Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC POST OFFICE ROAD DHARMANAGAR DHARMANAGAR NORTH TRIPURA | NORTH TRIPURA | TRIPURA | 799250 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical SHIBNAGAR AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799001 | - | Rejected-Technical expereince not qualified |
| Sl No | Description | Qty | Unit | NIKHIL DAS L1 |
|---|---|---|---|---|
| 1.00Supply of the fillowing: | ||||
| 2.00 | Steel Tubular Pole 8 m long | 8 | Nos. | 10,000 ₹94,400 Lowest |
| 3.00 | Steel Tubular Pole 9 m long | 10 | Nos. | 12,000 ₹1,41,600 Lowest |
| 4.00 | PVC CABLES (SINGLE CORE) 70 mm2 | 0.04 | KiloMeter- km | 70,000 ₹3,304 Lowest |
| 5.00 | XLPE CABLE (HT) 3Cx95 sq.mm | 1.8 | KiloMeter- km | 7,50,000 ₹15,93,000 Lowest |
| 6.00 | Rewireable Porcelain Cut out 300 Amp | 3 | Nos. | 1,400 ₹4,956 Lowest |
| 7.00 | 11KV Polymer Pin Insulator | 30 | Nos. | 200 ₹7,080 Lowest |
| 8.00 | L.T. Stay insulator | 5 | Nos. | 30 ₹177 Lowest |
| 9.00 | 11 KV Stay insulator | 4 | Nos. | 40 ₹188.8 Lowest |
| 10.00 | LT Shackle Insulator (3x 3.5)" | 60 | Nos. | 30 ₹2,124 Lowest |
Tender Value
₹36.0 L
EMD Value
₹72,030
Closing Date
21 Jul 2025, 12:00 pmClosed
the DGM, ED-Kumarghat
O/o the DGM, ED-Kumarghat
Extension of HT/LT line for providing 3 (three) phase service connection to the Establishment of Modern Abattoir for pig cum pork processing plant construction at Karaicherra, Machmara under ESD-Pecharthal
2025_POWER_63491_1
DGM/ED/KGT/2025-26/02
Open Tender
Electrical Works
Turn-key
under ED-Kumarght
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹72,030
18 Sept 2025
8 Jul 2025
21 Jul 2025
8 Jul 2025
21 Jul 2025
11 Jul 2025
8 Jul 2025 - 10 Jul 2025
Amount
Supply of the fillowing:
Steel Tubular Pole 8 m long
Steel Tubular Pole 9 m long
PVC CABLES (SINGLE CORE) 70 mm2
XLPE CABLE (HT) 3Cx95 sq.mm
Rewireable Porcelain Cut out 300 Amp
11KV Polymer Pin Insulator
L.T. Stay insulator
11 KV Stay insulator
LT Shackle Insulator (3x 3.5)"
11KV Gang Operated Switch (Polymeric type)
LIGHTINING ARRESTOR 9 KV, 5KA Polymeric L/A
Stay set complete
GI Stay wire stranded stay wire 7-4mm
8SWG GI Wire
M.S. ANGLE (65x65x6) mm Angle
M.S. CHANNEL (75x40x40x6) mm Channel
Straps with Nuts Bolts
11 KV Drop out Switch DOF Polymeric 3ph
Aluminium Lugs 95mm sq
Errection of the followings:- Supply of M.S.Nuts & Bolt i/c Washer of assortedsize ISI Marked machine made
Providing of Pre-cast cement concretecableidentification route marker (1 cement: 2 coarse sand4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker snail be embossed "DANGERS: TSECL, ELECTRIC POWER CABLE” with Black colour letter {both side) The visible part shall be painted with Yellow colour japan paint. (1 cement: 2 coarse sand 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits.
Supply of 2.5mtr. Long , 40mm dia G.I.Pipe Make: TATA/ JINDAL)
Supply of 60Kg Salt & 55Kg Charcoal ( For 1 Pit).
Grouting of Steel Tubular PCC Pole of ratio 1:2:4 (1cement:2 riversand:4 Jhama brick Aggregate of 20mm. Nominal size) including supply of cement, sand and brick aggregate. Complete with excavation, refilling of each, ramming along with centering and shuttering as required
Supply Erection of S/S Fencing as per Specification
110 mm dia, Wall thickness: minimum-6.5mm, maximum- 7.3mm
Supplying and Making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as requiredUp to 150sqmm
Civil work for construction of Transformer base and Fencing of Hard drawn steel wire fabric as per requirement and direction of Engg. In Charge
Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Trench Size: Width-350mm, Hieght- 1200mm / Sand(couhioning): Hieght-250mm, Width- 350mm/Protection: Double layer BricksUpto 120 sq. mm
UGD155: Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :Up to 95sqmm
Coiling of excess Single/3core/3/z Core, upto to 400sqmm, HV/MV, XLPE insulated, armoured power Cable direct into earth including excavation of earth upto a depth of 1500mm (Size pit should be 2250mmX2250mm or as per site requirement.) including 1st class bricx protection of two layer f(at brick soling 300 mm. Fine sand (Local quary) for cushioning/bed and refilling and ramming the excavated soil as per direction of Engineer in charge.
Erection of Stay set direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp,Nuts & Bolts etc. as required. and making complete in all respect
Erection of M.S.Angle Cross-Arm bracket of 2 wire upto 1100Mtr. Long of 50 x 50 x6mm/ 65x65 x 6 mm
Erection of M.S.Angle Cross-Arm,1.0 to 2.5 Mtr.Long 65 x65 x 6 mm ( Excluding the cost of BackClamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,1.3 to 2.8 Mtr.Long75 x40 x 40 x 6 mm ( Excluding the cost ofBack Clamp, Nuts & Bolts)
Erection of 11KV Pin insulator along with Pin.
Earthing with G.I pipe 2.5mtr. Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.I.Pipe, Salt & Charcoal, Gi wire, nuts &boIts, etc. as required)
Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode
Erection of protective Guarding/Cross lacing for 415/240VoIt line BY GI wire 98/10SWG as per technical specification,across road/River/Telecom line etc. in horizontal/Verticle formation complete with Spool/Reel insulator.
Febrication of Cross-Arms by MS Channel/MS Angle as per specification
Laying and Stringing of 1KM (Single Conductor) ACSR 6/1/2.59 mm dia WEASEL including hoisting and binding etc. Complete as required.
Laying & strining of 1KM (Single Conductor)10/8SWG GI wire including hoisting & binding etc. Complete as required
Erection of 9KV,5KA single pole metal oxide gapless type LA , including necessary connection complete as per technical specification
Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification.(Excluding the cost of back clamp, Nuts & Bolts)
Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification. (Excluding the cost of back cIamp,Nuts & Bolts)
Installation/Positioning of 11/0.430KV,3-Phase 200KVA to 250KVA of Distribution Transformer on Pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing.
Providing Three Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35mtr. in length supported by G.I.Wire,Reel Insulator i/c fitting fixing of Energy Meter as required
Erection of 8.0mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Erection of 9.0mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 11 KV grade of all size in the GI Pipe/HDPE for riser including tieup ofPipe with pole by the help MS Flat Clamp (excludingcost of Clamp and Nut&Bolts) as requiredUp to 400 sq. mm
Erection of shackle insulator of size 75mm x 90mm/100mm x 15mm with straps & bolts/U clamp on poles ( Excluding the cost of cost of straps/ U Clamp, Nuts & Bolts)
Supply of febricated clamps of assorted size of MS flat (50 x 6 mm) with double coat of red oxide primercoating
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .