| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC 00 SIMENT ROAD SONKH DEHAT MATHURA UTTAR PRADESH 281123 | MATHURA | UTTAR PRADESH | 281123 | ₹27.6 L | L1 | Accepted-AOC Being lowest and reasonable bidder |
| 2 | L2₹28.4 L+₹80,620 (2.92%)Rejected-Finance | ₹28.4 L+₹80,620 (2.92%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹29.8 L+₹2.3 L (8.19%)Rejected-Finance | ₹29.8 L+₹2.3 L (8.19%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹30.5 L+₹2.9 L (10.6%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹30.5 L+₹2.9 L (10.6%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹30.8 L+₹3.2 L (11.6%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹30.8 L+₹3.2 L (11.6%) | L5 | Rejected-Finance Other than L1 bidder |
| Sl No | Description | Qty | Unit | satpal and brothers L4 | KULBHUSHAN AGGARWAL L8 | kailu construction co L5 | INDERJIT SINGH L3 | JAI DURGA CONSTRUCTION CO L7 | Standard engineers L6 | M/s Swastik Engineers L2 | Gupta Trading Co L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour charges only for inspection of defective step down transformer of 25 KVA to 400 KVA, 11 KV / 0.433 of various make , model mounted on plinth/floor/ pole mounted, indoor/outdoor type, step opening, removing the top cover of transformer, detecting the fault, rectfying the defect at site (Samba, Dayalachak & Galak) except major fault of burnt winding or other. If found winding burnt transport to workshop for repairing. The following tasks if required will be performed :-
(a) Step opening of the transformer and removing the transformer top cover for checking/rectified the faults of the transformer.
(b) Replacement of defective HT/LT bushes, brass spindles bushing to secondary winding connected copper terminals etc.
(c) Refixing the transformer top cover with OEM recommended size gasket of minimum thickness 5mm, nuts, bolts and washers if oil filing pipe cover damages replaced with suitable size of steel cover as per existing model and size the payment for gasket paid separately under relevant items of CA schedule.
(d) Testing of transformer magnetic balance test, HT/LT winding insulation test complete and produce testing certificate with the sign of contractor, Engineer-in-Charge, Technician deputed by contractor, the payment of any RAR/Bill shall not be released to the contractor without test certificate.
Note : (i) In case of replacement of LV / HV bushing / spindles / tap changer etc, will be measured and paid for separately under relevant items of CA as supply only items. (ii) Transformer oil (if required) for topping will be measured and paid for separately under relevant item
(iii) If the LT bushing spindle of copper strip/steel layer strip found damaged shall be replaced with new one. The payment for replacing the strip is included in the quoted rate. SM Nos of the transformers likely to be repaired shall be written on equipment all as directed by Engr-in-Charge/GE. | 5 | Each Job | 2,000 ₹10,000 | 4,500 ₹22,500 | 1,000 ₹5,000 | 500 ₹2,500 Lowest | 2,500 ₹12,500 | 5,000 ₹25,000 | 2,000 ₹10,000 | 3,000 ₹15,000 |
| 2.00 | M&L for disconnecting, lifting, loading and transportation of unserviceable transformer indoor/outdoor type 11000/433 volts of capacity 25 KVA to 400 KVA from site to workshop for repair/rewinding and repair to the transformer by dismantling the top cover and removing unserviceable burnt LT/HT side coil from the core, rewinding the LT and HT side core complete with same size of copper wire in HT side and copper strip from LT side with suitable insulating materials, nuts, bolts, washers, gasket set etc, heating the new transformer winding in special heat chamber for demoisturising of LT/HT coil, connecting the LT/HT coils, filling the fresh transformer oil, reassembling the transformer, transporting/shifting back the transformer at site after repairs, recommissioning & testing, including applying two coats of synthetic enamel paint of approved paint after preparation of all external surfaces of transformer, complete, all as specified and directed by Engineer-in-Charge.
Note:- (i) The quoted rates shall deemed to include for the transportation, T&P, Labours from site i.e Samba inside Military Area, Dayalachak & Galak to workshop and workshop to back at site after repairs, cost of gasket set, nuts, bolts, washers, etc. (ii) All other spares such as tap changer, copper wire & copper strip for rewinding, HT/LT side bushing, transformer oil & air breather assembly with silica gel shall be measured and paid for separately as "Supply only" under respective items of this Schedule. | 6 | Each Job | 1,500 ₹9,000 | 5,500 ₹33,000 | 1,200 ₹7,200 | 500 ₹3,000 Lowest | 7,100 ₹42,600 | 7,000 ₹42,000 | 7,000 ₹42,000 | 9,800 ₹58,800 |
| 3.00 | Supply only HT bushing, 12000 volts, 50 Hz porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity complete all as specified and directed. | 16 | Each | 350 ₹5,600 | 450 ₹7,200 | 450 ₹7,200 | 250 ₹4,000 Lowest | 1,200 ₹19,200 | 700 ₹11,200 | 600 ₹9,600 | 400 ₹6,400 |
| 4.00 | Supply only HT bushing, 12000 volts, 50 Hz porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for transformer 11/0.433 KV, 50 to 200 KVA capacity complete all as specified and directed. | 25 | Each | 300 ₹7,500 | 450 ₹11,250 | 400 ₹10,000 | 275 ₹6,875 Lowest | 1,000 ₹25,000 | 600 ₹15,000 | 560 ₹14,000 | 400 ₹10,000 |
| 5.00 | Supply only LT bushing, 1100 volts, 50 Hz porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity complete all as specified and directed. | 18 | Each | 350 ₹6,300 | 450 ₹8,100 | 450 ₹8,100 | 250 ₹4,500 Lowest | 1,000 ₹18,000 | 900 ₹16,200 | 800 ₹14,400 | 700 ₹12,600 |
| 6.00 | Supply only LT bushing, 1100 volts, 50 Hz porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for transformer 11/0.433 KV, 50 to 200 KVA capacity complete all as specified and directed. | 25 | Each | 300 ₹7,500 | 450 ₹11,250 | 400 ₹10,000 | 275 ₹6,875 Lowest | 1,000 ₹25,000 | 550 ₹13,750 | 600 ₹15,000 | 800 ₹20,000 |
| 7.00 | Supply only breather assembly including it contains silica gel (deep sky blue) for the various size of transformer 50 KVA to 400 KVA complete all as specified and as directed. | 40 | Each | 350 ₹14,000 | 3,500 ₹1,40,000 | 250 ₹10,000 | 150 ₹6,000 Lowest | 850 ₹34,000 | 550 ₹22,000 | 500 ₹20,000 | 400 ₹16,000 |
| 8.00 | Supply only Silica gel (Deep sky blue) in to existing breather assembly of Power transformer 5 MVA complete all as specified and as directed. | 6 | Kg | 250 ₹1,500 | 1,000 ₹6,000 | 150 ₹900 Lowest | 180 ₹1,080 | 500 ₹3,000 | 650 ₹3,900 | 700 ₹4,200 | 500 ₹3,000 |
| 9.00 | Supply only gasket sets of minimum thickness as per OEM recommended or existing thickness for transformer tank 50 KVA to 400 KVA capacity with nuts, bolts etc complete all as directed.
Note: While dehydration of transformer existing transormer oil should be collected in clean drum after that replace the defective gaskets after placing gaskets re-fill the oil through de-hydration machine including topping up oil if required. The dehydration and topping up of oil measured as relevent item of schedule. | 20 | Each | 250 ₹5,000 | 1,000 ₹20,000 | 100 ₹2,000 | 50 ₹1,000 Lowest | 2,000 ₹40,000 | 1,300 ₹26,000 | 1,300 ₹26,000 | 900 ₹18,000 |
| 10.00 | Supply only LT/HT copper connecting terminal as per existing model from bushing to winding assembly complete all as specified and as directed. | 15 | Each | 350 ₹5,250 | 1,000 ₹15,000 | 180 ₹2,700 Lowest | 220 ₹3,300 | 900 ₹13,500 | 600 ₹9,000 | 600 ₹9,000 | 300 ₹4,500 |
Tender Value
₹35.5 L
EMD Value
₹70,920
Closing Date
26 Jun 2026, 6:00 pmClosed
SHRI AK MISHRA, IDSE, CWE
HQ CWE MAMUN PIN 145001
REPAIR REWINDING MAINTENANCE OF DIFFERENT CAPACITIES OF DISTRIBUTION TRANSFORMERS AND ITS CONNECTED HT CABLES AND HT OVER HEAD LINE WORKS HT INFRASTRUCTURE MAINTENANCE WORKS UNDER GE SAMBA
2026_MES_769951_1
CWE/M-TOKEN14/2026-27
Open Tender
Civil Works - Others
Item Rate
180 days
SAMBA
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE SAMBA
₹70,920
Yes
18 Jul 2026
5 Jun 2026
3 Jul 2026
5 Jun 2026
26 Jun 2026
19 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour charges only for inspection of defective step down transformer of 25 KVA to 400 KVA, 11 KV / 0.433 of various make , model mounted on plinth/floor/ pole mounted, indoor/outdoor type, step opening, removing the top cover of transformer, detecting the fault, rectfying the defect at site (Samba, Dayalachak & Galak) except major fault of burnt winding or other. If found winding burnt transport to workshop for repairing. The following tasks if required will be performed :-
(a) Step opening of the transformer and removing the transformer top cover for checking/rectified the faults of the transformer.
(b) Replacement of defective HT/LT bushes, brass spindles bushing to secondary winding connected copper terminals etc.
(c) Refixing the transformer top cover with OEM recommended size gasket of minimum thickness 5mm, nuts, bolts and washers if oil filing pipe cover damages replaced with suitable size of steel cover as per existing model and size the payment for gasket paid separately under relevant items of CA schedule.
(d) Testing of transformer magnetic balance test, HT/LT winding insulation test complete and produce testing certificate with the sign of contractor, Engineer-in-Charge, Technician deputed by contractor, the payment of any RAR/Bill shall not be released to the contractor without test certificate.
Note : (i) In case of replacement of LV / HV bushing / spindles / tap changer etc, will be measured and paid for separately under relevant items of CA as supply only items. (ii) Transformer oil (if required) for topping will be measured and paid for separately under relevant item
(iii) If the LT bushing spindle of copper strip/steel layer strip found damaged shall be replaced with new one. The payment for replacing the strip is included in the quoted rate. SM Nos of the transformers likely to be repaired shall be written on equipment all as directed by Engr-in-Charge/GE. | 5 | Each Job | - | - |
| 2 | M&L for disconnecting, lifting, loading and transportation of unserviceable transformer indoor/outdoor type 11000/433 volts of capacity 25 KVA to 400 KVA from site to workshop for repair/rewinding and repair to the transformer by dismantling the top cover and removing unserviceable burnt LT/HT side coil from the core, rewinding the LT and HT side core complete with same size of copper wire in HT side and copper strip from LT side with suitable insulating materials, nuts, bolts, washers, gasket set etc, heating the new transformer winding in special heat chamber for demoisturising of LT/HT coil, connecting the LT/HT coils, filling the fresh transformer oil, reassembling the transformer, transporting/shifting back the transformer at site after repairs, recommissioning & testing, including applying two coats of synthetic enamel paint of approved paint after preparation of all external surfaces of transformer, complete, all as specified and directed by Engineer-in-Charge.
Note:- (i) The quoted rates shall deemed to include for the transportation, T&P, Labours from site i.e Samba inside Military Area, Dayalachak & Galak to workshop and workshop to back at site after repairs, cost of gasket set, nuts, bolts, washers, etc. (ii) All other spares such as tap changer, copper wire & copper strip for rewinding, HT/LT side bushing, transformer oil & air breather assembly with silica gel shall be measured and paid for separately as "Supply only" under respective items of this Schedule. | 6 | Each Job | - | - |
| 3 | Supply only HT bushing, 12000 volts, 50 Hz porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity complete all as specified and directed. | 16 | Each | - | - |
| 4 | Supply only HT bushing, 12000 volts, 50 Hz porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for transformer 11/0.433 KV, 50 to 200 KVA capacity complete all as specified and directed. | 25 | Each | - | - |
| 5 | Supply only LT bushing, 1100 volts, 50 Hz porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity complete all as specified and directed. | 18 | Each | - | - |
| 6 | Supply only LT bushing, 1100 volts, 50 Hz porcelain with copper stud, nuts, bolts, washers, gasket, oil seal suitable for transformer 11/0.433 KV, 50 to 200 KVA capacity complete all as specified and directed. | 25 | Each | - | - |
| 7 | Supply only breather assembly including it contains silica gel (deep sky blue) for the various size of transformer 50 KVA to 400 KVA complete all as specified and as directed. | 40 | Each | - | - |
| 8 | Supply only Silica gel (Deep sky blue) in to existing breather assembly of Power transformer 5 MVA complete all as specified and as directed. | 6 | Kg | - | - |
| 9 | Supply only gasket sets of minimum thickness as per OEM recommended or existing thickness for transformer tank 50 KVA to 400 KVA capacity with nuts, bolts etc complete all as directed.
Note: While dehydration of transformer existing transormer oil should be collected in clean drum after that replace the defective gaskets after placing gaskets re-fill the oil through de-hydration machine including topping up oil if required. The dehydration and topping up of oil measured as relevent item of schedule. | 20 | Each | - | - |
| 10 | Supply only LT/HT copper connecting terminal as per existing model from bushing to winding assembly complete all as specified and as directed. | 15 | Each | - | - |
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_862227.xls
BOQ • 0.42 MB
TENDER14.pdf
Tender Documents • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .