Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹14.8 L+₹63,926.96 (4.52%)Rejected-AOC 79B MIG PHASE 1 INDIRA PURAM G M S ROAD DEHRADUN UK PIN 248171 | DEHRADUN | UTTARAKHAND | 248171 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹15.9 L+₹1.8 L (12.4%)Rejected-AOC HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹16.7 L+₹2.6 L (18.1%)Rejected-AOC 3491 14 HARIPURA DHAPAI ROAD AMRITSAR | AMRITSAR | PUNJAB | 143001 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to criteria not fulfilled as par NIT |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
2 Apr 2022, 6:00 pmClosed
CWE Hills Dehradun
Headquarters Commander Works Engineers Hills Military Engineer Services Mall Road Dehradun Cantt
SPL REPAIR TO BUILDING NO P 03 Single JCOs Living AND DRAINS FROM RP GATE TO BLDG NO P 74 OF 342 FD REDT AT NARENDRA NAGAR AT RAIWALA MILITARY STATION UNDER AGE I RAIWALA
2021_MES_495981_4
86341/RWL/E8
Open Tender
Civil Works
Item Rate
150 days
AGE I Raiwala
Class E Cat a i
6 documents required · 6 mandatory
₹500
AGE I Raiwala
₹29,000
Yes
13 Jun 2022
14 Mar 2022
4 Apr 2022
14 Mar 2022
2 Apr 2022
21 Mar 2022
14 Mar 2022 - 16 Mar 2022
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD land complete all as specified and directed.
M&L for coloured glazed ceramic tiles of 1st or premium quality edges cut joint free in vertical surface glossy finish of any design and pattern, (all as approved by GE/AGE (I) ), of size 300x450x 7 to 8 mm thick, as in dado etc over & incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I)
M&L for Non- skid coloured ceramic tiles of any design and pattern, (all as approved by GE/AGE (I) ) , 400X400X7 to 8 mm thick, in floor etc over & incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles.Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE
M&L for coloured vitrified tiles of any design and pattern, (all as approved by GE/AGE (I) ), of size 600X600X 9 to 10 mm thick, in floor etc over & incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles.Tiles shall be confirming to IS-15622.2017, Group B 1b with average water absorption between .08 % to 3%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 4.0% (Max deviation). Centre & Edge curvature and warpage + 0.20% (Max deviation). Breaking strength 1200 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE
M&L for coloured vitrified tiles of any design and pattern, (all as approved by GE/AGE (I) ), of size 600X600X 9 to 10 mm thick, in dado/skirting etc over & incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles.Tiles shall be confirming to IS-15622.2017, Group B 1b with average water absorption between .08 % to 3%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 4.0% (Max deviation). Centre & Edge curvature and warpage + 0.20% (Max deviation). Breaking strength 1200 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE
Taking down chowkhats or frames of any description with shutters (without taking off shutters from the frames) exc. 1.50 but n exc.4.00 sqm each including removal from site complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutters from the frames) n.exc. 1.50 sqm each including removal from site complete all as specified and directed.
S&F 125 mm x 65 mm Double Rebate Factory made 100% Solid WPC door Frame made from 100% LEAD FREE (Single extruded process) material with density 780 kg / Cum & Manufactured by an ISO:9001-2015 certified company, all as per specification drawing as directed by the Engineer-In-Charge.The door frame should be Water proof, Termite proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
S&F 100mm X 63mm Single Rebate Factory made 100 % Solid WPC door Frame made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cum & Manufactured by an ISO: 9001-2015 certified company, all as per specification. The door frame should be Water Proof , Termite Proof , Fire Retardent and having excellent screw holding capacity complete all as specified & directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flameof Class A category with property of being termite/borerproof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified directed. Note:- Stainless steel butt hinges and necessary S S screws shall be paid separately Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
M&L Providing 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and complete all as specified and directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
S&F factory made solid panel PVC window shutter 30 mm thick (style) but fully glazed ie glass pane used instead of 5 mm single side prelam PVC sheet panels, shutter frame made out of MS tubes for top and bottom rail MS frame shall be covered with heat moulded single side prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck in side solvent cement for stiles and single side prelame PVC sheet for top and bottom rail on either side and as gap insert for top rail and bottom rail glass pane to be fittted with suitable PVC sheet beading complete all as specified & directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
S&F factory made solid panel PVC window shutter 30 mm single side (style) but wire gauzed ie wire gauzed will be used instead of 5 mm single side prelam pvc sheet panel shutter frame made out of MS tubes for top and bottom rail MS frame shall be covered with heat moulded single side prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck in side solvent cement for stiles and single side prelame PVC sheet for top and bottom rail on either side and as gap insert for top rail and bottom rail the tube and this tube shall be welded to ms tubes including S.S wire mesh shall be fixed with 15 x 15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove of fix again after changing of wire mesh when needed complete all as specified & directed. ake:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY Note:- Rate of stainless steel wire mesh is included in the item.The wire gauge shall be streched to tighten firmly complete all as per specification and drawing.
S&F Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified & directed.
S & F for Aluminium anodized barrel tower bolt of 12 mm dia and 200 mm length of extruded section (ISI Marked) complete all as specified and directed
S & F for Aluminium anodized barrel tower bolt of 12 mm dia and 300 mm length of extruded section .(ISI Marked) complete all as specified and directed.
S & F 100 mm long stainless steel (AISI 316 grade) bearing hinges, 4 bearing, complete all as specified and directed.
S&F in repair Wash basin (Padestal Pattern) of size 550x400mm vitreous china (flat back type) any size (ISI Marked) incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fittings complete all as specified & directed.
S&F in repairs 10 liter capacity PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), low level , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for indian Type WC of polyethylene of low or high density or PVC 32 mm dia for low level cistern complete all as specified & directed.
Dismantaling of old damaged water tanks of any description & removal from site and S&F new rotational moulded polyethylene water storage tank 1000 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed.
S&F for Extruded Aluminium alloy handles,fabricated type, anodised 150 mm long, (ISI Marked) complete all as specified and directed.
S & F for Aluminium alloy anodised sliding door bolt, of size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy complete all as specified and directed
M & L for Glazing with plain sheet glass, ordinary quality, 4 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed.
M & L for Glazing with figured glass (Frosted), pin head type, 4 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia complete all as specified and directed.
M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work , "medium grade", together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors complete all as specified and directed
S & F in repairs 15 mm bore chromium plated bib taps, (ISI Marked) cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make:- Jaquar Cat No-MQT-512KN/Hindware cat No-F200001/Prayag Cat No-6502 Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site
S&F in repair wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm bore pipes complete all as specified and directed. Make:-Jaquar Cat No-MQT-517BKN(wall mixer) , EOS-542A(Shower) & ALE-536A(Shower arm/Hindware cat No-F200020 (wall mixer) & F160120 (shower with arm) / Prayag Cat No-6575 (wall mixer),& BS-36(Shower with arm) Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site
S&F in repair 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe complete all as specified and directed. Make:- Jaquar Cat No-MQT-516AKN/Hindware cat No-F200014/Prayag Cat No-6550 Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site
S & F in repair for Grating , stainless steel with / without hole, round 125 mm dia chromoum plated Complete all as specified and directed
S & F in repairs Stop angle valves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. Make:-Jaquar Cat No-MQT-526NKN/ Hindware cat No-F200005/Prayag Cat No-6510 Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site
S&F for PVC Connections 15mm size with PTMT nuts of length 450 mm (ISI Marked) complete all as specified & directed.
S&F in repairs Vitreous china wash down water closet pan (padestral pattren) (ISI Marked) white complete including seat cover, flush pipe but excluding flushing cistern ncluding connection to trap, to flushing pipe, anti-syphonage pipe, etc complete all as specified & directed.
S&F in repair Plastic water closet seat white closed pattern with flat bootm and cover and mild steel chromium plated or aluminium hinging device and jointing complete all as specified & directed.
S & F Health Faucet with hose & hook (complete set) fixed to angle / stop cock 15 mm dia Complete all as specified and directed. Make:-Jaquar Cat No- ALD 573/Hindware Cat No F160068/ Parryware Cat No T9961A1
M&L Preparation of New wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint (any tint) Ist quality over a coat of pink primer complete all as specified and directed.
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed.
M & L Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:6 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement complete all as specified and directed. Note:- Integral water proofing liquid will be measured and paid seperately.
M & L Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & smooth without using extra cement complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes (ISI Marked) single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) bends (ISI Marked) of any radius complete all as specified and as directed.
S&F in repair stack clamps out of 50mmx 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to walls or roof for 110 mm pipe, complete all as specified and directed.
Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
Supply only SBR Latex liquid polymer of approved make complete all as specified & directed.
M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (as per manufacture direction and paid separately) over and incl one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer direction and finishing the surface even and smooth(without using extra cement) as in roof padding /sunken floor to receive water proofing treatment complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note:- 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
M& L for concrete angle-fillets with a radiaus of 75 mm to 100 mm at junction between roofs/chajja/top surface of projected cub noards and vertical faces of wall (parapet and other walls) to ease up about corners and over chajjas/projected cub board with PCC 1:2:4 type B-0 (using 12.5 mm stone aggregate) Mixed with liquid integral water proofing compound (Mixed as per manufacture direction) incl using form work (straight or curved ) as required complete all as specified and directed.
Supply only liquid integral water proofing compound complete all as soecidied & directed.
M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge . Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
Demolition of Brickwork or Stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc & removing from MOD land complete all as specified and as directed. Note:-After demoletion the serviceable bricks shall be stacked properly for re-use under relivent item of Sch 'A' as per the direction of Engg-in-Charge and mortar shall be removed from bricks built in cement or cement lime mortar, bricks shall be cleaned & stacking for measurement to the entire satisfaction of Engg-in-Charge. The ibid item also includes all extra handling and removal and disposing off rubbbish from MoD land complete all as specified and directed. The rates quoted by the contractor in this item encludes all these auspects of work.
Demolition of concrete(un-reinforced) any description and laid in any position & removing from MOD Land complete all as specified and as directed .
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub-class 'B' bricks (except bricks), straight or curved on plan exceeding 6 M mean redius built in cement mortar 1:6 complete all as specified and directed. Note:-The seviceable bricks retrieved from item no-53 above shall be reused under this item.
M & L for rendering 15mm thick in CM 1:4 on brick surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for PCC 1:3:6 Type C2 (using 40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M & L for PCC 1:2:4 Type B-1 20mm graded aggregate as in Surface channels , coping and drains complete all as specified and as directed.
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material & Labour for Point Wiring for one light Point/one fan point (Ceiling/Exhaust)/ one call bell point, controlled by one one way 5 Amps switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit,medium grade(ISI marked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per item no 61 above but for One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
All as per item no 61 above but One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
All as per item No 61 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or Cona Cat Part No: 9251
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC complete all as specified and directed. Make: Legrand cat No: 673411/ Indoasian Cat No: 800002 or Cona Cat Part No: 9386
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 52 / Indoasian cat no: 800020 or Cona Cat Part No: 9301
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz complete all as specified and directed. Make:- Legrand cat No: 6734 55 / Indoasian cat no: 800022 or Cona Cat Part No: 9311
S/F ceiling rose (ISI Marked) surface Bakelite AC 220/240 volts 3 terminals complete all as specified & directed.
Supply and fix surface mounted LED luminiare, 20 watt 4 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. Note:- The firm has to give warranty for fitting including driver minimum for 3 years for any defects developed during the period.
Supply and fix new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit protection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including making necessary electric connection with 1.5 sqmm , 3 core, PVC insulated copper conductor cable 1100 Volt grade complete all as specified and as directed. Note:- (i) The firm has to given warranty of street light fittings including driver minimum for 02 years for any defect developed during the period. (ii) The contractor Shall submit the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No
S & F Batten PVC polycarbonate holder 230 V, ISI marked, suitable to fix 9 Watt LEd bulb complete all as specified and directed. Note:- LED bulb 9 watt shall be fix as supply only item here-in-after.
Supply only 9 Watt LED inverter bulb works on AC supply in normal mode and DC suypply in Inverter mode, with inbuilt battery back up of up to 4 hours, high efficency, high lumens output, options of B 22 base 5 star rated, ISI marked, 240 volts complete all as specified and directed.
Supply & fix energy efficient ceiling fan 5 star rated with BLDC motor and blades, 1200 mm sweep with & including electronic fan regulator, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with operating voltage of 140 to 285 V, with metallic finish , accessories / remote toggle switches pre wired and connected through PVC connector complete all as specified and directed. Make: Havells/Orient/bajaj
S & F fresh air fan AC single phase 230/240 Volt of size 300 mm sweep, metallic body powder coated painted finish, Power consumption- 50 W, Air displacement -1290 Cum/Hr, RPM-900 complete with louvers including making core cutting on exisiting brick/masonory wall suitable to fix fan and grouting of nut bolts etc and making good the disturbed surfaces of wall complete all as specified and directed.
S& F double door sheet metail enclosure for DB , 12 way , SPN, with 200 Amps bus bar, 240 Volts suitable for housing MCBs and isolator and making good for disturbed surface with existing etc complete all as specified & directed.
Supply and fixing MCB SPN 10-25 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 10 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified & directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 2 to 4 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified & directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 3.20 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 5 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall, LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 16 sqmm 2 core with required aluminium cable lugs, lugs should properly crimp with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement, including taking down old unserviceable service/UG cable of any size from building/trunches complete all as specified and directed. Note: Ecavation & earth work required shall be measured and paid separately under relevant item of sch A.
Excavation in trenches in any type of soil and n.exc 1.5 m wide and n. Exc 1.5 in depth for laying GI tubing for connect to near by water pipe line or for poles, laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and directed.
Returing, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, in any type of soil complete all as specified and directed.
Removing excavated material ( surplus soil) to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specifed and directed.
M&L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable complete all as specified and directed. Note:- Measurement of sand to be taken consolidated thickness after punning down.
M & L for cable protection bricks common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches all as specified and directed at site complete all as specified and directed.
M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) of minium size 150mm X 100mm in respect of width and thickness complete all as specified and directed.
Supply, laying & joined Galvanised Tubing 50 mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc for cable protection including taking down old one complete all as specified and directed.
ACE BUILDERS AND CONTRACTORS
M/s Arihant Builders
AMARJEET SINGH AND CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .