Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹49.5 L
EMD Value
₹98,900
Closing Date
17 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
SERVICING AND MAINTENANCE OF DISTRIBUTION TRANSFORMER DEHYDRATION TOPPING UP AND ATTENDING BREAKDOWN 24 HRS WITH OTHER MISC WORKS OF TRANSFORMERS AT OLD DOCKYARD MARINE SUBSTATIONS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2026_MES_795927_1
8709/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹500
GE (I) DM Visakhapatnam
₹98,900
Yes
27 Oct 2026
27 Oct 2026
19 Nov 2026
27 Oct 2026
17 Nov 2026
10 Nov 2026
28 Oct 2026 - 8 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Attending to transformer complain 24 hrs of capacity upto 1250 KVA tripping including meggaring of the cables and checking the physical condition of the transformer and assessing the physical condition and, checking oil level, conducting electrical LT testing like, measuring of IR values, ratio test, magnetic balance test, oil BDV test to assess the healthness of the windigs and if found statiafactory, then connections of the cable terminations and make arrange for charging the transformer.If transformer is found faulty, then recommend for the further repair/rewinding works to be carried out to put back the transformer into serviceall as specified and directed. | 30 | Each Job | - | - |
| 2 | All as per item No. 1.00 above, but for transformer capacity 1500 KVA to 3000 KVA, 11/0.415 KV | 16 | Each Job | - | - |
| 3 | Overhauling of transformers of capacity upto 1250 KVA openning of top cover in situ or at wksp by unscrewing all nuts, bolts & washers, draining out transformer oil upto required level and keeping in clean container for repair/replacement of HT/LT bushings, tap changer, physical check of any defects, for lifting of core assy, for cleanning/repair and refixing top cover complete with RC 70 C rubberised cork sheet gusket sheet , existing/new nuts, bolts & washers for transformer indoor/outdoor type,The transformer to be put inside the hearting chamber for IR values imporvement, refilling of oil for transformer all as specified and directed.
Note:- (a) HT/LT bushings, Studs, tap changers, nuts, bolts & washers required new shall be mesured separately here-in-after (b) Silicon oil proof gusket shall be inclusive of quoted rate. (c) Transportation and loading and unloading charges to be measured and paid included. | 5 | Each Job | - | - |
| 4 | All as per item No. 3.00 above, but for transformer capacity 1500 KVA to 3000 KVA, 11/0.415 KV | 8 | Each Job | - | - |
| 5 | M & L for filtration/dehydration transformer oil of transformer voltage grade 11/0.415 KV, capacity 200 KVA to 3000 KVA indoor/outdoor type, floor mounted in situ till achieve dielectric strength minimum 40 KV at 4mm gap all as specified and directed. | 40,000 | Ltr | - | - |
| 6 | M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 40 KV at 4mm gap complete all as specified and directed. | 4,200 | Ltr | - | - |
| 7 | Supply only transformer Epoxy bushing outdoor/indoor type suitable for 11 KV grade complete of transformer capacity 500KVA to 1250 KVA, 11/0.415 KV transformer complete all as specified and directed. (Transformer bushings shall be compitable model with make and model of existing transformer) | 12 | Each | - | - |
| 8 | All as per item No. 7.00 above, but for transformer capacity 1500 KVA to 2500 KVA, 11/0.415 KV | 15 | Each | - | - |
| 9 | Supply only transformer Epoxy bushing outdoor/indoor type suitable for 1100 volts grade complete of transformer capacity 500KVA to 1250 KVA, 11/0.415 KV transformer complete all as specified and directed. (Transformer bushings shall be compitable model with make and model of existing transformer) | 9 | Each | - | - |
| 10 | All as per item No. 9.00 above, but for transformer capacity 1500 KVA to 2500 KVA, 11/0.415 KV | 12 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_892703.xls
BOQ • 0.40 MB
8709Tender.pdf
Tender Documents • 0.98 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .