Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹47.8 LAccepted-AOC BIAMATHANG BAROO KARGIL J K | KARGIL | KARGIL | J K | 1 | Accepted-AOC L1 | |
| 2 | 2₹49.7 L+₹42,258.30 (0.86%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹53.6 L+₹4.3 L (8.64%)Rejected-Finance | 3 | Rejected-Finance L3 | |
| 4 | 4₹55.5 L+₹6.2 L (12.6%)Rejected-Finance | 4 | Rejected-Finance L4 | |
| 5 | 5₹57.9 L+₹8.6 L (17.5%)Rejected-Finance SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | 5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
12 Jun 2025, 6:00 pmClosed
GE Khumbathang
Khumbathang
GE/KHU-41/2025-26 SPL REPAIRS TO BLDG NO T-15, T-33 an T-34 AT BIAMAH, AND SPL REPAIRS TO BLDG NO T-70 , T-83 AND SPL REPAIRS OF LT UG CABLES ,STREET LIGHTS, LT POLES AND OTHER CONNECTED E/M ITEMS AT ACHINATHANG IN THE AOR OF AGE B/R II KHALTSI
2025_MES_709869_1
GE/KHU-41/2025-26
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE Khumbathang
As per tender documents
8 documents required · 8 mandatory
₹500
GE khumbathang
₹99,000
19 Jul 2025
23 May 2025
13 Jun 2025
23 May 2025
12 Jun 2025
6 Jun 2025
Amount
Dismantling wall and ceiling board of insulation boards/ slabs/ blankets any description and thickness in any posn incl cover fillets complete all as specified and directed.
M&L 9 mm thick, prelaminated particle board, interior grade, prelaminated one side with decorative choice laminated and other side balancing white lamination fixed with nails to timber frame work as in ceiling.
M&L 12 mm thick, prelaminated particle board, interior grade, prelaminated one side with decorative choice laminated and other side balancing white lamination fixed with nails to timber frame work as in wall.
Dismantling timber scantling under 40 Sqcm on flats, rails, posts, rafter, purlins etc.in unframed work complete all as specified and directed.
M&L second class soft wood, plain fillets, square or rectangular in section of area exc 13 and n exc 25 Sqcm, clean sawn, secured with nails or brands complete all as specified and directed.
M&L for I class softwood moulding as in cornices, rails etc Sectional area not exc 6 sqcm
M&L second class soft wood, plain fillets, square or rectangular in section of area exc 3 and n exc 6 Sqcm, clean sawn, secured with nails or brands as in lipping complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nanital patterns roof covering. complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.
M&L for 100 mm thick cement concrete type D-2 1:4:8 (40mm graded aggregate) as in sub base to floor or for laying of floor finishes or similar works complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, apron and laid/bedded and pointed in any mortar complete all as specified and directed.
M&L for 25 mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in floor or similar works complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) n exc 1 sq. each complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. but n exc 4 Sqm each complete all as specified and directed
S&F Second class softwood plain , solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue pinned at joints supplied and fixed complete all as specified and directed.
S&F second class soft wood 35 mm thick plain framed panelled shutters (any numbers of panels) with panels of timber flat on both sides (feather edged) or of veneered particles board medium density wood particle board with commercial face veneers,supplied and fitted to chowkats complete all as specified and directed.
S&F 30 mm thick second class soft wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
M&L for two coat of synthetic enamel paint (finishing coat) over one coat of pink primer to new wooden surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, medium weight cold rolled (including fixing with nails/screws or welded as required) complete all as specified and directed.
S&F 75 mm size mild steel butt hinges, medium weight cold rolled (including fixing with nails/screws or welded as required) complete all as specified and directed.
S&F 3 mm thick sheet glass, ordinary quality and glazed with oil putty in square n. exc 0.5 Sqm in each pane fixed complete all as specified and directed.
S&F 100 mm aluminium anodised barrel tower bolt of extruded section and fixed.
S&F Aluminium alloy anodised sliding door bolt with hasp staple ( bolt type ) 250mm long , staple (bolt type) and fixing bolt with and sliding bolts of extruded sections or cast-aluminum alloy and fixed.
S&F 150 mm aluminium anodised barrel tower bolt of extruded section and fixed.
S&F for 100 mm size Aluminium handles, cast type, anodised
S&F for 150 mm size Aluminium handles, cast type, anodised
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (Square/ rectanglar) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
S & F in repairs Aluminium alloy wire colth, 0.45mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium wire staples complete all as specified and directed
Demolition of Brickwork or stone/boulder masonry, laid in CM for ashlars facings, dressed stonework, precast concrete articles and precast concrete block walling complete all as specified and directed
M&L precast cement concrete block masonry type C1 (1:3:6) using 20 mm graded aggregate with solid block, exc. 10 Cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation etc, complete all as specified & directed
M&L 12 mm thick rendering on fair faces of brick work or concrete surface in cm 1:6 to be finished even and smooth without using extra cement complete all as specified and directed.
M&L 15 mm thick cement plaster in CM 1:4 on brick work or concrete surface other than fair face or brick work and finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls including cornices, pillasters etc, and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls including cornices, pillasters etc, and applying two coats of oil emulsion distemper over and including one coat of chalk whiting preparatory to distempering complete all as specified and directed.
Surface dressing n exc 15 cm deep hard and dense soil complete all as specified and directed.
M&L Hard core broken stone boulders of gauge not exceeding 63mm broken stone deposited spearding and levelled in layers not exceeding 15cm thick watered and well rammed to a ture surfaces complete all as specified and directed.
M&L for 100mm thick cement concrete type D-2, 1:4:8 (using 40mm aggregate) in floors complete all as specified and directed
M&L for 25mm thick plain cement concrete type B-0, 1:2:4 (using 12.5mm aggregate) under tile as subbase complete all as specified and directed
M&L Vitrified ceramic tiles Brown colour with wooden texture (match with existing tiles) 10mm thick (Square/rectanglar) area of each tile not exceeding 0.36 sqm in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out hard dense soil complete all as specified and directed.
Removal of excavated soil to a distance exc 50 and n exe 250m depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified
S&F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roof, walls etc with grade of zinc coating 275 complete all as spd and as directed by Engr-in-charge.
M&L for preparation of newly or previously untreated surfaces of steel or iron work over 10 cms width or girth and applying two coats of synthetic enamal paint over a coat of red oxide Zink chrome primer complete all as spd and as directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed.
M&L Coloured chequred cement concrete tiles of size 300x300x20mm,set, jointed & pointed in neat cement slurry with grey cement & pigment in floors thick laid over and incl 20mm thick screed bed in CM (1:4) bedded and jointed in neat cement slurry complete all as specified & directed.
Taking down Shutters of any description exc 1 sq. m but n.exc 2 Sqm each complete all as specified and directed
Taking down Shutters of any description n exc 1 sq. m each complete all as specified and directed
Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface etc.
Material and labour for point wiring with 1.5 sqmm cable FRLS PVC insulated, unsheathed copper multistranded conductor, 1100 V grade of size 1.5 sqmm incl 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor as earth wire ( green in clour) and connected to common earthing with PVC heavy duty casing caping/PVC conduit ISI marked as rquired at site along with CI/MS/PVC sunken boxes of size as required at site along with plastic laminated hylom sheet cover 3 mm thick for fixing swiches , sockets regulators incl accessories and making good the disturbed surfaces of wall/ ceiling etc for the following : -
One light point/ one fan point/ Bell Point controlled by one switch
One 3 pin socket outlet, 6 Amp independent
One 3 in socket outlet 6 Amps on same board
Supply and fix in repair switch piano flush type 6 Amps all as specified
Supply and fix in repair socket 6 amp all as specified
S & Fin repair Ceiling rose 3 terminal flush type 6 Amps,250 volts AC ISI marked
S&F in repair batten holder 230 volt all as specified and directed .
All as per item No 2 above but for point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy duty ISI marked /heavy duty conduit ISI marked as required at site alongwith along with CI/MS/PVC sunken boxes of size as required at site along with plastic laminated hylom sheet cover 3 mm thick for fixing swiches , sockets regulators incl accessories and making good the disturbed surfaces of wall/ ceiling etc along with one run of 2.5 sqmm cable as earth wire ( green in colour ) and connected to common earth all as specified.
S & F in repair socket 5 pin 16 amp complete all as specified and directed.
S & F in repair switch 16 Amps complete all as specified and directed.
S&F in replacment of decorative ultra slim polycarbonate LED 4 feet long 20/22 watts with THD less than 15% very high efficiency suited for T-8 tube luminare with system efficacy 110 lumen per wattsb , high quality poly carbonate end cap in white finish and snap fitted to the housing, inbuilt driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete all as specified and directed. .
S&F in replace LED building security light fitting 30 watts made of pressure diecast aluminium housing with acrylic cover as diffuser with IP65 and IK -07 protection , THD<10%, lumen output >= 110 lumen per watts with integrated lectronic driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete all as specified and directed.
S&F in replacing GI mounting pipe of building security lights of size 32 mm to 40 mm size upto 1.2 mtr length bend into sizes incl mounting clamps made of MS flat saddles, nut bolt and washers all as specified and directed .
M&L for replacing LED bulk head fittings of wattage 6 to 13 watts deigned for modern homes , glare free lights and easy to install snapfit installer complete including making good of surface complete all as specified and directed.
Taking down old u/s submain wiring of any sizes complete incl conduits/PVC casing n caping all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 4 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with one run of 4 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed. Note : 1. Two run of main copper conductor 4 sqmm size , one run of 4 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length . 2. Proper colour coding shall be maintained as per IS code.
S&F in replacing distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed incl taking down old one
S&F in repair MCB SPN 63 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed incl taking down old one
S&F in repair MCB single pole, 6 to 32 Amp 240 volt C curve 10 KA breaking capaity complete all as specified and directed incl taking down old one
S&F distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface incl making good of surface complete all as specified and directed incl taking down old one
S&F MCB SPN 40 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed incl taking down old one
S&F XLPE insulated armoured heavy duty electric power cable 1100 volt grade 10 sqmm 2 core complete all as specified and directed ( laid on wall)
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor ,served with inner sheathing of PVC tape and overall PVC sheathed in service connections two core of size 16 sq mm flat or circular complete all as specified and directed
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm PVC (FRLS-H) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLSH) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl all fittings such as Tee, connector pieces, L-junction etc on joints including CI/MS/PVC sunk boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light/fan/bell point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed.. Notes : (a) Wiring shall be done by using proper colour coding.(b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC casing 'N' cappingshall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Description all as per serial item No 03 here-in-before but one 5 pin socket outlet, 5 amps on the same board complete all as specified and directed.
Description all as per serial item No 03 here-in-before but one 5 pin socket outlet, 5 amps, independent complete all as specified and directed.
Description all as per serial item No 03 here-in-before but for one 5 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed.
S&F switch piano, flush type single pole one way 6 Amp, 240 volts ISI marked complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin, 6 Amp ISI marked complete all as specified and directed.
S&F socket outlet 3 pin, 6/16 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed.
S&F switch piano, flush type single pole, one way 16 Amps, 240 volts ISI marked complete all as specified and directed.
S&F ceiling rose, 3 terminal surface type complete all as specified and directed.
S&F angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and Fixing LED bulb of 15 watt complete all as specified and directed. Make -Bajaj or Equivalent Cat Part- IVORA PLUS HB LED LAMP 15W CDL B22
Supply & fixing surface /wall mounted light fitting pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed.
Supply and Fix LED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP66 complete all as specified and directed.Make-Crompton Greaves /Philips/Bajaj
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCB's should be same make.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S &F of SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level ,connected to galvanised earth lead wire 4.0mm by means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrode and including GI pipe light grade 40mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT bars at 140mm C/C both ways, with lifting handle, watering pipe of GI medium grade 40mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and all as specified.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in hard soil complete all as specified and directed. (cable shall be laid 60 cm below ground level )
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
Supply and laying sand as in cushioning for under groung cables laid in trenches with layer of sand 8 cm thick before laying of cable and 15 cem after laying of cable incl spreading, levelling and hand punning complete all as specified and directed .Note: Only punned thickness 18cm shall be measured and paid
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type-1, flat, size 250mm x 150mm x 40mm complete all as specified and directed
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 10 Sq mm 2 core complete , all as directed .
Excavation in trenches exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for pole including getting out in hard soil complete all as specified and directed.
Taking down old unservieable LT ug cable any size.
Supply and fixing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor cable 1100 volts grade laid in trenches / passing through GI pipe / on pole / on wall of size 06 sq mm 2core complete all as specified .
Supply and fixing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor cable 1100 volts grade laid in trenches / passing through GI pipe / on pole / on wall of size 50 sq mm 3.5 core complete all as specified .
Supply and fixing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor cable 1100 volts grade laid in trenches / passing through GI pipe / on pole / on wall of size 70 sq mm 3.5 core complete all as specified .
Supply and fixing G I tubing 40 mm dia light grade galvanised with all fittting and fixed fix on wall ceiling or laid in floors complete all as specified and direceted at site .( for cable protection )
Taking down old Unserviceable security light fitting/flood light fitting any size complete all as specified and directed .
S&F in replace LED building security light fitting 35 watts made of pressure diecast aluminium housing with acrylic cover as diffuser with IP65 and IK -07 protection , THD<10%, lumen output >= 110 lumen per watts with integrated lectronic driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete incl incl GI pipe 32 mm size bend into size 1.2 mtr length along with mounting clamps , nut bolt , washers complete taking down of old CFL/bulb fittings all as specified and directed.
S&F LED security light fitting 60 watts made of pressure diecast aluminium housing with acrylic cover as diffuser with IP65 and IK -07 protection , THD<10%, lumen output >= 110 lumen per watts with integrated lectronic driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete incl GI pipe 32 mm size bend into size 1.2 mtr length along with mounting clamps , nut bolt , washers complete for mounting on LT pole 9 Mtr incl taking down of old CFL/bulb fittings all as specified and directed.
S&F in replacement LED flood light 100 watt 230 volts AC outdoor type with thermal management in multiple optics and equiped with IP66 protection,with impact and corrosion resistant complete with driver and lamp and making necessary connections complete all as speciified and directed.
S&F in replacement post top lantern/bollard of type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant aluminium cast body complete with driver and lamp complete with necessary connections complete all as speciified and directed.
M&L for FRP Junction Box fixed with hinge of size not less than 200x150x100cm , with closing arrangement incl 10 Amps three pase and Neutral aluminium bus bar , internally wired nut bolts with suitable size of copper conductor and incl one No MCB SP 6 Amps mounted on din rail, complete all as specified and directed by Engr-in-Charge. Make Syntex /Hensel/ National
S & f in replacement PVC insulated stranded copper conductor FRLS 1.5 sqmm for connectionfrom pole junction box to connector of street light fitting complete all including taking down all as specified and directed.( for street light junction box to connector of light fitting)
Supply installing, testing and commissioning of Bus bar junction box panel outdoor kiosk type factory made of angle iron 65mmx 65mmx 6mm on all side welded to 3.15 mm thick CRCA sheet steel for outer compartment and 2.0 mm thick for inner compartment with openable shutteron both sides ( front and rear) , having locking arrangement totally enclosed weather proof outdoor spray painted internally and externally with two coats of synthetic enamel paint over a coat of primer suitable for 440 volts, 3 phase, 4 wire, 50 Hz with Aluminium bas bar of capacity 200 Amps AC supply, electrically connected as per norms and fitted with following accessories all as specified and directed by the Engr-in Charge. (Note:- Bus bar junction box shall be mounted on PCC 1:2:4 type B-1 with 20 mm graded stone aggregate foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm) . Note:- Drg of bus bar junction box panel shall got approved before execution at site. INCOMMER/OUT GOING Incoming MCCB, 415V, 4 pole, 100 Amps, 25 KA, Ics =100% Icu -01 nos, Indicator Lamp-01 Set (Set of three)
S&F in replacing LT cable junction boxes out of polycarbonate with glass fibre reinforced and size not less than 104x104x70 mm ( cable size upto 4 sqmm ) . The polycarbonate junction box shall be environmental friendly , recyclable , halogen and sylicon free, anti acid and anti corrosive with IP rating IP 67/69 in accordance with IEC 60529 weather proof UV resistant , rain water proof and temparature resistant . The gasket material of junction box shall be polyurethane and internally embedded. The junction box comprises of DIN rail and terminal for 3 phase . The degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08 incl 5 pole terminals comany fitted and chromium plated clamps complete all as specified and directed. ( For post top/bollard connection) Cat part no :- KF 0404 B of Hensel or equivalent make in Seimens/GE/ABB
M&L for replacing 3 core copper flexible cable 1.5 sqmm PVC sheathed FRLS complete incl taking down all as specified and directed .( For connection to flood light fitting)
Supply and erection truely vertical position steel tubular swaged pole complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 mtr long), complete all as specified and directed by Engr-in-Charge.
M&L for repair/replacing PCC 1:3:6 using 20 mm graded stone aggregate of required shape incl necessary form work , rendering with cement mortar 1:4 finishing complete incl two coat of distumbering as per approved colour duly making surface preparation and two coat of cement primer all as specified and directed. of post top lantern/bollards incl necessary form works
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25X4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
Deduct Credit for Demolished/Dismantled material Rs (-) 89,235.46 (Minus) as listed in Schedule 'A' Sec-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
M/S ABBAS ENTERPRISES (BID ID -3318208)
M/S Haji Hadi (BID ID -3318306)
M/S M A ENTERPRISES (BID ID -3318926)
M/S SUN RISE BUILDERS (BID ID -3319496)
M/S MOHD FAROOQ (BID ID -3320621)
M/S TAMCHOS GURMATH (BID ID -3321345)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .