Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC 1ST FLOOR OPP GURUDWARA GURUDWARA ROAD BENACHITY DURGAPUR 713213 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | 713213 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.7 L+₹459.75 (0.10%)Rejected-Finance 3A SOURENDRA MOHAN GHOSH SARANI MANGOE LANE KOLKATA 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Due to 2nd quoted rate | |
| 3 | L3₹4.7 L+₹1,329.55 (0.28%)Rejected-Finance 41 D H 58 BB GHOSH SARANI KOLKATA 700067 | KOLKATA | KOLKATA | WEST BENGAL | 700067 | L3 | Rejected-Finance Due to 3rd quoted rate |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
26 Jul 2021, 11:00 amClosed
Executive_Engineer_MSD_DIVN_PHE_Dte
4,_C.R.Das_Road_Berhampore_Murshidabad. 742101
Providing service by assigning Resource Person for a period of 3 months supervision of process of preparation for NABL recognition for Chemical Testing of potable water of Domkol Mechanical Sub-District Water Quality Testing Laboratory including
2021_PHED_336016_4
WBPHED/EE/MSD/NIeQ/07/2021-22
Open Tender
SUPPLY OF CIVIL GOODS/EQUIPMENTS
Lump-sum
10 days
Berhampore_Murshidabad
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
22 Jan 2025
9 Jul 2021
28 Jul 2021
9 Jul 2021
26 Jul 2021
9 Jul 2021
Amount
Rendering Training and awareness generation of ISO/IEC: 17025: 2017 protocol deputing Resources person for supervision and hands on training on analysis of 11 mandatory parameter for NABL recognition through NABL GAP android apps Providing service by assigning Tecinical resource team for supervision of NABL recognition (Chemical Testing of potable water) of Block level Water Testing Laboratory under PHE Dte, as per below scope details: Training to the Lab personnel on overview of NABL accreditation as per ISO/IEC 17025:2017 and recognition Guidelines for Laboratory Setup (Standard Instrument, enhancing manpower competency, Standard reference materials, mode of calibration of different instruments) and as per requirement of NABL recognition. To conduct consolidated Refresher hands-on training on chemical parameters testing and standardization procedure related to mandatory 11 parameters as per requirement of NABL recognition. To supervise and assist for preparation & record of General Documentation to set up a brief Laboratory operation system management to achieve the requirement of NABL recognition including Reviewing and Up-dating of Documents of Test Procedure & Records Reviewing and Up-dating of Test Procedure & risk analysis To supervise and assist for preparation & record of Technical Documentation as per requirement of NABL recognision protocol To supervise and assist for preparation & record of Proficiency Testing & the related Technical Documentation for NABL recognition
Supply, Installation and traing on calibration & operation of all measuring equipment Calibration of all measuring equipment and certificate from NABL accredited calibration laboratory Viz. Analytical Balance, F1 class Weight Box, , Burettes, Pipettes of different volume, Volumetric Flask of different volume, measuring cylinder of different volume, Thermometer, all digital indicator & any other measuring Instruments with traceability certificate as required for NABL GLAP web based application
Supply of F1 Class Analaytical Certified (as per ISO-17025 requirement) standard weight Box with fractional weight TX-F1-1500- SHI-AM
Microprocessor based digital, portable Total Dissolved Solid-Temperature meter, with 5-point cabibration facility, auto calibration standard recognition facility, Up to ±1 % full scale accuracy, Measuring range: to 9.99 ppm *, 10.0 ppm to 99.9 ppm, 100 ppm to 999 ppm, 1.00 ppt to 9.99 ppt, 10.0 ppt to 99.9 ppt, Auto temperature compensation facility, with hold & auto off function, complete with Total Dissolved Solid sensor, batteries, carrying kit, 300 ppm calibration standard for drinking water
Supply of Publication of BIS for IS 3025: Part nos: 4, 5, 8, 10, 11, 16, 21, 23, 40, 32, 46,
HTC Instrument - Digital Indoor Outdoor Hygro Thermometer with Clock
High Accuracy Digital Temperature sensor with probe-
Thermometer 10/50 LC:0.5
Thermometer 10/100 LC:0.5
Supply delivery of Standard reference material required ragents for 11 mandatory parameters, Certified Galssware and sundry items in connection with NABL recognition through NABL GLAP android apps pH Buffers - 25°C : Clear, Colourless pH Buffer Solutions. Tested at 25°C and certified by Reagecon's ISO 17025 accredited test method. NIST traceable, pH: 4.00 ±0.01@25°C in 500 ml
pH Buffers - 25°C : Clear, Colourless pH Buffer Solutions. Tested at 25°C and certified by Reagecon's ISO 17025 accredited test method. NIST traceable, pH: 7.00 ±0.01@25°C in 500 ml
pH Buffers - 25°C : Clear, Colourless pH Buffer Solutions. Tested at 25°C and certified by Reagecon's ISO 17025 accredited test method. NIST traceable, pH: 10.00 ±0.01@25°C in 500 ml
Sodium carbonate volumetric standard, secondary reference material for acidimetry, traceable to NIST SRM
Calcium carbonate volumetric standard. secondary reference matenal for complexometry, traceable to NIST Standard Reference Material (SRM)
Sodium chloride volumetric standard, SRM for argentometry, traceable to NIST
Turbidity Standard Non Ratio, 1000 NTU, certified by ISO 17025 Accredited test Method. NIST traceable, 500 ml
Potassium Chloride, CRM, NIST Traceable, 5 gm
Potassium Chloroplatinate, 1 gm
Cobalt Chloride,AR ACS 100 gm
Hydrochloric Acid 37%, 500 ml
Sulfuric Acid about 98%, 2000 ml
Phenolpthelein indicator
Methyl Red indicator
Bromocresol Green indicator
2-Propanol (Iso propyl Alcohol)
EDTA Disodium salt (Titriplex-III), 100 gm
Ammonia Solution 25%, 1000 ml
Ammonium Chloride , 500gm
Magnesium Sulfate, 500 gm
Ammonia Buffer ready to use solution, 500 ml
Hydroxylamine Chloride, 100 gm
Erichrome Black-T, 25 gm
Triethanolamine, 500 ml
Sodium Hydroxide 1N, 2 amp
Hydrochloric Acid 0.1N, 500 ml
Murexide (5,5’-Nitrilobarbituric Acid Monoammonium Salt) for analysis EMPARTA® ACS, 5 gm
Potassium Chloride analytical grade, 500 gm
Nitric Acid 69%, 500 ml
Ethanol, 500 ml
Silver Nitrate analytical grade 25 gm
Potassium Chromate analytical grade assay min: 99.5%, pH of 5% soln : 9.02-9.8, 500 gm
Water for Chromatography, 1 lit pk
Nessler Cylinder, for colour comparison graduated as per IS 4161 : 1967.
Beaker 250 ml, Borosilicate glass
Beaker 100 ml, Borosilicate glass
Conincal Flask 250 ml, Borosilicate glass
Wide mouth Borosilicate Glass bottle 1000 ml with glass stopper
Volumetric Flask Class A, certified as per ISO 17025 requirement set of 6, Cap:100 ml
Volumetric Flask Class A, certified as per ISO 17025 requirement set of 2, Cap: 500 ml
Volumetric Flask Class A, certified as per ISO 17025 requirement set of 2, Cap: 1000 ml
Burette, Class A, certified as per ISO 17025 requirement set of 4, Cap: 50 ml, Glass
Pipette Graduated Mohr type, Class A, certified as per ISO 17025 requirement set of 6, Cap: 1 ml/0.01 div
Pipette Graduated Mohr type, Class A, certified as per ISO 17025 requirement set of 6, Cap: 5 ml/0.05 Div
Pipette Graduated Mohr type, Class A, certified as per ISO 17025 requirement set of 6, Cap: 10 ml/0.1 Div
Pipette Graduated Mohr type, Class A, certified as per ISO 17025 requirement set of 4, Cap: 25 ml/0.2 Div
Volumetric Pipette Class A, certified as per ISO 17025 requirement set of 2, Cap: 5 ml
Volumetric Pipette Class A, certified as per ISO 17025 requirement set of 2, Cap: 10 ml
Measuring Cylinder Class A, certified as per ISO 17025 requirement 100 ml
Beaker PP, set of 12, Cap: 50 ml,
Wash Bottle set of 6, Cap:500 ml PP
Burette Stand- with single burette clamp, PP coated, set of 2
Nitrile Gloves, pk of 100 nos
Safety Googles, pk of 2 nos
Sub Total=
Add @ 18 % GST of Total (A)=
Total=
Add @ 1 % CESS of Total (B) =
BHARATI CHEMICAL AND SCIENTIFIC WORKS
NATURAL RESOURCES CONSORTIUM
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .