Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.9 LAccepted-AOC HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹30.7 L+₹1.9 L (6.71%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹32.7 L+₹3.9 L (13.6%)Rejected-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹34.3 L+₹5.6 L (19.4%)Rejected-Finance 38 41 28 104 AREA INDUSTRIAL ESTATE VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹34.8 L+₹6.0 L (20.9%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| Sl No | Description | Qty | Unit | KALPANA INFRA PROJECTS L7 | SRIVALLI ENGINEERS L3 | SREE DURGA INFOTECH L2 | HARSHITHA INFRA L5 | M/S Jayalakshmi Constructions L4 | VIJAYA DURGA CONSTRUCTIONS L6 | GVR CONSTRUCTIONS L8 | SAMPATH ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down unserviceable main switches, DBs, bus bars chambers, MCB/MCCB Enclosures any capacity including all fittings and fixtures such as MCBs, isolator, MCCBs, MCB protected Power socket etc and removing from site complete all as specified and directed. | 134 | Each | 50 ₹6,700 | 80 ₹10,720 | 50 ₹6,700 | 60 ₹8,040 | 40 ₹5,360 | 90 ₹12,060 | 150 ₹20,100 | 20 ₹2,680 Lowest |
| 2.00 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. | 300 | RM | 50 ₹15,000 | 30 ₹9,000 | 20 ₹6,000 | 20 ₹6,000 | 20 ₹6,000 | 25 ₹7,500 | 100 ₹30,000 | 10 ₹3,000 Lowest |
| 3.00 | M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length) | 100 | RM | 450 ₹45,000 | 170 ₹17,000 | 140 ₹14,000 | 160 ₹16,000 | 130 ₹13,000 Lowest | 180 ₹18,000 | 250 ₹25,000 | 150 ₹15,000 |
| 4.00 | M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length) | 200 | RM | 500 ₹1,00,000 | 420 ₹84,000 | 390 ₹78,000 | 400 ₹80,000 | 340 ₹68,000 Lowest | 440 ₹88,000 | 550 ₹1,10,000 | 350 ₹70,000 |
| 5.00 | S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 1.5 sqmm complete all as specified and as directed. | 300 | RM | 650 ₹1,95,000 | 78 ₹23,400 | 65 ₹19,500 | 60 ₹18,000 Lowest | 180 ₹54,000 | 70 ₹21,000 | 100 ₹30,000 | 70 ₹21,000 |
| 6.00 | S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 2.5 sqmm complete all as specified and as directed. | 200 | RM | 650 ₹1,30,000 | 125 ₹25,000 | 100 ₹20,000 Lowest | 100 ₹20,000 Lowest | 200 ₹40,000 | 105 ₹21,000 | 150 ₹30,000 | 100 ₹20,000 Lowest |
| 7.00 | S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 4.0 sqmm complete all as specified and as directed. | 200 | RM | 45 ₹9,000 Lowest | 165 ₹33,000 | 145 ₹29,000 | 125 ₹25,000 | 230 ₹46,000 | 140 ₹28,000 | 200 ₹40,000 | 130 ₹26,000 |
| 8.00 | S&F MCB protected power socket modular type with Steel Enclosure including 20 Amps MCB SP complete all as specified and as directed | 80 | Each | 2,500 ₹2,00,000 | 850 ₹68,000 | 700 ₹56,000 | 650 ₹52,000 Lowest | 700 ₹56,000 | 780 ₹62,400 | 900 ₹72,000 | 700 ₹56,000 |
| 9.00 | S&F MCB protected power socket (3P+N+E) with Steel Enclosure including 32 Amps MCB FP complete all as specified and as directed | 2 | Each | 2,500 ₹5,000 | 2,200 ₹4,400 | 2,000 ₹4,000 | 3,200 ₹6,400 | 1,000 ₹2,000 Lowest | 3,000 ₹6,000 | 3,500 ₹7,000 | 2,500 ₹5,000 |
| 10.00 | S & F Vertical TPN DB double door,IP43 for provision of MCCB upto 250 A as incomer ,8 way with 200 A rating busbar complete all as specified and as directed. | 5 | Each | 4,599 ₹22,995 | 8,000 ₹40,000 | 7,500 ₹37,500 | 8,850 ₹44,250 | 3,200 ₹16,000 Lowest | 8,900 ₹44,500 | 9,500 ₹47,500 | 8,000 ₹40,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Nov 2025, 6:00 pmClosed
GARRISON ENGINEER (NAVAL BASE)
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
REPAIR/REPLACEMENT AND MAINTENANCE OF MISC E/M EQUIPMENT INCLUIDNG BUILDING SECURITY LIGHTS WITH FITTING/FIXTURES AND ALLIED WORKS OF E/M INCLUDING INDOOR LT PANELS, LIGHTNING PROTECTION ,DISTRIBUTION BOARD ,FLOOR PANELS,INSULATION MATS, ACS,
2025_MES_736524_1
C/8545/25-26/E8 TOKEN 66 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹90,000
Yes
3 Jan 2026
23 Oct 2025
20 Nov 2025
23 Oct 2025
13 Nov 2025
6 Nov 2025
Amount
Taking down unserviceable main switches, DBs, bus bars chambers, MCB/MCCB Enclosures any capacity including all fittings and fixtures such as MCBs, isolator, MCCBs, MCB protected Power socket etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 1.5 sqmm complete all as specified and as directed.
S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 2.5 sqmm complete all as specified and as directed.
S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 4.0 sqmm complete all as specified and as directed.
S&F MCB protected power socket modular type with Steel Enclosure including 20 Amps MCB SP complete all as specified and as directed
S&F MCB protected power socket (3P+N+E) with Steel Enclosure including 32 Amps MCB FP complete all as specified and as directed
S & F Vertical TPN DB double door,IP43 for provision of MCCB upto 250 A as incomer ,8 way with 200 A rating busbar complete all as specified and as directed.
S & F Vertical TPN DB double door,IP43 for provision of MCCB upto 160 A as incomer ,4 way with 200 A rating busbar complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 3 Pole, 100 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 4 Pole, 100 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 4 Pole, 125 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release , 415 Volt, 25 KA, 4 Pole, 200 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release 415 Volt, 25 KA, 4 Pole, 250 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release 415 Volt, 25 KA, 4 Pole, 400 Amps Capacity complete all as specified and as directed.
S & F in repair Spreaders, 4 pole suitable upto 250 Amps complete all as specified and as directed.
S & F in repair Spreaders, 3 pole suitable upto 250 Amps complete all as specified and as directed.
S & F MCCB enclosure IP 43 with solid neutral link suitable for 4 pole MCCBs complete and making good disturbed surfaces complete all as specified and as directed. Note :- MCCB will be measured and paid under respective item
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying well burnt bricks, fly ash bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
S & F in repair IP 66 junction box made of impact resistance polycarbonate & heat resistant materials of size 200x160x98mm mm, dust proof, water tight, light weight, acid resistant, corrotion proof insulated and shock proof, fire retardant, self extinguishing, helogen & silica free non toxic material, UV resistant with internally embedded gasket and fitted with required terminals alongwith type test certificate and veryfied by glow-wire test in accordance with IEC60695-2-11 complete all as specified and directed directed. (Make : HENSEL, Cat No : KF9255 or equivalent model of make as per list of manufacturer)
S & F in repair LED outdoor Security light fittings, Min IP 65 rated, aluminium die cast housing with powder coating, pole mounted, 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 70 Ra, 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repair 32 mm dia light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket arm 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed complete all as specified and directed.
S & F in repair LED outdoor Flood light fittings,50 Watt, 230 Volts AC , made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED outdoor Flood light fittings, 70 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED outdoor Flood light fittings, 100 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED outdoor Flood light fittings, 150 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair circular highbay LED light fittings, 200 Watt, 230 Volts AC with toughened glass, upto150 lm/W with10 kV SPD with IP66 protection with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED light fittings, 1x4', 40 Watt, 230 Volts AC with high performance, commercial grade solution industrial application with impact and corrosion resistant, IP65 rating complete with driver and lamp and with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repair 25 Watt, 230 Volts AC Post Top Lantern, outdoor type with decorative post top for 360 Degree indirect light, IP 65 protection with impact and corrosion reisitant complete with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed.
S & F in repair 40 Watt, 230 Volts AC Post Top Lantern, outdoor type with decorative post top for 360 Degree indirect light, IP 65 protection with impact and corrosion reisitant complete with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed.
S & F in repair 10 Watt, 230 Volts AC, Inverted Pyramid Tripod type LED Bollard light fittings with soft 360 light distribution, Min IP 65 rated, outdoor type with decorative light with impact and corrosion resistant with driver and lamp and with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp and making good disturbed surfaces complete all as specified and directed.
S & F in repair 10 Watt, 230 Volts AC, LED Bollard light fittings, efficient light distribution, Min IP 65 rated, outdoor type with decorative light with impact and corrosion resistant with driver and lamp and with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp and making good disturbed surfaces complete all as specified and directed.
S & F in repair 40mm bore, Steel water tubing, galvanised, medium grade with all fittings laid in trenches etc complete all as specified and directed.
S & F in repair 50mm bore, Steel water tubing, galvanised, medium grade with all fittings laid in trenches etc complete all as specified and directed.
S & F in repair Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
S & F in repair starter with push button switch with 1NO+1NC complete working on AC supply upto 16 Amp capacity complete all as specified and directed.
Disconnecting / dismantling (Electrically and mechanically) 3-ph, 440 volts ,50 Hz electrical motor from monoblock pump set of 2 HP capacity and shifting to workshop , opening the motor and cover,taking out motor and burnt stator winding and rewind the motor with appropriate gauge weight and turns of super enamelled copper wire using proper insulating material varnishing with class-1 varnish,reassembling the motor completely and connecting and testing complete all as specified and directed. Note : (i)The cost of minor spare parts require shall deemed to be included in quoted rate. (ii) The cost of transportation from site of work to workshop and back after rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor's workshop and shall be re-fixed at site within 05 days after taking down from site. Any delay after 05 days shall be penalised @ Rs. 100.00 per day.
Supply, fix, installation and commissioning BLDC ceiling fan of less noise, silent operation, speed controlable by regulator, light colour, conforming to IS-374-2019, 1200 mm sweep, 230 Volts, BEE 5 Star rating, any Govt recognised Lab tested, power factor >0.94 Wattage and not more than 35 Watt, air delivery not less than 215cmm and all accessories such as down rod etc and connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan and fixing in existing position including taking down existing unserviceable ceiling fan of any descriptions and deposited at MES store yeard complete all as specified and directed. (Note: Ceiling fan should have minimum 2 years manufacturer's warranty) (Make : USHA /Havell's/ Bajaj/ CG)
S & F Exhaust fan, 600 mm sweep, heavy duty, metal body ,900 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
S & F Exhaust fan, 450 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
S & F Exhaust fan, 300 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
S & F PVC body Exhaust fan, 250 mm sweep, AC, single phase, 1200 RPM complete with all accessories and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
S&F in repair of 10 to 16 Sqmm size pin type aluminium thimble for terminate electrical wires/cables connection in a professional manner to minimizing current leakage and hence avoids overheating or electrical failure due to loose connection complete all as specified and directed.
S&F in repair of 25 to 35 Sqmm size pin type aluminium thimble for terminate electrical wires/cables connection in a professional manner to minimizing current leakage and hence avoids overheating or electrical failure due to loose connection complete all as specified and directed.
S&F in repair of 50 Sqmm size pin type aluminium thimble for terminate electrical wires/cables connection in a professional manner to minimizing current leakage and hence avoids overheating or electrical failure due to loose connection complete all as specified and directed.
S&F in repair of 4-10 Sqmm size copper thimble for terminate electrical wires/cables connection in a professional manner to minimizing current leakage and hence avoids overheating or electrical failure due to loose connection complete all as specified and directed.
M & L for complete checking of LT panel board installed at various locations of MD ACCN block, checking of electrical connections such as thimbles, spring nuts, rubber gasket, window glass cover and refixed the same properly in position including replacement of such minor items (if any) as required at site complete all as directed by the Engr-in-Charge. Note : Cost of minor items will deemed to be included in quoted rate.
Material and Labour for preparation of old metal surfaces of Panel Boards after complete removal of existing painting over 10cm width or girth not otherwise described and applying two coats of enamel paint (1st quality) of simens grey colour over a coat red oxide zinc chrome primer and marking the Qtr No, Panel Board No in front side complete all as specified and directed by engineer in Charge. (Note: Adjoing areas there to properly covered befor painting. Adjoing areas, floor, walls are to cleaned free of paint spillage after painting work. If Paint spill is not cleaned to match with exsting surface a panel recovery @ Rs.200/- per location will be made from payments due to the contractor).
S & F in repair UPVC Panel cable trunking casing and capping of size 100x75 mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S & F in repair UPVC Mini/Maxi trunking profile with cover of size 50x50mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S&F in repair transparent window glass cover of size 150mmx150mm, 3 mm thick sheet glass suitable for LT panel complete all as specified and directed
S & F in repair indication lamp (Red,Yellow,Green),22.5 mm dia monitor, 240 volt Ac, suitable for panel board complete all as specified and directed.
S & F in repair LED indication lights complete set of two (Red,Green),including necessary connection complete all as specified and directed.
S & F in repair avaiation obstruction light, LED type integral light comprising of aluminium housing with polycarbonate enclosure with LED lamp 10 watt ,driver and all accessories and connection complete all as specified and as directed. Make: Bajaj Cat Part No BGAV 302LED or equivalent model of make as mentioned in list of manufacturer under PS
S & F in repair 20W, LED Flame proof lights with IP 65 protection complete with all accessories all as specified and as directed. (Make : Model no EXTN1LT8-16/20 of Crompton or equivalent of make as per List of Manufacturer's)
Taking down old aluminium bus bar from existing LT panel board disconecting the cable and supply and fixing new copper bus bar of size 50 mmx10 mm including all connected accessories such as copper thimbles etc,reconnect the cable with new bus bar complete all as specified and directed.
S & F in repairs electronic Control Card i.e PCB boards non inverter type indoor/outdoor suitable for 1.5 / 2.0 TR capacity Split/Tower AC’s as per the existing make and specifications and making connections etc complete all as specified and as directed.
S & F in repairs electronic Control Card i.e PCB boards inverter type indoor/outdoor suitable for 1.5 / 2.0 TR capacity Split/Tower AC’s as per the existing make and specifications and making connections etc complete all as specified and as directed.
Note :-1.In compliance with condition 26 of IAFW-2249 (General Condition of Contract) for safety purpose Electrician employed by the contractor for this work shall have Industrial training Institute pass certificate from a recognized institute in relavant trade with 3 years experience in relevant field or 10th Class pass Certificate having 10 years of practical experience in relevant field . Before commencement of work contractor shall submit the name of electrician alongwith necessary documents in support of their qualification and practical experience to the Engineer-in-Charge for approval of accepting officer. Incase any changes of manpower require during currency of tender ,fresh approval shall be taken from accepting officer. 2. Before commencement of work contractor shall submit valid electrical license in accordance with Cl No 23 of Sch “A” Notes of contract agreement. 3. Supervisor for execution of above mentioned work employed by the contractor shall also posses supervision certificate of competency issued by concerned State Govt where the works are to be executed
SREE DURGA INFOTECH (BID ID -3473305)
SRIVALLI ENGINEERS (BID ID -3473266)
M/S Jayalakshmi Constructions (BID ID -3473851)
HARSHITHA INFRA (BID ID -3473785)
VIJAYA DURGA CONSTRUCTIONS (BID ID -3473898)
KALPANA INFRA PROJECTS (BID ID -3469661)
GVR CONSTRUCTIONS (BID ID -3473112)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .