Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.2 L+₹21,806 (0.56%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹42.8 L+₹3.8 L (9.71%)Rejected-AOC C O M KHARKARANG LUMJINGSUK BLOCK A MADANRTING SHILLONG 793021 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793021 | L3 | Rejected-AOC L3 | |
| 4 | L4₹43.4 L+₹4.4 L (11.2%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
27 Aug 2021, 6:00 pmClosed
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati-15 Assam Pin 781015 Tele 0361 2841626
SPECIAL REPAIR RENOVATION OF VIDYALAYA BUILDING AT AFS KUMBHIRGRAM
2021_MES_463343_1
CWE (AF)/KUM/TOKEN-26 OF 2021-22
Open Tender
Construction Works
Item Rate
180 days
Kumbhirgram
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I AF Kumbhirgram
₹1 L
Yes
11 Sept 2021
28 Jul 2021
30 Aug 2021
28 Jul 2021
27 Aug 2021
13 Aug 2021
Amount
B/R Works:- Preparation of old decorated plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of oil emulsion distemper complete all as specified and directed.
Preparation of old decorated plastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying two coats of white wash complete all as specified and directed.
Preparation of old decorated plastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of oil emulsion distemper complete all as specified and directed.
Preparation of old decorated plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of dark weather coat paint (Exterior grade 1st quality) complete all as specified and directed.
Preparation by removing of old paint on steel roof surfaces with paint remover or by burning off with blow lamps, cleaning by steel wire brushing, sand paper and brooming down any Nos of coats , surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Demolition of plain cement concrete (Un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) including removal of spoils/ demolished materials to a distance not exceeding 100m and depositing complete all as specified and directed.
Hacking out old broken glass of any thickness, size, quality or description from wooden frames glazed with putty or fixed with bead complete all as specified and directed.
S&F 3mm thick figured glass, pin headed type and glazing with oil putty in square not exceeding 0.50sqm in each pane complete all as specified and directed.
M&L 100mm thick plain cement concrete (1:3:6) type C2 using 40mm graded crushed stone aggregate as in floor or in hard standing, finishing surfaces even and smooth without using extra cement complete all as specified and directed.
Preparing existing black top surfaces by brushing with wire bruses for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with mechanical air compressor to remove all loose dirt and applying evenly a tack coat using paving bitumen VG-10 @ 5 kg per 10 sqm over existing black top surfaces complete all as specified and directed.
Bituminous premixed semi dense asphaltic concrete 40 mm consolidated thickness using 5.5% paving bitumen content (VG-30) and minimum 2% cement as filler by weight of total mix, using hot mix plant and laid with self propelled mechanical paver fixed with electronic sensor and hydraulic controls, rolled and compacted with 8 to 10 tonne power roller to uniform surfaces with required gradient and camber complete all as specified and directed. Note: - Semi Dense asphaltic bituminous concrete shall be designed as specified and binder contents shall be provided as per design mix.
M & L for painting lines, dashes, arrows, letters, etc on roads, pavements and the like exc 10 cm wide with road marking paint white or golden yellow all as specified and directed.
E/M WORKS(INTERNAL) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, complete all as directed.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store(to be measured only when found serviceable in all respects complete for reuse), complete all as directed.
Materials and labour for concealed point wiring with 1.50 sq.mm. FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade, single core, drawn through and including PVC conduit 20 mm dia(medium grade) complete with all fittings and accessories, fixed to walls/ceiling, including factory made sunk type mild steel terminal boxes 1.25 mm thick (wall thickness) conforming to IS-5133 (Part-I) with 3mm thick hylem sheet top cover for mounting switches/ sockets/regulator etc., including 1.50 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable 1100 Volts grade, single core, green in colour for earth continuity conductor connected to common earth dolly for One light point/ One fan point/bell point controlled by one switch including cutting chases for concealed conduit, pinning in, making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
All as per item No 17 here-in before but for one 3 pin, 5 Amp switch socket outlet point on independent board complete all as specified and directed.
All as per item No 17 here-in before but for one 3/5 pin, 16 Amp switch socket outlet on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable, complete all as specified and directed.
S&F LED tube light fittings , 18/20 W four feet, with high quality extruded polycarbonate housing & integrated LED driver with decorative end caps with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Replacement of old existing compact fluorescent lamp and providing LED lamp 9 watt suitable for B22 type holder, complete all as specified and directed.
Supply and fix batten angle lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Replacement of old existing conventional bulkhead light and providing 10 W LED Bulkhead luminaire with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F recessed mounted LED luminaire 2'x2', ultra slim LED panel made from extruded aluminium frame and bright LED's, 36 Watt with integrated LED driver & all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F switch piano flush type single pole one way 5 amps, 230 V complete all as specified and directed.
Fixing only switch piano flush type single pole one way 5 amps complete all as specified and directed. (Note:Serviceable switch piano flush type obtained from taking down of point wiring shall be reused).
S & F switch socket combination 2 in1, 5 pin 5 Amp flush type complete all as specified and directed.
S & F switch socket combination 2 in1, 3 pin 5 and 15 Amp flush type complete all as specified and directed.
Fixing only switch socket combination 2 in1, 5 pin 5 Amp flush type complete all as specified and directed. (Note:Serviceable switch piano flush type obtained from taking down of point wiring shall be reused).
Fixing only switch socket combination 2 in1, 5 pin 5/15 Amp flush type complete all as specified and directed. (Note:Serviceable switch piano flush type obtained from taking down of point wiring shall be reused).
S&F ceiling rose, surface bakelite three terminals, PVC/polycarbonate, isolated body complete all as specified & directed.
Fixing only ceiling rose, surface bakelite complete all as specified and directed. (Note:Serviceable ceiling rose obtained from taking down of point wiring shall be reused).
S&F stepped type electronic fan regulator flush type AC, 230V complete all as specified and directed.
M&L for sub main wiring with 2 runs of single core 10.0 sqmm (Nominal area) multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including concealed PVC conduit 25mm dia medium grade ISI marked with fittings and accessories including 1 x 6.0 sqmm, single core (Nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly, including cutting chases for concealed conduit, pinning in, making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.(Note: Two runs of 10.0 sqmm cable and one run of 6.0 sqmm earth continuity conductor including PVC conduit with plastic terminal boxes shall be measured as one run length).
M&L for sub main wiring with 2 runs of single core 6.0 sqmm (Nominal area) multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including concealed PVC conduit 25mm dia medium grade ISI marked with fittings and accessories including 1 x 6.0 sqmm single core (Nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly, including cutting chases for concealed conduit, pinning in, making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.(Note: Two runs of 10.0 sqmm cable and one run of 6.0 sqmm earth continuity conductor including PVC conduit with plastic terminal boxes shall be measured as one run length).
M&L for sub main wiring with 2 runs of single core 4.0 sqmm (Nominal area) multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including concealed PVC conduit 25mm dia medium grade ISI marked with fittings and accessories including 1 x 4.0 sqmm single core (Nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly, including cutting chases for concealed conduit, pinning in, making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.(Note: Two runs of 10.0 sqmm cable and one run of 6.0 sqmm earth continuity conductor including PVC conduit with plastic terminal boxes shall be measured as one run length).
S&F sheet metal enclosure MCB DB , SPN 8 way, double door with 200 Amp rated bus bar with earth and neutral link ,complete with fixing accessories flush mounting to wall including cutting chases for concealed DB and making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
S&F sheet metal enclosure MCB DB , SPN 4 way, double door with 200 Amp rated bus bar with earth and neutral link ,complete with fixing accessories flush mounting to wall including cutting chases for concealed DB and making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
S&F miniature circuit breaker (MCBs) double pole, 240 Volt, 40 Amps, "C" series,10 KA breaking capacity, complete all as specified and directed.
S&F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps complete all as specified and directed.
S&Fsheet metal enclosures with socket plug top and miniature circuit breaker (MCBs) single pole , 240 Volt, 20 Amps, "C" series,10 KA breaking capacity, complete all as specified and directed.
E/M WORKS(EXTERNAL) S&F sheet metal enclosure for MCCB DB , TPN 4 way, double door with 250 Amp copper bus bar for each phase with 2 Neutral bar, 2 Earth bar and cable ties for cable management, with provision for 250 / 160 MCCB 4 pole as incomer and DP/TP MCB's as out going and blanking plate covering blank position,complete with fixing accessories flush mounting to wall including cutting chases for concealed DB and making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
S&F MCCB 4 Pole of capacity 200 Amps, adjustable type, 415V, breaking capacity 36 KA complete all as specified and directed.
S&F MCCB 4 Pole of capacity 160 Amps, adjustable type, 415V, breaking capacity 36 KA complete all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured heavy duty underground electric cable aluminium conductor 1100 volt grade of cross sectional area 25 sqmm 4 core, connecting to LT panels, main switch with suitable size aluminium lugs, including cliping or fixing on wall or ceiling with suitable clamp, nut, bolts or laying in trenches/ ducts etc.and including taking down old existing unserviceable cable complete all as specified & directed. Note: Excavation, earth work, sand cushioning and covers shall be measured and paid separately.
Supply, laying, jointing and testing of XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured heavy duty underground electric cable aluminium conductor 1100 volt grade of cross sectional area 16 sqmm 4 core, connecting to LT panels, main switch with suitable size aluminium lugs, including cliping or fixing on wall or ceiling with suitable clamp, nut, bolts or laying in trenches/ ducts etc.and including taking down old existing unserviceable cable complete all as specified & directed. Note: Excavation, earth work, sand cushioning and covers shall be measured and paid separately.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft / loose soil complete all as specified and directed
Returning, filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the starting point , complete all as specified and as directed.
Supply and spreading dry sand of approved quality for cushioning of UG cable laid in trenches 8 cm deep before laying the cable and 15 cm thick after laying & streching the cable complete all as specified and directed. (NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid for).
Supply and laying in trenches dry well burnt locally available best quality sub class “B” bricks of size 230x115x75mm over sand cushioning for protection of cable complete all as per specified and directed.
Supply and laying/ fixing GI pipe light grade 40 mm bore for cable protection including all fittings laid in trenches or fixed on pole with suitable clamps complete all as specified and directed.
Taking down street light fittings any type and watt including accessories from 8.5/9 mtr pole and top of building or other similar situation complete all as specified and directed.
Supply, fix and testing LED street light fitting made up of pressure die cast aluminium housing, top maintainable type with toughened glass cover in IP 66 protection, 45W suitable for pole dia 40mm including fabrication of existing bracket complete all as specified and directed.
S&F polycarbonate PVC junction box/ bus bar chamber for loop connection of street light cable of size 205x255x112mm with 5 pole terminals with provision for cable entry and exit and making holes on steel pole where required, fixed on pole steel/PCC with suitable two flat iron clamp made out of 25x4mm and GI nut bolts complete all as specified and directed.
S&F in replacement PVC insulated and sheathed stranded round copper conductor 1.5 sqmm , 3 core for street light connection from light fitting to terminal box including all fixing arrangement, complete all as specified and directed.
Taking down unserviceable post top lantern/ graden light fittings any type and watt including accessories from post/gate wall complete all as specified and directed.
Supply and fix LED 35 W post top lantern made up of cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection, suitable for existing pole complete all as specified and directed.
M&L for PCC, 1:3:6, Type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete for pole complete all as specified and directed.
S&F street light panel 3 phase, TPN 63 Amp digital 24 hrs for on and off of street light, Din rail mounted single channel including time switch two module operated and power contactor 3 pole, 50amps capacity panel mounting with entry terminal din rail single channel , including taking down existing unserviceable panel complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below normal ground level, with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth lead wire 4.0 mm dia , by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15mm bore from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI watering pipe medium grade, wire mesh,charcoal or coke andcommon salt in alternative layer of 15 Cm (compacted thickness) all round the earth electrode,concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation,returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including testing on completion complete all as specified and directed.
DEBROYENTERPRISE
Bhuiya Construction
M/s Nishi Kumar Das
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .