| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹11.2 L+₹1.4 L (14.1%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹12.3 L+₹2.5 L (25.8%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹15.9 L+₹6.1 L (62.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
8 Jan 2022, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
REPAIRS/ REPLACEMENT OF E/M INSTALLATION AND OTHER MISC ALLIED WORKS AND REPAIR AND MAINTENANCE OF FIRE FIGHTING SYSTEM PIPE LINES, STAND POST, HYDRANT VALVES, HOSE BOXES AND DIESEL PUMPS AT INS KALINGA, DRDL, INS KARNA AND NAD BHEEMUNIPATNAM UNDER G
2021_MES_487620_2
GE (P)/N/K/8841 OF 2021-22
Open Tender
Civil Works
Item Rate
120 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class E, Category b(i)
6 documents required · 6 mandatory
₹500
Yes
Garrison Engineer P Navy Kalinga Visakhapatnam
₹26,000
Yes
24 Mar 2022
17 Dec 2021
10 Jan 2022
17 Dec 2021
8 Jan 2022
25 Dec 2021
Amount
Taking down carefully existing aluminium conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls, roof and floor etc as per existing specification.
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site. (Note : To be measured only when found serviceable in all respects complete for reuse)
Material and labour for point wiring for one light/ fan point controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through existing/ new PVC concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 2mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface.
All as per item No 3 above but for one three pin switch socket outlet, 5 Amp on independent board.
All as per item No 3 here-in-before but for one 15 Amp 3 pin switch socket outlet, independent with 4.0 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 5 amps .
Supply and fixing switch socket combination 2 in 1 3 pin, 5 amp flush type .
Supply and fixing switch socket combination multipurpose 3 pin 15 amp flush type ..
Fixing Only switch socket out let multipurpose 3 pin 15 amp and one 3 pin 5 amp controlled by one switch . (Material obtained from item No 2 here in before )
Supply and fixing fan regulator electronic deluxe rotary step type .
Supply and fixing indoor luminare decorative batten for wall/ceiling mounting box type energy efficient saving LED BATTEN LIGHT 18 W/ 20 W (4 feet), 230 V, 50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector .
S&F energy saving & environment friendly long life 25 W, CT >= 5700 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more and high brightness LEDs, luminaire efficacy > 110 lumens / Watt, power factor >= 0.90 operating range – 140 to 270 V, 50 Hz complete including connecting up with and including twin / three core twisted flexible copper conductor cable of suitable size and GI bracket medium grade 1.5 mtr long in angular shape with clamp complete .
M&L for LED tube 18 watt fixing in existing unserviceable tube light fittings with taking down old unserviceable tube
S&F LED strip light 20 watt with suitable driver of same make fixing in false ceiling grooves at required site and installed by expert electrician and connect from existing incoming wire, including taking down old unserviceable one.
S&F LED flood light 120 watt, IP 65 protection guard for existing false ceiling/ pole/ wall/ tower/ ground with suitable size necessary fitting and fixture (hook/ suspended rod of required size) existing electric incoming cable incl taking down old unserviceable one.
S&F LED highbay light 150 watt, IP 66 protection guard for existing false ceiling/ pole/ wall/ tower/ ground with suitable size necessary fitting and fixture (hook/ suspended rod of required size) existing electric incoming cable incl taking down old unserviceable one.
S&F in repair LED lamp 40 W in existing lamp fittings.
S&F in repair lamp holder insulated body suitable for retrofit lamp.
Supply and fixing ceiling rose surface bakelite three terminals .
S&F in repair sheet metal enclosure for MCCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts .
S&F in repair MCB, FP, rupturing capacity 10 kA, ‘C’ curve, 63 Amp, 415 volts ISI marked.
S&F in repair MCB, rupturing capacity 10 kA, ‘C’ curve, Single Pole, 6 to 32 Amp.
S&F in repair MCB, DP, rupturing capacity 10 kA, ‘C’ curve, 40 Amp, ISI marked.
M&L for Sub main wiring with two run of 6.00 Sqmm (nominal cross-sectional area) FRLS PVC insulated and unsheathed 1100 V grade multi stranded copper conductor single core cable drawn through and including PVC medium grade conduit of 25 mm dia with all fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLS PVC insulated and unsheathed single core multi stranded copper conductor cable of size 6.00 Sqmm as earth continuity conductor connected to common earth and earth dolly for main DB to sub DB including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends with taking down old unserviceable sub main wiring and making good the disturbed surfaces . Note : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length.
M&L for Sub main wiring with two run of 4.00 Sqmm (nominal cross-sectional area) FRLS PVC insulated and unsheathed 1100 V grade multi stranded copper conductor single core cable drawn through and including PVC medium grade conduit of 25 mm dia with all fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLS PVC insulated and unsheathed single core multi stranded copper conductor cable of size 4.00 Sqmm as earth continuity conductor connected to common earth and earth dolly for main DB to sub DB including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends with taking down old unserviceable sub main wiring and making good the disturbed surfaces . Note : Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length.
S&F in repair PVC conduit of 20 mm dia ISI marked with all fittings and accessories for protection of cable laid in trenches/ wall/ floor .
S&F in repair PVC casing capping of 20 mm dia ISI marked with all fittings and accessories for protection of cable laid in trenches/ wall/ floor.
M&L for taking down the unserviceable contactor & burned out copper wire, lugs and S&F new power contactor 3 pole AC control capacity 25 Amp, 220-240 coil volt, including the copper wire & copper lugs and testing. (GE Cat Part No. CL01A310T or equivalent as approved by GE)
M&L for taking down the unserviceable contactor & burned out copper wire, lugs and S&F new power contactor 3 pole AC control capacity 25 Amp, 220-240 coil volt, including the copper wire & copper lugs and testing. (GE Cat Part No. CL25A300T or equivalent as approved by GE)
M&L for taking down the unserviceable contactor & burned out copper wire, lugs and S&F new power contactor 3 pole AC control capacity 32 Amp mounting type DIN rail, 220-240 coil volt, including the copper wire & copper lugs and testing. (ABB Cat Part No. A30-30-10 or equivalent as approved by GE)
M&L for taking down the unserviceable contactor & burned out copper wire, lugs and S&F new power contactor 3 pole AC control capacity 32 Amp mounting type DIN rail, 220-240 coil volt, including the copper wire & copper lugs and testing. (C&S Cat Part No. TC1D2510 or equivalent as approved by GE)
M&L for taking down the unserviceable contactor & burned out copper wire, lugs and S&F new power contactor 3 pole AC control capacity 30 Amp, MNX12 TYPE, mounting type DIN rail, including the copper wire & copper lugs and testing.
M&L for taking down the unserviceable contactor & burned out copper wire, lugs and S&F new power contactor 3 pole AC control capacity 32 Amp, MNX32 TYPE, mounting type DIN rail, including the copper wire & copper lugs and testing.
M&L for taking down the unserviceable contactor & burned out copper wire, lugs and S&F new auxiliary contract block, single phase DC voltage 600 V, power contactor 3 pole AC control capacity 32 Amp. (GE Cat Part No. BCLP10 or equivalent as approved by GE)
M&L for taking down the unserviceable CONTACT BLOCK and S&F new auxiliary contract block, single phase DC voltage 600 V, power contactor 3 pole AC control capacity 25 Amp. (C&S Cat Part No. TA1-DN 22 or equivalent as approved by GE)
M&L for taking down the unserviceable CONTACT BLOCK and S&F new auxiliary contract block, single phase DC voltage 600 V, power contactor 3 pole AC control capacity 25 Amp. (L&T Cat Part No. MNX-A2 or equivalent as approved by GE)
M&L for taking down the unsv timer supply and S&F new timer mounting din rail rated voltage 230 V, IP 50. (SELEC Cat Part No. 800 SD-2-230 or equivalent as approved by GE)
M&L for taking down the unsv relay and S&F new relays RT series wide range of AC AND DC COIL VOLTAGE high switching current capability and reliable, long operational.
M&L for taking down the unsv relay and S&F new relays 14 to 23 Amps, MN series type MN2 high switching current capability and reliable, long operational.
M&L for taking down the unsv relay and S&F new relays 9 to 15 Amps, MN series type MN2 high switching current capability and reliable, long operational.
S&F in repair MPD power supplier of capacity 5-30 Amps auxiliary supply, 15 V, AC 230 volt, 50 Hz, AC supply.
M&L for taking down the defective unsv solenoid valve coil and S&F of new coil suitable to work in single phase, AC 220 Volt, 50 Hz.
S&F in repair single phase preventer ,6 wires, 230 volt.
M&L for earthing complete with 7.5m CI pipe 80 mm dia with flanged ends, centrifugally cast, class A, in any length, joints with stainless steel nuts and bolts and sufficient slot upto 2.5 mtr length buried directly and preferably vertically in ground with top flanged ended 2.5 mtr below ground level welded/ connected with GI strip 32 x 6 mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400 mm dia bore any strata of soil to lower the CI pipe complete including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick precast RCC (1:2:4) type B-1 cover slab and necessary testing on completion .
Comprehensive repair/ maintenance electric operating system with gear and 3 phase 415 volt for rolling shutter motor. a) Dismantling the electrical connection from system and removing out the Induction Motor and Gear Box for Reconditioning/ Overhauling completely. b) Transporting the induction motor capacity 1 HP to civil work shop and strip opening the motor and removing out the burnt out winding and cleaning of the stator core and rewinding with suitable size super enamelled copper wire with necessary insulation and varnishing , replacement of unserviceable ball bearing and assembling back the motor and re-fixing with gear box and necessary electrical connections and testing completely.
c) Overhauling and servicing of speed reducing gear box assembly and greasing servicing and filling of new gear oil for smooth functioning of the system completely. d) Refixing back the entire system (Gear box and Induction motor) with necessary alignment with main shaft for smooth functioning of the system. e) Dismantling the unserviceable motor controller device 3 phase 440 volt with relay 1 No. Contactor 2 Nos NO and NC relay and push buttons with sheet steel enclosure etc and S&F new motor controller with necessary control wiring and testing completely. f) Dismantling the limit switches with necessary metal parts from rolling shutter and S&F new Limit Switch of suitable size and capacity with necessary welding/ brazing with shutter frame with necessary alignment complete. g) Fabrication and supply and fixing base frame for induction motor and gear box assembly with suitable nut bolt washers etc. h) Testing and commissioning the rolling shutter
M&L for carrying out general and routine maintenance 'B' check including replacement of filters such as oil filters, fuel filters, cooling elements and complete with 'O' rings and drain out the engine oil and filling up with the new engine oil including testing up to 100 kVA DG sets complete all as specified and directed by the Engr- in- charge. Note- The quoted rate includes replacement of fuel filter, oil filter,Lub filter , tank Cleaning and checking all electrical connection as per the satisfaction of Engineer- in-charge
M&L for painting of 30 HP to 90 HP capacity mono block/ centrifugal pump and motor along with connected pipe line upto 7 Mtrs with two coats of synthetic enamel paint over and including one coat of red oxide primer, including cleaning and degreasing the surface.
S&F in repairs rubber gasket 500x500mm size 6mm thick suitable for submersible/mono block pump sets & motors.
M&L for overhauling of existing star delta starter cleaning of all power contactor terminals replacement if required and renewal of unserviceable perished copper wiring, aluminium/ copper lugs, push buttons and indication lamps etc, including necessary electrical connections and testing the motor with load.
Cleaning of E/M installation yard (pump houses) by cutting bushes, shrubs/cleaning grass and other wild growth trees of upto satisfaction.
M&L for run lead joint for 150mm dia. cast iron spigot and socket pipe.
M&L for run lead joint for 100mm dia. cast iron spigot and socket pipe.
M&L for run lead joint for 80mm dia. cast iron spigot and socket pipe.
Dismantling and removal of damaged single out let fire hydrant stand post with control valve of 80mm dia. etc.,of any size.
Supply and install fire hydrant stand post single out let type made out of 80mm dia. MS pipe, 1.50 mtr long, with 90 degree bend, both ends flanged.
Refixing of fire hydrant control valve as serviceable obtained from item No. 56 above including renewal of nuts, bolts, washers and gasket with out disturbing the fire man system.
Supply and install fire hydrant control valve made out of gunmetal, single headed outlet type, 63mm dia. confirming to IS.
S&F in repairs female adaptor made of brass gun metal, 63mm dia. including all necessary welding/ brazing works without disturbing fireman lines & testing. Note: Nylon or rubber washers if any existing in the valves shall be removed before welding/ brazing and the same shall be re-inserted after completion of the job. In case of any damage, the washers shall be replaced with new ones with out any extra cost to the Govt..
M&L for joints with rubber or fibre board gasket of 10mm thick for flanged pipe joints for MS/CI/DI pipes confirming to IS using suitable nuts, bolts, & washers as required at site for 80mm dia. Pipe.
All as per item No.61 above but 100mm dia.
All as per item No.61 above but 150mm dia.
S&F 4mm thick plain sheet glass ordinary quality not exceeding 0.5 sqm each pane fixed with rubber gasket to MS hose box including removing existing broken glass.
M&L for scrapping down old painted surfaces of MS hose box, applying two coats red colour synthetic enamel paint over one coat of red oxide primer using spray jet and lettering of hose box number with white colour.
M&L for scrapping down old painted surfaces of MS fire hydrant stand post 1.6mtr long, 63mm dia, applying two coats post office red colour synthetic enamel paint over one coat of red oxide primer using spray jet and lettering of post number with white colour.
M&L for Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard
S&F in repair Battery, Maintenance free, high charge characteristic having battery capacity 90 AH.12 V , filled and factory charged for Diesel Generator Set having Capacity 25 KVA to 125 KVA. Make :- Exide and Model No.- Exide Genplus (GP110D31L) or any Equivalent Note- There should be warranty on batteries of minimum 01 years.
All items in the schedule shall be completed in all respect as directed by the Engr-in-Charge.
S V S ENTERPRISES
suresh electricals
R AND A ASSOCIATES ENGINEERS CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .