V36WS or equivalent as approved by GE.
Supply and fixing LED lights fitting 1x 20W, 220V, AC 4 feet decorative box type with driver, holder includingLED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete all as specified.
Supply and fixing LED light fitting mirror type withhigh out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fix in replacement wall mounted light fitting LED 10 watts with accessories including 01x10/9 watt LED bulb complete all as specified and as directed. Make - Havells cat No- LHFHCHE1TRW020 or equivalent as approved by GE.
Suppply and fixing submain wiring with using two single core 6.0 Sqmm copper multi-stranded conductor PVC insulated and unsheathed (FRLS) cable and one single core 6.0 Sqmm copper multistandred conductor PVC insulated and unsheathed (FRLS) Earth wire using ISI MArked IS 694 1100 volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade concealed PV C conduit ISI marked not less than 25 mm dia including conduit fitting and accessories complete including cutting cheses in existing wall of any descirption buiolt in ccement mortor and making good the disturbed surfaces in cement mortor (1:4) and finishing the surfaces to match with existing surfaces and finish termonatioin with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partition including clamping arrangement as required complete all as sepcified and directed .(Note:- Two Run of 6.0 Sqmm cable and one run of 6.0 sqmm earth wire in and including conduit of suuitable size shall be measured as one unit).
All as per item Ser No.82 here in before but with using copper conductor of 2.5 Sqmm and using 2.5 Sqmm copper conductor as earth continuty cable compete all as specified and directed.
All as per item Ser No.82 here in before but with using copper conductor of 4 Sqmm and using 4 Sqmm copper conductor as earth continuty cable compete all as specified and directed.
S&F PVC rectangular gang box multi purpose 5/15 Amps including making connections compete all as specified and directed.
Supply and replace Rigid PVC casing & capping 20/25 mm wide compete all as specified and directed.
S&F PVC rectangular gang box multi purpose 5 Amps including making connections compete all as specified and directed.
S&F socket out let 3 pin 5 amp multipurpose modular flash type compete all as specified and directed.
S&F switch 6 Amp modular flush type 240 volt one way compete all as specified and directed.
Material & labour for meter box made (sheet metal enclosure) out of MS sheet 2mm thick duly powder coated internall / externally with locking arragements, glass cover for taking meter reading, having sufficient working space and to accmodate these accessories:- (i). MCB Double pole 240 volt 63 Amps - 04 Nos (ii). Taking up/removal of existing energy meter and fixing the same meter box - 04 Nos
Supply and fixing LED street light fitting 35 Watt230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete with IP 65/66 protection compete all as specified and directed.
M & L for GI Bracket made out of 25 mm GI Pipe light grade 1.20 m length bend to shape including clamps, nuts bolt and washer and fixing to wall/ floor complete as directed.
S&F for MCB SP 6-32 Amps breaking capacity 10 KA 'C' series 240 volts 50 Hz complete all as specified and directed.
S&F for MCB SP&N 10 to 63 Amps breaking capacity 10 KA 'C' series 240 volts 50 Hz complete all as specified and directed.
S&F for MCB TPN 100 Amps breaking capacity 10 KA 'B' series 415 volts 50 Hz complete all as specified and directed.
S&F MCB distribution board double door sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 4 Ways complete all as specified and directed.
S&F double door MCB distribution board sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 8 Ways complete all as specified and directed.
S&F double door MCB distribution board sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 12 Ways complete all as specified and directed.
S&F vertical three phase distribution board including MCCB 4 pole 100 Amps as incomer with three phase and single phase TP/SP as outgoing complete with insulated bus bar arrangement IP 43 protection with metal door 4 way complete all as specified and as directed.
Taking down the Geyser of capacity 25 / 50 Ltr including disconnecting of electric / water supply connections from building for repair / replacement of defective components and overhauling / checking, servicing, des calling of inner tank, geyser element, checking of geyser assembly and setting of thermostat range complete and refixing the same after repair and testing including making electectric and water supply connection complete all as specified and directed. Note:- a) All safety precautions for the safety precautions for persons working during removal/fixing back of the Geyser shall be ensured by the contractor . Rates are inclusive of brazing of inner tank of copper for prevention of leakage and replacement of clamps nut bolts gasket set complete. b) Replacement of defective components, painting,etc., which shall be measured and paid for separately.
Supply and Fixing Heating element of capacity 2 kW (cap type / triangular / threaded type), ISI marked, suitable for geyser of capacity 50Ltr complete all as specified and directed.
Supply and Fixing Heating element of capacity 1.50 KW (cup type), ISI marked, suitable for geyser of capacity 25Ltr complete all as specified and directed.
S&F in replacement of neon Indicator lamp of red and green colour lamps suitable for geyser of capacity 25/ 50 Ltr of any type / make complete all as specified and directed.
S&F in replacement of Thermostat assembly 16 A,240 AC, ISI marked, suitable for geyser of capacity 25/ 50Ltr of any type / make complete all as specified and directed.
S&F in replacement of PVC Helical (Hot / Cold) water connection pipe of size 450 mm x 15mm dia with two no of brass nut on each side for geyser complete all as specified and directed.
S&F in replacement of bottom plate of geyser in two pices including painting of approved colour suitable for 25/50 ltr capacity geyser as per original pattern and as approved by Engineer in charge complet all as specified and directed.
S&F in replacementof (4 nos) ,16 mm dia nuts bolts of suitable length duly grouted in walls in cement mortar for fixing of geyser of any capacity complete all as specified and directed.
Taking out damage glass wool from the geyser and supply fix glass wool all around the inner tank of geyser for maintaining the required temperature complete all as specified and directed.
S&F in replacement of Gun metal Non return valve (NRV) of size 15 mm bore ISI marked complete all as specified and directed.
S&F in replacement of stop valve fancy type cromium plate high pressure surface concealed with crutch of butter fly handle screwed both ends for iron pipe 15 mm bore ISI marked complete all as specified and directed.
M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt).
Taking down ceiling fans 48”/56” sweep, cleaning of dust properly cleaning, greasing& overhualing of bearings including refixing and connecting up all as directed .
Supply and fix in repairs 2.50 Mfd capacitior complete all as specified and as directed.
Supply and fix in repairs 3.15 Mfd capacitior complete all as specified and as directed.
Supply and fix in repairs 4.00 Mfd capacitior complete all as specified and as directed.
Supply and fix in repairs ball bearing suitable for exsiting ceiling fans on site complete all as specified and as directed.
Supply and fix in repair ‘U’ clamps complete with nut, bolts & split pins Heavy duty suitable for existing ceiling fan complete all as specified and as directed.
Supply and fix in repair M.S. rod for ceiling fans 3 ft long with ‘U’ clamp at one end other end with out nut bolts washers or screwed thread with check nuts & pin complete all as specified and as directed.
Material and labour for rewinding of burnt fan motor with super enameled copper wire of suitable size 1200/1400mm sweep ceiling fan of any make, type, model including transporation (inclusive of material & labour) complete all as specified and as directed
Taking down exhaust fans 250/300 mm Sweep and cleaning the dust properly, oiling, greasing & overhualing and replacement of defective, born out parts of bolts and bearings including refixing and connecting up all as directed Note : Replacement of defective/worn out parts will be measured & paid for separately
Taking down exhaust fans 400/450 mm Sweep and cleaning the dust properly, oiling, greasing & overhualing and replacement of defective, worn out parts of bolts and bearings including refixing and connecting up all as directed Note : Replacement of defective/worn out parts will be measured & paid for separately
Supply and fix Ball bearings suitable for existing exhaust fans as per site complete all as specified and directed.
Supply and fix copper alloy Bush suitable for existing exhaust fans as per site complete all as specified and directed.
Material and Labour for rewinding of exhaust fans 250/300 mm Sweep with super enameled copper wire of suitable size of any make/type/model including transporation complete all as specified and directed.
M&L for Desert cooler any type 230 V, AC sup, Single phase dismantling the cooler fan and taking out complete burnt winding from cooler fan motor and rewinding the same with super enameled copper winding wire of existing gauge and size incl throughly cleaning all the components of cooler fan, oiling and greasing painting with one coat of synthetic enamel paint after scrubbing and preparing the old painted surfaces & testing etc complete all as specified and directed.
M&L for two coats of painting for desert cooler cover a coat of red oxide primer including preparation of old surfaces on complete body of desert cooler of existing colour after removing dents and preparing surface complete all as specified and directed.
M&L for rewinding of exhaust fans 400/450 mm Sweep with super enameled copper wire of suitable size of any make/type/model including transporation complete all as specified and directed.
Supply and replace wire of Flexible cord with copper conductor multistanded of twin core 23/0.198 complete all as specified and directed.
S&F in replacement PVC copper wire of 1.5 sq mm, 1100 volts, multistandred conductor PVC insulated and unsheathed (FRLS) complete all as specified and directed.
M/S CHAUHAN ELECTRIC WORKS
UTTRAKHAND BUILDERS
M/S SHAHABUDDIN AND SONS
avon electric engineering woks
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .