Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC 1849 JUGRAJPUR SACHENDI KANPUR KANPUR NAGAR UTTAR PRADESH 208023 UDYAM UP 43 0012110 | KANPUR NAGAR | UTTAR PRADESH | 208023 | ₹1.8 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.9 CrRejected-Finance H NO 685 NEAR GOVT SR SEC SCHOOL PAKASMA ROHTAK HR 124401 | PAKASMA | ROHTAK | HARYANA | 124401 | ₹1.9 Cr | L2 | Rejected-Finance QUOTED RATES ARE ON HIGHER SIDE |
| 3 | L3₹2.0 CrRejected-Finance 161 VPO RAJLU GARHI GANAUR 131101 | SONIPAT | HARYANA | 131101 | ₹2.0 Cr | L3 | Rejected-Finance QUOTED RATES ARE ON HIGHER SIDE |
| 4 | L4₹2.2 CrRejected-Finance H NO 134 SECTOR 6 HANSI 125033 HARYANA HISAR | HANSI | HISAR | HARYANA | 125033 | ₹2.2 Cr | L4 | Rejected-Finance QUOTED RATES ARE ON HIGHER SIDE |
| Sl No | Description | Qty | Unit | Vijay Contractor L2 | Rajkumar L4 | DALAL CONSTRUCTIONS AND MAN POWER SOLUTIONS L3 | M/s Balaji Construction Co. L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | (NS item) Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked
HDPE pipe of 225 mm outer dia of PE-80 grade and PN-4 for water supply as per IS 4984-2016
(amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro
testing (including the cost and conveyance of water to site for testing) and commissioning as per
Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid
separately. Rate includes cost of all specials like bends , tees required during laying of pipe line along
required alignment. | 3,507.64 | Metre | 800 ₹28.1 L | 1,270 ₹44.5 L | 1,200 ₹42.1 L | 1,100 ₹38.6 L |
| 2.00 | (NS item)Providing, laying and installation of 100 mm dia G.I. pipe suitable for submersible solar pumping set, including all fittings such as flanges, bends, nipples, nuts and bolts, jointing material, cutting, threading, lowering, alignment, testing and commissioning, complete in all respects, as per specifications and to the satisfaction of the Engineer-in-Charge. | 375 | Metre | 850 ₹3.2 L | 1,094 ₹4.1 L | 1,050 ₹3.9 L | 800 ₹3 L |
| 3.00 | (NS item)“Supply, installation, testing and commissioning of submersible solar pumping set of 7.5 HP capacity, DC type pump with UPSC controller, including all accessories and electrical/mechanical components, complete in all respects, with 5 years warranty of the complete solar pumping set, as required by the New and Renewable Energy Department, Haryana and HAREDA, as per approved specifications and directions issued by HAREDA and Director, Supplies and Disposals, Panchkula, Haryana vide memo No. 100/HR/RC/E-5/2024-25/4565-4585 dated 30.05.2025, to the entire satisfaction of the Engineer-in-Charge.” Note:- The procurement sahll be made from approved agencies as per DGSandD memo No. 100/HR/RC/E-5/2024-25/4565-4585 dated 30.05.2025 | 15 | Nos. | 3,95,308 ₹59.3 L | 3,54,892 ₹53.2 L | 4,87,000 ₹73.0 L | 3,20,000 ₹48 L |
Tender Value
₹2.1 Cr
EMD Value
₹4.2 L
Closing Date
16 Mar 2026, 11:00 amClosed
PARSHANT KUMAR
W.S.Division Gohana
dewatering of flood water and lowering of SSWL
2026_HRY_506210_1
202647475524 753A 428D 94DB 912B82796BF3210IRR
Open Tender
Civil Works
180 days
BANWASA CHHAPRA
3 documents required · 3 mandatory
₹15,000
₹4.2 L
Yes
11 Apr 2026
3 Mar 2026
16 Mar 2026
3 Mar 2026
16 Mar 2026
3 Mar 2026
3 Mar 2026 - 13 Mar 2026
(NS item) Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of 225 mm outer dia of PE-80 grade and PN-4 for water supply as per IS 4984-2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends , tees required during laying of pipe line along required alignment.
(NS item)Providing, laying and installation of 100 mm dia G.I. pipe suitable for submersible solar pumping set, including all fittings such as flanges, bends, nipples, nuts and bolts, jointing material, cutting, threading, lowering, alignment, testing and commissioning, complete in all respects, as per specifications and to the satisfaction of the Engineer-in-Charge.
(NS item)“Supply, installation, testing and commissioning of submersible solar pumping set of 7.5 HP capacity, DC type pump with UPSC controller, including all accessories and electrical/mechanical components, complete in all respects, with 5 years warranty of the complete solar pumping set, as required by the New and Renewable Energy Department, Haryana and HAREDA, as per approved specifications and directions issued by HAREDA and Director, Supplies and Disposals, Panchkula, Haryana vide memo No. 100/HR/RC/E-5/2024-25/4565-4585 dated 30.05.2025, to the entire satisfaction of the Engineer-in-Charge.” Note:- The procurement sahll be made from approved agencies as per DGSandD memo No. 100/HR/RC/E-5/2024-25/4565-4585 dated 30.05.2025
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
(HSR item) [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
(HSR item)[20.11.2]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 2. 100 mm i/d [Through Rate]
(HSR item) [20.14.3]Providing and fixing cast iron double air valves of size given below marked with IS: 14845 including carriage, loading, unloading stacking, handling, re-handling etc., drilling, tapping, screwing in valves connections complete in all respects to the satisfaction of Engineer-in- charge. (Rate is same for 65mm/80mm/100 i/d pipes) 3. 100 mm i/d [Through Rate]
(HSR item) [20.4.2]Jointing cast iron socketed pipes, valves and specials with run lead caulked joints excluding cost of lead and yarn but including cost of labour, fuel and tools etc. Tested complete. 2. 100 mm i/d pipe [Through Rate]
(HSR item)[20.5.2]Making flanged joints for cast iron pipes, valves or specials 2. 100 mm internal diameter of pipe, values or specials [Through Rate]
(HSR item)[20.68.1]Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 1. Up to 300mm dia [Through Rate]
(HSR item) [21.28]Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge [Through Rate]
(HSR item)[21.95.5]Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 5. 600 mm [Through Rate]
(HSR item)[21.95.8]Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 8. 900 mm [Through Rate]
(HSR item)[22.162.1.1]Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 1.1. 100 mm diameter Class I [Through Rate]
(HSR item) [22.162.4.1]Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 4.1. 200 mm diameter Class I [Through Rate]
(HSR item)[33.15]Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in-charge. [Through Rate]
(HSR item)[33.16.3]Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 3. 200 mm dia [Through Rate]
(HSR item) [33.17.1]Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 1. 100 mm clamp [Through Rate]
(HSR item)[33.19]Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `V` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge. [Through Rate]
(HSR item)[33.6.1.1]Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 1.1. All types of soil 300 mm dia [Through Rate]
(HSR item) [33.9.3]Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 3. 200 mm nominal size dia [Through Rate]
(HSR item)[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
(HSR item) [4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate]
(HSR item)[4.16.1.3]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.3. All kind of soil Pipes, cables etc, exceeding 300 mm dia but not exceeding 600 mm dia. [Through Rate]
(HSR item) [4.16.1.4]Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.4. Pipes, cables etc, exceeding 600 mm dia but not exceeding 900 mm dia. [Through Rate]
(HSR item) [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate]
(HSR item) [6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate]
(HSR item)[6.1.4]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) [Through Rate]
(HSR item) [6.29.1]Centering and shuttering including strutting, propping etc. and removal of form work for : 1. Foundations, footings, bases for columns [Through Rate]
(HSR item)[6.29.3]Centering and shuttering including strutting, propping etc. and removal of form work for : 3. Columns, piers, abutments, pillars, posts and struts [Through Rate]
(HSR item)[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]
(HSR item)[6.44]Providing, hoisting and fixing up to floor four level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor four level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate]
(HSR item)[7.21.3]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 3. Cement mortar 1:3 (1 cement : 3 coarse sand) [Through Rate]
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
techsummary_584941.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
BOQ_584941.xls
BOQ • 0.30 MB
OT0153964.pdf
Other Document • 0.55 MB
Download all tender documents and submit your bid