| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | ₹34.4 L Quoted ₹35.6 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹36.7 L+₹1.1 L (3.04%)Rejected-Finance | ₹36.7 L+₹1.1 L (3.04%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹36.7 L+₹1.1 L (3.21%)Rejected-Finance | ₹36.7 L+₹1.1 L (3.21%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹37.3 L+₹1.7 L (4.73%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | ₹37.3 L+₹1.7 L (4.73%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹38.3 L+₹2.7 L (7.65%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | ₹38.3 L+₹2.7 L (7.65%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
4 Jul 2023, 6:00 pmClosed
Shri Prahalad Meena, Offg Garrison Engineer
GE Navy Porbandar Tija Mile Porbandar
SPECIAL REPAIR TO BUILDING NO. P-11 AT NAUVEER NAGAR OKHA UNDER GE NAVY PORBANDAR
2023_MES_594492_2
8825/Okha/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹76,000
Yes
18 Jul 2023
19 Jun 2023
6 Jul 2023
19 Jun 2023
4 Jul 2023
27 Jun 2023
19 Jun 2023 - 26 Jun 2023
Amount
Taking down cement or cement plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc. to receive new plaster complete all as specified.
M&L Rendering 15 mm thick in CM 1:6 on surfaces or surface other than fair face of brick-work or on one side of lathing of stone masionary or concrete surfaces finished even and smooth without using extra cement, Complete all as specified and directed.
M&L for 12 mm thick modified polymer ready mix plaster to Concrete surfaces wall finished even and fair with 3 % of weight of cement WPC , complete all as specified and as directed.
M&L for rendering 10mm thick in CM 1:3 on ceiling of concrete surface and finishing the surface even and smooth all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying 1 coat of wall care white putty, 1-2mm thick and further applying 2 coats of oil emulsion distemper over a coat of wall priming paint complete all as specified and as directed.
M & L for complete removal of existing treatment on walls and applying 1 coat of wall care putty, 2mm thick and further applying two coat of oil bound distemper over one coat of primer paint complete all as specified and directed.
M&L for Preparation of new plastered surfaces in walls soffits, facia roof and applying 2 coats of anti fungal weather proof acrylic based paint 100% acrylic over a coat of external wall care putty coat over and including priming coat of exterior primer at any height including necessary scaffolding etc complete all as specified and as directed by Engr-in-Charge of weather coat primer all as specified.
Complete removal of existing treatment of wall ( any no. of layers) by scrapping with steel scapers or any other mean and applying external wall care putty 2 mm thick and making surface even and smooth to receive anti fungal weather proof acrylic based paint 100% acrylic over coat of exterior wall primewr after preparation of surface of at any height including necessary scaffolding etc. complete all as specified and as directed by Engr-in-Charge.
M&L for Preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for Preparation of old plastered/unplastered surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing of rubbish complete all as specified and directed.
M & L for Glazed ceramic coloured printed tiles in vertical surface 300x450x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface of tile including 15mm thick screed in cm (1:4) as in skirting/dado complete all as specified and directed by Engr-in-Charge.
M & L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, (300x300mm) in floors etc. set and jointed in neat cement slurry and joints pointed with Epoxy grout including 20mm thick screed 1:4 as in flooring complete all as specified and directed by Engr-in-Charge.
M & L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and joints pointed with Epoxy grout including 20mm thick screed 1:4 as in flooring complete all as specified and directed by Engr-in-Charge.
M & L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting /DADO etc. set and jointed in neat cement slurry and joints pointed with Epoxy grout including 15mm thick screed 1:4 as in flooring complete all as specified and directed by Engr-in-Charge.
Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar complete all as specified and directed by Engr-in-Charge.
M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-Charge.
M & L Marble (Baroda/ Udaipur green) 20mm thick machine cut as in flooring & skirting, including 20mm thick screed bed in CM 1:4, jointed and pointed with grey cement slurry and pointing with white cement (1:3) using marble dust with admixture of pigment to match with shade cutting and polishing etc complete all as specified and directed.
Demolition of PCC (unreinforced) in ground floors & pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge.
M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate for plinth protection with finishing cement concrete surface even and smooth Without using t extra cement complete all as specified and directed.
Cleaning of existing surface with wire brush removal of all dust & grit of sunken floors, providing 10mm thick rendering in CM 1:4 using WPC at the rate of 3% by wt of cement, one coat of hot blown bitumen VG10 grade @ 1.2 Kg/Sqm on all plastered surface and providing PCC 1:2:4 type B-1 with WPC in slope towards outside, min thickness of PCC is 25mm & max 75mm providing 40mm dia PVC spout of lenth 50cm complete and tested for leakage, seepage and filling with lime concrete or lean concrete 1:5:10 using bricks bat complete all as specified and directed.
Taking down aluminium sliding window / ventilator including glass complete all as specified and directed.
S & F powder coated aluminium frame and shutters for doors, windows, ventilators with one or more rebates including joining cleat and necessary fitting (handle, locking arrangement, stoppage) for fixing etc. complete all as specified and directed.
Taking down wooden chowkats or frames not exc 1.5sqm each with shutters (without taking off shutters from the frame) and disposing off complete all as specified and directed.
Taking down wooden chowkats or frames exc 1.5sqm but not exc 4sqm each with shutters (without taking off shutters from the frame) and disposing off complete all as specified and directed.
Taking down and refixing in same opening after resecuring or easing and adjusting size of shutter exc 01 Sqm but not exc 02 sqm each complete all as specified and directed.
S&F PVC door solid frame of size 50mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails MS frameshall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain cover PVC sheets for top rail, lock rail and bottom rail on either side and as gap insertfor top rail and bottom rail, panelling of plain of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles, and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixed in the frame at site as per specification and drawing.
S&F 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S&F 2nd class hardwood 35mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut & mitred beds for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a) to chowkats complete all as specified and directed.
S&F 35mm thick 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F Overall length of cover plate 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F Mild Steel 300mm, ordinary rat tail rod patttern springs including roller & roller plate complete all as specified and directed.
S & F of 100 mm long stainless steel butt hinges, medium weight approved make ISI marked complete all as specified and directed.
S & F 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F Aluminium handles 150mm long anidised aluminium cast type complete all as specified and directed.
M&L for preparation of new painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth including knotting and stopping and applying 2 coats of synthetic enamel paint over a prink primer (any tint/Shade) complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
S&F Hasp & staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate with screws 100mm size complete all as specified and directed.
S&F for 19/20mm Pre laminated interior grade both sides laminated complete all as specified
S & F Continuous (piano) hinges,Width of flaps (when open) 30 mm mild steel, bright finish or electrogalvanised complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise described for of any description complete all as specified and directed
S& F Framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors ladders; framed balusters walk ways railings framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed
Taking down aluminium decogrill of any size and any type complete all as specified and directed
S&F aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 103 or equivatent 6.5 mm thick all as specified and as directed
S&F 4.8 mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane all as specified and as directed
S&F Figured glass 4.0mm thick, pin head type & glazing with oil putty in squares n exc 0.5 sq.m in each pane complete all as specified and directed
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire & average width of aperture 1.40mm with aluminium wire staples complete all as specified and directed
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long complete all as specified and directed
S&F in repair 25mm dia Stainless Steel curtain rod etc complete all as specified and directed
S&F in repair statinless steel bracket for curtain rod of 25mm dia for fixing in walls etc complete all as specified and directed
Demolition and breaking up drain pipes 110/75mm of PVC SWR pipes laid in floor/wall complete all as specified and directed
S&F of PVC (SWR) pipes 110mm single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed
S&F of PVC (SWR) bends 110mm dia access to door complete all as specified and directed
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal access to door complete all as specified and directed
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed
S&F 75mm PVC (SWR) vent cowl complete all as specified and directed
S&F 75mm bore PVC SWR pipe single socketed in any length with rubber ring joints laid in in floor/wall complete all as specified and directed
S&F 75mm bore PVC (SWR) bands any radious complete all as specified and directed
S&F 75 mm bore PVC (SWR) junction single (Single T) equal or unequal access door complete all as specified and directed
M&L in 75 mm out let PVC floor trap, plain with openable (two piece type) grating including jointing with solvent cement complete all as specified and directed
M&L in 125/110 mm PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed
Taking up or down steel tubing of 20 mm bore and connections complete all as specified and directed
Taking up or down steel tubing of 25 mm bore and connections complete all as specified and directed
S&F in Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc pipes incl cutting/chases of walls etc 25mm inclluding fitting (such as elbow teen reducers, couplers short pieces, connection uion etc) whatever required as per dmanufacturer's instruction fixed on wall /ceiling complete all as specified and directed
S&F Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc pipes incl cutting/chases of walls etc 20mm inclluding fitting (such as elbow teen reducers, couplers short pieces, connection uion etc) whatever required as per dmanufacturer's instruction fixed on wall /ceiling complete all as specified and directed
S&F stailess stell plate rack of size 90x75x25cm depth made out of 0.80mm thick sheet complete all as specified and directed
S&F in repair sink with drainage board made of stain finish 1 mm thick kitchen or laborator with plugs washere and waste including bedding in cement mortar to dwarf wall or including fixing cantilever brackets overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and directed
S&F in repair vitreous China wash down water closet pan (Pedestal Pattern) white (excluding fixing bolts, flushing cistern and flush pipe) and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe including seat cover etc complete all as specified and directed.
S&F in repair 10 Litres, PVC valvless,syphonic action type, flushing cistern, low level, white, with inlet, ball vlave, float and handle including bracket complete all as specified and directed
S&F in repair Vitreous China wash basin, white, flat back, size 550x400 mm excluding taps, waste coupling and waste pipe.including cutting for and pinning in ends of brackets or recting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed
S&F grating square 150 mm size of PTMT openable type complete all as specified and directed
S&F PVC waste pipe suitable for wash hand basin/sink including fixing arrangement complete all as specified and directed
S&F 32 mm bore waste coupling of PTMT (half of full thread) complete all as specified and directed
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed
S&F in repairs Fancy type bib taps, long shank chromium plated cast copper alloy 15mm bore with crutch screwed down and fixed complete all as specified and directed
S&F in repairs long shank CP Pillar taps 15 mm dia but fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for PVC pipe and fixed complete all as specified and directed
S&F in repairs 15mm dia stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch, screwed at both ends for iron pipe or for unions complete all as specified and as directed
S&F in repair 120mm dia chromium plated overhead shower with arm complete all as specified and directed
S & F in repair soap dish, fixed to tiled wall surfaces with plugs and chromium plated brass screws complete all as specified and directed
S & F Brass chromium plated tubular towel rod 600mm long complete all as specified and directed
S&F 20mm thick granite machine cut corner shelf of dia 25cm (inner quarter circle shape) nosing and polishing complete fixed to wall in CM 1:3 mortar complete all as specified and directed
Dismantling of water storage tank of exc 250 ltrs& n exc 500 ltrs capacity complete all as specified and directed
S&F 500 Ltrs Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed
S&F in repair 25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms / 20mm - 210 gms / 25mm-455gms / 40mm - 690 gms) complete all as specified and directed
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for complete removal of loose / cracked concrete incl reinforcement if required, from RCC roof projection, chajja, fins, facia etc and making good with any slab and in any position finished the surface even and smooth without using extra cement including necessary form work and welding/binding of reinforcement (including reinforcement) if required complete and match with the existing surface complete all as specified and directed
Chipping and removal of spalled concrete, cracked, porous and weak concrete up to a depth of the reinforcement rods or depth of carbonation whichever is deeper and cleaning of the reinforcement bars and exposed concrete to remove scales by chipping, wire brushing, emery sheets etc to enable the measurement of reduced dia of the bar, application of zinc primer to the reinforcement on all sides of the reinforcement and application of epoxy bonding agent to exposed old concrete surfaces. The job shall be carried with contractors own pneumatic chipper / manually with all required resources, tools and tackels up to the satisfaction of EIC. payment towards application of zinc primer and epoxy bonding agent shall be paid in respective item rate of contract complete all as specified and directed
Providing and plaing in position Micro - Concrete as per relevant ASTM / BS / IS having comp. strength of min 45 mpa at 2 days of make PIDILITE/ BASF/SIKA/FOSROC or equivalent in columns and beams, which shall be pre-packed single component, chloride free, non shrink, free flow, self compacting and mixed as per manufacturere spacification, including required leak proof shuttering, pre - soaking of substrate, manual application or pumping, manpower and tools & tackles complete all as specified and directed
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal or rubbish to the dumping ground within 50m lead With cement mortar 1:4 (1Cement:4Coarse Sand) complete all as specified and directed
Taking down / Demolition of old textile covering form roof (old WPT) complete all as specified and directed
M&L PCC type B-1. 1:2:4 (20 mm graded aggregate) as in Padding concrete to over roof slab 40 mm thick mixed with WPC 3% by weight of cement, finished even and fair complete all as specified and directed. (WPC shall be measured and paid separately).
M&L for Forming Contraction (Dummy) joints Grade 'A' 30mm deep x 10mm wide, filled with sealing compound complete all as specified and directed.
M & L for Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions.
M & L Rendering 10 mm thick rendering in CM (1:4) over PCC padding surface finished even & smooth using extra cement with WPC @ 3% by weight of cement complete all as specified and directed (integral WPC will be measured separately)
Supply only integral waterproofing compound complete all as specified and as directed.
M&L for PCC 1:2:4 Type B0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges finish surface even and smooth including form work complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar all as specified and as directed by Engr-in-Charge.
M&L for walling of Porbandar stone masonry well bonded and solidly hearted built in CM 1:6 complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
Surfaces excavation not exceeding 30 CM deep and averaging 15 CM deep and getting out in Soft/disintegrated rock complete all as specified and directed.
M & L stone kerb of roughly squared stones of size 20cmx30cm dressed so that the maximum depression from straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20 mm for the rest of surfaces, jointed in cement mortor 1:6 and struck flush, including embedding stones in the ground to depths indicating and tamping ground around stones and also removing any surplus spoils, etc. complete all as specified and directed.
M & L cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for even spreading of 25mm thick layer of sand cushioning incl watering & consolidation complete all as specified and directed.
M&L for machine pressed precast concrete rubberised inter locking paver blocks any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade complete all as specified and directed.
M&L for preparation of new painted surfaces and applying two coat of synthetic enamel on brick, stone, concrete, asbestos cement or plaster surface complete all as specified and directed.
Removing excavated material (rocks) exc. 250m n.exc 500 m and depositing where directed at a level of n.exc 1.5mtrs above the starting point in (Soft/disintegrated rock) complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, manholes, etc. or for laying cables/pipes, erecting poles etc. n exc 10 sqm on plan and getting out in soft/ disintegrated rock complete all as specified and directed.
M&L for Concrete bed Type D2 1:4:8 to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for reinforced concrete pipe of 150mm bore of pipe, class NP-2, laid and jointed with collars complete all as specified and directed.
M&L for pre-cast reinforced cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in manhole cover with plain fair surface including chamfers, weatherings, throatings, necessary form work and set in CM (1:6), placed in position complete all as specified and directed.
M & L Mild steel TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Cutting into existing manholes of 150mm internal dia of pipes for connecting new drains, making good to pipe and rendering cutting out existing benching and forming branch channel in PCC (1:2:4) type B-1, smooth finished complete all as specified and directed.
M & L Rendering 15 mm thick in CM (1:4) on stone/concrete surface finished even & smooth with using extra cement incl using integral WPC etc complete all as specified and directed. Note : Integral WPC will be measured separately.
M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in copings, benching, and the like including weathering, sightly rounded or chamfered angles and throating complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in hard dense soil complete all as specified and directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed as in rock complete all as specified and directed.
Taking down carefully aluminum/copper point wiring (light,fans,socket etc) complete incl battens and fittings such as switch, ceiling rose,light fittings, regulaters, socket etc and making good disturbed surface of wall/floor etc complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly drawing into and including rigid non-metallic PVC conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories by cutting of chases in wall/roof/floors concealed in walls/roof/floors with MS sheet metal/PVC sunken modular switch/Terminal box 1.2 mm thick and Modular plate and screws with cup washers all as directed and specified Note : (1) Rate is inclusive of Cutting/chases of wall/floor/ceiling and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light/fan/bell point.
Ditto all as per Item No. 122.00 above but for one light point for 2 way switch board complete all as specified and directed.
Ditto all as per Item No. 122.00 above but for 5 amps socket outlet on same board board complete all as specified and directed.
Ditto all as per Item No. 122.00 above but One 3 pin socket outlet, 5 Amps,independent borad complete all as specified and directed.
Ditto all as per Item No. 122.00 above but for One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size complete all as specified and directed.
Ditto all as per Item No. 122.00 above but for One 3 pin socket outlet with 2.5 sqmm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
Ditto all as per Item No. 122.00 above but for one AC Point with 4 sq mm PVC unseathed (FRLS) wire along with 4 sq mm green colour wire as earth contuinity conductor connected to common earth dolly complete all as specified & as directed by engr-in-charge. Note : Seprate circuit of individual point will be drawn from the DB directly for AC Point complete all as specified and as directed.
M/L and Repair/Replacement for Sub main wiring power/circuit using PVC insulated unsheathed FRLS, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through in and including PVC conduit concealed in walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 6 sqmm and one wire of 6 sqmm & PVC conduit shall be measured as one unit.
M/L and Repair/Replacement for Sub main wiring power/circuit using PVC insulated unsheathed FRLS, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through in and including PVC conduit concealed in walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 4sqmm and one wire of 4 sqmm & PVC conduit shall be measured as one unit.
Supply and Repair/Replacement of ceiling rose surface backelite 65x50 mm having 3 terminal complete all as specified and directed..
Supply and Repair/Replacement of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engr-in-Charge.
Supply and Repair/Replacement of Lamp 10 Watt LED complete all as specified and as directed by Engr-in-Charge.
M&L for SPN Sheet metal enclosures with plug and socket with Top and MCB SP 20 Amps including taking down the same. all as specified and directed by Engineer - in - Charge.
M&L for taking down and refixing for after Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and as directed.
M&L for taking down and refixing for after Painting of Exhaust fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and as directed.
M&L for taking down and refixing for after Painting of Geyser complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and as directed.
Repair/replacement of Flexi connection pipe accessory 450mm for water heater any type/capacity complete all as specified and directed
M&L For breaking the existing wall to make hole for exhaust fan and making good to the disturbed surface of wall complete all as specified and directed at site.
Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as spcified and as directed
Supply and fixing Repair/Replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and as directed
Supply and fixing Repair/Replacement LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed
Supply and Repair/Replacement of Decorative wall light made up of high grade engineering plastic material suitable for retrofit CFL 20 W . with all connected accessories internally pre-wired, including 9 W LED bulb connecting lead of 3 core 1.5sqmm flexible copper wire 1.5sqmm from ceiling rose to fitting complete all as specified.
Supply and Repair/Replacement of Building street light fitting Endura pearl 20W LED lamp new genaration energy saving & environmental friendly long life made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impect resistance of IK07,with suitable of GI pipe (light grade) bracket and clamps,nut bolts are fixed on wall/post and all as required and directed.
Supply and Repair/Replacement of for Modular switch 1 way 6 Amps, 1 modules 230 volts complete all as specified and directed.
Supply and Repair/Replacement of for Modular switch 2 way 6 Amps, 1 modules 230 volts complete all as specified and directed.
Supply and Repair/Replacement of for Modular switch 1 way 16 Amps, 1 modules 230 volts Complete all as specified and directed.
Supply and Repair/Replacement of Modular socket 6A, 2/3 pin combined, 2 modules 230 volts complete all as specified and directed.
Supply and Repair/Replacement of Modular socket 6A/16A, 2/3 pin combined, 2 modules 230 volts complee all as specified and directed.
Supply and Repair/Replacement of bell push 6 Amps, 1 modules 230 volts complete all as specified and directed.
Supply and Repair/Replacement of call bell Multi musical type complete all as specified and as directed
Supply and Repair/Replacement of five step fan Modular regulator 2 module 230 volts complete all as specified and directed.
Supply and Repair/Replacement of MCB DB Single pole and neutral 12 way 240V double door Complete all as specified and as directed.
Supply and Repair/Replacement of MCB TPN DB 4 way 415V double door Complete all as specified and as directed.
Supply and Repair/Replacement of MCB DB Single pole and neutral 2 way single door Complete all as specified and as directed.
Supply and Repair/Replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity SP 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engineer - in - Charge.
Supply and Repair/Replacement Supply and fixing SPN 40 amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer - in - Charge.
Supply and Repair/Replacement Supply and fixing SPN 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer - in - Charge.
Supply and Repair/Replacement of 63 amp TPN 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer - in - Charge.
M&L and Repair/Replacement of fabrication of Wooden Box as suitable for SPN 4 way to 12 way DB to be covered as per existing including suitable mason work,surface finishing as per original and locking system complete all all as specified and as directed.
M&L and Repair/Replacement of fabrication of Wooden Box as suitable for TPN DB to be covered as per existing including suitable mason work,surface finishing as per original and locking system complete all all as specified and as directed.
M&L in Replacement of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised earth lead wire 4.0mm dia by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed.
Supply Repair/Replacement Laying and Testing of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fittings and making connection fixed complete to walls, ceilings floors or laid in trenches etc. of 32 mm dia laid in trenches complete all as specified and directed.
Supply Repair/Replacement Laying and Testing of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fittings and making connection fixed complete to walls, ceilings floors or laid in trenches etc. of 25 mm dia laid in trenches complete all as specified and directed.
Supply Repair/Replacement Laying and Testing of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fittings and making connection fixed complete to walls, ceilings floors or laid in trenches etc. of 16 mm dia laid in trenches complete all as specified and directed.
S&F in repair/Replacement of CPVC ball valve of 32mm dia as per requirement of the site complete all as specified and as directed.
S&F in repair/Replacement of CPVC ball valve of 25mm dia as per requirement of the site complete all as specified and as directed.
Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
Supply and Laying HDPE pipe ISI Marked complete for cable protection laid in trenches, floors, fixed to walls, pole with suitable FI clamps complete all as specified and directed ISI marked. of size 40mm dia complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete all as specified and as directed.
J J ENTERPRISES
Nitesh Enterprise
JAY BHARAT METAL SUPPLIERS
K K Construction Co
OM ENTERPRISE
shree chamunda enterprise
Harsh Infrastructure
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .