Executive Engineer Cooch Behar Electrical Division
Executive Engineer Cooch Behar Electrical Division Sunity Road, Circuit House Campus
S.I.T.C of Split type AC Machine at Mothers Room in SNCU ward of Mother and Child Hub Building at Alipurduar DH, Alipurduar.
2026_WBPWD_5018549_1
WBPWD/EE/CED/eNIT-35/2026-27
Open Tender
ELECTRICAL WORKS M/R
Item Rate
21 days
Alipurduar
Please refer Tender documents.
6 documents required · 6 mandatory
₹10,590
Executive Engineer Cooch Behar Electrical Division
13 Aug 2026
13 Aug 2026
31 Aug 2026
13 Aug 2026
27 Aug 2026
21 Aug 2026
20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1PART-A - DSR Items | |||||
| 1.01 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original | - | - | - | - |
| 1.02 | Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).
Inverter Type Cooling only. | - | - | - | - |
| 1.03 | 2.0 TR with 5 Star BEE Rating | 6 | Item | 1.25 | ₹7.5 |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||
| 2.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 20 | Meter | 1.25 | ₹25 |
| 2.02 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 20 | Meter | 1.25 | ₹25 |
| 3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. | |||||
| 3.01 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire ECC | 146 | RM | 1.25 | ₹182.5 |
| 4Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 1.15 MB
BOQ_5089668.xls
BOQ • 0.38 MB
CORRIGENDUMMakelist.pdf
PDF • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].