Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹13.3 L Quoted ₹14.3 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹21.8 L+₹7.5 L (52.6%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹21.8 L+₹7.5 L (52.6%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Oct 2021, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF AMB-18/2021-22 REPAIRS AND MAINTENANCE OF FIRE ALARM SYSTEM, SPRINKLER SYSTEM, BOOM BARRIER, CHEMICAL EARTHING, VOLTAGE STABILIZER, RF PANEL AND SUB-STATION AT SITE-IV (KALPI) UNDER GE (AF) AMBALA
2021_MES_473127_1
GE AF/AMB-18/2021-22
Open Tender
Civil Works
Item Rate
120 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE AF AMBALA
₹40,000
Yes
30 Nov 2021
6 Sept 2021
6 Oct 2021
6 Sept 2021
4 Oct 2021
21 Sept 2021
13 Sept 2021 - 18 Sept 2021
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundation to electric poles, etc. with and inclusing necessary formwork complete all as specified and as directed
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in coping, bases of poles, post holes, etc. including all necessary formwork, etc. complete all as specified and as directed
M&L in repairs for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, 02Nos. galvanised iron washers and 01No. galvanised iron nut, 100mm height 65mm dia for 1100V grade of size 150mm dia and 150mm long complete all as specified and as directed
Supplying, installing, testing and commissioning outdoor type switch air break gang operated switch triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200Amps 11000V grade including 25mm dia GI medium grade pipe, supports worked from ground level vertically operated, with drop out fuse having 12 insulators, handle with locking arrangement and taking down and disposing off old GOD complete all as specified and as directed
M&L for danger notice plates, for LT of size 200x150mm, made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts including taking down old / damaged notice plates and disposing off complete all as specified and as directed
M&L for danger notice plates, for LT of size 250x200mm, made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts including taking down old / damaged notice plates and disposing off complete all as specified and as directed
Supplying, fixing / laying in repairs PVC insulated aluminium conductor cable, 2 core 16sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in service connections suspended by and including insulated hangers not more than 1.0m c/c and 4mm suspension wire complete all as specified and as directed
Supplying, laying, jointing and testing XLPE cable, 1100V grade, insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor laid in trenches, passing through ducts/pipes, fixing along poles, etc. including taking down old unserviceable cable and disposing off complete all as specified and as directed of following sizes:
4 core 16sqmm
4 core 25sqmm
Supply, erect in position and fixing steel tubular swaged poles with CI base plate (300x300mm and 6mm thick), finial taper plug, bolts, nuts, washers and screws type 410 SP-31, 9m long with detachable bracket arms, pole cap including painting with shop coat of primer including taking down and disposing off old concrete poles complete all as specified and as directed
Supply, erect in position and fixing steel tubular swaged poles with CI base plate (300x300mm and 6mm thick), finial taper plug, bolts, nuts, washers and screws type 410 SP-55, 11m long with detachable bracket arms, pole cap including painting with shop coat of primer including taking down and disposing off old concrete poles complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to concrete surfaces of electric poles with one coat of synthetic enamel paint in black & white alternate stripes, upto a height of 1m from ground, including writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular black synthetic enamel paint base complete all as specified all as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to steel poles 9/11m high/long with two coats of synthetic enamel paint in black & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
Supplying, fixing, connecting, testing and commissioning MCCB 63A, four pole, 3 phase, 16kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 125A, four pole, 3 phase, 25kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 200A, four pole, 3 phase, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
M&L for cable jointing kit for 1.1kV grade cable for straight through / end termination, heat shrink type joint, indoor/outdoor type with jointing material and accessories suitable for 3.5 core, 16 to 35mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
S&F MS sheet body 22SWG of existing size suitable for water coolers fixed wth nuts, bolts, and washers, etc. including dismantling components as required and refixing same, charging gas, etc. duly painted entirely with two coats of synthetic enamel paint (tint as approved) and testing for functionality on completion complete all as specified and as directed of the following capacities:
120/150litres
80litres
40litres
S&F bus bar chamber of size 1000x750x300mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick CRCA sheet double door with 200A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including 1No. MCCB 160A 25kA FP (cost shall be included) foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed
M&L for disconnecting from mains and taking down old / unserviceable sheet metal enclosures of any size at any location and disposing off complete all as specified and as directed
S&F sheet metal enclosures for MCB distribution board 415V, TPN, 4 way, double door type flushed inside wall with 100A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F sheet metal enclosures for MCB distribution board 240V, SPN, 8 way, double door type flushed inside wall with 100A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F sheet metal enclosures for MCB distribution board 240V, SP, 4 way, double door type flushed inside wall with 100A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs MCB TPN, 415V, 63 to 100A, 16kA complete all as specified and as directed
S&F in repairs MCB SPN, 240V, 5 to 63A, 10kA complete all as specified and as directed
S&F in repairs MCB SP, 240V, 6 to 32A, 10kA complete all as specified and as directed
Spplying and laying / fixing in position synthetic rubber insulated mat of size 2.0x1.0m, 2.5mm thick conforming to IS: 15652-2006 complete all as specified and as directed
Spplying and laying / fixing in position synthetic rubber insulated mat of size 2.0x1.0m, 2mm thick conforming to IS: 15652-2006 complete all as specified and as directed
S&F energy efficient BEE five star rated ceiling fan, 230/240V, single phase, 1200mm sweep and connecting up with provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to ceiling fan and taking down old and depositing in MES store complete all as specified and as directed
S&F heavy duty, steel body with metal blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 230/240V, single phase, 300mm sweep with lauvers and connecting up including cutting into brick walls, etc. to make suitable opening, provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts and taking down old and depositing in MES store complete all as specified and as directed
S&F electronic tamper proof meters, LED display with polycarbonate cover, 230V, single phase, 10-60A, accuracy class-1, 50Hz conforming to IS-13779. IP-54 with parameters to show data, time current reading load, PF voltage and kWH including taking down old and depositing in MES store complete all as specified and as directed
Notes for item Nos. 39 to 41 (i) Exhaust fans, ceiling fans, electric meters shall be taken down from any location, height, positions, etc. as per site (ii) Disconnection from mains and supply shall be done with requisite safety measures (iii) All cost of loading, unloading, carting, T&P, etc. as required to deposit taken down items to MES storeyard shall be deemed to be inclusive in the quoted rates
M&L for boring into roads / paths / hard standing, concrete / tiled / bituminous, etc. for insertion of GI protection / passing through pipes 50mm bore both ends socketed for passing armoured cable, at any length at any location including making good the disturbed surfaces after laying of pipes complete all as specified and as directed
Supplying, fixing / laying steel water tubing, 50mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches/poles duly fixed with suitable clamp made of MS flat iron of size 40x3mm required for protection of electric clables complete all as specified and as directed
S&F cable route indicators, fabricated from CI sheet, of suitable size as per IS standards, voltage and size of cable duly indicated, fixed on MS angle (40x40x5mm) support 500mm long, duly embedded on PCC 1:2:4 type C2 (using 40mm graded stone aggregates) foundation block of size 300x300x200mm, duly grouted on ground including applying two coats of synthetic enamel paint (of approved tint) on all exposed metal surfaces complete all as specified and as directed
S&F in repairs junction box thermoplastic polycarbonate enclosure, shock proof, IP66/IP67 (weather, rust, dust, water and vibration proof, outdoor type, internally embedded gasket with provision for all side cable entry through glands (IP-68) of size 355x255x122mm with 4Nos. aluminium bus bar of size 25x6mm, 8Nos. terminals, duly mounted fixed with MS clamps fabricated out of FI 40x3mm of required shape and size and fied at any location complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
Notes for item No. 47: (i) 2 runs of 4sqmm main cable, 1 runs of earth conductors and 1 run of PVC conduit as per item shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
S&F in repairs metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket with and inlcuding one SP MCB 20A 10kA complete all as specified and as directed
Suuply, install, testing and commisioning submersible pump set consisting of squirrel cage motor, multi-stage pump set, coupled with each other suitable for AC operation on 415V 3 phase, star delta winding of capacity suitable to discharge 10000gallons/hour at 100m head suitable for bore hole 200mm dia including taking down of old unserviceable pum from any location and disposing off complete all as specified and as directed
M&L for maintenance to check serviceability of micro-processor based intelligent fire control system with panel 10 to 12 loops / zone with control panel, wiring and detectors of any type and locating fault therein and repairing and rectifying the fault by replacing faulty parts / accessories and reconnecting the entire system and testing on completion complete all as specified and as directed Notes: (i) Job shall be done by qualified technician / Engineer of OEM (ii) Defective parts replaced will be measured and paid separately under respective item (iii) System diagram in AutoCAD, of the entire system duly marked with detectors, hooters, fire extinguishers, etc. in A3 size shall be submitted in quadruplicate to the Engineer-in-charge (iv) Testing shall be done in presence of the Users, Engineer-in-charge and the Contractor. Test certificates shall be duly vetted by all concerned and shall be submitted alongwith RAR (v) One display chart duly framed (of size as directed) showing the complete system diagram of each building in AutoCAD shall be fixed on each floor. Cost of same shall be included in the quoted rate
M&L for installation and testing suitable licensed software for fire alarm control panel suitable for 10 to 12 loops / zones compatable with existing system complete all as specified and as directed Notes: (i) Job shall be done by qualified technician / Engineer of OEM (ii) Software shall be installed at requisite location / panel / terminals as directed (iii) Software shall be having minimum license vaidity of 3years from date of installation. The license code shall be made available to the Engineer-in-charge (iv) Testing shall be done in presence of the Users, Engineer-in-charge and the Contractor. Test certificates shall be duly vetted by all concerned and shall be submitted alongwith RAR (v) The Contractor shall be liable to reload/re-install in the event of software getting corrupted by any cause whatsoever. The Contractor shall ensure proper functioning of the entire system within the software control and shall take remedial measures as required in the event of any inconsistancy (vi) Cost of above shall be included in the quoted rate
Supplying, installing, testing and commissioning of analog addressable multi sensor smoke cum heat detector/sensor with hard addressing feature, with visible bi-colour LEDs for 360o viewing, operating voltage 17-28V DC, reset voltage <3V start up current 500uA, alarm current 5mA, remote output 2mA compatable with existing system, duly fixed with standard base and junction boxes where required on false ceiling / soffits, etc. including taking down old sensors from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of UV&IR flame / smoke detectors / sensor with triple sensing technology, cast alum enclosure, hammer tone grey cabe entry 2x1.5mm conforming to protection class IP-66, with protection glass compatable with existing system, duly fixed with standard base and junction boxes where required on false ceiling / soffits, etc. including taking down old sensors from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of manual pull station type-A, indoor use, re-setable with align keys, die cast housing having break glass rod & hammer, single gang mounting, fire red in colour, integrated with addressable panel through monitor module including taking down old call points from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of hooter / strobe rated at 112dBA @3m for audible annunciation and 75cd flashings at 1Hz with visual indication for addressable type fire system including taking down old hooters from any location / position and disposing off complete all as specified and as directed
S&F in repairs expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples to steel members complete all as specified and as directed
Supplying, laying, jointing and testing 2 core 1.5sqmm copper conductor cable PVC insulated, passing through existing conduits for connecting up fire alarm panels to heat / smoke sensors, MCP, hooters, etc. complete all as specified and as directed
S&F in repairs energy efficient LED flood light fitting (beamer), 120W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.95, operating at voltage range 140 to 270V, minimum 50000 burning hours, THD> 20, aluminium housing including all fixing arrangment like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down and disposing off old fitting complete all as specified and as directed
S&F in repairs energy efficient LED street light fitting (beamer), 90W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.95, operating at voltage range 140 to 270V, minimum 50000 burning hours, THD> 20, aluminium housing including all fixing arrangment like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down and disposing off old fitting complete all as specified and as directed
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI wire of size 4mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (light grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
M&L for earthing using copper earthing strip with galvanised steel earth plate electode 600x600x3mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including copper strip of size 20x3mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (light grade), earth lead protection pipe 40mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item Nos. 60 & 61: (i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge (iv) The earth resistance shall be as desired by the installation. The quoted rate shall be deemed to be inclusive of this aspect
Supply, installation, testing and commissioning maintenance free tripod chemical earthing system as per relevant IS, consisting of 3Nos. of vertical electrodes and 10m of 20x3mm copper strip interconnected with earth electrode of UL listed and tested for 250micron copper bonded low carbon steel core of 3m length, 17.2mm dia burried directly in ground and tappered at bottom (150-175mm dia digging or augering of earth to required depth) filled up in bottom with slurry of 3kg bentonite for moisture based earth enhancing compound in slurry from 30kg bag 01No. and arrangement for connection of copper strip (20x3mm) to rod by means of clamp rods to flat clamp of size 25x3mm to the electrode tested for minimum 76% IACS, copper earth strip connected by means of clamps, provision of polymer chamber with cover, including necessary excavation, earthwork in any type of soil, rest of the bore shall be filled with earth and well compacted and top of the bore shall be finished with PCC 1:2:4 type B1 using 20mm graded stone aggregates over a 75mm thick PCC bed 1:4:8 type D2 using 40mm graded stone aggregates and backfill / JAM compound shall be covered with advance polymer pit cover of size 30x30mm complete all as specified and as directed
Notes for item No. 64: (i) The earthing shall comply to IS 3043, UL 467, BS/EN50164-7 (ii) The earth resistance shall be less than 01Ohm. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect (iii) To obtain earth resistance less than 01Ohm, if a combination two or more earthings are to be inter-connected or the length of the electrode/s is/are to be increased it shall be measured and paid as one earthing only (iv) Testing of earthing shall be carried out in presence of Departmental rep and requisite test reports shall be submitted (v) Cost of all excavation & earthwork required shall be deemed to be included in the quoted rate
The Rahul Vig
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .