| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-Finance | ₹3.5 L | L1 | Accepted-Finance L1 |
| 2 | L2₹3.5 LRejected-Finance RAJAPUR ULUBERIA HOWRAH | HOWRAH | WEST BENGAL | 711101 | ₹3.5 L | L2 | Rejected-Finance L2 |
| 3 | L3₹3.5 LRejected-Finance | ₹3.5 L | L3 | Rejected-Finance L3 |
| 4 | L4₹3.5 LRejected-Finance VILL UTTAR TALDI P O TALDI SOUTH 24 PARGANAS | KOLKATA | WEST BENGAL | 700070 | ₹3.5 L | L4 | Rejected-Finance L4 |
| 5 | L5₹3.5 LRejected-Finance ARABINDANAGAR ALIPURDUAR COURT | ₹3.5 L | L5 | Rejected-Finance L5 |
Tender Value
₹3.5 L
EMD Value
₹7,022
Closing Date
3 Feb 2026, 11:00 amClosed
AE, BNWSD-II
Office of the Assistant Engineer, Bidhannagar West Sub-Division-II, Salt Lake, Sec-I, Kolkata 700091.
Urgent repair of Roof Shed Wall and Ceiling of CEO Office Area BTTA within the compound of V Y B K during the year 2025 26
2026_WBPWD_990986_6
NIeT-21/AE/BNWSD-II of 2025-2026
Open Tender
CIVIL WORKS
15 days
SALT LAKE
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,022
Yes
16 Feb 2026
19 Jan 2026
5 Feb 2026
19 Jan 2026
3 Feb 2026
19 Jan 2026
Dismantling worn out wall or ceiling of Tarja or Durmamat and removing the dismantled materials as directed.
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For trusses spanning up to 12.00 m.
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar. (b) 20 mm thick plaster.
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall. With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m. (i) Coloured decorative.
(b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats.
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality.
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters (single leaf).
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor. Glossy/Matt/ Suede excluding surface texture or metallic lustre. (i) Thickness of laminate 1.5mm.
i) Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete. (b) Medium type (I.S.I. size 2).
(a) Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
P.V.C- False Ceiling : Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide. PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineer-in-Charge . In ground floor.
Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the "W‟ profile (0.55 mm thick ) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the "W‟ profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of Engineer-in-Charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish. b) 6 mm thick Designer Multipurpose Cement board (High Pressure steam cured, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7&8, density > 1450kg/m3, Bond strength 15 N/sqmm fire resistant, termite proof, moisture resistant) reinforced with cellulose fibre manufactured through autoclaving process as per IS : 14862 & ISO 8336, with fibre cement screws in partition as per drawings and direction of Engineer-in-Charge complete. (The above stated item can be used successfully to cover up efflorescence & damp affected walls to improve the aesthetic view).
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required. Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials, labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse).
B) Supplying & laying of approved make and brand of scratch proof, flexible & homogeneous P.V.C. Vinyle flooring conforming to IS:3462 - 1982 in required finish, fixed with synthetic acrylic adhesive after preparing the floor, levelling & smothaning when necessary with suitable putty, as per the design & instruction of the Engineer-in-charge. (i) 2 mm thick (Plain).
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. a) 25 mm thick Tiles as per IS: 1237-2012 for footpath, ramp, staircase of public building(over 25 mm thick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block. Cement for Mortar & Slurry to be supplied by Department). (ii) Coloured Decorative.
stage.html
html • 0.11 MB
tech_eval.pdf