Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC VILL SINGIMARI PO KALAIGAON DIST UDALGURI ASSAM | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 Cr+₹6,100 (0.04%)Rejected-AOC KOKRAJHAR WARD NO 8 P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹1.4 Cr+₹6,100 (0.04%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.4 Cr+₹11,560 (0.08%)Rejected-AOC WARD NO 3 GOSSAIGAON P O P S GOSSAIGAON DIST KOKRAJHAR BTC ASSAM PIN 783360 | GOSSAIGAON | KOKRAJHAR | ASSAM | 783360 | ₹1.4 Cr+₹11,560 (0.08%) | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Smt Guni Brahma L2 | LWITHW NARZARY L3 | PANKAJ DEBNATH L1 |
|---|---|---|---|---|---|---|
| 1.00 | 16.78 Labour for taking out old piles of timber bridge with necessary scaffolding, jati bamboos, jumper ropes etc, complete and stacking them at suitable places as directed. | 30 | Each | 1,675.1 ₹50,253 | 1,676.1 ₹50,283 | 1,674.1 ₹50,223 Lowest |
| 2.00 | 16.79 Labour for dismantling all members of the timber bridge (excluding piles) with necessary scaffolding, jati bamboos, jumper ropes etc, complete and stacking them at suitable places as directed (all members will be under custody of the contractor till taken over by the department) | 22 | Rm. | 1,340.86 ₹29,498.92 Lowest | 1,340.86 ₹29,498.92 Lowest | 1,340.86 ₹29,498.92 Lowest |
| 3.00 | 17.4 Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
(I) Ordinary soil
(A) Manual Means
(I) Without dewatering
(i) upto 3 m depth | 211.88 | Cum. | 145 ₹30,722.02 | 148 ₹31,357.65 | 137.86 ₹29,209.23 Lowest |
| 4.00 | 17.27 Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm) | 347.68 | m | 11,498 ₹39,97,624.64 | 11,499 ₹39,97,972.32 | 11,495.49 ₹39,96,751.96 Lowest |
| 5.00 | 17.40 Levelling course for Pile cap | 7.94 | Cum. | 5,821.76 ₹46,242.24 Lowest | 5,821.76 ₹46,242.24 Lowest | 5,821.76 ₹46,242.24 Lowest |
| 6.00 | 17.37 Pile load test on single vertical pile in accordance with IS:2911(Part-IV).
(a) Initial and Routine load test. | 102 | tonne | 372.9 ₹38,035.8 Lowest | 372.9 ₹38,035.8 Lowest | 372.9 ₹38,035.8 Lowest |
| 7.00 | 17.38 Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification.
(B) RCC grade M25
(i) Using concrete mixer. | 125.13 | Cum. | 7,469.3 ₹9,34,633.51 Lowest | 7,469.3 ₹9,34,633.51 Lowest | 7,469.3 ₹9,34,633.51 Lowest |
| 8.00 | 17.41 Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications.
(a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) | 30.49 | tonne | 64,120.72 ₹19,55,297.24 Lowest | 64,120.72 ₹19,55,297.24 Lowest | 64,120.72 ₹19,55,297.24 Lowest |
| 9.00 | 17.46 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork
(N) Without Plasticiser
(F) RCC grade M25
(a) Height upto 5 m
Case I : Using concrete Mixer | 66.41 | Cum. | 7,939.38 ₹5,27,254.23 Lowest | 7,939.38 ₹5,27,254.23 Lowest | 7,939.38 ₹5,27,254.23 Lowest |
| 10.00 | 17.47Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications
(a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) | 5.5 | tonne | 64,274.4 ₹3,53,444.93 Lowest | 64,274.4 ₹3,53,444.93 Lowest | 64,274.4 ₹3,53,444.93 Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
19 Jan 2026, 2:00 pmClosed
The Addl. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar.
Construction of CC Br. No. (1 1) at Makenji road to Rupatal under SOPD (BTC) in Udalguri District for the year 2023-24.
2025_BTC_49701_4
ACE-25/PWD/IFB/BTC/2025-26/45
Open Tender
Civil Works
Item Rate
365 days
Udalguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,800
₹2.8 L
Yes
6 Aug 2026
29 Dec 2025
20 Jan 2026
29 Dec 2025
19 Jan 2026
29 Dec 2025
29 Dec 2025 - 19 Jan 2026
16.78 Labour for taking out old piles of timber bridge with necessary scaffolding, jati bamboos, jumper ropes etc, complete and stacking them at suitable places as directed.
16.79 Labour for dismantling all members of the timber bridge (excluding piles) with necessary scaffolding, jati bamboos, jumper ropes etc, complete and stacking them at suitable places as directed (all members will be under custody of the contractor till taken over by the department)
17.4 Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. (I) Ordinary soil (A) Manual Means (I) Without dewatering (i) upto 3 m depth
17.27 Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)
17.40 Levelling course for Pile cap
17.37 Pile load test on single vertical pile in accordance with IS:2911(Part-IV). (a) Initial and Routine load test.
17.38 Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification. (B) RCC grade M25 (i) Using concrete mixer.
17.41 Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
17.46 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (N) Without Plasticiser (F) RCC grade M25 (a) Height upto 5 m Case I : Using concrete Mixer
17.47Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
17.50 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification (a) Granular Material
17.49 Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
17.58 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (N) Without plasticiser (B) RCC grade M25 Case I : Using Concrete mixer (i) For solid slab super-structure (a) Height upto 5m
17.59 Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
17.61 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
17.64 Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
17.77 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
17.67 Drainage Spouts complete as per drawing and Technical specification
17.68 PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
17.69 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
17.71 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (b) for RCC Railing
PROTECTION WORK 14.5 Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 (i) Stone/Boulder
14.6 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
14.2 Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
APPROACH ROAD 2.2 Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (I) By Manual Means (a) In area of non thorny jungle
3.4 Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
3.14 Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
4.1 Granular Sub-base with Well Graded Material (Table 400.1) Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method (ii) For Grading II Material
4.7 Water Bound Macadam Sub-base/base (III) WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
6.7 Inter locking concrete Block pavement (A) Interlocking pavement block (i) Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. (a) Including Edge block/ Edge restraints
16.70 Construction of cold weather Bamboo bridge overall width of 3.70m and clear road way 3m with jungle wood post 20cm to 25cm dia 5nos. In each rows and rows being 2.1m. apart except for the navigable span which should be 3m. Post to be driven at least 180cm. or more below ground level including providing 20cm to 25cm center to center and placed over 20 cm dia, jungle wood dham, 15cm dia. jungle wood bracing collar fixed by bolts and nuts, straps etc. mature bholuka Bamboo cross groth all closely packed and tied 75cm wide track way made from 38mm thick 1st class local plank fixed on 75mmx100mm first class local wood battens 120cm apart and 3 lines of jati bamboo horizantal railing fixed in bholuka bamboo post placed at 210cm apart and white washed including all necessary nuts and bolts, coir ropes, struts, nails etc. complete with a layer of brushwood to exposed portion out-side trackway with earth topping complete as per direction of the department.
16.36 Metal Beam Crash Barrier, Type - A: "W" Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m center to center, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanized by hot dip process, all fitting to conform to IS:1367 and IS:1364, metal beam rail to be fixedon the vertical post with a spacer of channel section 150mm x 75mm x 5mm, 330mm long complete as per clause 810.)
10.2 Traffic Signs (A) Retro-reflectorised Traffic Signs (I) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (ii) 600mm equilateral triangle
10.16 Providing and Fixing 'Logo' of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.83 MB
SBD.pdf
Tender Documents • 13.50 MB
BOQ_78966.xls
BOQ • 0.27 MB
FOB.pdf
Additional Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .